Está en la página 1de 35

UNIVERSIDAD MAYOR DE SAN SIMON

FACULTAD DE CIENCIAS Y TECNOLOGIA


LICENCIATURA EN INGENIERIA CIVIL

ESTUDIANTE: Univ. Paco Garcia Bady Peregrini


DOCENTE: Ing. M.Sc. Martin Duchen Ayala
ASIGNATURA: Fundaciones I
GESTION: II – 2017
AUXILIAR: Univ. Beltran Luizaga Cristian

COCHABAMBA – BOLIVIA
Índice
PARTE I: INTRODUCCION, ASPECTOS ARQUITECTONICOS Y ANALISIS DE CARGAS ............ 1
1.- INTRODUCCION ...................................................................................................................... 1
2.- ASPECTOS GENERALES DEL PROYECTO ARQUITECTONICO ....................................................... 2
3.- ANALISIS DE CARGAS Y DATOS DEL ANALISIS DEL SUELO.......................................................... 4
PARTE II: ANALISIS ESTRUCTURAL ............................................................................................... 9
4.- DATOS DE ENTRADA................................................................................................................... 9
5.- DATOS DE SALIDA..................................................................................................................... 12
PARTE III: DISEÑO Y DMENSIONADO DE ELEMENTOS ESTRUCTURALES ........................................ 17

6.- DISEÑO Y DIMENSIONADO DE COLUMNAS DE HORMIGON ARMADO ................................... 18


PARTE IV: ANALISIS, DISEÑO Y DIMENSONADO DE FUNDACIONES ............................................... 32

7.- DISEÑO Y DIMENSIONADO DE LAS ZAPATAS AISLADAS .......................................................... 33


7.1.- DISPOSICION DE ARMADURAS DE LAS ZAPATAS .................................................................. 72
PARTE V: PROCESO CONSTRUCTIVO, DOSIFICACION, COMPUTOS METRICOS, MATERIALES,
CONCLUSION Y ANEXOS ................................................................................................................... 86

8.- PROCESO CONSTRUCTIVO DE LAS FUDACIONES (ZAPATAS AISLADAS)................................... 86


9.- DOSIFICACION DE HORMIGON PARA FUNDACIONES ZAPATAS AISLADAS.............................. 88
10.- COMPUTOS METRICOS DEL HORMIGON DE LAS FUNDACIONES .......................................... 92
11.- PLANILLA DE MATERIALES PARA FUNDACIONES ................................................................... 93
12.- CONCLUSIONES Y RECOMENDACIONES................................................................................. 94
13.- ANEXOS .................................................................................................................................. 95

PARTE VI: PLANO ESTRUCTURAL Y DETALLE DE ZAPATAS AISLADAS, ESCALAS, PLANILLA DE


ACEROS Y NOTAS GENERALES.......................................................................................................... 96

14.- PLANO ARQUITECTONICO ............................................................................................SOBRE 1


15.- PLANO ESTRUCTURAL DE ZAPATAS AISLADAS (VISTA EN PLANTA) ..............................SOBRE 2

16.- PLANO A DETALLE DE LAS ZAPATAS AISLADAS ............................................................SOBRE 3


Diseño de zapatas aisladas Fundaciones I

PARTE I: INTRODUCCION, ASPECTOS ARQUITECTONICOS Y ANALISIS


DE CARGAS

1. INTRODUCCION

En el presente proyecto se pretende realizar el diseño de elementos estructurales


denominados zapatas aisladas céntricas cuya función es la de transmitir las cargas de un
edificio al suelo.

Se define como zapatas aisladas céntricas a aquellas que transmiten las cargas de una
sola columna al suelo, pueden ser de diversas formas geométricas de acuerdo a las
necesidades, su uso es indicado para casos en los que las cargas son relativamente bajas y/o
el suelo tenga buena resistencia. Su funcionamiento no es complejo y su cálculo no ofrece
mucha dificultad, estas serán analizadas como fundaciones rígidas.

El diseño de estas zapatas se hará de la manera más eficiente entendiendo por esto
que cada zapata contara con la menor cantidad de acero de refuerzo y hormigón, de manera
que resista satisfactoriamente todas las cargas y solicitaciones de la estructura con un factor
de seguridad conservador, dado que estos elementos son los más importantes en cualquier
obra civil.

Para tal efecto se realizara la simulación estructural en el programa SAP-2000, para


obtener las cargas de servicio y diseñar con estas las columnas de la planta baja y las zapatas.

Los valores y parámetros asumidos serán mostrados debidamente en las hojas de


cálculo al momento de realizar los diseños.

Finalmente, se realizará el plano estructural en tamaño DIN A0 con el contenido


mínimo especificado y con todas las vistas posibles para un buen entendimiento del mismo.

1
Diseño de zapatas aisladas Fundaciones I

2. ASPECTOS GENERALES DEL PROYECTO ARQUITECTONICO

2.1. UBICACIÓN DEL PROYECTO ARQUITECTONICO

 ZONA: Sud Este


 DISTRITO: N° 10
 SUB DISTRITO: N° 12
 MANZANA: 0.20
 DIRECCION: Calle Calama N° e-0564

2.2. FUNCION A DESARROLLARSE EN LA EDIFICACION

 Planta sótano: depósitos y sala de máquinas.


