MEMORIA DE CÁLCULO

MONOPOSTE H27 80 MPH


COLLOCATION COLOMBIA

MANUEL CORTES VASQUEZ


Ingeniero Civil

FECHA : 27/01/2020 REVISIÓN : 00 VERSIÓN : V1


INDICE

Pág.
1. OBJETIVOS ............................................................................................... 2
2. CONSIDERACIONES ..................................................................................... 2
2.1. INFORMACIÓN GENERAL.................................................................................................................. 2
2.2 MODELACIÓN .................................................................................................................................... 3
3. CÁLCULO DE LAS SOLICITACIONES ..................................................................... 4
4. VERIFICACIÓN ESTRUCTURAL .......................................................................... 5
4.1 TRAMOS MONOPOSTE. ..................................................................................................................... 5
4.2 PERNOS DE ANCLAJE. ........................................................................................................................ 5
5. CONCLUSIONES.......................................................................................... 5
MP Cónico 27 80 mph

1. OBJETIVOS

El presente informe contiene la verificación estructural de un Monoposte Cónico de 27 m de alto,


diseñado para solicitaciones de viento del tipo 80 Mph, frente a las cuales cumple para las cargas de diseño.

2. CONSIDERACIONES

2.1. INFORMACIÓN GENERAL.

La información contenida en este informe ha sido extraída de las siguientes fuentes:

▪ Norma para estructuras y torres de acero para telecomunicaciones, “TIA/EIA-222-G”, por


Telecommunications Industry Association.
▪ Norma AISC LRFD.
▪ Norma NSR10 Normas Colombianas de diseño y construcción sismo resistente.
▪ Guía de especificaciones técnicas entregadas por Cliente “Collocation Colombia”.

Las características estructurales del monoposte son presentadas a continuación:

▪ Monoposte tipo : Cónico, de sección poligonal uniforme de 12 lados.


▪ Unión de tramos : Tramos unidos mediante traslapes.
▪ Material planchas : Acero A36 (Fy=250 MPa).
▪ Material Brida : Acero A36 (Fy= 250 MPa).
▪ Pernos de anclaje : SAE 10-45 ó equivalente.
▪ Número de tramos : 5.
▪ Detalle de tramos : Detalle y disposición de tramos presentado en Tabla Nº1.

TABLA Nº1: DETALLE DE TRAMOS


Características
Largo Espesor Diámetro ext. Diámetro ext. Traslape con
Tramo inferior superior tramo anterior
[mm] [mm] [mm] [mm] [mm]
1 6000 8 600 600
2 6000 6 600 600
3 6000 6 500 500
4 6000 6 400 400
5 6000 6 380 380

Viento 80 mph – TIA/EIA 222-G

2
MP Cónico 27 80 mph

2.2 MODELACIÓN

Las características de las solicitaciones son:

▪ Presiones de viento de acuerdo a: 80 mph según TIA/EIA-222-G.


▪ Áreas de viento para estructura del monoposte, según TIA/EIA-222-G.
▪ Cargas debido a tipo, dimensiones y orientaciones de las antenas, según TIA/EIA-222-G.
▪ Antenas según, Tabla Nº2.

TABLA Nº2: DETALLE DE CARGAS

Consideraciones para cagas de viento sobre la estructura:

▪ Factor de probabilidad de la dirección del viento: Kd: 0.95


▪ Categoría de exposición: B
▪ Categoría topográfica: 1 (general)
▪ a:7
▪ Kzimn: 0.7
▪ Coeficientes de categoría Ke: 0.9
▪ Factor de importancia: I: 1.15
▪ Altura de la cresta sobre el terreno circundante: H= no aplica por categoría topográfica según
TIA EIA 222-G.

Viento 80 mph – TIA/EIA 222-G

3
MP Cónico 27 80 mph

Notas:

1. Según Norma TIA-EIA 222G, apartado 2.6.6.4 Factor topográfico, especifica que: Kzt = 1.0
para la categoría topográfica 1.

2. El Azimut corresponde al ángulo que define el plano que contiene a la dirección del viento
analizada con aquél que contiene a la cara de exposición de la antena.

3. Se ha considerado que la totalidad de los cables son concurrentes a un determinado grupo


de antenas se encuentran anclados al monoposte a la altura de esas antenas y por el interior
del monoposte, lo que equivale a aplicar el peso total de ellos a esa altura. Lo anterior
representa la situación más perjudicial para la estructura del monoposte.

3. CÁLCULO DE LAS SOLICITACIONES

Las solicitaciones de viento sobre los distintos elementos de la estructura y sus antenas, han sido
determinadas de acuerdo a las presiones de viento contenidas en la norma TIA/EIA-222-G, para 80 mph.

LRFD: La combinación de cargas “1.2*PP ± 1.6*Viento”, “0.9*PP ± 1.6*Viento” considera lo siguiente:

donde;

PP : Peso Propio de la estructura, accesorios y antenas.


VE : Cargas de viento debido a la estructura.
VA : Viento sobre las antenas y sus soportes.
VF : Viento sobre los feeders y escaleras.

La referencia “+/- Viento” establece dos sentidos de viento contrarios pero paralelos.

Viento 80 mph – TIA/EIA 222-G

4
MP Cónico 27 80 mph

4. VERIFICACIÓN ESTRUCTURAL
Se analizará el monoposte con sus antenas, para la solicitación de viento ya descrita, mediante el TN
Towers.

El método de diseño considerado corresponde al de resistencia ultima LRFD, el mismo sobre el cuál está
basada la norma TIA/EIA 222-G.

4.1 TRAMOS MONOPOSTE.

Se obtiene un Factor de Utilización máximo de 96.4 %, correspondiente al primer tramo del monoposte.
Ver Anexo A página 16.

4.2 PERNOS DE ANCLAJE.

VERIFICACIÓN PERNOS DE ANCLAJE (DIÁMETRO) Y UNIONES


f C irc.
Momento Perno T Adm. Nº de pernos Factor
C onexión Tipo perno Elemento pernos
2 Utilización
[kg-cm] Tipo Área [kg/cm ] [cm] Nec C oloc
Base-T1 SAE 1045 S1 5603400 1 1/4" 5.74 4238 70 13.2 16 82.2%

5. CONCLUSIONES

De acuerdo a la verificación estructural del monoposte, se puede concluir lo siguiente:

▪ La combinación de cargas solicitantes, ha determinado un Factor de Utilización máximo de 96.4


%, para un código de verificación por (LRFD) en el cuerpo del monopolo tramo 1.
▪ La cantidad (16), calidad (SAE1045) y/o los diámetros (1 ¼”) de pernos de anclaje son
suficientes para resistir las solicitaciones determinadas en este informe, estableciéndose un
Factor de Utilización máximo de 82.2 %.
▪ Las Reacciones máximas son (Anexo A, página 17):
- Momento : 56034 Kg*m.
- Corte : 2869 Kg.
- Axial : 5351 Kg.

La presente verificación sólo es válida para los tipos y disposición de antenas y cargas, correspondientes
a aquellos descritos en este informe.

Viento 80 mph – TIA/EIA 222-G

5
ANEXO A

1. Salida de programa.
2. Plano llave.
Job Page
tnxTower MP H27 80 MPH 1 of 16
Project Date
AJ INGENIEROS DE
GUATEMALA S.A. ESTRUCTURA TELECOMUNICACIONES 09:20:56 09/25/19
Km 26.5 Carretera a El Salvador Lote 30
GUATEMALA Client Designed by
Phone: (502) 66699074 COLLOCATION
FAX: AJ INGENIEROS

Tower Input Data

There is a pole section.


This tower is designed using the TIA-222-G standard.
The following design criteria apply:
Basic wind speed of 128.00 kph.
Structure Class II.
Exposure Category B.
Topographic Category 1.
Crest Height 0.00 m.
Deflections calculated using a wind speed of 96.00 kph.
Weld together tower sections have flange connections..
Connections use galvanized A325 bolts, nuts and locking devices. Installation per TIA/EIA-222 and AISC
Specifications..
Tower members are ''hot dipped'' galvanized in accordance with ASTM A123 and ASTM A153 Standards..
Welds are fabricated with ER-70S-6 electrodes..
A non-linear (P-delta) analysis was used.
Pressures are calculated at each section.
Stress ratio used in pole design is 1.
Local bending stresses due to climbing loads, feedline supports, and appurtenance mounts are not considered.

