Está en la página 1de 21

DISEÑO DE ESTRUCTURAS DE CONCRETO ARMADO II

MUROS DE CONTENCION EN
VOLADIZO

2021-II
Arq./Ing. Civil Jhon F. PABLO GARCIA
Propósito:

El estudiante aprenderá a diseñar muros en voladizo.

Arq./Ing. Civil Jhon F. PABLO GARCIA


DISEÑO

Arq./Ing. Civil Jhon F. PABLO GARCIA


DISEÑO DE LA ARMADURA DE LA PANTALLA Ha pantalla: ½ x Ca x W x h2
= ½ x 0.271 x 1600 x 5.92= 7546.81Kg
Mto = 7546.81 x 5.9/3
Mto = 14842.06 kg.m
Hs/c= Ca x W x hs x H
= 0.271 x 1600 x 0.94 x 5.9= 2404.75 Kg
Mto = 2404.75 x 5.9/2
Mto = 7094.01 kg.m

Mu = 1.7 x ( 14842.06 + 7094.01)


Mu = 1.7 x (21936.07)
Mu = 37 291.32 kg.m
Arq./Ing. Civil Jhon F. PABLO GARCIA
DISEÑAMOS LA ARMADURA DE LA PANTALLA
Ku = Mu /bd2
37291.32 𝑥 100
Ku = = 15.53
100 𝑥 (55−6)2

ρ= 0.0044
-----------------------------------------------------------------
PROPUESTA_01
As_req = 0.0044 x 100 x 49 = 21.56 cm2
21.56 ----------100
Ø3/4” 2.84 ------------ x

x= 13.17cm ~ 12.5 𝑐𝑚
-----------------------------------------------------------------
PROPUESTA_02

21.56 ----------100
Ø5/8” 2.00 ------------ x

x= 9.27cm ~ 7.5 𝑐𝑚
-----------------------------------------------------------------

Arq./Ing. Civil Jhon F. PABLO GARCIA


DISEÑO DE LA ARMADURA DE LA PANTALLA Ha1 pantalla: ½ x Ca x W x h2
= ½ x 0.271 x 1600 x 2.952= 1886.70Kg
Mto = 1886.70 x 2.95/3
Mto = 1855.26 kg.m
Hs/c1= Ca x W x hs x H
= 0.271 x 1600 x 0.94 x 2.95= 1202.37 Kg
Mto = 1202.37 x 2.95/2
Mto = 1773.50 kg.m

Mu = 1.7 x (1855.26+1773.50)
Mu = 1.7 x (3628.76)
Mu = 6 168.9 kg.m
Arq./Ing. Civil Jhon F. PABLO GARCIA
DISEÑAMOS LA ARMADURA DE LA PANTALLA
Ku = Mu /bd2
6168.89 𝑥 100
Ku = = 4.63
100 𝑥 (42.5−6)2

ρ= 0.0013
-----------------------------------------------------------------
PROPUESTA_01
As_req = 0.0013 x 100 x 36.5 = 4.75 cm2
4.75 ----------100
Ø3/4 2.84 ------------ x
x= 59.8cm
-----------------------------------------------------------------
PROPUESTA_02
4.75 ----------100
Ø5/8” 2.00 ------------ x

x= 42.11 cm
-----------------------------------------------------------------
Se debe calcular el punto de corte del acero

Arq./Ing. Civil Jhon F. PABLO GARCIA


GENERANDO ECUACIÓN DE MOMENTOS

Mx = 407.58*X*X/2 + 433.6*X^3/6
Mx= 203.79*X^2 + 72.27*X^3

PROPUESTA_01
As_col ----------100 cm
Ø3/4 2.84 ------------ 25 cm
As_col = 11.36 cm2
Mr=As*fy(d-a/2)
a=(As*fy)/(0.85*f´c*b)
a= (11.36*4200)/(0.85*210*100)
a= 2.67 cm

Mr=11.36*4200*(49-2.67/2)
Mr=22 741.93 kg.m
Mru=22 741.93/1.7 kg.m
Mru=13 377.61 kg.m
PROPUESTA_01

72.27𝑥 3 + 203.79𝑥 2 = 13377.61

72.27𝑥 3 + 203.79𝑥 2 − 13377.61 = 0

𝑥 = 4.90 𝑚
𝑃𝑡𝑜_𝑡𝑒ó𝑟𝑖𝑐𝑜_𝑐𝑜𝑟𝑡𝑒 = 5.90 − 4.90
𝑃𝑡𝑜_𝑟𝑒𝑎𝑙_𝑐𝑜𝑟𝑡𝑒 = 1 + 0.49 = 1.50 𝑚.
GENERANDO ECUACIÓN DE MOMENTOS

Mx = 407.58*X*X/2 + 433.6*X^3/6
Mx= 203.79*X^2 + 72.27*X^3

PROPUESTA_02
As_col ----------100 cm
Ø5/8” 2.00 ------------ 15 cm
As_col = 13.33 cm2
Mr=As*fy(d-a/2)
a=(As*fy)/(0.85*f´c*b)
a= (13.33*4200)/(0.85*210*100)
a= 3.14 cm

