Está en la página 1de 6

VARIACIONES DEL CONSUMO DEL AGUA

Sistema de Agua Potable San Buenaventura


Ejemplo de cálcu
Demanda Consumo % Diferencias
Horas
Horaria en el Intervalo Producción + -
0 1 45 1.88 4.17 2.29
1 2 45 1.88 4.17 2.29
2 3 45 1.88 4.17 2.29
3 4 45 1.88 4.17 2.29
4 5 45 1.88 4.17 2.29
5 6 60 2.50 4.17 1.67
6 7 90 3.75 4.17 0.42
7 8 135 5.63 4.17 -1.46
8 9 150 6.25 4.17 -2.08
9 10 150 6.25 4.17 -2.08
10 11 150 6.25 4.17 -2.08
11 12 140 5.83 4.17 -1.67
12 13 120 5.00 4.17 -0.83
13 14 140 5.83 4.17 -1.67
14 15 140 5.83 4.17 -1.67
15 16 130 5.42 4.17 -1.25
16 17 130 5.42 4.17 -1.25
17 18 120 5.00 4.17 -0.83
18 19 100 4.17 4.17 0.00
19 20 100 4.17 4.17 0.00
20 21 90 3.75 4.17 0.42
21 22 90 3.75 4.17 0.42
22 23 80 3.33 4.17 0.83
23 24 60 2.50 4.17 1.67
Total 2,400 100.00 100.00 16.88 -16.88
Fuente: SGI - EPYPSA

Variación de Consumo de agua

7.0
6.3 6.3 6.3
5.8 5.8 5.8
5.6
Consumo horario, %

6.0 5.4 5.4


5.0 5.0
5.0
4.2 4.2
3.8 3.8 3.8
4.0 3.3

3.0 2.5 2.5

1.9 1.9 1.9 1.9 1.9


2.0

1.0

0.0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

Tiempo, horas
variación de consumo

T-1 Cálculo Caudales Agua V 5.1 San Buenaventura Página 1


Sistema de Agua Potable San Buenaventura
DIAGRAMA DE MASAS (RIPPLE)
LEY DE DEMANDAS Y HORARIOS PARA POBLACIONES MENORES

Demanda Diferencia
Q máx dia Diferencia Demanda
Horas Horaria Acumulada Observaciones
(%) (%) Acumulada
(%) (%)
0 1 100.00 45 45 15.63 Demanda en m3/hr
1 2 100.00 45 90 31.26
2 3 100.00 45 135 46.88
3 4 100.00 45 180 62.51
4 5 100.00 45 225 78.14
5 6 100.00 60 285 98.98
6 7 100.00 90 375 130.24
7 8 100.00 135 510 177.12
8 9 100.00 150 660 229.21
9 10 100.00 150 810 281.31
10 11 100.00 150 960 333.40
11 12 100.00 140 1,100 382.02
12 13 100.00 120 1,220 423.70
13 14 100.00 140 1,360 472.32
14 15 100.00 140 1,500 520.94
15 16 100.00 130 1,630 566.09
16 17 100.00 130 1,760 611.24
17 18 100.00 120 1,880 652.91
18 19 100.00 100 1,980 687.64
19 20 100.00 100 2,080 722.37
20 21 100.00 90 2,170 753.63
21 22 100.00 90 2,260 784.88
22 23 100.00 80 2,340 812.67
23 24 100.00 60 2,400 833.50
Fuente: SGI - EPYPSA

Sistema de Agua Potable San Buenaventura


VARIACION DE VOLUMEN EN EL RESERVORIO

Diferencia Volumen del Reservorio


Demanda Q máx Diario
Horas Qd-Dh Total (r+r´) Observaciones
Horaria (m3/hr) (m3/hr) Regulación (m3)
(m3/hr) (m3)
0 1 15.63 34.73 19.10 46.88 155.24
1 2 15.63 34.73 19.10 65.99 174.34
2 3 15.63 34.73 19.10 85.09 193.44
3 4 15.63 34.73 19.10 104.19 212.54
4 5 15.63 34.73 19.10 123.29 231.64
5 6 20.84 34.73 13.89 137.18 245.54
6 7 31.26 34.73 3.47 140.65 249.01 Volumen Util (m3)
7 8 46.88 34.73 -12.16 128.50 236.85
8 9 52.09 34.73 -17.36 111.13 219.49
9 10 52.09 34.73 -17.36 93.77 202.12
10 11 52.09 34.73 -17.36 76.40 184.76
11 12 48.62 34.73 -13.89 62.51 170.87
12 13 41.68 34.73 -6.95 55.57 163.92
13 14 48.62 34.73 -13.89 41.68 150.03
14 15 48.62 34.73 -13.89 27.78 136.14
15 16 45.15 34.73 -10.42 17.36 125.72
16 17 45.15 34.73 -10.42 6.95 115.30
17 18 41.68 34.73 -6.95 0.00 108.36
18 19 34.73 34.73 0.00 0.00 108.36
19 20 34.73 34.73 0.00 0.00 108.36
20 21 31.26 34.73 3.47 3.47 111.83
21 22 31.26 34.73 3.47 6.95 115.30
22 23 27.78 34.73 6.95 13.89 122.25
23 24 20.84 34.73 13.89 27.78 136.14
Fuente: SGI - EPYPSA
Nota.- Actualmente se tiene un tanque de 150 M3, por lo que para el proyecto se adopta un tanque nuevo de 100m3