Options
Consider Moments - Legs Distribute Leg Loads As Uniform Treat Feedline Bundles As Cylinder
Consider Moments - Horizontals Assume Legs Pinned Use ASCE 10 X-Brace Ly Rules
Consider Moments - Diagonals √ Assume Rigid Index Plate √ Calculate Redundant Bracing Forces
Use Moment Magnification √ Use Clear Spans For Wind Area Ignore Redundant Members in FEA
√ Use Code Stress Ratios √ Use Clear Spans For KL/r SR Leg Bolts Resist Compression
√ Use Code Safety Factors - Guys √ Retension Guys To Initial Tension √ All Leg Panels Have Same Allowable
Escalate Ice Bypass Mast Stability Checks Offset Girt At Foundation
Always Use Max Kz √ Use Azimuth Dish Coefficients Consider Feedline Torque
Use Special Wind Profile √ Project Wind Area of Appurt. Include Angle Block Shear Check
√ Include Bolts In Member Capacity √ Autocalc Torque Arm Areas Poles
√ Leg Bolts Are At Top Of Section SR Members Have Cut Ends Include Shear-Torsion Interaction
√ Secondary Horizontal Braces Leg Sort Capacity Reports By Component Always Use Sub-Critical Flow
Use Diamond Inner Bracing (4 Sided) √ Triangulate Diamond Inner Bracing Use Top Mounted Sockets
Add IBC .6D+W Combination

Pole Section Geometry


Section Elevation Section Pole Pole Socket Length
Length Size Grade m
m m
L1 27.00-24.00 3.00 380*6mm A36 0.54
(248 MPa)
L2 23.46-17.46 6.00 400*6mm A36 0.61
(248 MPa)
L3 17.39-11.39 6.00 500*6 A36 0.67
(248 MPa)
Job Page
tnxTower MP H27 80 MPH 2 of 16
Project Date
AJ INGENIEROS DE
GUATEMALA S.A. ESTRUCTURA TELECOMUNICACIONES 09:20:56 09/25/19
Km 26.5 Carretera a El Salvador Lote 30
GUATEMALA Client Designed by
Phone: (502) 66699074 COLLOCATION
FAX: AJ INGENIEROS

Section Elevation Section Pole Pole Socket Length


Length Size Grade m
m m
L4 11.33-5.33 6.00 600*6 A36 0.74
(248 MPa)
L5 5.26-0.74 6.00 600*8 A36
(248 MPa)

Tower Gusset Gusset Gusset Grade Adjust. Factor Adjust. Weight Mult. Double Angle Double Angle
Elevation Area Thickness Af Factor Stitch Bolt Stitch Bolt
(per face) Ar Spacing Spacing
Diagonals Horizontals
m m2 mm mm mm
L1 27.00-24.00 1 1 1
L2 24.00-18.00 1 1 1
L3 18.00-12.00 1 1 1
L4 12.00-6.00 1 1 1
L5 6.00-0.00 1 1 1

Feed Line/Linear Appurtenances - Entered As Area


Description Face Allow Component Placement Total CAAA Weight
or Shield Type Number
Leg m m2/m kglm
12.7mm A No Inside Pole 24.50 - 0.00 20 No Ice 0.00 0.22
12.7mm A No Inside Pole 22.50 - 0.00 7 No Ice 0.00 0.22

Feed Line/Linear Appurtenances Section Areas


Tower Tower Face AR AF CAAA CAAA Weight
Section Elevation In Face Out Face
m m2 m2 m2 m2 kg
L1 27.00-24.00 A 0.000 0.000 0.000 0.000 2.20
B 0.000 0.000 0.000 0.000 0.00
C 0.000 0.000 0.000 0.000 0.00
L2 24.00-18.00 A 0.000 0.000 0.000 0.000 33.37
B 0.000 0.000 0.000 0.000 0.00
C 0.000 0.000 0.000 0.000 0.00
L3 18.00-12.00 A 0.000 0.000 0.000 0.000 35.68
B 0.000 0.000 0.000 0.000 0.00
C 0.000 0.000 0.000 0.000 0.00
L4 12.00-6.00 A 0.000 0.000 0.000 0.000 35.68
B 0.000 0.000 0.000 0.000 0.00
C 0.000 0.000 0.000 0.000 0.00
L5 6.00-0.00 A 0.000 0.000 0.000 0.000 35.68
B 0.000 0.000 0.000 0.000 0.00
C 0.000 0.000 0.000 0.000 0.00

Shielding Factor Ka
Job Page
tnxTower MP H27 80 MPH 3 of 16
Project Date
AJ INGENIEROS DE
GUATEMALA S.A. ESTRUCTURA TELECOMUNICACIONES 09:20:56 09/25/19
Km 26.5 Carretera a El Salvador Lote 30
GUATEMALA Client Designed by
Phone: (502) 66699074 COLLOCATION
FAX: AJ INGENIEROS

Tower Feed Line Description Feed Line Ka Ka


Section Record No. Segment Elev. No Ice Ice

Discrete Tower Loads


Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight
or Type Horz Adjustment Front Side
Leg Lateral
Vert
m ° m m2 m2 kg
m
m
(3) RF 1.5*0.4*0.15m A From Leg 0.40 0.00 27.00 No Ice 0.84 0.34 20.39
0.00
0.00
(3) RF 1.5*0.4*0.15m B From Leg 0.40 0.00 27.00 No Ice 0.84 0.34 20.39
0.00
0.00
(3) RF 1.5*0.4*0.15m C From Leg 0.40 0.00 27.00 No Ice 0.84 0.34 20.39
0.00
0.00
RF 1.5*0.4*0.15m A From Leg 0.40 0.00 23.00 No Ice 0.84 0.34 20.39
0.00
0.00
RF 1.5*0.4*0.15m B From Leg 0.40 0.00 23.00 No Ice 0.84 0.34 20.39
0.00
0.00
RF 1.5*0.4*0.15m C From Leg 0.40 0.00 23.00 No Ice 0.84 0.34 20.39
0.00
0.00
RF 1.5*0.4*0.15m A From Leg 0.40 0.00 18.00 No Ice 0.84 0.34 20.39
0.00
0.00
RF 1.5*0.4*0.15m B From Leg 0.40 0.00 18.00 No Ice 0.84 0.34 20.39
0.00
0.00
RF 1.5*0.4*0.15m C From Leg 0.40 0.00 18.00 No Ice 0.84 0.34 20.39
0.00
0.00
MB 0.7*0.6*0.48m B From Leg 0.20 0.00 9.00 No Ice 0.59 0.47 175.00
0.00
0.00
MR 0.7*0.6*0.48m C From Leg 0.20 0.00 9.00 No Ice 0.59 0.47 90.00
0.00
0.00
MB 0.7*0.6*0.48m B From Leg 0.20 0.00 10.50 No Ice 0.59 0.47 175.00
0.00
0.00
MR 0.7*0.6*0.48m C From Leg 0.20 0.00 10.50 No Ice 0.59 0.47 90.00
0.00
0.00
MB 0.7*0.6*0.48m B From Leg 0.20 0.00 12.00 No Ice 0.59 0.47 175.00
0.00
0.00
MR 0.7*0.6*0.48m C From Leg 0.20 0.00 12.00 No Ice 0.59 0.47 90.00
0.00
0.00
MB 0.7*0.6*0.48m B From Leg 0.20 0.00 13.50 No Ice 0.59 0.47 175.00
0.00
0.00
MR 0.7*0.6*0.48m C From Leg 0.20 0.00 13.50 No Ice 0.59 0.47 90.00
0.00
Job Page
tnxTower MP H27 80 MPH 4 of 16
Project Date
AJ INGENIEROS DE
GUATEMALA S.A. ESTRUCTURA TELECOMUNICACIONES 09:20:56 09/25/19
Km 26.5 Carretera a El Salvador Lote 30
GUATEMALA Client Designed by
Phone: (502) 66699074 COLLOCATION
FAX: AJ INGENIEROS

Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight


or Type Horz Adjustment Front Side
Leg Lateral
Vert
m ° m m2 m2 kg
m
m
0.00
Luminaria 31kg B From Leg 0.50 0.00 8.50 No Ice 0.17 0.08 31.00
0.00
0.00
Luminaria 31kg C From Leg 0.50 0.00 8.50 No Ice 0.17 0.08 31.00
0.00
0.00
Camara 10 kg B From Leg 0.20 0.00 8.00 No Ice 0.03 0.03 10.00
0.00
0.00
Camara 10 kg C From Leg 0.20 0.00 8.00 No Ice 0.03 0.03 10.00
0.00
0.00
(3) RRu 0.6*0.2*0.3m A From Leg 0.40 0.00 24.00 No Ice 0.17 0.25 35.00
0.00
0.00
(3) RRus 0.6*0.2*0.3m B From Leg 0.40 0.00 24.00 No Ice 0.17 0.25 35.69
0.00
0.00
(3) RRus 0.6*0.2*0.3m C From Leg 0.40 0.00 24.00 No Ice 0.17 0.25 35.69
0.00
0.00
RRus 0.6*0.2*0.3m A From Leg 0.40 0.00 19.00 No Ice 0.17 0.25 35.69
0.00
0.00
RRus 0.6*0.2*0.3m B From Leg 0.40 0.00 19.00 No Ice 0.17 0.25 35.69
0.00
0.00
RRus 0.6*0.2*0.3m C From Leg 0.40 0.00 19.00 No Ice 0.17 0.25 35.69
0.00
0.00
RRus 0.6*0.2*0.3m A From Leg 0.40 0.00 15.00 No Ice 0.17 0.25 35.69
0.00
0.00
RRus 0.6*0.2*0.3m B From Leg 0.40 0.00 15.00 No Ice 0.17 0.25 35.69
0.00
0.00
RRus 0.6*0.2*0.3m C From Leg 0.40 0.00 15.00 No Ice 0.17 0.25 35.69
0.00
0.00

Dishes
Description Face Dish Offset Offsets: Azimuth 3 dB Elevation Outside Aperture Weight
or Type Type Horz Adjustment Beam Diameter Area
Leg Lateral Width
Vert
m ° ° m m m2 kg
MW 0.6m A Paraboloid w/o From 0.40 0.00 27.00 0.60 No Ice 0.28 50.99
Radome Leg 0.00
0.00
Job Page
tnxTower MP H27 80 MPH 5 of 16
Project Date
AJ INGENIEROS DE
GUATEMALA S.A. ESTRUCTURA TELECOMUNICACIONES 09:20:56 09/25/19
Km 26.5 Carretera a El Salvador Lote 30
GUATEMALA Client Designed by
Phone: (502) 66699074 COLLOCATION
FAX: AJ INGENIEROS

Description Face Dish Offset Offsets: Azimuth 3 dB Elevation Outside Aperture Weight
or Type Type Horz Adjustment Beam Diameter Area
Leg Lateral Width
Vert
m ° ° m m m2 kg
MW 0.6m A Paraboloid w/o From 0.40 0.00 23.00 0.60 No Ice 0.28 50.99
Radome Leg 0.00
0.00
MW 0.6m A Paraboloid w/o From 0.40 0.00 18.00 0.60 No Ice 0.28 50.99
Radome Leg 0.00
0.00

Tower Pressures - No Ice


GH = 1.100

Section z KZ qz AG F AF AR Aleg Leg CAAA CAAA


Elevation a % In Out
c Face Face
m m kgsm m2 e m2 m2 m2 m2 m2
L1 27.00-24.00 25.50 0.939 70.54 1.140 A 0.000 1.140 1.140 100.00 0.000 0.000
B 0.000 1.140 100.00 0.000 0.000
C 0.000 1.140 100.00 0.000 0.000
L2 24.00-18.00 21.00 0.888 66.73 2.400 A 0.000 2.400 2.400 100.00 0.000 0.000
B 0.000 2.400 100.00 0.000 0.000
C 0.000 2.400 100.00 0.000 0.000
L3 18.00-12.00 15.00 0.807 60.62 3.000 A 0.000 3.000 3.000 100.00 0.000 0.000
B 0.000 3.000 100.00 0.000 0.000
C 0.000 3.000 100.00 0.000 0.000
L4 12.00-6.00 9.00 0.7 52.58 3.600 A 0.000 3.600 3.600 100.00 0.000 0.000
B 0.000 3.600 100.00 0.000 0.000
C 0.000 3.600 100.00 0.000 0.000
L5 6.00-0.00 3.00 0.7 52.58 3.600 A 0.000 3.600 3.600 100.00 0.000 0.000
B 0.000 3.600 100.00 0.000 0.000
C 0.000 3.600 100.00 0.000 0.000

Tower Pressure - Service


GH = 1.100

Section z KZ qz AG F AF AR Aleg Leg CAAA CAAA


Elevation a % In Out
c Face Face
m m kgsm m2 e m2 m2 m2 m2 m2
L1 27.00-24.00 25.50 0.939 35.50 1.140 A 0.000 1.140 1.140 100.00 0.000 0.000
B 0.000 1.140 100.00 0.000 0.000
C 0.000 1.140 100.00 0.000 0.000
L2 24.00-18.00 21.00 0.888 33.59 2.400 A 0.000 2.400 2.400 100.00 0.000 0.000
B 0.000 2.400 100.00 0.000 0.000
C 0.000 2.400 100.00 0.000 0.000
L3 18.00-12.00 15.00 0.807 30.51 3.000 A 0.000 3.000 3.000 100.00 0.000 0.000
B 0.000 3.000 100.00 0.000 0.000
C 0.000 3.000 100.00 0.000 0.000
L4 12.00-6.00 9.00 0.7 26.46 3.600 A 0.000 3.600 3.600 100.00 0.000 0.000
B 0.000 3.600 100.00 0.000 0.000
C 0.000 3.600 100.00 0.000 0.000
L5 6.00-0.00 3.00 0.7 26.46 3.600 A 0.000 3.600 3.600 100.00 0.000 0.000
Job Page
tnxTower MP H27 80 MPH 6 of 16
Project Date
AJ INGENIEROS DE
GUATEMALA S.A. ESTRUCTURA TELECOMUNICACIONES 09:20:56 09/25/19
Km 26.5 Carretera a El Salvador Lote 30
GUATEMALA Client Designed by
Phone: (502) 66699074 COLLOCATION
FAX: AJ INGENIEROS

Section z KZ qz AG F AF AR Aleg Leg CAAA CAAA


Elevation a % In Out
c Face Face
m m kgsm m2 e m2 m2 m2 m2 m2
B 0.000 3.600 100.00 0.000 0.000
C 0.000 3.600 100.00 0.000 0.000

Tower Forces - No Ice - Wind Normal To Face


Section Add Self F e CF qz DF DR AE F w Ctrl.
Elevation Weight Weight a Face
c kgsm
m kg kg e m2 kg kglm
L1 2.20 166.00 A 1 0.6 70.54 1 1 1.140 53.08 17.69 C
27.00-24.00 B 1 0.6 1 1 1.140
C 1 0.6 1 1 1.140
L2 33.37 349.76 A 1 0.6 66.73 1 1 2.400 105.71 17.62 C
24.00-18.00 B 1 0.6 1 1 2.400
C 1 0.6 1 1 2.400
L3 35.68 438.53 A 1 0.6 60.62 1 1 3.000 120.02 20.00 C
18.00-12.00 B 1 0.6 1 1 3.000
C 1 0.6 1 1 3.000
L4 12.00-6.00 35.68 527.30 A 1 0.6 52.58 1 1 3.600 124.93 20.82 C
B 1 0.6 1 1 3.600
C 1 0.6 1 1 3.600
L5 6.00-0.00 35.68 700.70 A 1 0.6 52.58 1 1 3.600 124.93 20.82 C
B 1 0.6 1 1 3.600
C 1 0.6 1 1 3.600
Sum Weight: 142.62 2182.28 OTM 6872.81 528.67
kg-m

Tower Forces - No Ice - Wind 60 To Face


Section Add Self F e CF qz DF DR AE F w Ctrl.
Elevation Weight Weight a Face
c kgsm
m kg kg e m2 kg kglm
L1 2.20 166.00 A 1 0.6 70.54 1 1 1.140 53.08 17.69 C
27.00-24.00 B 1 0.6 1 1 1.140
C 1 0.6 1 1 1.140
L2 33.37 349.76 A 1 0.6 66.73 1 1 2.400 105.71 17.62 C
24.00-18.00 B 1 0.6 1 1 2.400
C 1 0.6 1 1 2.400
L3 35.68 438.53 A 1 0.6 60.62 1 1 3.000 120.02 20.00 C
18.00-12.00 B 1 0.6 1 1 3.000
C 1 0.6 1 1 3.000
L4 12.00-6.00 35.68 527.30 A 1 0.6 52.58 1 1 3.600 124.93 20.82 C
B 1 0.6 1 1 3.600
C 1 0.6 1 1 3.600
L5 6.00-0.00 35.68 700.70 A 1 0.6 52.58 1 1 3.600 124.93 20.82 C
B 1 0.6 1 1 3.600
C 1 0.6 1 1 3.600
Sum Weight: 142.62 2182.28 OTM 6872.81 528.67
kg-m
Job Page
tnxTower MP H27 80 MPH 7 of 16
Project Date
AJ INGENIEROS DE
GUATEMALA S.A. ESTRUCTURA TELECOMUNICACIONES 09:20:56 09/25/19
Km 26.5 Carretera a El Salvador Lote 30
GUATEMALA Client Designed by
Phone: (502) 66699074 COLLOCATION
FAX: AJ INGENIEROS

