Documentos de Académico
Documentos de Profesional
Documentos de Cultura
DATOS
CÁLCULO DEL Cp
AGUA DE ENFRIAMIENTO TOLUENO
𝐶_𝑃=𝑎+𝑑𝑇+𝑐𝑇^2+𝑑𝑇^3 𝐶_𝑃=𝑎+𝑑𝑇+𝑐𝑇^2+𝑑𝑇^3
INTERV. DE TEMP (l) 273-373 ºK INTERV. DE TEMP (l) 270-370
a b-10^2 c-10^5 d-10^9 a b-10^2 c-10^5
18.2964 47.212 -133.88 1314.2 1.8083 81.222 -151.27
INTERV. DE TEMP (g) 0-1500 ºC INTER. DE TEMP (g) 0-1200
a b-10^2 c-10^5 d-10^9 a b-10^2 c-10^5
33.46 0.688 0.7604 -3.593 94.18 38 -27.86
CÁLCULO DE LA DENSIDAD
TIPO DE FLUJO: CONTRACORRIENTE
T1 (º F) 93 T2 (º F)
t2 (º F) 80 t1 (º F)
∆ 𝑇_2 13 ∆ 𝑇_1
CALOR DE TUBO Y CORAZA
FRIAMIENTO
TUBOS
UNIDADES
----- MEDIA LOGARÍTMICA DE TEMP. (MLDT) 11.4344841
ft R 1.6
in S 0.27777778
----- RELACIÓN FRACCIONARIA (Ft) 0.945
DIFERENCIA REAL DE TEMP. (At) 10.8055874
------
in
------ PROMEDIO DE TEMPERATURAS
ft2 LADO DE LA CORAZA LADO DE LOS TUBO
ft2 𝑇 ̅ 77.5 ºF 𝑇 ̅
IENTE 𝑇 ̅ 298.427778 º K 𝑇 ̅
Ta 77.5 ºF ta
ºF
ºF
ºF
Btu/Lb.º F
Lb/h
Btu/h PARA LADO DE LA CORAZA
------
CentiPoise AREA DE FLUJO (as)
Btu/h.in2.ºF 𝑎_𝑠=(𝐷𝐼∗𝐶^𝑖∗𝐵)/
Lb/ft3 (144∗𝑃_𝑇 ) as
------
Lb/in2 VELOCIDAD MÁSICA (Gs).
𝐺_𝑆=𝑊/𝑎_𝑠
Gs
NO
𝑇^2+𝑑𝑇^3 DIÁMETRO EQUIVALENTE (De)
𝐷_𝑒=(4∗(𝑃_𝑇^2−𝜋 𝐷_0^2∕4))/(𝜋𝐷_0 )
ºK De
d-10^9
1630 NÚMERO DE REYNOLDS (Res)
ºC 𝑅_𝑒𝑠=(𝐷_𝑒∗𝐺_𝑆)/𝜇
d-10^9 Res
80.33
jH 31.5323988
NÚMERO DE PRANDTL
Número de Prandtl=((𝐶𝑝∗𝜇)/𝐾)^(1⁄3)
a Ta
Cp
Pr 3.5982685 K
VISCOSIDAD (µ)
A Ta
µ
85
COEFICIENTE DE PELÍCULA (ho)
ℎ𝑜=𝑗𝐻∗𝐾/𝐷_𝑒 ∗((𝐶𝑝∗𝜇)/𝐾)^(1⁄3)
75 ho
10
TEMPERATURA EN LA PARED
tw
∅_𝑠 1
∅_𝑡 1
CÁLCULO
UNIDADES
ºF
------
------
------
ºF
MPERATURAS
LADO DE LOS TUBOS
89 ºF
304.816667 º K
89 ºF
A 502.528
ÁSICA (Gt).
UNIDADES
2694.61078 Lb/h.ft2 CÁLCULOS
AD (µ) f 0.0026118821
89 UNIDADES
0.50410917 NÚMERO DE CRUCES (N+1)
Ds 1.2708333333
PELÍCULA (hi)
UNIDADES
20.3232547
D)
UNIDADES
PARA TUBOS
PARA AGUA
TºF µ
-20 3
-10 2.6 TEMPERATURA VS VISCOSIDA
0 2.3 3.5
10 2
20 1.8
30 1.6
40 1.4 3
50 1.2 f(x) = 4.376480219E-15 x⁶ − 6.095103174E-12 x⁵ + 3.5150065936E-09 x⁴
+ 2.2956741330017
60 1.1 R² = 0.999621411427163
70 1
80 0.9 2.5
90 0.85
100 0.7
110 0.65
120 0.59 2
VISCOSIDAD
130 0.52
140 0.49
150 0.41
1.5
160 0.39
170 0.35
180 0.32
190 0.3 1
200 0.27
210 0.24
220 0.23
230 0.22 0.5
240 0.2
250 0.17
260 0.15
270 0.14 0
-50 0 50 100 150 200
280 0.14
290 0.13 TEMPERATURA
300 0.13
310 0.12
320 0.1
330 0.1
340 0.1
350 0.1
360 0.1 X6 X5 X4
370 0.1 Y 4.37648E-15 -6.0951E-12 3.515007E-09
380 0.1
390 0.1
VISCOSIDAD
TºF
-20
77.5
EMPERATURA VS VISCOSIDAD DEL AGUA
TEMPERATURA
X3 X2 X1
-1.113806E-06 0.000221947 -0.02975047 2.295674133
TºF µ
-20 1.1
-10 1.09 TEMPERATURA VS VISCO
0 1 1.2
10 0.9
f(x) = − 1.613449566E-15 x⁶ + 1.670009197E-12 x⁵ − 5.54610877E-10 x⁴ + 2.702003
20 0.8 R² = 0.997748167575264
1
30 0.75
40 0.7 0.8
50 0.68
VISCOSIDAD
60 0.63 0.6
70 0.6
80 0.52 0.4
90 0.5
100 0.46 0.2
110 0.45
120 0.43 0
-50 0 50 100 150 20
130 0.39
TEMPER
140 0.36
150 0.34
160 0.32
170 0.31