 Planta baja: oficinas y locales comerciales.
 Primer piso: oficinas
 Segundo piso: oficinas.

2
Diseño de zapatas aisladas Fundaciones I

2.3. PROPIETARIOS

 Defensa del niño internacional.

2.4. NUMERO DE NIVELES DEL PROYECTO


El proyecto consta de cuatro niveles:
 Planta sótano.
 Planta baja
 Primer piso (oficinas).
 Segundo piso (oficinas).

2.5. IMAGEN DEL PISO TIPO – VISTA SAP2000

Vista en planta piso tipo plano arquitectonico. Imagen en planta piso tipo SAP2000.

3
Diseño de zapatas aisladas Fundaciones I

3. ANALISIS DE CARGAS Y DATOS DEL ANALISIS DEL SUELO

3.1. PREDIMENSIONAMIENTO DE ELEMENTOS ESTRUCTURALES

3.1.1. PREDIMENSIONADO DE LOSAS


Para calcular el espesor mínimo de la losa se utilizara la ecuación (9 – 13) del
Código ACI 318 – ’05 (ver Anexos).

Para la losa más crítica tenemos:

Luz libre larga= 640 cm

Luz libre corta= 320 cm

De la ecuación obtenemos:

hs = 12.15 cm

Entonces el espesor de la losa será:

hs = 14 cm

3.1.2. PREDIMENSIONADO DE VIGAS


En el pre dimensionamiento se tomara en cuenta aquella viga con mayor luz
libre, es decir la más larga, y posteriormente se podrán utilizar las formulas
propuestas por el Código ACI 318 – ’05, usando la Tabla 9.5 (a) para el cálculo de
espesores mínimos, ver anexos.

Longitud viga (l)= 6.4 m

ℎ =
.

h min = 34.59 cm

h = 40 cm

4
Diseño de zapatas aisladas Fundaciones I

Asumimos una relación de ≥ por lo tanto tenemos una viga de:

h= 40 cm

b= 20 cm

3.1.3. PREDIMENSIONADO DE COLUMNAS

Para el primer y segundo nivel usamos: a=35 cm; b= 35 cm


Para el tercer y cuarto nivel usamos: a= 30cm; b=30cm

3.1.4. PREDIMENSIONADO DE ESCALERAS


Para escaleras utilizamos un espesor de: 12 cm
Huella= 30 cm
Contrahuella= 17 cm

3.2. DETERMINACION DE CARGAS MUERTAS


El programa estructural SAP2000 v.14 que es el que usamos para el análisis estructural
considera como carga muerta a todo el peso de la estructura (vigas, losas columnas, escaleras,
etc.) así que acá solo consideraremos la sobrecarga.

5
Diseño de zapatas aisladas Fundaciones I

3.2.1. DETERMINACION DE CARGAS MUERTAS SOBRE LOSAS

 Peso de piso =75 kg/m2


 Peso de contrapiso =34 kg/m2
 Peso de yeso =36 kg/m2
 Muro de partición =100 kg/m2
 Luminarias =15 kg/m2
Carga muerta total sobre la losa= 260 kg/m2
3.2.2. DETERMINACION DE CARGAS MUERTAS SOBRE ESCALERAS

 Peso del piso = 60 kg/m2


 Peso de contrapiso = 60 kg/m2
 Peso del yeso = 30 kg/m2
 Peso de peldaños = 210 kg/m2
 Luminarias = 10 kg/m2
Carga muerta total sobre escaleras= 370 kg/m2
3.3. DETERMINACION DE CARGAS VIVAS
Para determinar el peso de la carga viva, nos basaremos en normas y reglamentos según sea
la funcionalidad que se dé a la estructura, tomando en cuenta siempre la Norma ASCE 7-05,
Para el proyecto se adoptará valores de carga viva o sobrecarga correspondientes a los
valores de la siguiente tabla:

ELEMENTO ESTRUCTURAL SOBRECARGA


Sobrecarga de uso de viviendas
Habitaciones de viviendas económicas 150 kg/m2
Habitaciones de viviendas en otros casos 250 kg/m2
Escaleras y accesos públicos 500 kg/m2
Sobrecargas de oficinas y colegios
Locales privados 200 kg/m2
Oficinas públicas y tiendas 250 kg/m2
Galerías comerciales, escaleras y accesos 400 kg/m2

En este caso la estructura analizada será usada para oficinas por lo tanto las cargas
vivas actuantes serán:
 = 250 kg/m2 (losas)
 = 500 kg/m2 (escaleras )

6
Diseño de zapatas aisladas Fundaciones I

3.4. COMBINACION DE CARGAS


Para este proyecto se toman las combinaciones críticas para diseño de columnas y
fundaciones. Entonces para el diseño se usó tres combinaciones de cargas según la norma
American Concrete Institute (ACI 318 - 05).