Tower Forces - No Ice - Wind 90 To Face


Section Add Self F e CF qz DF DR AE F w Ctrl.
Elevation Weight Weight a Face
c kgsm
m kg kg e m2 kg kglm
L1 2.20 166.00 A 1 0.6 70.54 1 1 1.140 53.08 17.69 C
27.00-24.00 B 1 0.6 1 1 1.140
C 1 0.6 1 1 1.140
L2 33.37 349.76 A 1 0.6 66.73 1 1 2.400 105.71 17.62 C
24.00-18.00 B 1 0.6 1 1 2.400
C 1 0.6 1 1 2.400
L3 35.68 438.53 A 1 0.6 60.62 1 1 3.000 120.02 20.00 C
18.00-12.00 B 1 0.6 1 1 3.000
C 1 0.6 1 1 3.000
L4 12.00-6.00 35.68 527.30 A 1 0.6 52.58 1 1 3.600 124.93 20.82 C
B 1 0.6 1 1 3.600
C 1 0.6 1 1 3.600
L5 6.00-0.00 35.68 700.70 A 1 0.6 52.58 1 1 3.600 124.93 20.82 C
B 1 0.6 1 1 3.600
C 1 0.6 1 1 3.600
Sum Weight: 142.62 2182.28 OTM 6872.81 528.67
kg-m

Tower Forces - Service - Wind Normal To Face


Section Add Self F e CF qz DF DR AE F w Ctrl.
Elevation Weight Weight a Face
c kgsm
m kg kg e m2 kg kglm
L1 2.20 166.00 A 1 0.6 35.50 1 1 1.140 26.71 8.90 C
27.00-24.00 B 1 0.6 1 1 1.140
C 1 0.6 1 1 1.140
L2 33.37 349.76 A 1 0.6 33.59 1 1 2.400 53.20 8.87 C
24.00-18.00 B 1 0.6 1 1 2.400
C 1 0.6 1 1 2.400
L3 35.68 438.53 A 1 0.6 30.51 1 1 3.000 60.41 10.07 C
18.00-12.00 B 1 0.6 1 1 3.000
C 1 0.6 1 1 3.000
L4 12.00-6.00 35.68 527.30 A 1 0.6 26.46 1 1 3.600 62.88 10.48 C
B 1 0.6 1 1 3.600
C 1 0.6 1 1 3.600
L5 6.00-0.00 35.68 700.70 A 1 0.6 26.46 1 1 3.600 62.88 10.48 C
B 1 0.6 1 1 3.600
C 1 0.6 1 1 3.600
Sum Weight: 142.62 2182.28 OTM 3459.01 266.07
kg-m
Job Page
tnxTower MP H27 80 MPH 8 of 16
Project Date
AJ INGENIEROS DE
GUATEMALA S.A. ESTRUCTURA TELECOMUNICACIONES 09:20:56 09/25/19
Km 26.5 Carretera a El Salvador Lote 30
GUATEMALA Client Designed by
Phone: (502) 66699074 COLLOCATION
FAX: AJ INGENIEROS

Tower Forces - Service - Wind 60 To Face


Section Add Self F e CF qz DF DR AE F w Ctrl.
Elevation Weight Weight a Face
c kgsm
m kg kg e m2 kg kglm
L1 2.20 166.00 A 1 0.6 35.50 1 1 1.140 26.71 8.90 C
27.00-24.00 B 1 0.6 1 1 1.140
C 1 0.6 1 1 1.140
L2 33.37 349.76 A 1 0.6 33.59 1 1 2.400 53.20 8.87 C
24.00-18.00 B 1 0.6 1 1 2.400
C 1 0.6 1 1 2.400
L3 35.68 438.53 A 1 0.6 30.51 1 1 3.000 60.41 10.07 C
18.00-12.00 B 1 0.6 1 1 3.000
C 1 0.6 1 1 3.000
L4 12.00-6.00 35.68 527.30 A 1 0.6 26.46 1 1 3.600 62.88 10.48 C
B 1 0.6 1 1 3.600
C 1 0.6 1 1 3.600
L5 6.00-0.00 35.68 700.70 A 1 0.6 26.46 1 1 3.600 62.88 10.48 C
B 1 0.6 1 1 3.600
C 1 0.6 1 1 3.600
Sum Weight: 142.62 2182.28 OTM 3459.01 266.07
kg-m

Tower Forces - Service - Wind 90 To Face


Section Add Self F e CF qz DF DR AE F w Ctrl.
Elevation Weight Weight a Face
c kgsm
m kg kg e m2 kg kglm
L1 2.20 166.00 A 1 0.6 35.50 1 1 1.140 26.71 8.90 C
27.00-24.00 B 1 0.6 1 1 1.140
C 1 0.6 1 1 1.140
L2 33.37 349.76 A 1 0.6 33.59 1 1 2.400 53.20 8.87 C
24.00-18.00 B 1 0.6 1 1 2.400
C 1 0.6 1 1 2.400
L3 35.68 438.53 A 1 0.6 30.51 1 1 3.000 60.41 10.07 C
18.00-12.00 B 1 0.6 1 1 3.000
C 1 0.6 1 1 3.000
L4 12.00-6.00 35.68 527.30 A 1 0.6 26.46 1 1 3.600 62.88 10.48 C
B 1 0.6 1 1 3.600
C 1 0.6 1 1 3.600
L5 6.00-0.00 35.68 700.70 A 1 0.6 26.46 1 1 3.600 62.88 10.48 C
B 1 0.6 1 1 3.600
C 1 0.6 1 1 3.600
Sum Weight: 142.62 2182.28 OTM 3459.01 266.07
kg-m

Force Totals
Job Page
tnxTower MP H27 80 MPH 9 of 16
Project Date
AJ INGENIEROS DE
GUATEMALA S.A. ESTRUCTURA TELECOMUNICACIONES 09:20:56 09/25/19
Km 26.5 Carretera a El Salvador Lote 30
GUATEMALA Client Designed by
Phone: (502) 66699074 COLLOCATION
FAX: AJ INGENIEROS

Load Vertical Sum of Sum of Sum of Sum of Sum of Torques


Case Forces Forces Forces Overturning Overturning
X Z Moments, Mx Moments, Mz
kg kg kg kg-m kg-m kg-m
Leg Weight 2182.28
Bracing Weight 0.00
Total Member Self-Weight 2182.28 191.50 -139.86
Total Weight 4459.00 191.50 -139.86
Wind 0 deg - No Ice 0.00 -1762.13 -32625.05 -139.86 0.00
Wind 30 deg - No Ice 889.33 -1517.25 -28027.57 -16535.82 11.01
Wind 60 deg - No Ice 1526.56 -876.64 -16115.84 -28223.32 29.01
Wind 90 deg - No Ice 1751.15 -0.74 174.68 -32303.73 41.67
Wind 120 deg - No Ice 1513.05 951.52 18209.12 -27914.90 45.74
Wind 150 deg - No Ice 862.81 1566.35 29532.06 -15930.21 32.51
Wind 180 deg - No Ice 0.00 1793.31 33720.20 -139.86 0.00
Wind 210 deg - No Ice -862.81 1566.35 29532.06 15650.48 -32.51
Wind 240 deg - No Ice -1513.05 951.52 18209.12 27635.18 -45.74
Wind 270 deg - No Ice -1751.15 -0.74 174.68 32024.00 -41.67
Wind 300 deg - No Ice -1526.56 -876.64 -16115.84 27943.59 -29.01
Wind 330 deg - No Ice -889.33 -1517.25 -28027.57 16256.09 -11.01
Total Weight 4459.00 191.50 -139.86
Wind 0 deg - Service 0.00 -886.86 -16324.73 -139.86 0.00
Wind 30 deg - Service 447.59 -763.62 -14010.86 -8391.77 5.54
Wind 60 deg - Service 768.30 -441.21 -8015.81 -14273.97 14.60
Wind 90 deg - Service 881.34 -0.37 183.03 -16327.60 20.97
Wind 120 deg - Service 761.50 478.89 9259.58 -14118.75 23.02
Wind 150 deg - Service 434.24 788.33 14958.30 -8086.98 16.36
Wind 180 deg - Service 0.00 902.55 17066.14 -139.86 0.00
Wind 210 deg - Service -434.24 788.33 14958.30 7807.25 -16.36
Wind 240 deg - Service -761.50 478.89 9259.58 13839.02 -23.02
Wind 270 deg - Service -881.34 -0.37 183.03 16047.87 -20.97
Wind 300 deg - Service -768.30 -441.21 -8015.81 13994.24 -14.60
Wind 330 deg - Service -447.59 -763.62 -14010.86 8112.05 -5.54

