Está en la página 1de 1

DET.

4 CONTRATO/ORDEN DE COMPRA

E
7025 3000 EL.+126.650
EL.+124.150 900 5225 900
ESTRUCTURA PB1D
D E F V1
H200X150X30.6
5100 MR1
H250X200X60.5 NUMERO DESCRIPCION

N
1100 2000 2000

S
7900
C - - -

H200X150X30.6

H200X150X30.6
C-904 CONTRATO CIVIL ELECTROMECANICO
H

W
.1
620 - 22
3 150X
DVJ150X

938

MR2

MR1
5100 MR2 -
DET. 2

DHJ100X
C

.2
C
H250X200X60.5

H200X150X30.6

14

H200X150X30.6
H200X150X30.6
H200X150X30.6

1 100X
1100 2000 2000

0X
EL.+126.650

938

10
3000

1
0X
DH
10
G

14

CJ
.2
V1

V1
V1
V1
ESTRUCTURA PB1C
900

1500
-
SP4 SP4
H200X150X26.1
SECCION D
-
H200X150X26.1

DET. 3 ESC. 1:100 MR2

DCVJ150
H250X200X60.5

H200X150X30.6
2 X150
1500

4350
EL.+126.650
SECCION G

X2
3000

2.1

C7
V1 ESC. 1:100
-
5225

H200X150X30.6

1775
EL.+122.300
D
DET. 1 CJ V3 PLANOS ASOCIADOS/ESTANDARES DE DISEÑO

H200X150X30.6
15

H200X150X30.6
0X
15 5100
0X
22 A1-5005-72-11-02-023 LAYOUT GENERAL PROYECTO MAPA - PLANTA
.1
1100 4000

MR2
ESTRUCTURA PB1C

MR1
1775
MR1 EL.+126.650 A1-5005-711-04-100 DISPOSICION GENERAL DE PARRONES DE CAÑERIAS
H250X200X60.5

17010
ESTRUCTURA PB1C
900

A1-5005-768-01-624 ISOMETRICO S. ELECTRICOS EN PB-05,PB1E,PB8B,PB07,PB19

1400
SECCION E A1-5005-768-01-625 ISOMETRICO S. ELECTRICOS EN PB1C,PB1D,PB08A Y SALA ELEC.21

SECCION B -

DCVJ150
ESC. 1:100
WAS-768-01-605_REV_B MODELO DE INGENIERIA

2 X150
1400
ESTRUCTURA PB1D C1
A ESC. 1:100
- H200X150X30.6

X2
2.1
- 3000 EL.+126.650

1400
MR2
SP3 SP3 H200X150X30.6 V1
H200X150X26.1 H200X150X26.1 H200X150X30.6

NOTAS
MR1

1400
H200X150X30.6
ESTRUCTURA PB1C 1.-VER NOTAS GENERALES A1-5005-768-01-6562/M01
2-.ESTE PLANO SE COMPLEMENTA CON
SP4 A1-5005-768-01-6562/M01@M03 - M05

.1
SP4

22
H200X150X30.6

H200X150X30.6
0X
CJ100X100X14.2 CJ100X100X14.2

1400

15
4
0X
900 5225 900
SECCION H

DV
15
CJ
C7

C1
SECCION C
ESC. 1:100
-

1400
ESC. 1:100
-
SECCION F

135
ESC. 1:100
-
SECCION A DET. 8
ESC. 1:100
- 1285
3000

E DET. 5 DET. 7 1285 SP10


CJ150X150X22.1
SP10
CJ150X150X22.1
2000 2000 SP10
M CJ150X150X22.1

DET. 6
N

S
PL13 - PU4 PU8
PL10X322
DV11 CJ100X100X14.2 CJ100X100X14.2 PU4
CJ100X100X14.2

I PU8
L100X100X8
W

2150
DV11

2150
CJ100X100X14.2
ER4 SP11 L100X100X8
SP11
H200X150X30.6 CJ150X150X22.1

DCHJ100
SP11

H200X150X30.6
- CJ150X150X22.1
1360

8 X100
CJ150X150X22.1

2150
DV14
CJ100X100X14.2 SP10
DET. 9

X1
PU3 PU7

4.2
V9
CJ150X150X22.1
CJ100X100X14.2
PU3
J
CJ100X100X14.2
PL12
K

2350
C8 CJ100X100X14.2

2350
PL10X311
H200X150X30.6
SP10 DV12

H200X150X30.6
4.2
H200X150X30.6 - DV12 SP10
-

X1
L100X100X8
CJ150X150X22.1 PU7
SECCION I
L100X100X8 CJ150X150X22.1
SP10

00

2150
8
X1
CJ100X100X14.2
DH CJ150X150X22.1

ER4
10
-
CJ
ESC. 1:100

3150
V9

1350
PU2 PU5 DV13
33872

1350
PU1 CJ100X100X14.2 CJ100X100X14.2 L100X100X8
PL13 CJ100X100X14.2
PU2
PL10X322 PU6
L
CJ100X100X14.2
2000 DV13 CJ100X100X14.2
ESTRUCTURA PB07 L100X100X8 SP9
CJ150X150X22.1
SP9
- SP9 CJ150X150X22.1

