UNIVERSIDAD NACIONAL DE CAJAMARCA

DISEO DE GALERIA COMERCIAL SISMORESISTENTE

1.-ARUITECTURA

1.1.POBLACION

1.1.1)N.PERS PRIMER PISO A/C.Persona 2


AREA.TOTL 1733.1 m2
SEGN NORMA A.070:
Arti.8

GALERIA AREA(m2) N.PERSONAS


G1 42.93 21
G2 42.13 21
G3 31.94 15
G4 57.7 28
G5 63.59 31 TOTAL/PISO
G6 49.98 24 384
G7 58.55 29
G8 34.7 17 PRIMER PISO
G9 60.06 30
G10 70.55 35
G11 55.3 27
G12 39.88 19
G13 63.59 31
G14 45.38 22
G15 69.97 34
G16 51.98 25
1.1.2)POBLACION EN LOS DEMAS PISOS
piso N.PERSONAS
2do PISO 384
3er PISO 384
4to PISO 384
5to PISO 384
TOTAL EDIFIC 1536
1.2.ANCHO DE PASADISOS PRIMER PISO
1.2.1)ANCHO DE PASADISO (PRINCIPAL)

FORMULA A UTILIZAR

SISMICA
UNIVERSIDAD NACIONAL DE CAJAMARCA

A)POBLACION DE SALIDA 1
GALERIA POBLACION POB.TOTAL
G1 21
G2 21
G3 15
G8 17
G9 30 222
G10 35
G5 31
G11 27
G16 25
ELIJO EL MAYOR
A)POBLACION DE SALIDA 2 POR SER LA MAS
GALERIA POBLACION POB.TOTAL CRITICA
G4 31
G7 29
G8 17
G13 31 189
G14 22
G15 34
G15 25

ENTONCES

POBLACION 222 PERSONAS

SISMICA
UNIVERSIDAD NACIONAL DE CAJAMARCA

CALCULO DEL TIEMPO

datos
N= 222 PERSONAS LUEGO:
A= 4.2 metros
K= 1.3 constante TS= 68.0293407
D= 27.37 metros
V(HORIZONTAL) 1 m/seg

CALCULO DEL ANCHO

ANCHO = 3.26329783 metros

PORLOTANTO
DEBO ELEGIR UN ANCHO QUE SEA MODULO DE
0.6 METROS, QUE SERIA EL INMEDIATO
SUPERIOR AL VALOR CALCULADO, EN ESTE
CASO SERIA:
ANCHO = 3.6 metros

PORLOTANTO SE CONCLUYE DE QUE EL ANCHO FINAL DEL


PASADIZO SERA DE 3.6 METROS, LO CUAL HACE VERIFICAR
QUE EL ANCHO SUPUESTO INICIALMENTE ES EL CORRECTO.

SISMICA
UNIVERSIDAD NACIONAL DE CAJAMARCA

CHEQUEO
ART.13-A-070

3.6 > 3
1.2.2)ANCHO DEL RESTO DE PASADIZOS SECUNDARIOS

P-A
COMO ES LOGICO, POR ESTOS
P-B
PASADISOS HABRA UNA CIRCULACION
P-C MINIMA DE PERSONAS, Y POR ENDE EL
P-D ANCHO QUE SE PUEDA CALCULAR DARA
UN VALOR MENOR AL MINIMO(2.4m), PO
ANCHO ESO CONCLUIMOS DE QUE SE CONSTRUE
2.4 MTROS ESTOS PASADISOS CON EL ANCHO
MINIMO QUE DICE LA NORMA, 2.4
METROS.

1.2.2)ANCHO DE LAS ESCALERAS

1.2.2.1)ESCALERA 1
GALERIA NPERSONASTOTAL TIE DE EVAC.POR ESCALERA
G1 21
G2 21
G3 15 T1=D VERTI
G8 17
G9 30
G10 35 263 T.EVAC-E1= T1
G11 27
G5 31
G4 22
G12 19
G16 25
CALCUL T1
DATOS
N= 263
A= 4.2
K= 1.3
D= 38.54
V(VERT) 0.6

TS1 = 112.401832

ANCHO-E1
EL ANCHO TAMBIEN DEBE SER UN
VALOR MODULO DE 0.6 m,
ENTONCES, SE COMPRUEBA DE QUE
SISMICA
SERA DE 4.2 METROS, VERIFICANDO
QUE EL ANCHO SUPUESTO ES
UNIVERSIDAD NACIONAL DE CAJAMARCA

EL ANCHO TAMBIEN DEBE SER UN


VALOR MODULO DE 0.6 m,
A= 3.89969921 ENTONCES, SE COMPRUEBA DE QUE
SERA DE 4.2 METROS, VERIFICANDO
CONCLUSION QUE EL ANCHO SUPUESTO ES
VALIDO.
TIEMP(P2 a P1)112.40183 SEG
A= 4.2 METROS

1.2.2.1)ESCALERA 2
TIE DE EVAC.POR ESCALERA
GALERIA NPERSONAS TOTAL
G4 28
G6 24 T2=D VERTI VEL=0.6
G7 29
G12 19 187
G13 31 T.EVAC-E2= T2
G14 22
G15 34

CALCUL T2

DATOS
N= 187
A= 3.6
K= 1.3
D= 38.18
V(VERT) 0.6

TS1 = 103.59059829

ANCHO-E2

A= 3.0086385426 EL ANCHO TAMBIEN DEBE SER UN


VALOR MODULO DE 0.6 m,
CONCLUSION
ENTONCES, SE COMPRUEBA DE QUE
TIEMP(P2 a P1) 103.5905983 SERA DE 3.6 METROS, VERIFICANDO
A= 3.6 QUE EL ANCHO SUPUESTO ES
VALIDO.

