Está en la página 1de 11

ROTOR JAULA CONEXIÓN Y

TENSION 400V-230V CORRIENTE 0.7-1.2 POTENCIA 0.3KW

PERDIDAS MECANICAS
RPM PAR P2 W S U I
1800 0.15 26 0 1 0.01

PRUEBA EN VACIO
RPM PAR P2 W S U I
1795 0 0 0 400 0.3
LINEA 398 0.3
FASE 232 0.3

PRUEBA ROTOR BLOQUEADO


RPM PAR P2 W S U I
0 0.15 0 100 118 0.71
LINEA 118 0.71
FASE 67.4 0.71

PRUEBA A VALORES NOMINALES


RPM PAR P2 W S U I
1630 1.54 261 10 403 0.71

PRUEBA A VALORES NOMINALES


RPM PAR P2 W S U I
1581 1.81 301 12 400 0.85
CARACTERISTICAS OPERATIVAS
PAR POTENCIA MECANICA DESLIZAMIENTO
n [rpm] M [Nm] P2 [W] s/% U [V] I [A] S [VA]
1791 -0.03 -5.6265 0.5 398.958 0.29778 205.774
1695 1.04 184.6 5.83333 400.993 0.519 360.469
1604 1.75 293.948 10.8889 395.801 0.80948 554.942
1508 2.19 345.839 16.2222 395.934 1.06504 730.382
1414 2.46 364.261 21.4444 398.756 1.29292 892.973
1318 2.59 357.473 26.7778 400.458 1.46748 1017.87
1226 2.67 342.792 31.8889 398.5 1.60912 1110.65
1130 2.69 318.317 37.2222 395.125 1.73132 1184.88
1036 2.7 292.922 42.4444 396.901 1.86002 1278.68
942 2.65 261.412 47.6667 399.499 1.95669 1353.93
846 2.6 230.342 53 395.704 2.01591 1381.66
752 2.56 201.598 58.2222 396.174 2.08865 1433.21
658 2.51 172.953 63.4444 396.76 2.17391 1493.93
565 2.45 144.958 68.6111 400.352 2.23455 1549.51
472 2.4 118.627 73.7778 399.814 2.2593 1564.56
378 2.34 92.6267 79 396.221 2.30357 1580.88
282 2.32 68.5119 84.3333 399.769 2.35995 1634.07
188 2.29 45.0839 89.5556 398.912 2.36336 1632.93
94 2.31 22.7388 94.7778 395.742 2.40369 1647.59
3 2.39 0.75084 99.8333 398.06 2.41526 1665.23
M [Nm]
3

2.5

1.5
PAR

M [Nm]
1

0.5

0
0 200 400 600 800 1000 1200 1400 1600 1800 2000
-0.5
RPM
ASIGNADO
COS Q 0.76

S VA P1 W Q VAR COS Q n
0 0 0 0.16 0

S VA P1 W Q VAR COS Q n
209 64 199 0.31 0

S VA P1 W Q VAR COS Q n
144 102 101 0.72 0

S VA P1 W Q VAR COS Q n
491 435 233 0.88 61

S VA P1 W Q VAR COS Q n
583 521 260 0.89 58
POTENCIA ELÉCTRICA RENDIMIENTO
P1 [W] Q [Var] cos Eta [%]
54.776 198.349 0.266195 0
298.798 201.637 0.828915 61.7808
492.386 255.962 0.887275 59.6988
651.269 330.617 0.891682 53.1024
790.168 415.976 0.884873 46.0993
890.84 492.398 0.875204 40.1277
954.614 567.676 0.859509 35.9089
995.69 642.287 0.840333 31.9694
1058 718.089 0.827417 27.6864
1111.21 773.531 0.820727 23.525
1108.23 825.119 0.802097 20.7847
1133.32 877.324 0.790751 17.7883
1169.4 929.694 0.782767 14.7899
1209.18 968.952 0.780362 11.9882
1204.38 998.654 0.76979 9.84958
1193.76 1036.4 0.755125 7.75923
1238.9 1065.51 0.75817 5.53003
1219.65 1085.78 3.69647
1215.4 1112.37 0.737683 1.87089
1227.8 1124.94 0.737315 0.0611535
ROTOR DEVANADO CONEXIÓN Y
TENSION 400V-230V CORRIENTE 0.7-1.2 POTENCIA 0.3KW 0.76

