Documentos de Académico
Documentos de Profesional
Documentos de Cultura
REVISIÓN: 1
CAPACIDAD DE CARGA:
11 DE ABRIL DE 2020
1
MEMORIA DE CÁLCULO ESTRUCTURAL MONOPOLO 2020
TABLA DE CONTENIDO
1. INTRODUCCIÓN...................................................................................................................... 3
2. NORMAS UTILIZADAS............................................................................................................ 3
3. MATERIALES ............................................................................................................................ 3
4. VELOCIDAD DE VIENTO DE DISEÑO ................................................................................. 4
5. ANÁLISIS DE CARGAS DE VIENTO SEGÚN ANSI/TIA-222-G........................................ 4
5.1 Determinación fuerza de diseño sobre la estructura, 𝑭𝒔𝒕 (PAG 23, ANSI/TIA-
222-G). ........................................................................................................................................... 4
5.2 Determinación de la presión dinámica, 𝒒𝒛 (PAG 34, ANSI/TIA-222-G) ................. 4
5.3 Determinación del factor ráfaga, 𝑮𝒉 (PAG 20, ANSI/TIA-222-G) ............................ 7
5.4 Área proyectada efectiva de las estructuras tipo monoposte .................................... 7
6. ANÁLISIS DE CARGAS VIVAS (L) Y MUERTAS (D) .......................................................... 8
6.1 CARGAS VIVAS (L) ......................................................................................................... 8
6.2 CARGAS MUERTAS (D) ................................................................................................. 9
7. METODOLOGIA PARA EL ANÁLISIS ESTRUCTURAL..................................................... 9
8. METODOLOGÍA PARA EL DISEÑO DE LA ESTRUCTURA METÁLICA ...................... 10
9. DISEÑO DE CONEXIONES.................................................................................................. 10
10. DESPLAZAMIENTO MÁXIMO .......................................................................................... 10
11. RESULTADOS FACTOR DE UTILIZACIÓN MÁXIMO.................................................. 11
2
MEMORIA DE CÁLCULO ESTRUCTURAL MONOPOLO 2020
1. INTRODUCCIÓN
CONSIDERACIONES
Clasificación de la estructura II
Categoría de exposición C
Categoría topográfica 1
2. NORMAS UTILIZADAS
3. MATERIALES
Láminas para la estructura principal del monopolo: ASTM A36 (Fy = 248 MPa,
Fu = 400 MPa).
Perfiles angulares, platinas, rigidizadores: ASTM A36 (Fy = 248 MPa, Fu = 400
MPa).
Pernos (conexiones): A325
Soldadura típica E70XX
Pernos de anclaje: F 1554-55
3
MEMORIA DE CÁLCULO ESTRUCTURAL MONOPOLO 2020
Donde:
𝑞 = 0.613 ∗ 𝐾𝑧 ∗ 𝐾𝑧𝑡 ∗ 𝐾𝑑 ∗ 𝑉 ∗ 𝐼 𝑁
𝑚
Donde,
𝐾 = 2.01 ∗ 𝑧 𝐾 ≤ 𝐾 ≤ 2.01
𝑧
Donde:
4
MEMORIA DE CÁLCULO ESTRUCTURAL MONOPOLO 2020
𝐾𝑒 ∗ 𝐾𝑡
𝐾 = 1+
𝐾ℎ
5
MEMORIA DE CÁLCULO ESTRUCTURAL MONOPOLO 2020
6
MEMORIA DE CÁLCULO ESTRUCTURAL MONOPOLO 2020
El área proyectada efectiva, (EPA)S, de una sección tipo monoposte se deberá determinar
de acuerdo con la siguiente ecuación:
Donde:
AP = área proyectada efectiva real en base al diámetro exterior del monoposte (secciones
circulares), al diámetro exterior punto a punto (secciones poligonales) o al ancho total,
incluyendo el espesor de hielo para las combinaciones de cargas que incluyen hielo
7
MEMORIA DE CÁLCULO ESTRUCTURAL MONOPOLO 2020
8
MEMORIA DE CÁLCULO ESTRUCTURAL MONOPOLO 2020
9
MEMORIA DE CÁLCULO ESTRUCTURAL MONOPOLO 2020
9. DISEÑO DE CONEXIONES
Las fuerzas de viento horizontales para determinar las cargas de servicio se deberán
basar en un factor de importancia, I, de 1.00, y un factor de direccionalidad, Kd, de 0.85
para todas las estructuras. El coeficiente de presión dinámica, Kz, el factor de ráfaga, Gh,
y el factor topográfico, Kzt, deberán ser iguales a los valores para la condición
correspondiente al estado límite de resistencia.