1.2.3. DOTACION DE SERVICIOS

SISMICA
UNIVERSIDAD NACIONAL DE CAJAMARCA

SS.HH1
GALERIA N.PERSO AREA ARE/C.EMPLNUM.EMPLE SEGN NORMA
G2 21 42.13 4.213 EMPLEADOS
G3 15 31.94 3.194 SSHH.VARO
G8 17 34.7 10 3.47 1 lava
G9 30 60.06 6.006 1 inodor
TOTAL 62 12.67 1 urinario
TOTAL PUBLICO
SSHH.VARO
1 lava
1 inodor
1 urinario

SS.HH2

GALERIA N.PERSO AREA ARE/C.EMPLNUM.EMPLE SEGN NORMA


G1 21 42.93 4.293 EMPLEADOS
G4 28 57.7 5.77 SSHH.VARO
G5 31 63.59 6.359 2 lava
G10 35 70.55 10 7.055 2 inodor
G11 27 55.3 5.53 2 urinario
G12 19 39.88 3.988 PUBLICO
G16 25 51.98 5.198 SSHH.VARO
TOTAL 186 38.193 2 lava
2 inodor
2 urinario

SS.HH3

GALERIA N.PERSO AREA ARE/C.EMPLNUM.EMPLE SEGN NORMA


G6 24 49.98 4.998 EMPLEADOS
G7 29 58.55 5.855 SSHH.VARO
G13 31 63.59 10 6.359 2 lava
G14 22 45.38 4.538 2 inodor

SISMICA
UNIVERSIDAD NACIONAL DE
10CAJAMARCA

G15 34 69.97 6.997 2 urinario


PUBLICO
TOTAL 140 28.747 SSHH.VARO
2 lava
2 inodor
2 urinario

SISMICA
UNIVERSIDAD NACIONAL DE CAJAMARCA

m2

TAL/PISO

SISMICA
UNIVERSIDAD NACIONAL DE CAJAMARCA

L MAYOR
R LA MAS
A

SISMICA
UNIVERSIDAD NACIONAL DE CAJAMARCA

seg

SISMICA
UNIVERSIDAD NACIONAL DE CAJAMARCA

OK

LACION
ENDE EL
AR DARA
2.4m), PO
ONSTRUE
HO
2.4

DE EVAC.POR ESCALERA

VEL=0.6

T.EVAC-E1= T1

SER UN

A DE QUE
SISMICA
RIFICANDO
ES
UNIVERSIDAD NACIONAL DE CAJAMARCA

SER UN

A DE QUE
RIFICANDO
ES

SISMICA
UNIVERSIDAD NACIONAL DE CAJAMARCA

SEGN NORMA
EMPLEADOS
SS.HH.MUJ
1 lavatori
1 inodor

PUBLICO
SS.HH.MUJ
1 lavatori
1 inodor

SEGN NORMA
EMPLEADOS
SS.HH.MUJ
2 lavatori
2 inodor

PUBLICO
SS.HH.MUJ
2 lavatori
2 inodor

SEGN NORMA
EMPLEADOS
SS.HH.MUJ
2 lavatori
2 inodor

SISMICA
UNIVERSIDAD NACIONAL DE CAJAMARCA

PUBLICO
SS.HH.MUJ
2 lavatori
2 inodor

SISMICA
SISMICA

2. PREDIMENSIONAMIENTO

2.1.) DETERMINACION DE ESPESOR DE LOSA

SEGN NILSON ARTHUR


DISEO DE ESTRUCTURAS DE CONCRETO

ELIGIMOS UN SISTEMA APORTICADO


CATEGORIA B
PARA EL ESPESOR DE LOSA
SEGN HARMSEN
LUZ MENOR 6.26 R=L.MAYOR/L.MENOR
CASO GENERA
LUZ NAYOR 9.16 R=

SI:R>2 LOSA EN UNA DIRECCION


LOSA EN DOS DIRECCIONES
SI:R<2 LOSA EN DOS DIRECCIONES

ENTONCES PARA NO ANALISAR DEFLEXIONES

H> 3.5" 8.9075 cm


H> PERI/180 MINIMO
H>=L/40 22.9 cm U.CATOLICA DEL PERU
ENTONCES

H>= 0.1713333333 metros 17.1333333 cm

SEGN UNIVERSIDAD JUARES AUTONOMA DE TABASCO-jose antonio mendoza vidal

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

NUESTRO CASO
Fy= 4200 Kg/cm^2
fc 210 Kg/cm^2
entonces
fs= 2520 OK
para W<=380

PARA UNA PRIMERA ITERACION


espesor (m) pe.esp.(kg/m3peso(kg/m
) 2
)
peso losa: 23 2400 552
piso terminado 100
carga viva: reglamento EL 5 500 250
total: 902 Kg/m2
COMPARO 3800000 Kg/m2

entonces 902 < 3800000 .