Para el diseño en planta de las zapatas no se requieren cargas mayoradas P, por lo


que no se aplicó ningún factor de mayoración a las cargas vivas y muertas, la combinación
utilizada para este caso es:

 1.4 D
Esta combinación se designó en el SAP2000 como Carga de servicio.

Para tanques de almacenamiento de agua o cubiertas que acaben en losas se usara


la siguiente:

 D+L
Para el diseño de las zapatas se utilizó la combinación según norma ACI para obtener
la carga puntual última Pu, esta combinación es:

 1.2 D + 1.6 L
Dónde:

 D= cargas muertas
 L= cargas vivas

Por lo tanto las combinaciones usadas para el análisis estructural en el


programa SAP2000 son:

 Carga muerta: P= 1.4D


 Carga de servicio: P= D + L
 Carga mayorada: Pu= 1.2D + 1.6L

7
Diseño de zapatas aisladas Fundaciones I

3.5. NUMERO DE PISOS O LOSAS CARGADAS

3.6. DATOS DEL ANALISIS DEL SUELO


3.6.1. NIVEL DE FUNDACION

La estructura posee semisótano por lo tanto para el diseño de las fundaciones


usaremos un valor estándar:

 Cota de fundación (Df )= 1.2 m


3.6.2. RESISTENCIA ADMISIBLE DEL SUELO

Para el presente proyecto asumiremos que la resistencia admisible de suelo tiene un


valor de:

 = 1.04 / 2

8
Diseño de zapatas aisladas Fundaciones I

PARTE II: ANALISIS ESTRUCTURAL

El análisis estructural será realizado con software SAP2000 v.14, en esta parte se presentara como
como fue cargada la estructura, como se introdujeron los datos mencionados en la primera parte, además de
los resultados obtenidos por el software mencionado.

4. DATOS DE ENTRADA

TABLE: Program Control


ProgramName Version CurrUnits SteelCode ConcCode AlumCode ColdCode
Text Text Text Text Text Text Text
SAP2000 14.0.0 Kgf, m, C AISC-LRFD93 ACI 318-05/IBC2003 AA-ASD 2000 AISI-ASD96

4.1. ESPESORES DE LOSA

TABLE: Area Section Properties


Section Material AreaType Thickness BendThick Notes
Text Text Text m m Text
Losa Hormigon210 Shell 0.14 0.14 Added 02/09/2017 08:10:40 p.m.
Losa
Escalera Hormigon210 Shell 0.12 0.12 Added 02/09/2017 08:12:03 p.m.

9
Diseño de zapatas aisladas Fundaciones I

4.2.SECCION TRANSVERSAL DE VIGAS

TABLE: Frame Section Properties 03 - Concrete Beam


SectionName RebarMatL RebarMatC TopCover BotCover
Text Text Text m m
Viga40x20 A615Gr60 A615Gr60 0.025 0.025

4.3.SECCION TRANSVERSAL DE COLUMNAS

TABLE: Frame Section Properties 02 - Concrete Column


SectionName RebarMatL RebarMatC ReinfConfig Cover NumCBars2 NumCBars3
Text Text Text Text m Unitless Unitless
Columna30x30 A615Gr60 A615Gr60 Rectangular 0.025 3 3
Columna35x35 A615Gr60 A615Gr60 Rectangular 0.025 3 3
10
Diseño de zapatas aisladas Fundaciones I

4.4.PROPIEDADES GENERALES DEL HORMIGON Y DEL ACERO

TABLE: Material Properties 01 - General


Material Type SymType
Text Text Text
A615Gr60 Rebar Uniaxial
Hormigon210 Concrete Isotropic

TABLE: Material Properties 02 - Basic Mechanical Properties


Material UnitWeight UnitMass E1 G12 U12 A1
Kgf-
Text Kgf/m3 s2/m4 Kgf/m2 Kgf/m2 Unitless 1/C
A615Gr60 7849 800.38 20390000000 0.0000117
Hormigon210 2400 244.73 2188197889 875279155 0.25 0.0000117

TABLE: Material Properties 03b - Concrete Data


Material Fc
Text Kgf/m2
Hormigon210 2100000

11
Diseño de zapatas aisladas Fundaciones I

4.5.COMBINACIONES DE CARGAS

TABLE: Combination Definitions


ComboName ComboType AutoDesign CaseName ScaleFactor
Text Text Yes/No Text Unitless
1.4D Linear Add No DEAD 1.4
D+L Linear Add No DEAD 1
D+L LIVE 1
1.2D+1.6L Linear Add No DEAD 1.2
1.2D+1.6L LIVE 1.6
5. DATOS DE SALIDA
5.1.PLANILLA DE ESFUERZOS A NIVEL DE LA FUNDACION CON TRES COMBINACIONES