DIAGRAMA DE MASAS RIPPLE San Buenaventura Página 2


Sistema de Agua Potable San Buenaventura
VARIACION DE VOLUMEN EN EL RESERVORIO

Demanda
Q máx dia Diferencia Diferencia Demanda
Horas Horaria Observaciones
(%) (%) Acumulada (%) Acumulada
(%)
0 1 100.00 45 55.00 55.00 19.10
1 2 100.00 45 55.00 110.00 38.20
2 3 100.00 45 55.00 165.00 57.30
3 4 100.00 45 55.00 220.00 76.40
4 5 100.00 45 55.00 275.00 95.51
5 6 100.00 60 40.00 315.00 109.40
6 7 100.00 90 10.00 325.00 112.87
7 8 100.00 135 -35.00 290.00 100.72
8 9 100.00 150 -50.00 240.00 83.35
9 10 100.00 150 -50.00 190.00 65.99
10 11 100.00 150 -50.00 140.00 48.62
11 12 100.00 140 -40.00 100.00 34.73
12 13 100.00 120 -20.00 80.00 27.78
13 14 100.00 140 -40.00 40.00 13.89
14 15 100.00 140 -40.00 0.00 0.00
15 16 100.00 130 -30.00 -30.00 -10.42
16 17 100.00 130 -30.00 -60.00 -20.84
17 18 100.00 120 -20.00 -80.00 -27.78
18 19 100.00 100 0.00 -80.00 -27.78
19 20 100.00 100 0.00 -80.00 -27.78
20 21 100.00 90 10.00 -70.00 -24.31
21 22 100.00 90 10.00 -60.00 -20.84
22 23 100.00 80 20.00 -40.00 -13.89
23 24 100.00 60 40.00 0.00 0.00
Fuente: SGI - EPYPSA

Sistema de Agua Potable San Buenaventura


DATOS PARA ELABORAR EL GRAFICO
LEY DE DEMANDAS HORARIAS PARA POBLACIONES MENORES
EN M3 PARA TODOS LOS CASOS

Demanda
Q máx dia Tangente Tangente Volumen
Horas Horaria Observaciones
Acumulado Inferior Superior Regulación
Acumulada
0 1 34.73 15.63 15.63 15.63 46.88 155.24
1 2 69.46 31.26 31.26 31.26 65.99 174.34
2 3 104.19 46.88 46.88 46.88 85.09 193.44
3 4 138.92 62.51 62.51 62.51 104.19 212.54
4 5 173.65 78.14 78.14 78.14 123.29 231.64
5 6 208.38 98.98 98.98 98.98 137.18 245.54
6 7 243.11 130.24 130.24 130.24 140.65 249.01
7 8 277.83 177.12 164.96 177.12 128.50 236.85
8 9 312.56 229.21 199.69 229.21 111.13 219.49
9 10 347.29 281.31 234.42 281.31 93.77 202.12
10 11 382.02 333.40 269.15 333.40 76.40 184.76
11 12 416.75 382.02 303.88 382.02 62.51 170.87
12 13 451.48 423.70 338.61 423.70 55.57 163.92
13 14 486.21 472.32 373.34 472.32 41.68 150.03
14 15 520.94 520.94 408.07 520.94 27.78 136.14
15 16 555.67 566.09 442.80 566.09 17.36 125.72
16 17 590.40 611.24 477.53 611.24 6.95 115.30
17 18 625.13 652.91 512.26 652.91 0.00 108.36
18 19 659.86 687.64 546.99 687.64 0.00 108.36
19 20 694.59 722.37 581.72 722.37 0.00 108.36
20 21 729.32 753.63 616.45 757.10 3.47 111.83
21 22 764.05 784.88 651.18 791.83 6.95 115.30
22 23 798.78 812.67 685.90 826.56 13.89 122.25
23 24 833.50 833.50 720.63 861.29 27.78 136.14
Fuente: SGI - EPYPSA