ESPESOR DE LOSA:

e= 23 cm

2.1.) DIMENSIONAMIENTO DE VIGAS

PARA EL PRESENTE TRABAJO A CRITERIO


PERSONAL SE DISEARA LA VIGA MAS CRITICA,
ENTONCES LA SECCION QUE RESULTE DEL
ANALISS DE ESTA SERA EL QUE PRIME PARA
TODAS LAS VIGAS DE LA EDIFICACION, POR
RAZON DE ESTETICA YA QUE LAS GALERIAS SON
DE VISTA PUBLICA.

ENTONCES, PRIMERO POR FLEXION

EJE:5-5 TRAMO:E-F
L= 8.96
h= 76 cm

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

b= 38 cm

POR SISMORESISTENTE
L
h b=ancho tributario/20
4
Wu

L= 8.96 m
ANCH.TRIBU 4.2209821429 m b= 21.1049107
b= asumo un valor 40 cm
CALCULAMOS Wu
P.PRO VIGA 162.46108495 Kg/m2
P.LOSA LLENA 552 Kg/m2
P.ACABDO 100 Kg/m2
P.TABIQUER 100 Kg/m2
TOTAL 914.46108495 Kg/m2 CARGA MUERTA

S/C 500 Kg/m2 CARGA VIVA


CONSIDER EL 250 Kg/m2 CARGA VIVA

WU= 1164.46108 Kg/m2

ENTONCES

h= 76.4382099 cm
h= 77 cm

POR INERCIA CALCULO Hi


hi= 78.327847151 cm
hi= 79 cm

ENTONCES PODEMOS DETERMINAR QUE : CAMBIARIA


POSTERIORMENTE
SI ES NECEASRIO
b (viga) 40 cm OTRA SECCION
PARA ENSAMBLAR

UNIVERSIDAD NACIONAL DE CAJAMARCA


CAMBIARIA
SISMICA POSTERIORMENTE
SI ES NECEASRIO
OTRA SECCION
h (viga) 79 cm PARA ENSAMBLAR

2.1.) DIMENSIONAMIENTO DE COLUMNAS

ANALISO LA COLUMNA MAS CRITICA CENTRAL


C-18 EJE E-E
EJE 5--5

AREA MINIMA DE UNA COLUMNA

fc= 210 Kg/cm2

CALCULAMOS P
CARGA MUERTA
area peso total
P.P LOSA 56.46 552 155829.6
P.P.VIGA 2400 58965.6
P.TABIQUE 100 22584 277282.8
PISO TERMI 100 28230
P.COLUMNAS 2400 11673.6
asumo una columna de
b= 40
h= 64
CARGA VIVA
S/C= 500 Kg/m2
NORMA CATEGORIA B 50%
PESO CV 14115 kg un piso
peSO CV total 56460 Kg total 5 pisos

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

TOTAL PARA LOS 5 PISOS

P.TOTAL 333742.8 Kg

CALCULO EL AREA MINIMA CON LA FORMULA

DATOS

P serv= 333742.8 AREA MINIM 3531.6698


COEF.COLU.C 0.45

entonces
b (columna) 40 cm relacion 2.2
h(columna) 88 cm 2.2 <2
b (columna) 43 cm
h(columna) 83 cm 1.93023256 <2
CALCULAMOS UN NUEVO h PARA PODER ENSAMBLAR CON VIGA

columna
b= 43 cm . SI ENSAM
h= 83 cm

SE TIENE
VIGA COLUMNA
b= 40 b= 43
h= 79 h= 83

hi= 77.118327669 cm
hi= 78 cm

FINALMENTE

b (viga) 43 cm
PARA
h (viga) 79 cm TODAS LA
VIGAS

RELACION EN COLUMNA 1.81395349 <2 OK


ENTONCES

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

b (column) 43 cm COLUMNA
h (column) 78 cm CENTRAL
VERIFICO

ANALISO LA COLUMNA MAS CRITICA EN ESQUINA


C-5 EJE E-E
INTERSECC EJE 6Y7

CALCULAMOS P
CARGA MUERTA
area peso total
P.P LOSA 29.29 552 80840.4
P.P.VIGA 2400 48954.72
P.TABIQUE 100 11716 167829.72
PISO TERMI 100 14645
P.COLUMNAS 2400 11673.6
asumo una columna de
b= 40
h= 64
CARGA VIVA
S/C= 500 Kg/m2
NORMA CATEGORIA B 50%
PESO CV 7322.5 kg un piso
peSO CV total 29290 Kg total 5 pisos

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

TOTAL PARA LOS 5 PISOS

P.TOTAL 197119.72 Kg

CALCULO EL AREA MINIMA CON LA FORMULA

DATOS

P serv= 197119.72 AREA MINIM 2681.901


COEF.COLU.C 0.35

entonces
b (columna) 43 cm relacion 1.44186047
h(columna) 62 cm 1.44186047 <2
b (columna) 37 cm
h(columna) 73 cm 1.97297297 <2
SIN HACER CAMBIOS SI SE PUEDE ENSAMBLAR

columna
b= 43 cm NO ENSAM
h= 62 cm

CUANDO SEA NECESARIO ENSAMBLAR

VIGA columna
b= 43 b= 43
h= 79 h= 62

hi= 151.45553483
hi= 152

FINALMENTE

b (viga) MISMA
43 cm
SECCION
h (viga) 79 cm DE VIGA

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA MISMA
SECCION
DE VIGA

b (column) 43 cm COLUMNA
h (column) 62 cm EN
ESQUINA

ANALISO LA COLUMNA LATERAL MAS CRITICA


C-5 EJE A-A
INTERSECC EJE 2--2

CALCULAMOS P
CARGA MUERTA
area peso total
P.P LOSA 20.03 552 55282.8
P.P.VIGA 2400 39057.6
P.TABIQUE 100 8012 124041
PISO TERMI 100 10015
P.COLUMNAS 2400 11673.6
asumo una columna de
b= 40
h= 64
CARGA VIVA
S/C= 500 Kg/m2
NORMA CATEGORIA B 50%
PESO CV 5007.5 kg un piso