Frame Station OutputCase CaseType P M2 M3


Text m Text Text Kgf Kgf-m Kgf-m
Col A1 0 1.4D Combination -39429.33 -1793.72 1320.72
Col A1 0 D+L Combination -37047.9 -1664.16 1324.08
Col A1 0 1.2D+1.6L Combination -48011.11 -2150.16 1741.18
Col A3 0 1.4D Combination -54645.61 3048.36 2098.77
Col A3 0 D+L Combination -55148.88 3444.75 2402.18
Col A3 0 1.2D+1.6L Combination -72625.17 4640.64 3243.83
Col A4 0 1.4D Combination -38366.17 1400.48 2891.85
Col A4 0 D+L Combination -38031.6 1932.58 3270.01
Col A4 0 1.2D+1.6L Combination -49888.8 2692 4405.77
Col A5 0 1.4D Combination -20264.41 736.45 974.92
Col A5 0 D+L Combination -18476.42 810.07 911.2
Col A5 0 1.2D+1.6L Combination -23772.45 1085.7 1179.37
Col B1 0 1.4D Combination -61713.33 -1049.68 726.45
Col B1 0 D+L Combination -58966.99 -985.87 765.2
Col B1 0 1.2D+1.6L Combination -76714.81 -1277.49 1016.77
Col B2 0 1.4D Combination -75383.83 352.09 376.24
Col B2 0 D+L Combination -73999.7 425.89 376.68
Col B2 0 1.2D+1.6L Combination -96861.28 580.84 495.2
Col B3 0 1.4D Combination -98596.36 -375.73 959.11
Col B3 0 D+L Combination -97257.89 -311.98 805.34
Col B3 0 1.2D+1.6L Combination -127442.24 -391.82 1014.5
Col B4 0 1.4D Combination -93230.12 1089.87 759.97
Col B4 0 D+L Combination -91002.02 1179.99 605.33
Col B4 0 1.2D+1.6L Combination -118966.05 1576.59 751.39
Col B5 0 1.4D Combination -42173.22 1200.17 404.91
Col B5 0 D+L Combination -39355.19 1258.31 338.82
Col B5 0 1.2D+1.6L Combination -50918.81 1670.39 426.43

12
Diseño de zapatas aisladas Fundaciones I

Col C1 0 1.4D Combination -46274.98 -2150.94 -1953.53


Col C1 0 D+L Combination -43700.46 -2076.82 -1864.16
Col C1 0 1.2D+1.6L Combination -56699.32 -2708.36 -2424.51
Col C3 0 1.4D Combination -70628.9 822.55 -4161.99
Col C3 0 D+L Combination -67565.11 841.61 -4112.46
Col C3 0 1.2D+1.6L Combination -87924.48 1111.56 -5390.8
Col C4 0 1.4D Combination -51942.17 802.56 -3476.9
Col C4 0 D+L Combination -49190.3 816.14 -3450.76
Col C4 0 1.2D+1.6L Combination -63863.85 1076.52 -4527.81
Col C5 0 1.4D Combination -22052.16 592.11 -1767.69
Col C5 0 D+L Combination -19957 605.36 -1745.39
Col C5 0 1.2D+1.6L Combination -25630.58 799.39 -2287.57
5.2.PLANILA DE ESFUERZOS AXIALES A NIVEL DE FUNDACION

Frame Station OutputCase CaseType P M2 M3


Text m Text Text Kgf Kgf-m Kgf-m
Col A1 0 D+L Combination -37047.9 -1664.16 1324.08
Col A1 0 1.2D+1.6L Combination -48011.11 -2150.16 1741.18
Col A3 0 D+L Combination -55148.88 3444.75 2402.18
Col A3 0 1.2D+1.6L Combination -72625.17 4640.64 3243.83
Col A4 0 D+L Combination -38031.6 1932.58 3270.01
Col A4 0 1.2D+1.6L Combination -49888.8 2692 4405.77
Col A5 0 D+L Combination -18476.42 810.07 911.2
Col A5 0 1.2D+1.6L Combination -23772.45 1085.7 1179.37
Col B1 0 D+L Combination -58966.99 -985.87 765.2
Col B1 0 1.2D+1.6L Combination -76714.81 -1277.49 1016.77
Col B2 0 D+L Combination -73999.7 425.89 376.68
Col B2 0 1.2D+1.6L Combination -96861.28 580.84 495.2
Col B3 0 D+L Combination -97257.89 -311.98 805.34
Col B3 0 1.2D+1.6L Combination -127442.24 -391.82 1014.5
Col B4 0 D+L Combination -91002.02 1179.99 605.33
Col B4 0 1.2D+1.6L Combination -118966.05 1576.59 751.39
Col B5 0 D+L Combination -39355.19 1258.31 338.82
Col B5 0 1.2D+1.6L Combination -50918.81 1670.39 426.43
Col C1 0 D+L Combination -43700.46 -2076.82 -1864.16
Col C1 0 1.2D+1.6L Combination -56699.32 -2708.36 -2424.51
Col C3 0 D+L Combination -67565.11 841.61 -4112.46
Col C3 0 1.2D+1.6L Combination -87924.48 1111.56 -5390.8
Col C4 0 D+L Combination -49190.3 816.14 -3450.76
Col C4 0 1.2D+1.6L Combination -63863.85 1076.52 -4527.81
Col C5 0 D+L Combination -19957 605.36 -1745.39
Col C5 0 1.2D+1.6L Combination -25630.58 799.39 -2287.57