Load Combinations
Comb. Description
No.
1 Dead Only
2 1.2 Dead+1.6 Wind 0 deg - No Ice
3 0.9 Dead+1.6 Wind 0 deg - No Ice
4 1.2 Dead+1.6 Wind 30 deg - No Ice
5 0.9 Dead+1.6 Wind 30 deg - No Ice
6 1.2 Dead+1.6 Wind 60 deg - No Ice
7 0.9 Dead+1.6 Wind 60 deg - No Ice
8 1.2 Dead+1.6 Wind 90 deg - No Ice
9 0.9 Dead+1.6 Wind 90 deg - No Ice
10 1.2 Dead+1.6 Wind 120 deg - No Ice
11 0.9 Dead+1.6 Wind 120 deg - No Ice
12 1.2 Dead+1.6 Wind 150 deg - No Ice
13 0.9 Dead+1.6 Wind 150 deg - No Ice
14 1.2 Dead+1.6 Wind 180 deg - No Ice
15 0.9 Dead+1.6 Wind 180 deg - No Ice
16 1.2 Dead+1.6 Wind 210 deg - No Ice
17 0.9 Dead+1.6 Wind 210 deg - No Ice
18 1.2 Dead+1.6 Wind 240 deg - No Ice
19 0.9 Dead+1.6 Wind 240 deg - No Ice
20 1.2 Dead+1.6 Wind 270 deg - No Ice
21 0.9 Dead+1.6 Wind 270 deg - No Ice
22 1.2 Dead+1.6 Wind 300 deg - No Ice
Job Page
tnxTower MP H27 80 MPH 10 of 16
Project Date
AJ INGENIEROS DE
GUATEMALA S.A. ESTRUCTURA TELECOMUNICACIONES 09:20:56 09/25/19
Km 26.5 Carretera a El Salvador Lote 30
GUATEMALA Client Designed by
Phone: (502) 66699074 COLLOCATION
FAX: AJ INGENIEROS

Comb. Description
No.
23 0.9 Dead+1.6 Wind 300 deg - No Ice
24 1.2 Dead+1.6 Wind 330 deg - No Ice
25 0.9 Dead+1.6 Wind 330 deg - No Ice
26 Dead+Wind 0 deg - Service
27 Dead+Wind 30 deg - Service
28 Dead+Wind 60 deg - Service
29 Dead+Wind 90 deg - Service
30 Dead+Wind 120 deg - Service
31 Dead+Wind 150 deg - Service
32 Dead+Wind 180 deg - Service
33 Dead+Wind 210 deg - Service
34 Dead+Wind 240 deg - Service
35 Dead+Wind 270 deg - Service
36 Dead+Wind 300 deg - Service
37 Dead+Wind 330 deg - Service

Maximum Member Forces


Section Elevation Component Condition Gov. Axial Major Axis Minor Axis
No. m Type Load Moment Moment
Comb. kg kg-m kg-m
L1 27 - 24 Pole Max Tension 14 0.01 0.01 0.00
Max. Compression 20 -431.15 2241.73 36.72
Max. Mx 8 -430.87 -2242.08 36.71
Max. My 2 -427.63 -0.21 2355.28
Max. Vy 8 796.17 -2242.08 36.71
Max. Vx 14 840.19 -0.21 -2337.04
Max. Torque 6 14.68
L2 24 - 18 Pole Max Tension 1 0.00 0.00 0.00
Max. Compression 20 -1506.80 10355.54 75.54
Max. Mx 8 -1506.26 -10358.30 75.53
Max. My 14 -1496.95 -1.48 -10898.66
Max. Vy 8 1546.54 -10358.30 75.53
Max. Vx 14 1634.11 -1.48 -10898.66
Max. Torque 6 27.06
L3 18 - 12 Pole Max Tension 1 0.00 0.00 0.00
Max. Compression 20 -2658.96 21873.92 45.70
Max. Mx 8 -2658.26 -21960.32 45.70
Max. My 14 -2649.57 -43.39 -23234.66
Max. Vy 8 2149.54 -21960.32 45.70
Max. Vx 14 2263.87 -43.39 -23234.66
Max. Torque 6 40.11
L4 12 - 6 Pole Max Tension 1 0.00 0.00 0.00
Max. Compression 20 -4411.79 36825.57 -214.91
Max. Mx 8 -4411.35 -37173.54 -214.91
Max. My 14 -4407.18 -174.24 -39099.74
Max. Vy 8 2694.71 -37173.54 -214.91
Max. Vx 14 2766.49 -174.24 -39099.74
Max. Torque 19 70.92
L5 6-0 Pole Max Tension 1 0.00 0.00 0.00
Max. Compression 22 -5349.00 46564.76 26909.34
Max. Mx 8 -5348.98 -53689.40 -209.06
Max. My 14 -5348.86 -175.35 -56034.10
Max. Vy 8 2804.38 -53689.40 -209.06
Max. Vx 14 2871.93 -175.35 -56034.10
Max. Torque 19 70.89
Job Page
tnxTower MP H27 80 MPH 11 of 16
Project Date
AJ INGENIEROS DE
GUATEMALA S.A. ESTRUCTURA TELECOMUNICACIONES 09:20:56 09/25/19
Km 26.5 Carretera a El Salvador Lote 30
GUATEMALA Client Designed by
Phone: (502) 66699074 COLLOCATION
FAX: AJ INGENIEROS

Maximum Reactions
Location Condition Gov. Vertical Horizontal, X Horizontal, Z
Load kg kg kg
Comb.
Pole Max. Vert 6 5350.80 -2442.45 1402.61
Max. Hx 21 4013.07 2801.25 1.18
Max. Hz 3 4013.07 0.00 2818.79
Max. Mx 2 54374.17 0.00 2818.53
Max. Mz 8 53689.40 -2800.99 1.18
Max. Torsion 19 70.86 2420.84 -1522.40
Min. Vert 15 4013.07 0.00 -2868.66
Min. Hx 9 4013.07 -2801.24 1.18
Min. Hz 15 4013.07 0.00 -2868.66
Min. Mx 14 -56034.10 0.00 -2868.39
Min. Mz 20 -53339.22 2800.99 1.18
Min. Torsion 11 -70.49 -2420.84 -1522.40

Tower Mast Reaction Summary


Load Vertical Shearx Shearz Overturning Overturning Torque
Combination Moment, Mx Moment, Mz
kg kg kg kg-m kg-m kg-m
Dead Only 4459.00 -0.21 -0.17 192.26 -140.07 -0.01
1.2 Dead+1.6 Wind 0 deg - No 5350.76 -0.00 -2818.53 -54374.17 -175.36 0.43
Ice
0.9 Dead+1.6 Wind 0 deg - No 4013.07 -0.00 -2818.79 -53880.58 -130.04 0.32
Ice
1.2 Dead+1.6 Wind 30 deg - No 5350.80 1422.89 -2427.56 -46738.20 -27464.48 16.20
Ice
0.9 Dead+1.6 Wind 30 deg - No 4013.10 1422.89 -2427.55 -46317.27 -27140.55 16.58
Ice
1.2 Dead+1.6 Wind 60 deg - No 5350.80 2442.45 -1402.61 -26909.52 -46915.91 43.48
Ice
0.9 Dead+1.6 Wind 60 deg - No 4013.10 2442.44 -1402.60 -26691.91 -46393.80 44.24
Ice
1.2 Dead+1.6 Wind 90 deg - No 5350.76 2800.99 -1.18 209.05 -53689.40 63.00
Ice
0.9 Dead+1.6 Wind 90 deg - No 4013.07 2801.24 -1.18 148.62 -53104.32 63.93
Ice
1.2 Dead+1.6 Wind 120 deg - 5350.80 2420.84 1522.41 30237.06 -46399.53 69.62
No Ice
0.9 Dead+1.6 Wind 120 deg - 4013.10 2420.84 1522.40 29866.86 -45883.11 70.49
No Ice
1.2 Dead+1.6 Wind 150 deg - 5350.80 1380.47 2506.12 49082.20 -26452.73 49.67
No Ice
0.9 Dead+1.6 Wind 150 deg - 4013.10 1380.47 2506.11 48519.45 -26139.88 50.24
No Ice
1.2 Dead+1.6 Wind 180 deg - 5350.76 -0.00 2868.39 56034.10 -175.35 -0.46
No Ice
0.9 Dead+1.6 Wind 180 deg - 4013.07 -0.00 2868.66 55406.36 -130.04 -0.34
No Ice
1.2 Dead+1.6 Wind 210 deg - 5350.80 -1380.47 2506.12 49082.45 26102.04 -50.49
No Ice
0.9 Dead+1.6 Wind 210 deg - 4013.10 -1380.47 2506.11 48519.63 25879.84 -50.84
No Ice
1.2 Dead+1.6 Wind 240 deg - 5350.80 -2420.84 1522.41 30237.34 46049.11 -70.13
No Ice
Job Page
tnxTower MP H27 80 MPH 12 of 16
Project Date
AJ INGENIEROS DE
GUATEMALA S.A. ESTRUCTURA TELECOMUNICACIONES 09:20:56 09/25/19
Km 26.5 Carretera a El Salvador Lote 30
GUATEMALA Client Designed by
Phone: (502) 66699074 COLLOCATION
FAX: AJ INGENIEROS

