Documentos de Académico
Documentos de Profesional
Documentos de Cultura
Riego Por Goteo de Maiz
Riego Por Goteo de Maiz
D= (Qe/(0.75 * Ib))
DATO:
D = Diámetro del bulbo humedecido (m). Ib= 12.7 mm/h
qe = Caudal del emisor (L/h). qe = 2 L/h
Ib = Infiltración básica (mm/h).
D= 0.4 m
A = π(a) 2 /4 * m * n
Del 100% del area de plantas y entre surcos solo el 39% esta cubierta
Aljibury Kl = 0.53
Decroix Kl = 0.49
Hoare Kl = 0.70
Keller Kl = 0.48
Promedio KL = 0.55
Para riego localizado este valor se estila poner entre 1.15 y 1.20 (Pizarro 1996)
Kcl: 1.18
DATO:
Area: 4.45 Ha
Kd: 0.96
Nn = ETc - Pe DATO:
Asumiendo Pe=0
Nn = Necesidades netas diarias de riego (mm/dia)
Etc = Evapotranspiracion del cultivo (mm/dia)
Pe = Precipitacion efectiva
Ln = (LDzr * UR)/100
Ln = 11.4 mm
I R = Ln/Nn
IR = 2.6 dias
IR = 2 dias
DATO:
LR = CE i / 2CE e CEi = 0.5 ds/m
CEe = 2 ds/m
LR = Requerimientos de lavado f= 1
CEi = Conductividad electrica del agua de riego (ds/m)
CEe = Conductividad del extracto de saturacion del suelo (ds/m)
L B = Ln/(1-k)/ * Eap.
L B = Ln/(1-k)/ * Eap.
LB = 14.5 mm
PAR= 60.0 %
Phr = Qe/(dl*de)
No exisitira encharcamiento
S = a/r * 100
DATO:
S = Traslape expresado en tanto por ciento a= 0.05 m
a = Distancia recubierta por dos bulbos consecutivos r= 0.2 m
r = Radio de bulbo
S= 25 %
CR = IR - dp DATO:
dp 0 días
CR = Ciclo de riego (días).
Ir = Intervalo de riego ajustado (días).
dp = Días de paro (días).
Tr = Lb /Phr
Tr = Tiempo de riego (h)
Phr = Precipitación horaria del sistema (m
LB = Lamina bruta (mm)
Tr = 1.9 h
Tr = 2.0 h
#T = TO/Tr
DATO:
#T = Turnos diarios. TO 4 horas
TO= Tiempo de opercion.
Tr = Tiempo de riego
#T = 2.1 turno
#T = 2.0 turno
SUR = CR * #T
SUR = Subunidad de riego por turno
CR = Ciclo riego (días).
#T = Numero de turnos
SUR = 4 sur/ciclo
ST = AT / #T DATO:
AT = 4.45 ha
At = Superficie por cada subunidad de riego (ha/ sur).
At = Area total.
#T = Numero de turnos
DATO:
Qd = Caudal de diseño Caudal otorgado(l/s) 14.5 l/s
LB = Lamina bruta (mm)
At = Area total.
TO= Tiempo de opercion.
Qr = Frecuencia de riego.
Profundidad radicular
Doorenbos y Kassam 1970. estudio de riego y drenaje
FAO 1989
Keller 1978
Keller 1978
OK
J. Fuentes 1999
J. Fuentes 1999
INFORMACION BRINDADO POR E
eller 1978
eller 1978
Fuentes 1999
Fuentes 1999
NFORMACION BRINDADO POR EL
0.1
H= *H
x
0.1 DATO:
H= *H
x x= 0.85
k= 0.6
∆H= Variacion maxima de la presion H= 10.2 m.c.a
H= Presion del trabajo del emisor
x,k = Coeficientes caracteristicos del emosor
∆H = 1.32 m.c.a
En terrenos de poca pendiente se suele hacer: ΔHt = ΔHl es decir que la variacion
de presión admisible en la terciaria (ΔHt) y en cada lateral (ΔHl) son iguales.
H L H ( Z Z ) TIPO DE CONDICION
So = S
∆Hl = Perdida de carga admisible
∆H= Variacion maxima de la presion DATO:
Zz = Pendiente máxima del terreno (subida) Zz = 1 m
Ql = N°.Emisores * qe DATO:
qe = 2 h/l
No. De emisores por lateral
qe = Caudal del gotero
F = Coeficiente de Cristiansen
I° = Se y β 1.75
No. De emisores por lateral (n) = 22.64
Le = 0.11 m
PO /γ = (P/γ)+β*hL+α*Zl
P/γ =Presión media en la tuberia considerada, en [m.c.a.]