13
Diseño de zapatas aisladas Fundaciones I

5.3.VISTAS DE LA ESTRUCTURA
5.3.1. Columnas codificadas

14
Diseño de zapatas aisladas Fundaciones I

5.3.2. Estructura en conjunto

15
Diseño de zapatas aisladas Fundaciones I

5.3.3. Estructura deformada

16
Diseño de zapatas aisladas Fundaciones I

PARTE III: DISEÑO Y DIMENSIONADO DE ELEMENTOS


ESTRUCTURALES

6. DISEÑO Y DIMENSIONADO DE COLUMNAS DE HORMIGON ARMADO


6.1.PLANILLAS RESUMEN DE ESFUERZOS AXIALES DE LAS COLUMNAS A NIVEL DE FUNDACION

Frame Station OutputCase CaseType P M2 M3


Text m Text Text Kgf Kgf-m Kgf-m
Col A1 0 1.2D+1.6L Combination -48011.11 -2150.16 1741.18
Col A3 0 1.2D+1.6L Combination -72625.17 4640.64 3243.83
Col A4 0 1.2D+1.6L Combination -49888.8 2692 4405.77
Col A5 0 1.2D+1.6L Combination -23772.45 1085.7 1179.37
Col B1 0 1.2D+1.6L Combination -76714.81 -1277.49 1016.77
Col B2 0 1.2D+1.6L Combination -96861.28 580.84 495.2
Col B3 0 1.2D+1.6L Combination -127442.24 -391.82 1014.5
Col B4 0 1.2D+1.6L Combination -118966.05 1576.59 751.39
Col B5 0 1.2D+1.6L Combination -50918.81 1670.39 426.43
Col C1 0 1.2D+1.6L Combination -56699.32 -2708.36 -2424.51
Col C3 0 1.2D+1.6L Combination -87924.48 1111.56 -5390.8
Col C4 0 1.2D+1.6L Combination -63863.85 1076.52 -4527.81
Col C5 0 1.2D+1.6L Combination -25630.58 799.39 -2287.57

6.2.DIMENSIONADO DE COLUMNAS SEGÚN NORMA ADOPTADA

Esta parte la veremos en las planillas para cálculo de secciones adoptadas. Se usó para el
dimensionamiento el programa pcaColumn.

6.3.GRAFICOS DE LAS SECIONES TRANSVERSALES CON SUS ARMADURAS

Podremos observar estas graficas en las siguientes paginas:

17
Diseño de zapatas aisladas Fundaciones I

PARTE III: DISEÑO Y DIMENSIONADO DE ELEMENTOS


ESTRUCTURALES

6. DISEÑO Y DIMENSIONADO DE COLUMNAS DE HORMIGON ARMADO


6.1.PLANILLAS RESUMEN DE ESFUERZOS AXIALES DE LAS COLUMNAS A NIVEL DE FUNDACION

Frame Station OutputCase CaseType P M2 M3


Text m Text Text Kgf Kgf-m Kgf-m
Col A1 0 1.2D+1.6L Combination -48011.11 -2150.16 1741.18
Col A3 0 1.2D+1.6L Combination -72625.17 4640.64 3243.83
Col A4 0 1.2D+1.6L Combination -49888.8 2692 4405.77
Col A5 0 1.2D+1.6L Combination -23772.45 1085.7 1179.37
Col B1 0 1.2D+1.6L Combination -76714.81 -1277.49 1016.77
Col B2 0 1.2D+1.6L Combination -96861.28 580.84 495.2
Col B3 0 1.2D+1.6L Combination -127442.24 -391.82 1014.5
Col B4 0 1.2D+1.6L Combination -118966.05 1576.59 751.39
Col B5 0 1.2D+1.6L Combination -50918.81 1670.39 426.43
Col C1 0 1.2D+1.6L Combination -56699.32 -2708.36 -2424.51
Col C3 0 1.2D+1.6L Combination -87924.48 1111.56 -5390.8
Col C4 0 1.2D+1.6L Combination -63863.85 1076.52 -4527.81
Col C5 0 1.2D+1.6L Combination -25630.58 799.39 -2287.57

6.2.DIMENSIONADO DE COLUMNAS SEGÚN NORMA ADOPTADA

Esta parte la veremos en las planillas para cálculo de secciones adoptadas. Se usó para el
dimensionamiento el programa pcaColumn.