10
MEMORIA DE CÁLCULO ESTRUCTURAL MONOPOLO 2020
Al realizar el análisis se obtiene un factor de utilización máximo de 86.3 % del cuerpo del
monopolo.
11
18.0 m (2) System
MW
Radomo
Luces
Pararrayos
Plataforma
Luminarias
Plint
FRHC
(3)
FXCB
FXFC
System
Gab 2533x353x209
con
Bat
Rec
(Base
560x447x133
de
560x447x133
Module
ZTE
radomo
ZTE
obstrucción
de
Module
equipos)
trabajo
ESMB
0.60
FSMF
DESIGNED
18
13
APPURTENANCE LOADING
TYPE ELEVATION TYPE ELEVATION
(2) 2533x353x209 18 Gab Bat ZTE 13
(2) 2533x353x209 18 Plint (Base de equipos) 13
(2) 2533x353x209 18 FRHC 560x447x133 13
MW con radomo 0.60 18 (3) System Module FSMF 13
Radomo 18 FXCB 560x447x133 13
Luces de obstrucción 18 FXFC 560x447x133 13
Pararrayos 18 System Module ESMB 13
Plataforma de trabajo 18 Gab Rec ZTE 13
Luminarias 18
6.0000
400x6
454.7
1
MATERIAL STRENGTH
GRADE Fy Fu GRADE Fy Fu
A36 248211 kPa 399896 kPa
769.3
2
6.0 m
6.0000
610x8
926.3
3
ALL REACTIONS
ARE FACTORED
AXIAL
4447 kg
SHEAR MOMENT
3716 kg 52991 kg-m
0.0 m
TORQUE 485 kg-m
2150.3
Grade
Size
18.0000
Face A Face B Face C 18.0000
(16) D50
13.0000 13.0000
12.0000 12.0000
Elevation (m)
6.0000 6.0000
0.0000 0.0000
12.0000 12.0000
Elevation (m)
6.0000 6.0000
0.0000 0.0000
12.0000 12.0000
Elevation (m)
6.0000 6.0000
0.0000 0.0000
610 mm
51 mm
1200 mm
FOUNDATION NOTES
1. Plate thickness is 38 mm.
825 mm 2. Plate grade is A36.
3. Anchor bolt grade is F1554-55.
4. f'c is 21000 kPa.
Options
Consider Moments - Legs Distribute Leg Loads As Uniform Treat Feedline Bundles As Cylinder
Consider Moments - Horizontals Assume Legs Pinned Use ASCE 10 X-Brace Ly Rules
Consider Moments - Diagonals √ Assume Rigid Index Plate √ Calculate Redundant Bracing Forces
Use Moment Magnification √ Use Clear Spans For Wind Area Ignore Redundant Members in FEA
√ Use Code Stress Ratios √ Use Clear Spans For KL/r SR Leg Bolts Resist Compression
√ Use Code Safety Factors - Guys √ Retension Guys To Initial Tension √ All Leg Panels Have Same Allowable
Escalate Ice Bypass Mast Stability Checks Offset Girt At Foundation
Always Use Max Kz √ Use Azimuth Dish Coefficients Consider Feedline Torque
Use Special Wind Profile √ Project Wind Area of Appurt. Include Angle Block Shear Check
√ Include Bolts In Member Capacity Autocalc Torque Arm Areas Poles
√ Leg Bolts Are At Top Of Section SR Members Have Cut Ends Include Shear-Torsion Interaction
√ Secondary Horizontal Braces Leg Sort Capacity Reports By Component Always Use Sub-Critical Flow
Use Diamond Inner Bracing (4 Sided) √ Triangulate Diamond Inner Bracing Use Top Mounted Sockets
Add IBC .6D+W Combination
Tower Gusset Gusset Gusset Grade Adjust. Factor Adjust. Weight Mult. Double Angle Double Angle
Elevation Area Thickness Af Factor Stitch Bolt Stitch Bolt
(per face) Ar Spacing Spacing
Diagonals Horizontals
m m2 mm mm mm
L1 1 1 1.3
18.0000-12.00
00
L2 1 1 1.3
12.0000-6.000
0
L3 1 1 1.3
6.0000-0.0000
Shielding Factor Ka
Tower Feed Line Description Feed Line Ka Ka
Section Record No. Segment Elev. No Ice Ice
Dishes
Description Face Dish Offset Offsets: Azimuth 3 dB Elevation Outside Aperture Weight
or Type Type Horz Adjustment Beam Diameter Area
Leg Lateral Width
Vert
m ° ° m m m2 kg
MW con radomo 0.60 C Paraboloid From 0.0000 0.0000 18.0000 0.6000 No Ice 0.2827 50.00
w/Radome Face 0.0000
0.0000
Force Totals
Load Vertical Sum of Sum of Sum of Sum of Sum of Torques
Case Forces Forces Forces Overturning Overturning
X Z Moments, Mx Moments, Mz
kg kg kg kg-m kg-m kg-m
Leg Weight 2150.32
Bracing Weight 0.00
Total Member Self-Weight 2150.32 539 0
Total Weight 3705.78 539 0
Wind 0 deg - No Ice 0.00 -2322.28 -31661 0 0
Wind 90 deg - No Ice 1967.18 -5.84 434 -27484 301
Wind 180 deg - No Ice 0.00 2314.73 32604 0 0
Total Weight 3705.78 539 0
Wind 0 deg - Service 0.00 -718.10 -9418 0 0
Wind 90 deg - Service 608.30 -1.81 507 -8499 93
Wind 180 deg - Service 0.00 715.77 10454 0 0
Job Page
RISATower Diseño de MP-18 8 of 12
Project Date
Sictteco Telecom SAS
Carrera 47 #53-18 MP Costa 18:17:53 04/09/20
Bogota Client Designed by
Phone: (57-1) 300 4895 ARBO
FAX: (57-1) 300 4895 René Garay
Load Combinations
Comb. Description
No.