ZL = Desnivel de la tuberia considerada, en[m]
α y β = Coeficientes adimensionales
DATO:
β = (m+1)/(m+2) m= 1.75 m
α= 0.5
β= 0.73
P/γ = H = 10.2
Po/γ = 10.24
de diámetro interior 13.2 mm y PEBD 12.5 mm - 2.5 atm de diámetro interior 10.3 mm
Qt = N°.lateralres * Ql
F = Coeficiente de Cristiansen
I° = Se y β 1.75
No. De emisores por lateral (n) = 141
DIAMETRO TEORICO(Dt)
1/4.75
Dt= Km*Fr*L*C*Ql1.75 / Ht DATO:
Km = 1.2
Km = Coeficiente de perdida que varia de (1.1 a 1.4)
L = Longitud de la tuberia terciaria
C = Coeficiente de corrección por temperatura
Qt = Caudal al comienzo de la terciaria
F = Coeficiente de Cristiansen
Dt = 40.04 [mm]
PO /γ = (P/γ)+β*hL+α*Zl
P/γ =Presión media en la tuberia considerada, en [m.c.a.]
ZL = Desnivel de la tuberia considerada, en[m]
α y β = Coeficientes adimensionales
DATO:
β = (m+1)/(m+2) m= 1.75 m
α= 0.5
β= 0.73
P/γ = H = 10.24
Po/γ = 10.24
Boletin INIA diseño mantenimie
de equipos de riego localizado
de riego localizado
J. Fuentes 1999
1.258056E-05
T° = 0.464 f (20ºC) tabla 4.2
A diseño mantenimient
e riego localizado
zado
AREA N° 04
113.13 115.19 113.13 113.13 POTENCIA ABSORBID
112.82 112.82 112.82 112.82
112.43 112.43 112.43 112.43 ρ*g*Q*H m
112.04 112.04 112.04 112.04 p ABS. =
Ef.bomba
111.67 111.67 111.67 111.67
111.28 111.28 111.28 111.28 Pabs. =Potencia absorbida por la bomba
110.9 110.9 110.9 110.9
110.53 110.53 110.53 110.53 Pabs. =
110.15 110.15 110.15 110.15
109.77 109.77 109.77 109.77
109.39 109.39 109.39 109.39
109 109 109 109
108.63 108.63 108.63 108.63
108.19 108.19 108.19 108.19
107.71 107.71 107.71 107.71
107.24 107.24 107.24 107.24
106.77 106.77 106.77 106.77
106.29 106.29 106.29 106.29
105.82 105.82 105.82 105.82
105.34 105.34 105.34 105.34
104.87 104.87 104.87 104.87
104.4 104.4 104.4 104.4
103.92 103.92 103.92 103.92
103.45 103.45 103.45 103.45
102.98 102.98 102.98 102.98
102.5 102.5 102.5 102.5
102.02 102.02 102.02 102.02
101.54 101.54 101.54 101.54
101.06 101.06 101.06 101.06
100.57 100.57 100.57 100.57
100.09 100.09 100.09 100.09
99.6 99.6 99.6 99.6
99.12 99.12 99.12 99.12
98.64 98.64 98.64 98.64
98.15 98.15 98.15 98.15
98.67 98.67 98.67 98.67
97.18 97.18 97.18 97.18
96.7 96.7 96.7 96.7
96.22 96.22 96.22 96.22
95.73 95.73 95.73 95.73
95.25 95.25 95.25 95.25
94.76 94.76 94.76 94.76
94.28 94.28 94.28 94.28
93.8 93.8 93.8 93.8
93.31 93.31 93.31 93.31
92.76 92.76 92.76 92.76
92.16 92.16 92.16 92.16
91.56 91.56 91.56 91.56
90.95 90.95 90.95 90.95
90.35 90.35 90.35 90.35
89.74 89.74 89.74 89.74
89.14 89.14 89.14 89.14
88.54 88.54 88.54 88.54
87.93 87.93 87.93 87.93
87.33 87.33 87.33 87.33
86.72 86.72 86.72 86.72
86.12 86.12 86.12 86.12
85.52 85.52 85.52 85.52
84.91 84.91 84.91 84.91
84.31 84.31 84.31 84.31
83.71 83.71 83.71 83.71