6.3.GRAFICOS DE LAS SECIONES TRANSVERSALES CON SUS ARMADURAS

Podremos observar estas graficas en las siguientes paginas:

30
Diseño de zapatas aisladas Fundaciones I

6.4.PLANILLA RESUMEN DE LAS SECCIONES CON SUS DIFERENTES TIPOS DE ARMADURA

COLUMNA SECCIÓN REFUERZO ESQUEMA


(cm) DE ACERO
A1
35 x 35 8 ø16

35 x 35 8 ø16
A3
35 x 35 8 ø16
A4
35 x 35 8 ø16
A5
35 x 35 8 ø16
B1
35 x 35 8 ø16
B2
35 x 35 8 ø16
B3
35 x 35 8 ø16
B4
35 x 35 8 ø16
B5
35 x 35 8 ø16
C1
35 x 35 8 ø16
C3
35 x 35 8 ø16
C4
35 x 35 8 ø16
C5

31
Diseño de zapatas aisladas Fundaciones I

PARTE IV: ANALISIS, DISEÑO Y DIMENSIONADO DE FUNDACIONES

32
Diseño de zapatas aisladas Fundaciones I

7.1.2. PLANILLA DE ACEROS DE TODAS LAS ZAPATAS

Elementos Cantidades
Long. Long total Total masa
Pos. ɸ Masa (kg)
Nombre Cant. (m) Elemt. Total (m) (kg)

2 16 0.8 8 8 6.8 10.7


Zapata A1 1 39.184
3 16 1.8 10 10 18 28.4
4 16 1 8 8 7.6 12
Zapata A3 1 68.888
5 16 2.3 16 16 36 56.9
2 16 0.8 8 8 6.8 10.7
Zapata A4 1 39.974
7 16 1.9 10 10 18.5 29.2
6 16 0.6 8 8 5.1 8.1
Zapata A5 1 19.19
8 12 1.3 10 10 12.5 11.1
4 16 1 8 8 7.6 12
Zapata B1 1 70.152
10 16 2.3 16 16 36.8 58.1
9 16 1 8 8 8 12.6
Zapata B2 1 94.8
11 16 2.6 20 20 52 82.2
12 16 1.1 8 8 8.4 13.3
Zapata B3 1 136.512
13 16 3 26 26 78 123.2
12 16 1.1 8 8 8.4 13.3
Zapata B4 1 132.404
15 16 2.9 26 26 75.4 119.1
14 16 0.9 8 8 7.2 11.4
Zapata B5 1 47.4
16 16 1.9 12 12 22.8 36
14 16 0.9 8 8 7.2 11.4
Zapata C1 1 49.296
18 16 2 12 12 24 37.9
4 16 1 8 8 7.6 12
Zapata C3 1 83.108
19 16 2.5 18 18 45 71.1
14 16 0.9 8 8 7.2 11.4
Zapata C4 1 51.192
20 16 2.1 12 12 25.2 39.8
6 16 0.6 8 8 5.1 8.1
Zapata C5 1 19.634
21 12 1.3 10 10 13 11.5

TOTAL ZAPATAS 851.734

85
Diseño de zapatas aisladas Fundaciones I

PARTE V: PROCESO CONSTRUCTIVO, DOSIFICACION, COMPUTOS


METRICOS, MATERIALES, CONCLUSION Y ANEXOS

8. PROCESO CONSTRUCTIVO DE LAS FUNDACIONES (ZAPATAS AISLADAS)

Sección 1.01 .- Encofrado:


Las zapatas aisladas no requieren de un encofrado ya que estas se construyen directamente sobre el suelo
excavado.

Después de tener el terreno excavado con las dimensiones de la zapata aislada y cota correspondiente, se
vaciará una capa de hormigón pobre sobre la base del terreno con una dosificación 1: 8 (cemento: arena)
para empezar con el armado de los fierros.

Sección 1.02 .-Doblado y montaje de armaduras:


El doblado y cortado de la armadura será realizado de acuerdo a las medidas de los planos estructurales.

La armadura longitudinal será colocada sobre galletas. Los fierros de la armadura transversal serán sujetados
a los fierros de la armadura longitudinal con la separación indicada en los planos estructurales.

Todas las intersecciones de las armaduras deben ser amarradas con alambre para evitar que posibles
desplazamientos de la armadura al momento del vaciado y vibrado del hormigón.

El armado de fierros de las columnas será hecho afuera, es decir no se armará dentro de la zapata, después
será bajado y colocado en plomada respetando sus respectivos ejes.

Eje

estribos de la
columna

plomada
armadura
columna
armadura
transversal armadura
longitudinal

galletas
dosificacion 1 : 3 capa pobre de hormigon
1 : 8 (cemento : arena)

Armadura para zapatas aisladas

86
Diseño de zapatas aisladas Fundaciones I

Se recomienda que los fierros de las zapatas que forman parte de las columnas lleguen a sobrepasar el primer
piso de la construcción en una longitud de 40 veces el diámetro por encima de ésta (primera losa) y así evitar
gastos innecesarios en los empalmes.

Sección 1.03 .- Colocado del hormigón:


El hormigón será vaciado de acuerdo con las especificaciones de preparación y puesta en obra del hormigón.

Antes de vaciar el hormigón se deberá marcar la altura h1 de la zapata en los cuatro lados con clavos y la
altura h/2 amarrando alambre en la armadura de la columna, esto para evitar que se produzcan incrementos
de volumen.