1 Dead Only
2 1.2 Dead+1.6 Wind 0 deg - No Ice
3 0.9 Dead+1.6 Wind 0 deg - No Ice
4 1.2 Dead+1.6 Wind 90 deg - No Ice
5 0.9 Dead+1.6 Wind 90 deg - No Ice
6 1.2 Dead+1.6 Wind 180 deg - No Ice
7 0.9 Dead+1.6 Wind 180 deg - No Ice
8 Dead+Wind 0 deg - Service
9 Dead+Wind 90 deg - Service
10 Dead+Wind 180 deg - Service
Maximum Reactions
Location Condition Gov. Vertical Horizontal, X Horizontal, Z
Load kg kg kg
Comb.
Pole Max. Vert 6 4446.93 0.00 -3703.56
Max. Hx 10 3705.78 0.00 -715.77
Max. Hz 2 4446.93 0.00 3715.65
Max. Mx 2 51880 0.00 3715.65
Max. Mz 4 44869 -3147.49 9.34
Max. Torsion 1 0 0.00 -0.00
Job Page
RISATower Diseño de MP-18 9 of 12
Project Date
Sictteco Telecom SAS
Carrera 47 #53-18 MP Costa 18:17:53 04/09/20
Bogota Client Designed by
Phone: (57-1) 300 4895 ARBO
FAX: (57-1) 300 4895 René Garay
Solution Summary
Sum of Applied Forces Sum of Reactions
Load PX PY PZ PX PY PZ % Error
Comb. kg kg kg kg kg kg
1 0.00 -3705.78 0.00 0.00 3705.78 -0.00 0.000%
2 0.00 -4446.93 -3715.65 0.00 4446.93 3715.65 0.000%
3 0.00 -3335.20 -3715.65 0.00 3335.20 3715.65 0.000%
4 3147.49 -4446.93 -9.34 -3147.49 4446.93 9.34 0.000%
5 3147.49 -3335.20 -9.34 -3147.49 3335.20 9.34 0.000%
6 0.00 -4446.93 3703.56 0.00 4446.93 -3703.56 0.000%
7 0.00 -3335.20 3703.56 0.00 3335.20 -3703.56 0.000%
8 0.00 -3705.78 -718.10 0.00 3705.78 718.10 0.000%
9 608.30 -3705.78 -1.81 -608.30 3705.78 1.81 0.000%
10 0.00 -3705.78 715.77 0.00 3705.78 -715.77 0.000%
Compression Checks
Section Elevation Ratio Ratio Ratio Ratio Ratio Comb. Allow. Criteria
No. Pu Mux Muy Vu Tu Stress Stress
m Pn Mnx Mny Vn Tn Ratio Ratio
L1 18 - 12 (1) 0.014 0.621 0.000 0.035 0.000 0.636 1.000
4.8.2
Element Map
Section Section Component Element List
No. Elevation Type
m
L1 18.0000-12.000 Pole 1
0
L2 12.0000-6.0000 Pole 2
L3 6.0000-0.0000 Pole 3
Total number of elements: 3
Program Version 5.4.1.5 - 12/9/2014 File:C:/Carpeta RG/Sictteco Telecom 2020/01.Arbo/Nueva carpeta/00.Diseño de MP18/Modelo RisaTower v02/MP18
ARBO-CLARO v02.eri