Está en la página 1de 10

Factor De Seguridad 1.

4
Cálculo Ancho del Pilar

Resistencia Pilar
Wp Hp W/H Cpav RCS k Sp
(m) (m) (Mpa) (Mpa)
5 9 0.56 0.25 100.00 1.34 60.58
6 9 0.67 0.30 100.00 1.55 65.29
7 9 0.78 0.33 100.00 1.70 68.91
8 9 0.89 0.35 100.00 1.83 71.74
9 9 1.00 0.37 100.00 1.93 73.99
10 9 1.11 0.38 100.00 2.01 75.81
11 9 1.22 0.39 100.00 2.07 77.29
12 9 1.33 0.40 100.00 2.12 78.52
13 9 1.44 0.41 100.00 2.17 79.54
14 9 1.56 0.42 100.00 2.21 80.41
15 9 1.67 0.42 100.00 2.24 81.14

C1 0.68 K 0.44
C2 0.52

Sigma P 7.5 área Pilar 2*2 4m

1-Cpav 1+Cpav ACos


0.75 1.25 0.92973943
0.70 1.30 0.99661191
0.67 1.33 1.04010427
0.65 1.35 1.07017547
0.63 1.37 1.09193767
0.62 1.38 1.10825368
0.61 1.39 1.12083664
0.60 1.40 1.13076696
0.59 1.41 1.13875563
0.58 1.42 1.14528732
0.58 1.42 1.15070243
Sigma P Fs Recuperación
(Mpa) (%)
Factor De Seguridad 1.4
Cálculo Ancho del Pilar

Wp Hp Wp/Hp Cp (Cont. Conf.) 1-Cp 1+Cp


5 9 0.56 0.002 0.998 1.002
6 9 0.67 0.009 0.991 1.009
7 9 0.78 0.022 0.978 1.022
8 9 0.89 0.041 0.959 1.041
9 9 1.00 0.063 0.937 1.063
10 9 1.11 0.088 0.912 1.088
11 9 1.22 0.114 0.886 1.114
12 9 1.33 0.138 0.862 1.138

C1 0.68 K 0.44
C2 0.52

RCS 100 Mpa

σv 8.7 Mpa
Wo 5.4 m
Lp 7.6 m
Lo 7.6 m
ROOM AND PILLAR Teoria LUNDER-PAKALNIS

Acos (1-Cp)/(1+Cp) k Sp σp F.S σp1 F.S₁


0.09 0.09 31.98 18.10 1.7670116 36.19 0.88
0.19 0.19 34.23 16.53 2.07073369 33.06 1.04
0.29 0.30 36.84 15.41 2.39025032 30.82 1.20
0.40 0.42 39.55 14.57 2.71382699 29.15 1.36
0.49 0.54 42.23 13.92 3.0338992 27.84 1.52
0.58 0.65 44.83 13.40 3.34614867 26.80 1.67
0.65 0.76 47.32 12.97 3.64817185 25.94 1.82
0.71 0.86 49.69 12.62 3.93864217 25.23 1.97
Revisión
Razón Extracción σp
75.96 36.19
73.68 33.06
71.77 30.82
70.15 29.15
68.75 27.84
67.53 26.80
66.46 25.94
65.52 25.23
Factor De Seguridad 1.4

Wp Hp
5 9
6 9
7 9
8 9
10 9
11 9
12 9
Factor De Seguridad 1.4
Cálculo Ancho del Pilar Cuadrados

Wo (Ancho pilar) altura pilar (Hp) Perimetro Pilar (Pp) Ap (Área Pilar)
4 5 16 16
5 6 20 25
6 7 24 36
7 8 28 49
8 9 32 64
9 10 36 81
10 11 40 100
11 12 44 121
12 13 48 144

lados (cuadrado) 4

Sp = So * Hͣ * W
ROOM AND PILLAR Teoria HARDY-AGAPITO

Wp (Ancho efectivo)
4
5
6
7
8
9
10
11
12
Calculo Crown Pillar

Densidad (Ƴ) S (Ancho Cas.) L (Largo Cas.) ángulo (Ɵ) Potencia (T) Cn
Ton/m³ m m ° m (1-0.4 cos Ɵ)
2.5 15 45 60 16 21.33
2.5 16 50 65 17 22.44
2.5 17 55 70 18 23.56
2.5 18 60 75 20 26.00
2.6 15 45 60 16 21.33
2.6 16 50 65 17 22.44
2.6 17 55 70 18 23.56
2.6 18 60 75 20 26.00
2.7 15 45 60 16 21.33
2.7 16 50 65 17 22.44
2.7 17 55 70 18 23.56
2.7 18 60 75 20 26.00

L (Luz) 7.6
t Pilar intermedio
E 32
Cn` Cn*Cn` Cs (crown Pillar) t (Crown Pilar) ƞ
(1-0.4 cos Ɵ) m m m
1.38 29.46 4.37 14.25 0.04011111
1.22 27.49 4.83 14.25 0.04011111
0.75 17.59 6.41 14.25 0.04011111
0.63 16.41 7.02 14.25 0.04011111
1.38 29.46 4.46 14.82 0.03856838
1.22 27.49 4.92 14.82 0.03856838
0.75 17.59 6.54 14.82 0.03856838
0.63 16.41 7.16 14.82 0.03856838
1.38 29.46 4.54 15.39 0.03713992
1.22 27.49 5.01 15.39 0.03713992
0.75 17.59 6.66 15.39 0.03713992
0.63 16.41 7.30 15.39 0.03713992