Con la ayuda de un frotacho se irá formando las pendientes laterales de la zapata antes del fraguado del
hormigón.

Después de 8 horas de vaciada la zapata, respetando los ejes de la columna, se deberá vaciar un dado en la
parte superior de la zapata, el cual debe tener las dimensiones de la columna y una altura de 5 cm. La base
de coronamiento de la zapata deberá tener una sección incrementada en 2 ” a las dimensiones de la columna,
la cual servirá para poder asentar el encofrado de la columna.

El dado será vaciado con mortero de cemento con una dosificación 1 : 3 (cemento : arena).

Eje

armadura de la
columna

1" 1"
clavo clavo

5 cm dado

h2
a+2"
zapata
h1 aislada

suelo natural capa pobre de hormigón


1 : 8 (cemento : arena)

Hormigonado de zapatas aisladas

87
Diseño de zapatas aisladas Fundaciones I

b+2" b B

a+2"

Zapata aislada

Sección 1.04 .- Curado:


El curado de las zapatas será realizado por lo menos durante los primeros de 7 días después del vaciado
mediante un vertido permanente de agua, hasta que el hormigón haya alcanzado como mínimo el 70 % de
su resistencia

9. DOSIFICACION DEL HORMIGON PARA FUNDACIONES ZAPATAS AISLADAS


 Adoptar y especificar el método o norma a utilizar.

Para la dosificación usaremos el método ACI

 Desarrollar la dosificación en base a cualquier método.

La dosificación se realiza para determinar las proporciones y cantidades de materiales que se


empleara en el hormigonado de la zapatas de fundación. Para esto se realiza los siguientes pasos
que se desarrollaran continuación.

1) Calculo de resistencia media

Resistencia a la Resistencia a la
compresión especificada compresión requerida
fck fcm
kg/cm2 kg/cm2

Menos de 210 fcm = 1,15 * fck + 20


De 210 a 350 fcm = 1,35 * fck + 15
Más de 350 fcm = 1,20 * fck + 10

88
Diseño de zapatas aisladas Fundaciones I

kg
Para condiciones : f ck  220
m2
f cm  1.35 * f ck  15
f cm  1.35 * 220  15
kg
f cm  298.5 (Re sistencia Media)
m2
2) Relación agua cemento A/C

Tipo de cemento: Portland P  350 Aridos rodados  k


A 1 1
 
C k * f cm  0.5 0.0054 * 298.5  0.5
A
 0.0.4735  0.47
C

Tipo de Cemento Árido Rodado Árido Machacado

Portland P - 250 0,0072 0,0046


Portland P - 350 0,0054 0,0035
Portland P - 450 0,0043 0,0028

3) Módulo de finura

Tamaño Máximo del árido mm.


Módulo de finura 25 30 35 40 45 50 55 60 65 70
mf 5,21 5,45 5,64 5,82 6,0 6,16 6,29 6,4 6,51 6,6

Módulo de finura correspondiente a la parábola de FULLER


mfa=3 (Asumidos, arena (2.5 – 3.5))
mfg=7 (Asumidos, grava (6.0 – 8.0))
Para dimensiones entre 15 a 30 cm. y para vigas, pilares y muros armados tenemos un tamaño
máximo de agregado de 20 a 40mm.
Entonces asumimos un tamaño máximo de agregado de 40mm
Módulo de finura para el tamaño máximo del Árido (de tabla)
mf=5.82

89
Diseño de zapatas aisladas Fundaciones I

4) Porcentaje en peso de arena y grava a mezclar

ARENA
m fg  m f 7.0  5.82
x *100  *100  29.5 %
m fg  m fa 7.0  3.0

GRAVA
m f  m fa 5.82  3.0
y *100  *100  70.5 %
m fg  m fa 7.0  3.0

5) Cantidad de agua en litros por m3 de hormigón

Para consistencia: Blanda

A=185 lt/m3 (Litros por m3 de hormigón)

Consistencia Asiento Áridos Rodados Áridos Machacados


del cm 80 40 20 80 40 20
Hormigón mm mm mm mm mm mm
Seca 0-2 135 155 175 155 175 195
Plástica 3-5 150 170 190 170 190 210
Blanda 6-9 165 185 205 185 205 225
Fluida 10 - 15 180 200 220 200 220 240

6) Cantidad de cemento en Kg. por m3 de hormigón

A 185
 0.47  C 
C 0.47
C  393.6 kg

90
Diseño de zapatas aisladas Fundaciones I

7) Cantidad de agregados por m3 de hormigón


C G1 G 2
 A   1 .03
C a g
393 .6 185 G1 G2
    1 .03
3150 1000 2650 2650
G1 G2
  1 .03  0 .3099
2650 2650
G1 G2
  0 .720047  G1  G 2  0 .720047 * 2650
2650 2650
G1  G 2 1908 .12 
G1 x G1 29 .5
    G1  0 .41844 * G 2 
G2 y G 2 70 .5