72.27𝑥 3 + 203.79𝑥 2 = 15620. 10


Mr=13.33*4200*(49-3.14/2)
72.27𝑥 3 + 203.79𝑥 2 − 15620. 10 = 0
Mr=26 554.15 kg.m
𝑥 = 5.19 𝑚
Mru= 26 554.15/1.7 kg.m
Mru=15 620.10 kg.m 5.9 − 𝑥 = 5.9 − 5.19 𝑚 = 0.71 𝑚
1𝑒𝑟𝑐𝑜𝑟𝑡𝑒 = 0.71 + 0.49 = 1.2 𝑚
72.27𝑥 3 + 203.79𝑥 2 = 7945.26
GENERANDO ECUACIÓN DE MOMENTOS
72.27𝑥 3 + 203.79𝑥 2 − 7945.26 = 0

𝑥 = 4.01 𝑚
Mx = 407.58*X*X/2 + 433.6*X^3/6
Mx= 203.79*X^2 + 72.27*X^3 5.9 − 𝑥 = 5.9 − 4.01 𝑚 = 1.89 𝑚
2𝑑𝑜_𝑐𝑜𝑟𝑡𝑒 = 1.89 + 0.49 = 2.4 𝑚

PROPUESTA_02
As_col ----------100 cm
Ø5/8” 2.00 ------------ 30 cm
As_col = 6.67 cm2
Mr=As*fy(d-a/2)
a=(As*fy)/(0.85*f´c*b)
a= (6.67*4200)/(0.85*210*100)
a= 1.57 cm

Mr=6.67*4200*(49-1.57/2)
Mr=26 554.15 kg.m
Mru= 13506.95/1.7 kg.m
Mru=7945.26 kg.m
Arq./Ing. Civil Jhon F. PABLO GARCIA
REFUERZO MINIMO VERTICAL

As. Min. Vertical superior (2 capas)


=0.0015*100*42.5=6.38 cm2

As. Min. Vertical inferior (2 capas)


=0.0015*100*55=8.25 cm2

Arq./Ing. Civil Jhon F. PABLO GARCIA


Cuantía mínima horizontal = 0.0025
Cuantía mínima vertical = 0.0015
• As min vertical inferior = 0.0015 x 100 x x55 = 8.25 cm2
• As min vertical superior = 0.0015 x 100 x 42.5 = 6.38 cm2
• As min horizontal inferior = 0.0025 x 100 x 55 = 13.75 cm2
• As min horizontal superior = 0.0025 x 100 x 42.5 = 10.63 cm2

Arq./Ing. Civil Jhon F. PABLO GARCIA


DISEÑO DE LA ARMADURA DEL TALON

Wu = 1.4 * ( suelo * h +  c * P) + 1.7 * s / c − 1.7 * talon

𝑊𝑢 = 1.4 ∗ (1600 ∗ 5.9 + 2400 ∗ 0.6) + 1.7 ∗ 1500 − 1.7 ∗ 2100

𝑊𝑢 = 15232 + 2550 − 3570

𝑊𝑢 = 14 212 𝑘𝑔/𝑚

2.05 2
𝑀𝑢 = 14212 ∗ = 29862.965 𝑘𝑔. 𝑚
2
Arq./Ing. Civil Jhon F. PABLO GARCIA
DISEÑO DE LA ARMADURA DEL TALON

𝑀𝑢 = 29 862.965 𝑘𝑔. 𝑚
29 862.965 ∗ 100
𝐾𝑢 = = 11.95
100 ∗ 50^2

𝜌 = 0.0033

𝐴𝑠𝑟𝑒𝑞 = 0.0033 ∗ 100 ∗ 50

𝐴𝑠𝑟𝑒𝑞 = 16.50 𝑐𝑚2

100. . . . . . . . . . . . 16.5 𝑐𝑚2 X=17.21 cm


Ø3/4
𝑥. . . . . . . . . . . . . . . . 2.84 𝑐𝑚2
¾’’@0.15 cm

Arq./Ing. Civil Jhon F. PABLO GARCIA


REFUERZO TRANSVERSAL

As. transversal=0.0012*b*(h-10)

As.=0.0012*100*(60-10)

As.=0.0012*100*50

As=6 cm2

100. . . . . . . . . . . . 6 𝑐𝑚2 x=21.5cm


𝑥. . . . . . . . . . . . . . . 1.29 𝑐𝑚2

½’’@0.20cm

Arq./Ing. Civil Jhon F. PABLO GARCIA


DISEÑO DE LA ARMADURA DE LA PUNTA

𝑊𝑢 = 1.7 ∗ 𝜎𝑝𝑢𝑛𝑡𝑎
𝑊𝑢 = 1.7 ∗ 17100
𝑊𝑢 = 29070 kg/m

Arq./Ing. Civil Jhon F. PABLO GARCIA


0.902
𝑀𝑢 = 29070 ∗
2

𝑀𝑢 = 11773.35 𝑘𝑔/𝑚

11773.35∗100
𝐾𝑢 = = 4.71
100∗50^2

𝜌 = 0.00127

𝐴𝑠 = 0.00127 ∗ 100 ∗ 50 = 6.35 𝑐𝑚2

100. . . . . . . . . . . . 6.35 𝑐𝑚2


𝑥. . . . . . . . . . . . . . . 2.0 𝑐𝑚2

X=31.5 cm
5/8’’@0.30 cm

Arq./Ing. Civil Jhon F. PABLO GARCIA


REFUERZO TRANSVERSAL

As. transversal=0.0012*b*(h-10)

As.=0.0012*100*(60-10)

As.=0.0012*100*50

As=6 cm2

100. . . . . . . . . . . . 6 𝑐𝑚2 x=21.5cm


𝑥. . . . . . . . . . . . . . . 1.29 𝑐𝑚2

½’’@0.20cm

Arq./Ing. Civil Jhon F. PABLO GARCIA


Gracias por su atención…

También podría gustarte