83.1 83.1 83.1 83.1
82.5 82.5 82.5 82.5
81.89 81.89 81.89 81.89
81.29 81.29 81.29 81.29
80.69 80.69 80.69 80.69
80.08 80.08 80.08 80.08
79.48 79.48 79.48 79.48
78.87 78.87 78.87 78.87
78.27 78.27 78.27 78.27
77.66 77.66 77.66 77.66
77.06 77.06 77.06 77.06
76.46 76.46 76.46 76.46
75.85 75.85 75.85 75.85
75.24 75.24 75.24 75.24
74.58 74.58 74.58 74.58
73.93 73.93 73.93 73.93
73.27 73.27 73.27 73.27
72.61 72.61 72.61 72.61
71.97 71.97 71.97 71.97
71.31 71.31 71.31 71.31
70.66 70.66 70.66 70.66
70 70 70 70
69.35 69.35 69.35 69.35
68.7 68.7 68.7 68.7
68.04 68.04 68.04 68.04
67.39 67.39 67.39 67.39
66.73 66.73 66.73 66.73
66.08 66.08 66.08 66.08
65.42 65.42 65.42 65.42
64.77 64.77 64.77 64.77
64.12 64.12 64.12 64.12
63.46 63.46 63.46 63.46
62.81 62.81 62.81 62.81
62.15 62.15 62.15 62.15
61.5 61.5 61.5 61.5
60.84 60.84 60.84 60.84
60.19 60.19 60.19 60.19
59.54 59.54 59.54 59.54
58.88 58.88 58.88 58.88
58.23 58.23 58.23 58.23
57.58 57.58 57.58 57.58
56.92 56.92 56.92 56.92
56.27 56.27 56.27 56.27
55.61 55.61 55.61 55.61
54.96 54.96 54.96 54.96
54.31 54.31 54.31 54.31
53.65 53.65 53.65 53.65
52.99 52.99 52.99 52.99
52.34 52.34 52.34 52.34
51.69 51.69 51.69 51.69
51.04 51.04 51.04 51.04
50.38 50.38 50.38 50.38
49.73 49.73 49.73 49.73
49.07 49.07 49.07 49.07
48.42 48.42 48.42 48.42
47.77 47.77 47.77 47.77
47.11 47.11 47.11 47.11
46.45 46.45 46.45 46.45
45.8 45.8 45.8 45.8
45.15 45.15 45.15 45.15
44.49 44.49 44.49 44.49
43.84 43.84 43.84 43.84
43.19 43.19 43.19 43.19
42.53 42.53 42.53 42.53
41.88 41.88 41.88 41.88
41.22 41.22 41.22 41.22
40.57 40.57 40.57 40.57
39.92 39.92 39.92 39.92
39.26 39.26 39.26 39.26
38.61 38.61 38.61 38.61
37.81 37.81 37.81 37.81
36.97 36.97 36.97 36.97
36.12 36.12 36.12 36.12
35.27 35.27 35.27 35.27
34.42 34.42 34.42 34.42
33.58 33.58 33.58 33.58
32.73 32.73 32.73 32.73
31.89 31.89 31.89 31.89
31.04 31.04 31.04 31.04
30.2 30.2 30.2 30.2
29.35 29.35 29.35 29.35
28.51 28.51 28.51 28.51
27.66 27.66 27.66 27.66
26.81 26.81 26.81 26.81
25.97 25.97 25.97 25.97
25.09 25.09 25.09 25.09
24.15 24.15 24.15 24.15
23.22 23.22 23.22 23.22
22.29 22.29 22.29 22.29
21.36 21.36 21.36 21.36
20.42 20.42 20.42 20.42
19.49 19.49 19.49 19.49
18.56 18.56 18.56 18.56
17.63 17.63 17.63 17.63
16.69 16.69 16.69 16.69
15.76 15.76 15.76 15.76
14.83 14.83 14.83 14.83
13.9 13.9 13.9 13.9
12.96 12.96 12.96 12.96
12.03 12.03 12.03 12.03
11.09 11.09 11.09 11.09
10.17 10.17 10.17 10.17
9.23 9.23 9.23 9.23
8.3 8.3 8.3 8.3
7.45 7.45 7.45 7.45
6.61 6.61 6.61 6.61
5.77 5.77 5.77 5.77
4.94 4.94 4.94 4.94
4.15 4.15 4.15 4.15
3.39 3.39 3.39 3.39
2.62 2.62 2.62 2.62
1.86 1.86 1.86 1.86
1.09 1.09 1.09 1.09
PROM= 64.31
POTENCIA ABSORBIDA POR LA BOMBA
ρ*g*Q*H m
p ABS. =
Ef.bomba
cia absorbida por la bomba
0.0002