Load Vertical Shearx Shearz Overturning Overturning Torque


Combination Moment, Mx Moment, Mz
kg kg kg kg-m kg-m kg-m
0.9 Dead+1.6 Wind 240 deg - 4013.10 -2420.84 1522.40 29867.06 45623.27 -70.86
No Ice
1.2 Dead+1.6 Wind 270 deg - 5350.76 -2800.99 -1.18 209.05 53339.22 -63.02
No Ice
0.9 Dead+1.6 Wind 270 deg - 4013.07 -2801.25 -1.18 148.62 52844.63 -63.94
No Ice
1.2 Dead+1.6 Wind 300 deg - 5350.79 -2442.41 -1402.59 -26909.34 46564.76 -43.06
No Ice
0.9 Dead+1.6 Wind 300 deg - 4013.10 -2442.44 -1402.60 -26692.08 46133.95 -43.92
No Ice
1.2 Dead+1.6 Wind 330 deg - 5350.80 -1422.89 -2427.56 -46738.45 27113.79 -15.46
No Ice
0.9 Dead+1.6 Wind 330 deg - 4013.10 -1422.89 -2427.55 -46317.45 26880.50 -16.03
No Ice
Dead+Wind 0 deg - Service 4458.99 -0.00 -886.64 -16877.54 -145.12 0.11
Dead+Wind 30 deg - Service 4458.99 447.47 -763.42 -14485.28 -8674.42 5.16
Dead+Wind 60 deg - Service 4458.99 768.11 -441.10 -8287.80 -14753.96 13.84
Dead+Wind 90 deg - Service 4458.99 881.12 -0.37 187.93 -16876.27 20.03
Dead+Wind 120 deg - Service 4458.99 761.31 478.77 9572.93 -14593.10 22.14
Dead+Wind 150 deg - Service 4458.99 434.13 788.12 15463.37 -8358.61 15.79
Dead+Wind 180 deg - Service 4458.99 -0.00 902.32 17642.17 -145.12 -0.13
Dead+Wind 210 deg - Service 4458.99 -434.14 788.12 15463.39 8068.39 -16.01
Dead+Wind 240 deg - Service 4458.99 -761.32 478.77 9572.95 14302.90 -22.28
Dead+Wind 270 deg - Service 4459.00 -881.12 -0.37 187.93 16586.08 -20.05
Dead+Wind 300 deg - Service 4458.99 -768.11 -441.10 -8287.82 14463.76 -13.74
Dead+Wind 330 deg - Service 4458.99 -447.48 -763.42 -14485.30 8384.19 -4.98

Solution Summary
Sum of Applied Forces Sum of Reactions
Load PX PY PZ PX PY PZ % Error
Comb. kg kg kg kg kg kg
1 0.00 -4459.00 0.00 0.21 4459.00 0.17 0.006%
2 0.00 -5350.80 -2819.40 0.00 5350.76 2818.53 0.015%
3 0.00 -4013.10 -2819.40 0.00 4013.07 2818.79 0.013%
4 1422.92 -5350.80 -2427.60 -1422.89 5350.80 2427.56 0.001%
5 1422.92 -4013.10 -2427.60 -1422.89 4013.10 2427.55 0.001%
6 2442.49 -5350.80 -1402.63 -2442.45 5350.80 1402.61 0.001%
7 2442.49 -4013.10 -1402.63 -2442.44 4013.10 1402.60 0.001%
8 2801.85 -5350.80 -1.18 -2800.99 5350.76 1.18 0.014%
9 2801.85 -4013.10 -1.18 -2801.24 4013.07 1.18 0.012%
10 2420.89 -5350.80 1522.44 -2420.84 5350.80 -1522.41 0.001%
11 2420.89 -4013.10 1522.44 -2420.84 4013.10 -1522.40 0.001%
12 1380.50 -5350.80 2506.16 -1380.47 5350.80 -2506.12 0.001%
13 1380.50 -4013.10 2506.16 -1380.47 4013.10 -2506.11 0.001%
14 0.00 -5350.80 2869.29 0.00 5350.76 -2868.39 0.015%
15 0.00 -4013.10 2869.29 0.00 4013.07 -2868.66 0.013%
16 -1380.50 -5350.80 2506.16 1380.47 5350.80 -2506.12 0.001%
17 -1380.50 -4013.10 2506.16 1380.47 4013.10 -2506.11 0.001%
18 -2420.89 -5350.80 1522.44 2420.84 5350.80 -1522.41 0.001%
19 -2420.89 -4013.10 1522.44 2420.84 4013.10 -1522.40 0.001%
20 -2801.85 -5350.80 -1.18 2800.99 5350.76 1.18 0.014%
21 -2801.85 -4013.10 -1.18 2801.25 4013.07 1.18 0.012%
22 -2442.49 -5350.80 -1402.63 2442.41 5350.79 1402.59 0.001%
23 -2442.49 -4013.10 -1402.63 2442.44 4013.10 1402.60 0.001%
24 -1422.92 -5350.80 -2427.60 1422.89 5350.80 2427.56 0.001%
25 -1422.92 -4013.10 -2427.60 1422.89 4013.10 2427.55 0.001%
26 0.00 -4459.00 -886.86 0.00 4458.99 886.64 0.005%
Job Page
tnxTower MP H27 80 MPH 13 of 16
Project Date
AJ INGENIEROS DE
GUATEMALA S.A. ESTRUCTURA TELECOMUNICACIONES 09:20:56 09/25/19
Km 26.5 Carretera a El Salvador Lote 30
GUATEMALA Client Designed by
Phone: (502) 66699074 COLLOCATION
FAX: AJ INGENIEROS

Sum of Applied Forces Sum of Reactions


Load PX PY PZ PX PY PZ % Error
Comb. kg kg kg kg kg kg
27 447.59 -4459.00 -763.62 -447.47 4458.99 763.42 0.005%
28 768.30 -4459.00 -441.21 -768.11 4458.99 441.10 0.005%
29 881.34 -4459.00 -0.37 -881.12 4458.99 0.37 0.005%
30 761.50 -4459.00 478.89 -761.31 4458.99 -478.77 0.005%
31 434.24 -4459.00 788.33 -434.13 4458.99 -788.12 0.005%
32 0.00 -4459.00 902.55 0.00 4458.99 -902.32 0.005%
33 -434.24 -4459.00 788.33 434.14 4458.99 -788.12 0.005%
34 -761.50 -4459.00 478.89 761.32 4458.99 -478.77 0.005%
35 -881.34 -4459.00 -0.37 881.12 4459.00 0.37 0.005%
36 -768.30 -4459.00 -441.21 768.11 4458.99 441.10 0.005%
37 -447.59 -4459.00 -763.62 447.48 4458.99 763.42 0.005%