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

peSO CV total 20030 Kg total 5 pisos

TOTAL PARA LOS 5 PISOS

P.TOTAL 144071 Kg

CALCULO EL AREA MINIMA CON LA FORMULA

DATOS

P serv= 144071 AREA MINIM 1960.1497


COEF.COLU.C 0.35

entonces
b (columna) 43 cm relacion 1.06976744
h(columna) 46 cm 1.06976744 <2
b (columna) 32 cm
h(columna) 62 cm 1.9375 <2

SIN HACER CAMBIOS SI SE PUEDE ENSAMBLAR


columna
b= 43 cm . NO ENSAM
h= 46 cm

SI FUERA NECESARIO ENSAMBLAR

VIGA COLUMNA
b= 43 b= 43
h= 79 h= 46

hi= 79

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

FINALMENTE b (VIGA) 43 cm
VIGA
h (VIGA) 79 cm
MISMA
SECCION

b (column) 43 cm COLUMNA
h (column) 46 cm LATERAL

RESUMEN DE PREDIMENSIONAMIENTO DEFINITIVO

LOSA

e= 23 cm

VIGA Y COLUMNAS

COLUMNA CENTRAL DEFINITIVO VIGA

b= 43 45 b= 43
h= 78 80 h= 79

COLUMNA EN ESQUINA DEFINITIVO VIGA

b= 43 45 b= 43
h= 62 65 h= 79

DEFINITIVO
COLUMNA EN LATERAL VIGA

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

b= 43 45 b= 43
h= 46 50 h= 79

COMO SE PUEDE VERIFICAR QUE LAS SECCIONES


ESTAN CORRECTAS PARA ASI PODER ENSAMBLAR
LAS VOGAS CON COLUMNAS

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

L.MAYOR/L.MENOR
1.46325879

A EN DOS DIRECCIONES

ATOLICA DEL PERU

e antonio mendoza vidal

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

OK

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

cm

CAMBIARIA
POSTERIORMENTE
SI ES NECEASRIO
OTRA SECCION
PARA ENSAMBLAR

UNIVERSIDAD NACIONAL DE CAJAMARCA


CAMBIARIA
POSTERIORMENTE SISMICA
SI ES NECEASRIO
OTRA SECCION
PARA ENSAMBLAR

Kg

TOTAL

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

cm2

NO CUMPLE

OK

PARA
TODAS LA
VIGAS

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

COLUMNA
CENTRAL

Kg

TOTAL

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

cm2

OK

ok

MISMA
SECCION
DE VIGA

UNIVERSIDAD NACIONAL DE CAJAMARCA


MISMA SISMICA
SECCION
DE VIGA

COLUMNA
EN
ESQUINA

Kg

TOTAL

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

cm2

OK

OK

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

VIGA
MISMA
SECCION

COLUMNA
LATERAL

INITIVO

DEFINITIVO

45
80

DEFINITIVO

45
80

DEFINITIVO

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

DEFINITIVO

45
80

NES
LAR

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

3. METRADOS DE CARGAS

3.1 CALCULO DEL PESO TOTAL DEL PRIMER PISO


4.1.1) CALCULO DEL PESO TOTAL DE LA LOSA

Tenemos
AREA TOTAL: 1733.1 m2
como:
PESO ESPEC DEL CONCRETO
2400 Kg/m3

e losa= 0.23 m

PORLOTANTO PESO DE LA LOSA

P LOSA 956671.2 Kg

4.1.2) CALCULO DE PESO TOTAL DE LA VIGA

SECCION b= 45 h= 80

VP LONG(m) PESO(Kg) VS LONG(m) PESO(Kg)


eje eje
A-A 28.19 24286.136 1--1 50.41 43429.022
B-B 29 24983.964 2--2 50.95 43894.24
C-C 29.61 25509.489 3--3 51.72 44557.608
D-D 30.05 25888.556 4--4 53.02 45677.578
E-E 31.3 26965.451 5--5 53.73 46289.255
F-F 30.93 26646.69 6--6 30.38 26172.856
G-G 30.82 26551.923 7--7 20.88 17988.454
H-H 30.53 26302.083
I-I 30.42 26207.317
J-J 30.16 25983.323
K-K 30.13 25957.477
L-L 13.64 11751.078
TOTAL 297033.49 Kg 268009.01

EL METRADO SE REALIZO DESCONTADO AL PERALTE DE


LA VIGA EL ESPESOR DE LA LOSA, DEBIDO A QUE ESTA
SECCION YA FUE METRADO COMO LOSA TOTAL DE LA
EDIFICACION.

