en Aim: Getting started with ZelioSoft for beginners. The goal of this document is to help a beginner in the automatism field, to get familiarized with ZelioSoft. Thus, the
user will be guided all along the Quick Start in order to create a first program. The list of material to use is given below. Nevertheless, the simulation could be used in
case of a lack of material.
fr Objectif: Commencer avec ZelioSoft pour les dbutants. Le but de ce document est de permettre un dbutant en automatisme de se familiariser avec ZelioSoft.
Ainsi, lutilisateur sera guid tout au long du Quick Start afin de crer un premier programme. La liste du matriel utiliser est fournie ci-dessous. Toutefois, il sera
toujours possible dutiliser le mode simulation si lensemble du matriel nest pas disponible.
de Zweck: Dieses Dokument soll einem Anfnger der Automatisierungstechnik den Einstieg in die ZelioSoft-Welt erleichtern. Der Anwender wird Schritt fr Schritt durch
das/sein erste/s ZelioSoft Programm gefhrt. Die hierzu bentigte Hardware ist nachfolgend aufgefhrt. Fr den Fall, dass Teile der Hardware nicht vorhanden sind,
kann das Programm im Simulations Mode getestet werden.
es Objetivo: Introduccin a ZelioSoft para nuevos usuarios. El propsito del presente documento es el de ayudar a los nuevos usuarios en el campo del automatismo
para que se familiaricen con ZelioSoft. Por lo tanto, se guiar al usuario a lo largo de todo el proceso de inicio rpido para la creacin de un primer programa. A
continuacin se detalla la lista de materiales que deben emplearse. De todas maneras, es posible utilizar la simulacin en el caso de que faltara material.
it Scopo: Guida introduttiva di ZelioSoft per principianti. L'obiettivo di questo documento quello di aiutare gli utenti non esperti in materia di automazione ad utilizzare
ZelioSoft. Nella Guida rapida vengono fornite le istruzioni per la creazione di un primo programma. Di seguito riportato l'elenco del materiale da utilizzare. Tuttavia,
in caso di mancata disponibilit del materiale, possibile utilizzare la simulazione.
po Finalidade: Iniciao ao ZelioSoft para principiantes. A finalidade deste documento ajudar os principiantes no campo do automatismo a ficarem familiarizados com
o ZelioSoft. Assim, o utilizador orientado ao longo de toda a Iniciao Rpida para criar um primeiro programa. A lista de material a utilizar indicada em baixo. No
entanto, pode utilizar-se a simulao em caso de falta de material.
Q1 Q2 Q3 Q4
+ + -
L N
Input Output
VAC
100- 240 24VDC
0.6A
ABL8 MEM24006
V out
L
N
L N + + - - + - I1 I2 IB IC ID IE
MENU
- +
1 2 1 2 1 2 1 2
Q1 Q2 Q3 Q4
3 1
Soft 2
MENU
Zelio
Q1 Q2 Q3 Q4
EIO0000000131-00
1/8
11 - 2008
C Software installation and use / Installation et utilisation du logiciel / Installation und Benutzung der Software
Instalacin y utilizacin del software / Installazione e uso del software / Instalao e utilizao do software
Setup
1
2x Click!
Follow the instructions / Suivre les instructions / Folgen Sie den Anweisungen
2 Siga las instrucciones / Seguire le istruzioni / Siga as instrues
3
Zelio Soft 2
2x Click!