PLANTA ESTRUCTURA SOPORTE PB07 ESTRUCTURA PB19


CJ150X150X22.1
ESTRUCTURA PB19
SECCION M
SECCION K SECCION L
E

ESTRUCTURA PB19
C8
H200X150X30.6
ESC. 1:100
-
3648 SOPORTE PB 19 ESC. 1:100
- ESC. 1:100
-
N

ER4
SP1 CN1 H200X150X30.6
PL5
H200X150X30.6 PL10X300 75 75
PL8X150 V1
W

ESTRUCTURA PB1C PL1


DET. 11 8* BOLT 5/8"DIA A325 TC 2" H200X150X30.6

MR2 PL1 PL8X60


45 45
1000

PL8X60
H250X200X60.5 8* BOLT 5/8"DIA A325 TC 13/4"

45
PL2
CN1 SECCION J PL6X120 C1
H200X150X30.6
MR2
H200X150X30.6

-
PL10X300
1100 2000 2000 ESC. 1:100 DV2 PL2

110
CJ150X150X22.1
PL6X120 0 01/12/2020 APROBADO PARA CONSTRUCCION MYD MYD FMR
8* BOLT 5/8"DIA A325 TC 2"
DET. 10 MR2
H200X150X30.6
PL1
PL8X60 PL1
PL8X60
REV. D/M/A DESCRIPCION DIB CH. APR.

O 4 * BOLT 3/4"DIA A325 TC 13/4"


arauco
PL5
PL8X150

SOPORTE SALA ELECTRICA 21 TIP. EL.+124.300 4 * BOLT 3/4"DIA A325 TC 21/4" N -


SECCION O
- SECCION N ESC. 1:20
-
CELULOSA ARAUCO Y CONSTITUCION S.A.
DETALLE 2
3000

GERENCIA DE INGENIERIA Y CONSTRUCCION

ESC. 1:20
ESC. 1:20
- DETALLE 4
ESTRUCTURA PB1C DETALLE 3 ESC. 1:20
ESTRUCTURA PB07 ESC. 1:20
B ER4 DETALLE 1 SP10
CJ150X150X22.1
TIP.
H200X150X30.6
ESC. 1:20 DV11
- (T.A.) ER4 L100X100X8
H200X150X30.6 ESTRUCTURA PB19 SP10
4000 ESTRUCTURA PB07 CJ150X150X22.1
V9
V9 H200X150X30.6 SP11
CJ150X150X22.1
H200X150X30.6
TIP.
TIP. arauco
5998

MARCELO SUBIABRE ORLANDO FUENTES


P DV11
GERENTE DE INGENIERIA SUBGERENTE DE AREA

4 * BOLT 3/4"DIA A325 TC 2" PROY. N º


DH8 - TIP. L100X100X8
ESTRUCTURA PB1C CJ100X100X14.2
TIP.
DV14
PU8
CJ100X100X14.2
HANS AMSTEIN
JEFE PROYECTO
RODRIGO HUENCHULLÁN
LIDER DE ESPECIALIDAD 5005
DETALLE 5
CJ100X100X14.2
DETALLE 7
ESC. 1:20
SECCION P DETALLE 6 ESC. 1:20 DV12
ESC. 1:20
- ESC. 1:20 DETALLE 8 L100X100X8

ESC. 1:20

4 PERFØ21mm ESTRUCTURA PB19

PLANTA DISTRIBUCION PB1B Y PB1C


P/PERNO Ø 3/4" 150 150
ER4 PROYECTO MAPA
310
50 50 CN1
PL10X300
H200X150X30.6
DETALLE 9 SUBGERENCIA BOP
ESC. 1:20
75

CN1 100 170 10


PL10X250
150

325

GU1
125

PL29X60

2 * BOLT 3/4"DIA A325 TC 13/4"


AREA
C8
25

H200X150X30.6
768 DISTRIBUCION ENERGIA ELECTRICA
SECCION Q DETALLE 11
125

SP1
-
H200X150X30.6
ESC. 1:20 ESC. 1:20
GU1 TITULO
PL29X60

Q ESTRUCTURA SOPORTES ELECTRICOS


-
PLANTA ESTRUCTURA PB01B/C -PB07 Y S.ELECTRICA 21

ESCALA NOMBRE FIRMA FECHA


DETALLE 10 PROYECTO: R. HERNANDEZ 20/09/16
ESC. 1:20 INDICADA DIBUJO: G. RIQUELME 20/09/16
REVISO: P. YEVENES 20/09/16
APROBO: P. LEGH 20/09/16
REV. REV. REV. 0 REV. 0 REV. 0 REV. 0 REV.
Tekla Structures

EMISION D/M/A APR. EMITIDO PARA EMISION D/M/A APR. EMITIDO PARA EMISION D/M/A APR. EMITIDO PARA EMISION D/M/A APR. EMITIDO PARA EMISION D/M/A APR. EMITIDO PARA EMISION D/M/A APR. EMITIDO PARA PLANO No:

0 01/12/2020 M.R.M APROBADO PARA CONSTRUCCION


A1-5005-768-01-6562/M04 0
$DATE$ $TIME$

También podría gustarte