DONDE:
C  Pesodel cementoen kg
A Volumendel agua en lt
G1  Peso de la arenaen kg
G2  Peso de la gravaen kg
kg
 C  Peso especificoreal del cementoen
m3
kg
 a  Peso especificoreal del arenaen 3
m
kg
 g  Peso especificoreal del gravaen 3
m
x  Porcentajeen pesode arenaen %
y  Porcentajeen pesode gravaen %

Material Peso Específico kg/m3


YReal YAparente
Cemento 3150 1100
Arena 2650 1550
Grava 2650 1670
Re mplazando  en 
0.41844 * G 2 G 2 1908.12
1908.12
1.41844 * G 2 1908.12  G 2   1345.224 kg
1.41844
G1  0.41844 * G 2  0.41844 * 1345.224  562.89  563 kg

91
Diseño de zapatas aisladas Fundaciones I

TABLA DE RESUMEN DE AGREGADOS


DESCRIPCION 1 M3 DE HORMIGON 1 BOLSA DE CEMENTO
Cemento 393,6 kg 50 kg
Agua 185 lt 30,8 lt
Arena 563 kg 93.83 kg
grava 1345.22 kg 224,2 kg

Sea el cemento 1 entonces dividimos todo entre 393.6

393.6/393.6 = 1
563/393.6 = 1.43
1345.22/393.1 = 3.42

DOSIFICACION EN OBRA:

1:2:3 (CEMENTO, ARENA, GRAVA)

10. COMPUTOS METRICOS DEL HORMIGON DE LAS FUNDACIONES

Esquema estructural y a detalle de zapatas aisladas.


92
Diseño de zapatas aisladas Fundaciones I

RESUMEN DE VOLUMENES DE LAS FUNDACIONES

ZAPATA # BASE LARGO ALTO REBAJE a b VOLUMEN m3 VOLUMEN m3


TIPO ZAPATAS m m m m m m UNITARIO PARCIAL

A1 1 1.90 1.90 0.25 0.05 0.35 0.35 0.80 0.80


A3 1 2.35 2.35 0.35 0.10 0.35 0.35 1.60 1.60
A4 1 1.95 1.95 0.25 0.05 0.35 0.35 0.84 0.84
A5 1 1.35 1.35 0.20 0.05 0.35 0.35 0.31 0.31
B1 1 2.40 2.40 0.35 0.10 0.35 0.35 1.66 1.66
B2 1 2.70 2.70 0.40 0.10 0.35 0.35 2.47 2.47
B3 1 3.10 3.10 0.45 0.10 0.35 0.35 3.72 3.72
B4 1 3.00 3.00 0.45 0.10 0.35 0.35 3.49 3.49
B5 1 2.00 2.00 0.30 0.05 0.35 0.35 1.08 1.08
C1 1 2.10 2.10 0.30 0.05 0.35 0.35 1.19 1.19
C3 1 2.60 2.60 0.35 0.10 0.35 0.35 1.95 1.95
C4 1 2.20 2.20 0.30 0.05 0.35 0.35 1.31 1.31
C5 1 1.40 1.40 0.20 0.05 0.35 0.35 0.34 0.34
VOLUMEN TOTAL m3 20.75

11. PLANILLA DE MATERIALES PARA FUNDACIONES

RESUMEN DE CANTIDADES

DATOS DE DOSIFICACION EN PESO POR METRO CÚBICO

CEMENTO (Kg) 393.6


AGUA (Lts.) 185
ARENA (Kg) 563
GRAVA (Kg) 1345.22
ACERO (Kg) 41.0511

CANTIDAD DE MATERIALES
Bolsas de AGUA GRAVA
Total volumen H° (m3) ARENA (M3) ACERO (Kg)
cemento Lts. (M3)
20.75 164 3838.4 7.440251194 16.71304953 851.734

93
Diseño de zapatas aisladas Fundaciones I

12. CONCLUSIONES Y RECOMENDACIONES

El presente proyecto me sirvió para ampliar mis conocimientos y fortalecer lo aprendido en clase de
fundaciones I. También aprendí a usar paquetes computacionales (SAP200, PCA Column Y
DETAILING) para el cálculo estructural y el armado de acero de fundaciones o zapatas aisladas de
una edificación.
Este proyecto da a conocer que son muy importante las zapatas o fundaciones de una estructura ya
que es el pilar fundamental para sostener el mismo, por tal motivo es necesario calcular con mucha
concentración para no tener fallas, ya que una vez construida las zapatas de una edificación no se
puede solucionar como una viga, columna u otro.
Las zapatas aisladas serán más grandes en superficie mientras más solicitaciones deban soportar por
lo tanto para grandes solicitaciones no serían muy viables dados las grandes áreas que necesitarían,
por lo cual es necesario conocer otros tipos de fundaciones.

94
Diseño de zapatas aisladas Fundaciones I

13. ANEXOS

95
Diseño de zapatas aisladas Fundaciones I

PARTE VI: PLANO ESTRUCTURAL Y DETALLE DE ZAPATAS AISLADAS,


ESCALAS, PLANILLA DE ACEROS Y NOTAS GENERALES

96

También podría gustarte