PERDIDAS MECANICAS
RPM PAR P2 W S U I S VA
1800 0.15 28 0 4 0.01 0

PRUEBA EN VACIO
RPM PAR P2 W S U I S VA
1773 0.02 0 2 401 0.33 235
LINEA 396 0.33
FASE 230 0.33

PRUEBA ROTOR BLOQUEADO


RPM PAR P2 W S U I S VA
0 0.2 0 100 168 0.7 204
0.36 0 100 250 1.06 455
LINEA 249 1.06
FASE 144 1.06

PRUEBA A VALORES NOMINALES


RPM PAR P2 W S U I S VA
1580 1.34 222 12 403 0.72 504
LINEA 398.6 0.72
FASE 231 0.72

PRUEBA A VALORES NOMINALES


RPM PAR P2 W S U I S VA
1400 1.76 258 22 400 1.03 711
LINEA 397 1.02
FASE 231 1.02

NO LLEGA A 300 W
CARACTERISTICAS OPERATIVAS
PAR POTENCIA MECANDESLIZAMIENTO POTENCIA ELÉCTRICA
n [rpm] M [Nm] P2 [W] s/% U [V] I [A] S [VA] P1 [W]
1783 -0.02 -3.7343 0.94444 404.287 0.32761 229.412 63.4648
1689 0.72 127.348 6.16667 400.506 0.47326 328.299 230.389
1597 1.3 217.409 11.2778 399.928 0.69529 481.626 382.715
1501 1.62 254.639 16.6111 400.02 0.90354 626.025 500.379
1408 1.79 263.927 21.7778 399.159 1.0634 735.197 572.135
1313 1.85 254.37 27.0556 398.882 1.20183 830.322 627.303
1218 1.87 238.516 32.3333 398.968 1.31413 908.11 664.371
1126 1.85 218.142 37.4444 399.244 1.4018 969.361 685.697
1032 1.81 195.608 42.6667 398.951 1.47288 1017.76 699.239
939 1.76 173.064 47.8333 400.144 1.54606 1071.53 723.769
842 1.69 149.014 53.2222 398.812 1.58935 1097.86 714.589
751 1.64 128.977 58.2778 400.154 1.64585 1140.71 733.615
655 1.6 109.746 63.6111 398.308 1.67181 1153.36 717.566
562 1.53 90.0443 68.7778 399.488 1.71518 1186.8 726.76
469 1.49 73.1792 73.9444 398.451 1.73084 1194.52 714.956
376 1.45 57.0932 79.1111 398.774 1.76761 1220.88 722.38
282 1.42 41.934 84.3333 398.73 1.78958 1235.92 721.354
188 1.4 27.5622 89.5556 402.175 1.80624 1258.21 736.715
85 1.3 11.5715 95.2778 402.442 1.8226 1270.44 734.08
0 1.46 0 100 399.107 1.82889 1264.26 704.999

M [Nm]
3

2.5

1.5
PAR

M [Nm]
1

0.5

0
0 200 400 600 800 1000 1200 1400 1600 1800 2000
-0.5
RPM
P1 W Q VAR COS Q n
0 0 0 0

P1 W Q VAR COS Q n
80 223 0.3 0

P1 W Q VAR COS Q n
105 174 0.52 0
245 387 0.52 0

P1 W Q VAR COS Q n
403 300 0.81 56

P1 W Q VAR COS Q n
560 430 0.8 45
OTENCIA ELÉCTRICA RENDIMIENTO
Q [Var] cos Eta [%]
220.459 0.276645 0
233.882 0.701766 55.275
292.391 0.794632 56.8069
376.202 0.799296 50.8892
461.71 0.778207 46.1302
543.991 0.755494 40.5497
619.092 0.731598 35.901
685.186 0.70737 31.8131
739.533 0.687034 27.9744
790.145 0.675456 23.9115
833.463 0.650892 20.8531
873.52 0.643119 17.581
902.962 0.622152 15.2942
938.245 0.612372 12.3898
956.926 0.598532 10.2355
984.236 0.591687 7.90349
1003.57 0.583657 5.81323
1019.97 0.585528 3.74123
1036.9 0.577814 1.57633
1049.44 0.557637 0