DIAGRAMA DE MASAS RIPPLE San Buenaventura Página 3


Sistema de Agua
DIAGRAMA DE RIPPLE
1000

900

800 Volumen Reservorio = 29.88% Qmáx diario

700

Volumen (m3)
600

500

400

300

200

100

0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

Tiempo (horas)

C. Max Dia Ripple Tg.I Tg.S Vol Reg Comp reservorio

DIAGRAMA DE MASAS RIPPLE San Buenaventura Página 4


CALCULO DE LAS DEMANDAS Y CAUDALES

Sistema de Agua Potable San Buenaventura

Población Por ciento Población Consumo Demanda Demanda Demanda Pérdida Demanda Demanda Demanda
Doméstica Conectada Conectada per capita Diaria Diaria Neta Anual Bruta Diaria Diaria
Año
Doméstica No Doméstica 0 Máxima Máxima
hab % hab L/h/d L/d L/d L/d (%) L/d L/d m3/d
(1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12)
2012 3,096 100 3,096 120.0 371,520 41,300 412,820 0 412,820 619,230 619
2017 3,358 100 3,358 120.0 403,000 41,300 444,300 0 444,300 666,451 666
2022 3,643 100 3,643 120.0 437,148 41,300 478,448 0 478,448 717,672 718
2027 3,952 100 3,952 120.0 474,190 41,300 515,490 0 515,490 773,234 773
2032 4,286 100 4,286 120.0 514,370 41,300 555,670 0 555,670 833,504 834
Fuente: SGI - EPYPSA

Demanda Demanda Demanda Demanda


Gasto
Contra Contra Reserva Reserva
Año requerido Año
Incendios Incendios
L/s L/d m3/d L/d m3/d
(1) (2) (3) (4) (1) (2) (3)
2012 0.463 40,034 40.03 2012 103,205 103
2017 0.482 41,665 41.66 2017 111,075 111
2022 0.502 43,360 43.36 2022 119,612 120
2027 0.522 45,124 45.12 2027 128,872 129
2032 0.543 46,957 46.96 2032 138,917 139
Tiempo de La demana de reserva será equivalente al Nº de
duración 30.00 minutos horas del consumo máximo diario
4 horas
Otra forma: Q = 15 (X ^1/2) X = Población conectada, (miles)
Q= 15 2.07 para el año 2032
Q= 31.06 L/s "muy alto"

Demanda Demanda Demanda Total Volumen del Reservorio


Diaria Contra Reserva Demanda Demanda Demanda
Año Regulación Total (r+r´)
Máxima Incendios Diaria Máxima Diaria Máxima Diaria Máxima
L/d L/d L/d L/d m3/d L/s m3 m3
(1) (2) (3) (4) (5) (6) (7) (8) (9)
2012 619,230 40,034 103,205 619,230 619 7.167 - -
2017 666,451 41,665 111,075 666,451 666 7.714 - -
2022 717,672 43,360 119,612 717,672 718 8.306 - -
2027 773,234 45,124 128,872 773,234 773 8.949 - -
2032 833,504 46,957 138,917 833,504 834 9.647 140.65 249.01
Fuente: SGI - EPYPSA
a) Qi 7.63 0.463 8.09 1.5 Q medio + Incendio
2012 b) Qmax h 14.33 Qmaxhorario
c) Qi 7.63 0.463 8.09 Qmax diario + Incendio
Caudales de diseño 14.33
Redes de distribución
a) Qi 10.19 0.463 10.65 1.5 Q medio + Incendio
2032 b) Qmax h 19.29 Qmaxhorario
c) Qi 10.19 0.463 10.65 Qmax diario + Incendio
19.29

T-1 Cálculo Caudales Agua V 5.1 San Buenaventura Página 5


CAUDALES MAXIMO DIARIO

Sistema de Agua Potable San Buenaventura

Caudal Caudal Caudal Caudal Caudal


Máximo Máximo Máximo Máximo Máximo
Año
Diario Diario Diario Diario Horario
L/s m3/hr L/d m3/d L/s
(1) (2) (3) (4) (5) (6)
2012 7.167 25.80 619,230 619.23 14.33
2017 7.714 27.77 666,451 666.45 15.43
2022 8.306 29.90 717,672 717.67 16.61
2027 8.949 32.22 773,234 773.23 17.90
2032 9.647 34.73 833,504 833.50 19.29
Fuente: SGI - EPYPSA

Volumen 125 15.00%


Volumen 249 29.88%

El subsistema 01, actualmente cuenta con un tanque de almacenamiento de 150


m3; sin embargo de acuerdo a los criterios y parámetros de diseño, se requiere
un volumen total de 250 m3; lo que equivale decir que para el mejoramiento del
sistema se dimensionará un tanque de almacenamiento de 100 m3.

T-1 Cálculo Caudales Agua V 5.1 San Buenaventura Página 6