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

3.1.3) CALCULO DEL PESO TOTAL DE ACABADOS

Primer Piso
Piso terminado = 100.00 kg/m2
Area = 1733.1 mts2
carga viva: 500 kg/m2 EL 50% 250
Peso-acabados = 606585 kg

3.1.4) CALCULO DEL PESO TOTAL DE MUROS

PESO ESPECIFICO DE MUROS 1800 Kg/m3


hlibre 3.6 hviga 80 cm
elosa 23 e muro 0.15 m
MASA h( vent,puerta) ancho PESO(Kg)
m1 2.1 2.5 1417.5 LOS
m2 3.6 2.58 2507.76 VALORES
m3 3.6 3.66 3557.52 CERO SON
m4 3.6 2.42 2352.24 PESOS DE
LAS
m5 3.6 2.59 2517.48
PUERTAS
m6 2.1 2.5 1417.5 ENROLLABLE
m7 3.6 2.59 2517.48 S, QUE SERA
m8 3.6 2.63 2556.36 DE LA
m9 2.1 2.5 1417.5 MISMA DE
m10 3.6 2.64 2566.08 ALTURA
LIBRE DEL
m11 3.6 2.4 2332.8
PISO
m12 3.6 2.3 2235.6
m13 2.1 2.5 1417.5
m14 3.6 2.3 2235.6
m15 3.6 2.4 2332.8
m16 3.6 1.87 1817.64
m17 2.1 2.5 1417.5
m18 3.6 1.86 1807.92
m19 3.6 4.56 4432.32
m20 3.6 5.06 4918.32
m21 3.6 6.23 6055.56
m22 3.6 1.58 1535.76
m23 0 2.4 0
m24 3.6 1.35 1312.2
m25 3.6 1.47 1428.84
m26 2.1 2.5 1417.5
m27 3.6 1.47 1428.84
m28 2.8 7.1 5367.6
m29 3.6 1.53 1487.16

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

m30 0 2.4 0
m31 3.6 1.75 1701
m32 3.6 1.83 1778.76
m33 0 2.4 0
m34 3.6 1.55 1506.6
m35 3.6 8.16 7931.52
m36 3.6 6.07 5900.04
m37 3.6 7.98 7756.56
m38 3.6 1.06 1030.32
m39 0 2.4 0
m40 3.6 1.29 1253.88
m41 3.6 0.95 923.4
m42 0 2.4 0
m43 3.6 0.95 923.4
m44 3.6 3.63 3528.36
m45 3.6 5.07 4928.04
m46 3.6 2.05 1992.6
m47 2.1 2.5 1417.5
m48 3.6 2.05 1992.6
m49 3.6 1.34 1302.48
m50 0 2.4 0
m51 3.6 1.34 1302.48
m52 3.6 6.59 6405.48
m53 3.6 0.61 592.92
m54 0 2.4 0
m55 2.1 2.5 1417.5
m55-a 3.6 2.05 1992.6
m55-b 3.6 2.05 1992.6
m56 3.6 0.61 592.92
m57 3.6 1.2 1166.4
m58 3.6 5.24 5093.28
m59 4.17 3.04 3422.736
m60 3.6 2.72 2643.84
m60-a 1.03 1.2 333.72
m60-b 1.03 1.2 333.72
m61 4.17 7.19 8095.221
m62 4.17 3.04 3422.736
m63 3.6 2.72 2643.84
m64 3.6 6.59 6405.48
m65 3.6 3.16 3071.52
m66 0 2.4 0
m67 3.6 2.6 2527.2
m68 3.6 2.05 1992.6
m69 2.1 2.5 1417.5
m70 3.6 2.05 1992.6

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

m71 3.6 2.05 1992.6


m72 2.1 2.5 1417.5
m73 3.6 2.05 1992.6
m74 3.6 1.93 1875.96
m75 0 2.4 0
m76 3.6 2.77 2692.44
m77 3.6 6.59 6405.48
m78 3.6 6.59 6405.48
m79 3.6 6.59 6405.48
m80 3.6 1.16 1127.52
m81 3.6 4.01 3897.72
m82 3.6 6.62 6434.64
m83 1.03 1.2 333.72
m84 3.6 0.95 923.4
m85 3.6 2.31 2245.32
m86 3.6 0.86 835.92
m87 3.6 1.31 1273.32
m88 4.17 2.15 2420.685
m89 4.17 2.75 3096.225
m90 1.03 1.2 333.72
m91 3.6 3.86 3751.92
m91-a 1.03 1.2 333.72
m92 4.17 7.64 8601.876
m92-a 4.17 1.93 2172.987
m92-b 1.03 1.15 319.815
m93 2.8 4.8 3628.8
m94 3.6 2.12 2060.64
m95 3.6 1.17 1137.24
m96 3.6 4.19 4072.68
m97 4.17 3.36 3783.024
m98 3.6 7.19 6988.68
m99 3.6 3.78 3674.16
m99-a 1.6 1.2 518.4
m100 3.6 6.23 6055.56
m101 3.6 1.58 1535.76
m102 3.6 1.46 1419.12
m103 2.1 2 1134
m104 3.6 1.48 1438.56
m105 3.6 5 4860
m106 3.6 7.19 6988.68
m107 3.6 2.23 2167.56
m108 0 2.4 0
m109 3.6 2.47 2400.84
m110 3.6 2.35 2284.2
m111 2.1 2.5 1417.5