N.B. : Using the USB cable / Utilisation du cable USB / Verwenden des USB-Kabel
Utilizacin del cable USB / Uso del cavo USB / Utilizar o cabo USB
schneider-electric.com link for Windows XP
schneider-electric.com link for Windows 2000
Select
Select the the module
module category category
Create
Create new program
new program
Download a program from a module Select the type of Zelio module to program
Select the type of Zelio module to program
Exit 24VDC 2 DISCR 4 (0-10V) 4 DISCR STA. Yes Yes FBD/LD SR3B102BD
Next >
4 Cancel Help
7
< Back Next > 5 Cancel Help < Back Next > Cancel Help
EIO0000000131-00 2/8
Online Help / Aide en ligne / Online Hilfe
E Ayuda en lnea / Guida in linea / Ajuda Online
Your hand is at
XX cm
MENU
I1 O1
ZELIO
Push Button Flashing Light
B02 B03
TIMER Li
IN OUT TIMERACTIMER B/HTIMER Li TIMER BW
1 2 TIMERAC TIMER B/HTIMER Li BISTABLE
BISTABLE
TIMER Li
SET
Q
RESET
BISTABLE
PRESET
BOOLEAN CAM COUNT
F F
UP DOWN PRESET
COUNT HMETERTIME PROG GAIN
MAX
3
VAL
IN IN MUX MIN
IN TRIGGER
1 0 NUM
1sec TEXT DISPLAY COMPARE
1 2 3 4
H-SPEED
STATUS ARCHIVE COUNT CAN
XT OUT LCD
XT SL SL
OUT CNA In Out
FBD
EIO0000000131-00 3/8
H
Your hand is at
XX cm
ZELIO
MENU
Sensor I4 Display
I1
GAIN
TEXT
TEXT
FBD IN
Locking
TEXT
04
04 B05
B05 Calculation
Calculation output output **
4 2x Click!
EIO0000000131-00 4/8
Check the program / Vrifier le programme / Program bersetzen
I Compruebe el programa / Selezionare il programma / Verifique o programa
Compilation results
COMPIL ATION
COMPILATION SUCCESSFUL.
SUCCESSFU L
Edit
The duration available for the application program in a basic cycle is variable. See the
Help
Cancel Parameters Ctrl+Z online help.
Redo Ctrl+R
Used Available
Cut Ctrl+X Parameter zone (bytes) 112 2304
Copy Ctrl+C Digital data, SFC token, Boolean (number) zones 7(5+2) 576(368+208)
Other data zones (bytes) 15(12+3) 400(200+200)
Paste Ctrl+V
Program zone (bytes) 208(90+118) 4608(2304+2304)
Clear Estimated program time (ms) 0.745 6.000
Cycle time (ms) 10
Select All Ctrl+A
Find...
Program configuration
Check thetheprogram
Check program Click! Do not display simulation or loading in the module
OK ?
Window
Cascade
Tile
Rearrange icons
Run
Split view Run Stop
2
1 Supervision
2 Untitled1 - Edit*
3 3Front Panel
Front Panel
4 Front Panel
Click!
Analog inputs
5 Click!
EIO0000000131-00 5/8
Transfer: Transfer Program, PC > module / Transfert: Transfrer Programme, PC > module / bertragung: Programm bertragen, PC > modul
K Transferencia: Transferir Programa, PC > modulo / Transferisci: Transferisci programma, PC > modulo / Transferncia: Transferir Programa, PC > modulo
1 Click!
Transfer
Transfer Program PC > Module
Module > PC
RUN Module
RUN Module without init of saved data
STOP Module
Compare the program with module data
2
Clear the program
Remote control of front panel
Protection Save in
Disabled
(see the Program Configuration to change this parameter).
OK Cancel ? Yes No
4 7
Configure
Transfer
Configure the module using:
Transfer Program
Error Modem
RUN Module
RUN Module without init of saved data Conexant HD
A D110 MDCV.92
The Zelio Logic Smart Relay is not reacting: STOP Module
Name of the remote station
Check the connection. Compare the program with module data
(error no. DC46_10)
Clear the program
Com Port
Possible causes >> OK Remote control of front panel Com Port
COM1
3
COMMUNICATION
COMMUNIC ATIONconfiguration
configuration COM1
COM1
COM1
Connect COM10
OK ?
1 Disconnect
2
COM12
EIO0000000131-00 6/8
TIPS & TRICKS / TRUCS & ASTUCES / TIPPS & TRICKS
TRUCOS Y CONSEJOS / CONSIGLIO / TRUQUES E DICAS
What you can do with ZelioSoft
Ce que vous pouvez faire avec ZelioSoft
Was Sie mit ZelioSoft machen knnen
Aplicaciones de ZelioSoft
Operazioni possibile con ZelioSoft
O que pode fazer com o ZelioSoft
Click!
Click!
Condition
Condition Condition
End
EIO0000000131-00 7/8
TYPICAL APPLICATIONS / APPLICATIONS TYPIQUES / TYPISCHE ANWENDUNGEN
APLICACIONES COMUNES / APPLICAZIONI TIPICHE / APLICAES TPICAS
Advertising panels
CAM function
CAM
Online Help
EIO0000000131-00 8/8