EJEMPLO N° 1 - RESUMEN DE LAS FUERZAS DE VIENTO - CASO: VIENTO TRANSVERSAL A LA CUMBRERA

(q x Gh x Cp) + (q x Gh x Cp) - Ancho Fuerza de


kz kh q x G h x Cp qh x GCpi Cond.
Superficie z (m) h (m) q (kg/m2) Tributario Viento
(qh x GCpi) (qh x GCpi) Crítica
(m) (kg/m)

4.50 0.801 55.93 55.44 18.17 73.61 37.27 73.61 6.00 442

5.00 0.825 57.64 57.14 18.17 75.31 38.97 75.31 6.00 452

6.00 0.870 60.73 60.19 18.17 78.36 42.02 78.36 6.00 470

Barlovento 7.00 0.909 63.46 62.90 18.17 81.07 44.73 81.07 6.00 486

Fachadas 8.00 0.944 65.93 65.35 18.17 83.52 47.18 83.52 6.00 501

9.00 0.976 68.19 67.59 18.17 85.75 49.42 85.75 6.00 515

10.00 1.006 70.27 69.65 18.17 87.82 51.48 87.82 6.00 527

Sotavento 11.25 1.041 72.67 -45.02 18.17 -26.85 -63.19 -63.19 6.00 -379

Laterales 11.25 1.041 72.67 -63.03 18.17 -44.86 -81.20 -81.20 6.00 -487

Barlovento 11.25 1.041 72.67 -67.53 18.17 -49.36 -85.70 -85.70 6.00 -514
Techo
Sotavento 11.25 1.041 72.67 -63.03 18.17 -44.86 -81.20 -81.20 6.00 -487