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

m112 3.6 2.35 2284.2


m113 3.6 7.1 6901.2
m114 3.6 1.27 1234.44
m115 0 2.4 0
m116 3.6 1.37 1331.64
m117 3.6 2.55 2478.6
m118 2.1 2 1134
m119 3.6 2.55 2478.6
m120 3.6 2.4 2332.8
m121 3.6 2.4 2332.8
m122 3.6 1.41 1370.52
m123 0 2.4 0
m124 3.6 1.25 1215
m125 3.6 2.35 2284.2
m127 2.1 2.5 1417.5
m128 3.6 2.35 2284.2
m129 3.6 1.8 1749.6
m130 0 2.4 0
m131 3.6 2.12 2060.64
m132 3.6 7.19 6988.68
m133 3.6 6.32 6143.04
m134 3.6 5.1 4957.2
m135 3.6 2.16 2099.52
m136 2.1 2 1134
m137 3.6 2.16 2099.52
m138 1.03 1.6 444.96
m139 3.6 2.25 2187
m140 3.6 7.19 6988.68
m141 3.6 1.6 1555.2
m142 3.6 7.43 7221.96
m143 3.6 2.71 2634.12
m144 2.1 2 1134
m145 3.6 2.41 2342.52
m146 3.6 1.49 1448.28
m147 0 2.4 0
m148 3.6 1.26 1224.72
m149 3.6 7.64 7426.08
m150 3.6 2.4 2332.8
m151 3.6 1.38 1341.36
m152 0 2.4 0
m153 3.6 1.39 1351.08
m154 3.6 2.35 2284.2
m155 2.1 2.5 1417.5
m156 3.6 2.35 2284.2
m157 3.6 0.61 592.92

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

m158 0 2.4 0
m159 3.6 0.61 592.92
m160 3.6 7.19 6988.68
m161 3.6 1.61 1564.92
m61-a 1.03 1.2 333.72
m162 4.17 2.4 2702.16
m163 4.17 3.4 3828.06
m164 4.17 1.8 2026.62
m164-a 1.7 1.7 780.3
m165 2.8 7.19 5435.64
m166 4.17 3.5 3940.65
m167 4.17 2.55 2871.045
m167-a 1.7 1.15 527.85
m168 4.17 0.91 1024.569
m169 3.6 5.07 4928.04
m170 3.6 3.63 3528.36
m171 3.6 3.63 3528.36
m172 3.6 1.54 1496.88
m173 2.1 2 1134
m174 3.6 1.54 1496.88
m175 3.6 1.36 1321.92
m176 2.1 2.5 1417.5
m177 3.6 1.36 1321.92
m1-1 3.6 2.83 2750.76
TOTAL DE MU 457455.52 Kg

PORLOTANTO EL PESO TOTAL DEL PRIMER PISO SERA

P TOTAL 1er PISO= 2585754 KILOGRAMO

SE RECOMIENDA

QUE POR CADA PISO SUPERIOR SE


REDUSCA EL PESO EN UN 10%,
TENIENDO EN CUENTA ESTO TENEMOS:

PISO PESO UNIDAD ALTURA(m)


1 2585754 Kg 4.4
2 2327178.8 Kg 4.4
3 2094460.9 Kg 4.4
4 1885014.8 Kg 4.4

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

5 1696513.3 Kg 4.4
total 10588922 Kg 22

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

Kg

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

Kg/m2

LOS
VALORES
CERO SON
PESOS DE
LAS
PUERTAS
ENROLLABLE
S, QUE SERA
DE LA
MISMA DE
ALTURA
LIBRE DEL
PISO

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

metros

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

4. ANALISIS SISMICO

4.1. DATOS PARA EL CALCULO DEL CORTANTE BASAL

Donde:
Z: Factor de zona ssmica
U: Categora de Edificacin
S: Tipo de suelo
P: Peso total de la Estructura
R: Coeficiente de Reduccin

datos:
Espesor de Losa 0.23 m
Altura de Edificacin 4.40 m
Peso de Albailera 1800.00 kg/m3

ENTONCES

Factor de zona sismica Z= 0.4 Cajama zona 3

Categoria de la edif B edif.con gran cantidad de personas


Peso el 50% de C.VIVA

Fctor de uso: U= 1.3 de acuerd a la categoria

tipo de suelo: CL-OL : arcilla inorganica de baja plasticidad


ENTONCES TIPO: S3
Tp= 0.9
S= 1.4

Coefciente de reduccion R
Rxx = 8.0 : porticos
Ryy = 6.0 : porticos

SE TIENE LAS CARGAS SISMICAS POR PISO

PISO PESO UNIDAD ALTURA(m)


1 2585754 Kg 4.4
2 2327178.8 Kg 4.4
3 2094460.9 Kg 4.4
4 1885014.8 Kg 4.4
5 1696513.3 Kg 4.4

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

total 10588922 Kg 22

4.2.ANALISIS DEL EJE XX


4.2.1.CALCULO DEL PERIODO FUNDAMENTAL

hn: altura total del edificio


h
T n hn= 22
CT Ct:factor para porticos
CT 35

calculo
T= 0.6285714 Seg <

CHEQUEO 0.62857143 < 0.7 .