Non-Linear Convergence Results


Load Converged? Number Displacement Force
Combination of Cycles Tolerance Tolerance
1 Yes 6 0.00000001 0.00001429
2 Yes 17 0.00014805 0.00012800
3 Yes 17 0.00010382 0.00011113
4 Yes 22 0.00000001 0.00008843
5 Yes 21 0.00000001 0.00012335
6 Yes 22 0.00000001 0.00008713
7 Yes 21 0.00000001 0.00012164
8 Yes 17 0.00014817 0.00014420
9 Yes 17 0.00010394 0.00012490
10 Yes 22 0.00000001 0.00010045
11 Yes 21 0.00000001 0.00013979
12 Yes 22 0.00000001 0.00008895
13 Yes 21 0.00000001 0.00012334
14 Yes 17 0.00014778 0.00013080
15 Yes 17 0.00010363 0.00011306
16 Yes 22 0.00000001 0.00008729
17 Yes 21 0.00000001 0.00012161
18 Yes 22 0.00000001 0.00009923
19 Yes 21 0.00000001 0.00013851
20 Yes 17 0.00014822 0.00014320
21 Yes 17 0.00010397 0.00012426
22 Yes 21 0.00000001 0.00014931
23 Yes 21 0.00000001 0.00012053
24 Yes 22 0.00000001 0.00008687
25 Yes 21 0.00000001 0.00012171
26 Yes 17 0.00000001 0.00004599
27 Yes 17 0.00000001 0.00004217
28 Yes 17 0.00000001 0.00004331
29 Yes 17 0.00000001 0.00004623
30 Yes 17 0.00000001 0.00004968
31 Yes 17 0.00000001 0.00004215
32 Yes 17 0.00000001 0.00004769
33 Yes 17 0.00000001 0.00004139
34 Yes 17 0.00000001 0.00004823
35 Yes 17 0.00000001 0.00004538
36 Yes 17 0.00000001 0.00004218
37 Yes 17 0.00000001 0.00004143
Job Page
tnxTower MP H27 80 MPH 14 of 16
Project Date
AJ INGENIEROS DE
GUATEMALA S.A. ESTRUCTURA TELECOMUNICACIONES 09:20:56 09/25/19
Km 26.5 Carretera a El Salvador Lote 30
GUATEMALA Client Designed by
Phone: (502) 66699074 COLLOCATION
FAX: AJ INGENIEROS

Maximum Tower Deflections - Service Wind


Section Elevation Horz. Gov. Tilt Twist
No. Deflection Load
m mm Comb. ° °
L1 27 - 24 363.79 32 1.28 0.00
L2 24 - 18 297.10 32 1.26 0.00
L3 18 - 12 174.59 32 1.03 0.00
L4 12 - 6 80.98 32 0.72 0.00
L5 6-0 21.47 32 0.39 0.00

Critical Deflections and Radius of Curvature - Service Wind


Elevation Appurtenance Gov. Deflection Tilt Twist Radius of
Load Curvature
m Comb. mm ° ° m
27.00 MW 0.6m 32 363.79 1.28 0.00 6094
24.00 (3) RRu 0.6*0.2*0.3m 32 297.10 1.26 0.00 3108
23.00 MW 0.6m 32 275.33 1.24 0.00 2350
19.00 RRus 0.6*0.2*0.3m 32 193.32 1.08 0.00 1199
18.00 MW 0.6m 32 174.59 1.03 0.00 1102
15.00 RRus 0.6*0.2*0.3m 32 123.81 0.88 0.00 1130
13.50 MB 0.7*0.6*0.48m 32 101.42 0.80 0.00 1155
12.00 MB 0.7*0.6*0.48m 32 80.98 0.72 0.00 1145
10.50 MB 0.7*0.6*0.48m 32 62.50 0.64 0.00 1021
9.00 MB 0.7*0.6*0.48m 32 46.23 0.56 0.00 901
8.50 Luminaria 31kg 32 41.34 0.53 0.00 866
8.00 Camara 10 kg 32 36.75 0.50 0.00 835

Maximum Tower Deflections - Design Wind


Section Elevation Horz. Gov. Tilt Twist
No. Deflection Load
m mm Comb. ° °
L1 27 - 24 1160.19 14 4.11 0.01
L2 24 - 18 946.63 14 4.03 0.00
L3 18 - 12 555.01 14 3.29 0.00
L4 12 - 6 256.99 14 2.29 0.00
L5 6-0 68.17 14 1.23 0.00

Critical Deflections and Radius of Curvature - Design Wind


Elevation Appurtenance Gov. Deflection Tilt Twist Radius of
Load Curvature
m Comb. mm ° ° m
27.00 MW 0.6m 14 1160.19 4.11 0.01 1987
24.00 (3) RRu 0.6*0.2*0.3m 14 946.63 4.03 0.00 1011
23.00 MW 0.6m 14 876.97 3.96 0.00 760
19.00 RRus 0.6*0.2*0.3m 14 614.78 3.44 0.00 381
Job Page
tnxTower MP H27 80 MPH 15 of 16
Project Date
AJ INGENIEROS DE
GUATEMALA S.A. ESTRUCTURA TELECOMUNICACIONES 09:20:56 09/25/19
Km 26.5 Carretera a El Salvador Lote 30
GUATEMALA Client Designed by
Phone: (502) 66699074 COLLOCATION
FAX: AJ INGENIEROS

Elevation Appurtenance Gov. Deflection Tilt Twist Radius of


Load Curvature
m Comb. mm ° ° m
18.00 MW 0.6m 14 555.01 3.29 0.00 349
15.00 RRus 0.6*0.2*0.3m 14 393.19 2.79 0.00 353
13.50 MB 0.7*0.6*0.48m 14 321.96 2.54 0.00 360
12.00 MB 0.7*0.6*0.48m 14 256.99 2.29 0.00 358
10.50 MB 0.7*0.6*0.48m 14 198.32 2.03 0.00 320
9.00 MB 0.7*0.6*0.48m 14 146.68 1.77 0.00 283
8.50 Luminaria 31kg 14 131.19 1.69 0.00 273
8.00 Camara 10 kg 14 116.62 1.60 0.00 263

Compression Checks

Pole Design Data


Section Elevation Size L Lu Kl/r A Pu Pn Ratio
No. Pu
m m m mm2 kg kg Pn
L1 27 - 24 (1) 380*6mm 3.00 27.00 204.2 7049.73 -427.63 26862.61 0.016
L2 24 - 18 (2) 400*6mm 6.00 27.00 193.8 7426.69 -1496.96 31405.88 0.048
L3 18 - 12 (3) 500*6 6.00 27.00 154.6 9311.66 -2649.57 61896.78 0.043
L4 12 - 6 (4) 600*6 6.00 27.00 128.6 11196.6 -4407.18 106420.96 0.041
2
L5 6 - 0 (5) 600*8 6.00 27.00 129.0 14878.5 -5348.85 141160.25 0.038
5

Pole Bending Design Data


Section Elevation Size Mux Mnx Ratio Muy Mny Ratio
No. Mux Muy
m kg-m kg-m Mnx kg-m kg-m Mny
L1 27 - 24 (1) 380*6mm 2355.28 18673.76 0.126 0.00 18673.76 0.000
L2 24 - 18 (2) 400*6mm 10898.66 20524.30 0.531 0.00 20524.30 0.000
L3 18 - 12 (3) 500*6 23234.67 31065.44 0.748 0.00 31065.44 0.000
L4 12 - 6 (4) 600*6 39100.13 43753.67 0.894 0.00 43753.67 0.000
L5 6 - 0 (5) 600*8 56034.40 60507.07 0.926 0.00 60507.07 0.000

Pole Shear Design Data


Section Elevation Size Actual Vn Ratio Actual Tn Ratio
No. Vu Vu Tu Tu
m kg kg Vn kg-m kg-m Tn
L1 27 - 24 (1) 380*6mm 822.04 80294.49 0.010 0.01 29563.64 0.000
L2 24 - 18 (2) 400*6mm 1634.12 84588.20 0.019 0.01 32835.56 0.000
L3 18 - 12 (3) 500*6 2263.87 106057.64 0.021 0.20 51771.31 0.000
L4 12 - 6 (4) 600*6 2766.49 123952.31 0.022 0.46 72898.86 0.000
L5 6 - 0 (5) 600*8 2871.93 169463.06 0.017 0.46 99002.56 0.000
Job Page
tnxTower MP H27 80 MPH 16 of 16
Project Date
AJ INGENIEROS DE
GUATEMALA S.A. ESTRUCTURA TELECOMUNICACIONES 09:20:56 09/25/19
Km 26.5 Carretera a El Salvador Lote 30
GUATEMALA Client Designed by
Phone: (502) 66699074 COLLOCATION
FAX: AJ INGENIEROS