180 0.29 X6 X5 X4 X3
190 0.28 Y -1.61345E-15 1.670009E-12 -5.546109E-10 2.702004E-08
200 0.26
210 0.25
220 0.23 VISCOSIDAD TOLUENO
230 0.22 TºF µ
240 0.21 -20 1.1
250 0.2 89 0.5041091714
260 0.19
270 0.17
280 0.16
290 0.16
300 0.15
310 0.14
320 0.14
330 0.13
340 0.13
350 0.13
360 0.12
370 0.12
380 0.12
390 0.1
ERATURA VS VISCOSIDAD DEL AGUA
X2 X
2.54778E-05 -0.00745057 0.972625555
EN LA PARED
VISCOSIDAD TOLUENO
TºF µ
86.155678708 0.513823116
DENSIDAD DEL AGUA
39.2 62.4278
60.5
41 62.4278
42.8 62.4272 60
200 250
DENSIDAD DEL TOLUENO
DENSIDAD
54
DENSIDAD 53.9
TºF r 53.8
68 54.3122099 53.7
89 53.19058996667 53.6
53.5
66 68 70 72 74 76 78
TEMPERATURA
X
Y -0.05341047 57.9441222
UENO
22222
76 78
Re vs jH
Res jH
10 1.9 f(x) = − 6.41642794539318E-10 x² + 0.001308038364922 x + 24.6416777718182
R² = 0.982520893427306
20 2.6
30 3 601
50 3.9
100 5.4
200 7 501
300 9
500 11
1000 17 401
2000 24
3000 28 jH
5000 39 301
10000 58
20000 80
30000 100 201
50000 130
100000 200
200000 280 101
300000 350
500000 480
1000000 700 1
0 200000 400000 600000 800000 1000
Número de Reynolds Re
JH
Res JH
10 1.9
5281.66485 31.5323988
JH X2 X
Res JH y -6.416428E-10 0.00130804 24.6416778
3485.13046 29.1925686
jH
38364922 x + 24.6416777718182
e Reynolds Re
VALOR DE LA CONDUCTIVIDAD TÉRMICA (K)
AGUA
TºF K TEMPERATURA VS CONDUCTIVIDAD
32 0.33 0.45
86 0.356 0.4
140 0.381 f(x) = 0.000471277399849 x + 0.315116402116402
0.35 R² = 0.999933123830873
176 0.398
CONDUCTIVIDAD K
0.3
0.25
0.2
0.15
K PARA AGUA UNIDADES
0.1
TºF K Btu/(h)(ft2)(ºF/ft)
32 0.33 Btu/(h)(ft2)(ºF/ft) 0.05
X
Y 0.00047128 0.3151164
TOLUENO
S CONDUCTIVIDAD TºF K
86 0.086
167 0.084
x + 0.315116402116402
X
Y -2.469136E-05
TEMPERATURA VS CONDUCTIVIDAD
0.0865
0.086
f(x) = − 2.46913580246913E-05 x + 0.088123456790124
R² = 1
0.0855
CONDUCTIVIDAD K
0.085
0.0845
0.084
0.0835
0.083
80 90 100 110 120 130 140 150 160 170 180
TEMPERATURA EM ºF
0.088123457
FACTOR DE FRICCIÓN LADO TUBO
LADO TUBO Re vs f
Re f
0.01
56 0.009
0.009
60 0.0085 0.008
80 0.0065 0.007
100 0.005 0.006
200 0.0025 0.005 f(x) = 0.037904251595695 x^-0.484160474752725
f
500 0.001 0.004 R² = 0.901021802527646
LADO CORAZA
Re f Re vs f
10 0.042 0.045
20 0.021
0.04
30 0.015
0.035
50 0.0098
0.03
100 0.006
200 0.0046 0.025
f
300 0.0042 0.02
500 0.0037 0.015 f(x) = 0.033556509561767 x^-0.298322263157796
1000 0.0032 R² = 0.867365371321627
0.01
2000 0.0028 0.005
3000 0.0026
0
5000 0.0024 0 200000 400000 600000
10000 0.002 Re
20000 0.0019
100000 0.0014
1000000 0.0009
f, coraza
Re f
10 0.042
5281.66485 0.00261188
Re vs f
Masa velocidad
300000 0.012
0.3
400000 0.022
500000 0.034 0.2
600000 0.048
700000 0.066 0.1
800000 0.084 0
1000000 0.13 0 200000 400000 600000 800000 100000
Pérdida de P
Masa vel V²/2g
85000 0.001 X5 X4 X3
2694.610778443 -0.04310486 Y 5.105851E-30 -1.317453E-23 1.225289E-17
elocidad vs V²/2g
X2 X
-4.860286E-12 8.537823E-07 -0.04537042