CALCULO DE "C"

Tp Entonces el calculo:
C 2.5
T
C= 3.57954545

ENTONCES CHEQUEO:
3.57954545 < 2.5 NO CUMPLE

COMO NO CUMPLE:

C= 2.5

CALCULO DE LA CORTANTE BASAL

ENTONCES:
ZUCS
V P V= 2408979.78
R V= 2408.97978

CHEQUEO

Se debe considerar para C/R la siguiente condicion


C/R>0.125
ENTONCES
C/R= 0.3125 > 0.125 .

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

4.2.2. DISTRIBUCION DE FUERZA SISMICA


Fi = (
)/
PISO Pi(tn) hi Pi*hi()
Pihi/(pihi) Fi
1 2586 4.4 11377.3186 0.08751586 210.823942
2 2327 8.8 20479.1734 0.15752855 379.483096
3 2094 13.2 27646.8841 0.21266355 512.30218
4 1885 17.6 33176.2609 0.25519625 614.762616
5 1697 22 37323.2935 0.28709579 691.607943
TOTAL 130002.931 2408.97978

4.3.ANALISIS DEL EJE YY

4.3.1.CALCULO DEL PERIODO FUNDAMENTAL

hn hn: altura total del edificio


T hn= 22
CT Ct:factor para porticos
CT 60

calculo
T= 0.3666667 Seg

CHEQUEO 0.36666667 < 0.7

CALCULO DE "C"

Tp Entonces el calculo:
C 2.5
T C= 6.13636364

ENTONCES CHEQUEO:
6.13636364 < 2.5

COMO NO CUMPLE:

C= 2.5

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

CALCULO DE LA CORTANTE BASAL

ZUCS ENTONCES:
V P
R V= 3211973.04
V= 3211.97304

CHEQUEO

Se debe considerar para C/R la siguiente condicion


C/R>0.125
ENTONCES
C/R= 0.41666667 > 0.125 .

4.3.2. DISTRIBUCION DE FUERZA SISMICA


Fi = (
)/
PISO Pi(tn) hi Pi*hi()
Pihi/(pihi) Fi
1 2586 4.4 11377.3186 0.08751586 281.09859
2 2327 8.8 20479.1734 0.15752855 505.977462
3 2094 13.2 27646.8841 0.21266355 683.069573
4 1885 17.6 33176.2609 0.25519625 819.683488
5 1697 22 37323.2935 0.28709579 922.143924
TOTAL 130002.931 3211.97304

4.3.3. COMPARO CON LOS DESPLAZAMIENTOS DE LA ESTRUCTURA

EJE XX
PISO Aceleracion Tn C -estr nor>estr
1 9.1393418 0.12571429 2.5 0.36586802 2.2
2 9.26611603 0.25142857 2.5 1.48377228 4.4
3 8.51826808 0.37714286 2.5 3.0690456 6.6
4 6.79861772 0.50285714 2.5 4.35461869 8.8

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

5 3.99918689 0.62857143 2.5 4.00240688 11

EJE YY
PISO Aceleracion Tn C -estr nor>estr
1 12.1857891 0.07333333 2.5 0.16599567 2.2
2 12.3548214 0.14666667 2.5 0.67319298 4.4
3 11.3576908 0.22 2.5 1.39243735 6.6
4 9.06482362 0.29333333 2.5 1.97570663 8.8
5 5.33224919 0.36666667 2.5 1.81590683 11

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

ama zona 3

tidad de personas

acuerd a la categoria

lasticidad

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

0.7

OK

Kg
Tn

OK

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

Vi(tn) -norma
2408.97978 3.08
2198.15583 6.16
1818.67274 9.24
1306.37056 12.32
691.607943 15.4

< 0.7

. OK

NO CUMPLE

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

Kg
Tn

OK

Vi(tn) -norma cm
3211.97304 2.2
2930.87445 4.4
2424.89698 6.6
1741.82741 8.8
922.143924 11

ENTONCES
SI CUMPLE
SI CUMPLE
SI CUMPLE
SI CUMPLE

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

SI CUMPLE

ENTONCES
SI CUMPLE
SI CUMPLE
SI CUMPLE
SI CUMPLE
SI CUMPLE

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

4. DENSIDAD DE MUROS

Albailera Concreto Armado


Donde : Em = 500xf'm E=(15000*f'c^1/2)
f'm = 65.00 kg/cm2 f'c= 210
Em= 32500.0 E= 217371

4.1.DENSIDAD DE MUEROS EJES XX

MASA LONG LON(CM) t(cm) DENSIDAD


m1 254 Err:509 15 3810
m2 254 Err:509 15 3810
m3 363 Err:509 15 5445
m4 240 Err:509 15 3600
m5 275 Err:509 15 4125
m6 247 Err:509 15 3705
m7 257 Err:509 15 3855
m8 263 Err:509 15 3945
m9 250 Err:509 15 3750
m10 264 Err:509 15 3960
m11 240 Err:509 15 3600
m12 230 Err:509 15 3450
m13 250 Err:509 15 3750
m14 230 Err:509 15 3450
m15 240 Err:509 15 3600
m16 186 Err:509 15 2790
m17 250 Err:509 15 3750
m18 186 Err:509 15 2790
m19 456 Err:509 15 6840
m20 50 Err:509 15 750
m82 67 Err:509 15 1005
m85 0.23 Err:509 15 3.45
m93 48 Err:509 15 720
m102 15 Err:509 15 225
m103 20 Err:509 15 300
m104 15 Err:509 15 225
m21 6.23 Err:509 15 93.45
m81 4.01 Err:509 15 60.15
m28 7.1 Err:509 15 106.5
m35 8.16 Err:509 15 122.4
m37 7.98 Err:509 15 119.7
m44 3.63 Err:509 15 54.45
m45 5.07 Err:509 15 76.05
m49 1.34 Err:509 15 20.1
m51 1.34 Err:509 15 20.1