Section Elevation Size Actual Vn Ratio Actual Tn Ratio


No. Vu Vu Tu Tu
m kg kg Vn kg-m kg-m Tn

Pole Interaction Design Data


Section Elevation Ratio Ratio Ratio Ratio Ratio Comb. Allow. Criteria
No. Pu Mux Muy Vu Tu Stress Stress
m Pn Mnx Mny Vn Tn Ratio Ratio
L1 27 - 24 (1) 0.016 0.126 0.000 0.010 0.000 0.142 1.000
4.8.2

L2 24 - 18 (2) 0.048 0.531 0.000 0.019 0.000 0.579 1.000


4.8.2

L3 18 - 12 (3) 0.043 0.748 0.000 0.021 0.000 0.791 1.000


4.8.2

L4 12 - 6 (4) 0.041 0.894 0.000 0.022 0.000 0.936 1.000


4.8.2

L5 6 - 0 (5) 0.038 0.926 0.000 0.017 0.000 0.964 1.000


4.8.2

Section Capacity Table


Section Elevation Component Size Critical P øPallow % Pass
No. m Type Element kg kg Capacity Fail
L1 27 - 24 Pole 380*6mm 1 -427.63 26862.61 14.2 Pass
L2 24 - 18 Pole 400*6mm 2 -1496.96 31405.88 57.9 Pass
L3 18 - 12 Pole 500*6 3 -2649.57 61896.78 79.1 Pass
L4 12 - 6 Pole 600*6 4 -4407.18 106420.96 93.6 Pass
L5 6-0 Pole 600*8 5 -5348.85 141160.25 96.4 Pass
Summary
Pole (L5) 96.4 Pass
RATING = 96.4 Pass


Program Version 6.0.0.8 - 9/7/2011 File:C:/Users/epa/Desktop/MP H27 COLLOCATION V250919/MPH27.eri
27.0 m
(3) RRu
RF
MW
RRus
MB
MR
Luminaria
Camara
RF
RRus
1.5*0.4*0.15m
0.7*0.6*0.48m
0.6m
0.6*0.2*0.3m
1.5*0.4*0.15m
0.6*0.2*0.3m
10
0.6*0.2*0.3m
31kg
kg
DESIGNED
27
24
23
19
18
15
13.5
12
10.5
9
8.5
8
APPURTENANCE LOADING
TYPE ELEVATION TYPE ELEVATION
380*6mm

(3) RF 1.5*0.4*0.15m 27 MW 0.6m 18

166.0
3.00

0.54
1

(3) RF 1.5*0.4*0.15m 27 RRus 0.6*0.2*0.3m 15


(3) RF 1.5*0.4*0.15m 27 RRus 0.6*0.2*0.3m 15
MW 0.6m 27 RRus 0.6*0.2*0.3m 15
24.0 m (3) RRu 0.6*0.2*0.3m 24 MB 0.7*0.6*0.48m 13.5
(3) RRus 0.6*0.2*0.3m 24 MR 0.7*0.6*0.48m 13.5
(3) RRus 0.6*0.2*0.3m 24 MR 0.7*0.6*0.48m 12
RF 1.5*0.4*0.15m 23 MB 0.7*0.6*0.48m 12
RF 1.5*0.4*0.15m 23 MR 0.7*0.6*0.48m 10.5
RF 1.5*0.4*0.15m 23 MB 0.7*0.6*0.48m 10.5
MW 0.6m 23 MB 0.7*0.6*0.48m 9
RRus 0.6*0.2*0.3m 19 MR 0.7*0.6*0.48m 9
400*6mm

RRus 0.6*0.2*0.3m 19 Luminaria 31kg 8.5


349.8
6.00

0.61
2

RRus 0.6*0.2*0.3m 19 Luminaria 31kg 8.5


RF 1.5*0.4*0.15m 18 Camara 10 kg 8
RF 1.5*0.4*0.15m 18 Camara 10 kg 8
RF 1.5*0.4*0.15m 18

MATERIAL STRENGTH
GRADE Fy Fu GRADE Fy Fu
18.0 m A36 248 MPa 400 MPa

TOWER DESIGN NOTES


1. Tower designed for Exposure B to the TIA-222-G Standard.
A36

2. Tower designed for a 128.00 kph basic wind in accordance with the TIA-222-G Standard.
3. Deflections are based upon a 96.00 kph wind.
4. Tower Structure Class II.
5. Topographic Category 1 with Crest Height of 0.00 m
500*6

438.5
6.00

0.67
3

6. Weld together tower sections have flange connections.


7. Connections use galvanized A325 bolts, nuts and locking devices. Installation per
TIA/EIA-222 and AISC Specifications.
8. Tower members are "hot dipped" galvanized in accordance with ASTM A123 and ASTM A153
Standards.
9. Welds are fabricated with ER-70S-6 electrodes.
10. TOWER RATING: 96.4%
12.0 m
600*6

527.3
6.00

0.74
4

6.0 m

ALL REACTIONS
600*8

700.7
6.00

ARE FACTORED
5

AXIAL
5351 kg

SHEAR MOMENT
2869 kg 56034 kg-m
0.0 m
TORQUE 71 kg-m
2182.3

REACTIONS - 128.00 kph WIND


Socket Length (m)

Weight (kg)
Length (m)
Section

Grade
Size

AJ INGENIEROS DE GUATEMALA S.A. Job: MP H27 80 MPH


Project: ESTRUCTURA
Km 26.5 Carretera a El Salvador Lote 30 TELECOMUNICACIONES
Client:
GUATEMALA COLLOCATION Drawn by: AJ INGENIEROS App'd:
Code: Date: Scale:
Phone: (502) 66699074 TIA-222-G 09/25/19 NTS
Path: Dwg No.
FAX: C:\Users\epa\Desktop\MP H27 COLLOCATION V250919\MPH27.eri E-1
FECHA: PLANO:

13 CALLE 3-40 ZONA 10 EDIF. ATLANTIS


A. J. INGENIEROS DE GUATEMALA S.A.
TELEFONO :2363-2267 - 69 - 70

NIVEL 5 OFICINA 508


COLLOCATION
GUATEMALA C.A.
ESPECIFICACIONES DE MONOPOSTE

MONOPOSTE ALTURA 27M VIENTO 80MPH

INGENIEROS LTDA.
AJ
EMPRESA:
ANTENAS

1 DE 1
MONOPOSTE H27 MTS. 80MPH
CANTIDAD ELEV. (M) DESCRIPCION AZIMUT

LAMINA
9 27 RF 1.5X0.4MX0.15M. 0º 120º 240º

ARCHIVO CAD:
1 27 MMOO 0.6M

IND.

ESCALA
9

MES REVISION:
24 RRU 0.6X0.2X0.3M. 0º 120º 240º

SEP.
3 23 RF 1.5X0.4MX0.15M. 0º 120º 240º

25-09-19
1 23 MMOO 0.6M 0º

FECHA
3 0º 120º 240º

REVISION:
19 RRU 0.6X0.2X0.3M.

SITIO:
3 18 RF 1.5X0.4MX0.15M. 0º 120º 240º
1 18 MMOO 0.6M 0º

GERENTE GENERAL

MANUEL CORTES
RAUL SAGREDO
3 15 RRU 0.6X0.2X0.3M. 0º 120º 240º
2 13.5 MR 0.7X0.6X0.48M.

CORDINADOR:
16 PERNOS 7/8"
2 12 MR 0.7X0.6X0.48M.

DIBUJO:
2 10.5 MR 0.7X0.6X0.48M.
2 9 MR 0.7X0.6X0.48M.

MANUEL CORTES

ING. CIVIL
2 8.5 LUMINARIA

PROFESIONAL A CARGO:
2 8 CAMARA

PARAMETROS DE DISEÑO
FACTOR DE PROBABILIDAD DEL VIENTO Kd 0.95
CLASIFICACIÓN DE ESTRUCTURA CLASE II
16 PERNOS 7/8" FACTOR DE IMPORTANCIA 1
CATEGORIA EXPOSICIÓN CATEGORIA B
CATEGORIA TOPOGRAFICA CATEGORIA 1

MATERIALES
DESCRIPCION CALIDAD FLUENCIA
PLANCHAS A 36 250 MPA
ACCESORIOS A 36 250 MPA
PERNOS DE ANCLAJE C45K 310 MPA

DISEÑO
FACTOR DE UTILIZACIÓN 96.4%

16 PERNOS 7/8"

16 PERNOS 1"
REACTIONS AT BASE

AXIAL: 5351 KG

MOMENT:56034 KG-M
16 PERNOS 1 1/4"
SHEAR: 2869 KG