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

m53 0.61 Err:509 15 9.15


m56 0.61 Err:509 15 9.15
m59 3.04 Err:509 15 45.6
m60 2.72 Err:509 15 40.8
m60-a 1.2 Err:509 15 18
m60-b 1.2 Err:509 15 18
m62 3.04 Err:509 15 45.6
m63 2.72 Err:509 15 40.8
m65 3.16 Err:509 15 47.4
m67 2.6 Err:509 15 39
m74 1.93 Err:509 15 28.95
m76 2.77 Err:509 15 41.55
m80 1.16 Err:509 15 17.4
m83 1.2 Err:509 15 18
m84 0.95 Err:509 15 14.25
m86 0.86 Err:509 15 12.9
m87 1.31 Err:509 15 19.65
m88 2.15 Err:509 15 32.25
m91 3.86 Err:509 15 57.9
m91-a 1.2 Err:509 15 18
m92-a 1.93 Err:509 15 28.95
m92-b 1.15 Err:509 15 17.25
m97 3.36 Err:509 15 50.4
m107 2.23 Err:509 15 33.45
m109 2.47 Err:509 15 37.05
m129 1.8 Err:509 15 27
m131 2.12 Err:509 15 31.8
m138 1.6 Err:509 15 24
m139 2.25 Err:509 15 33.75
m157 0.61 Err:509 15 9.15
m159 0.61 Err:509 15 9.15
m161 1.61 Err:509 15 24.15
m61-a 1.2 Err:509 15 18
m163 3.4 Err:509 15 51
m166 3.5 Err:509 15 52.5
m169 5.07 Err:509 15 76.05
m170 3.63 Err:509 15 54.45
m142 7.43 Err:509 15 111.45
m133 6.32 Err:509 15 94.8
m113 7.1 Err:509 15 106.5
m94 2.12 Err:509 15 31.8
m95 1.17 Err:509 15 17.55
m96 4.19 Err:509 15 62.85
m100 6.23 Err:509 15 93.45
m101 1.58 Err:509 15 23.7

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

m120 2.4 Err:509 15 36


m117 2.55 Err:509 15 38.25
m118 2 Err:509 15 30
m119 2.55 Err:509 15 38.25
m121 2.4 Err:509 15 36
m135 2.16 Err:509 15 32.4
m136 2 Err:509 15 30
m137 2.16 Err:509 15 32.4
m141 1.6 Err:509 15 24
m143 2.71 Err:509 15 40.65
m144 2 Err:509 15 30
m145 2.41 Err:509 15 36.15
m150 2.4 Err:509 15 36
m171 3.63 Err:509 15 54.45
m172 1.54 Err:509 15 23.1
m173 2 Err:509 15 30
m174 1.54 Err:509 15 23.1
TOTAL 24738.23 80191.65

4.1.DENSIDAD DE MUEROS EJES YY

MASA LONG LONG(cm) t(cm) DENSIDAD


m1 36 36 15 51
m2 36 36 15 51
m3 52 52 15 67
m4 34 34 15 49
m5 37 37 15 52
m6 35 35 15 50
m7 37 37 15 52
m8 8 8 15 23
m9 8 8 15 23
m10 8 8 15 23
m11 7 7 15 22
m12 7 7 15 22
m13 8 8 15 23
m14 7 7 15 22
m15 7 7 15 22
m16 6 6 15 21
m17 8 8 15 23
m18 6 6 15 21
m19 14 14 15 29

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

m20 50 50 15 65
m82 66 66 15 81
m85 23 23 15 38
m93 48 48 15 63
m102 15 15 15 30
m103 20 20 15 35
m104 15 15 15 30
m1-1 2.83 2.83 15 17.83
m22 1.58 158 15 173
m24 1.35 135 15 150
m25 1.47 147 15 162
m26 2.5 250 15 265
m27 1.47 147 15 162
m29 1.53 153 15 168
m31 1.75 175 15 190
m34 1.55 155 15 170
m32 1.83 183 15 198
m36 6.07 607 15 622
m38 1.06 106 15 121
m40 1.29 129 15 144
m41 0.95 95 15 110
m43 0.95 95 15 110
m46 2.05 205 15 220
m47 2.5 250 15 265
m48 2.05 205 15 220
m52 6.59 659 15 674
m55 2.5 250 15 265
m55-a 2.05 205 15 220
m55-b 2.05 205 15 220
m57 1.2 120 15 135
m58 5.24 524 15 539
m61 7.19 719 15 734
m64 6.59 659 15 674
m68 2.05 205 15 220
m69 2.5 250 15 265
m70 2.05 205 15 220
m71 2.05 205 15 220
m72 2.5 250 15 265
m73 2.05 205 15 220
m77 6.59 659 15 674
m78 6.59 659 15 674
m79 6.59 659 15 674
m92 7.64 764 15 779
m98 7.19 719 15 734
m106 7.19 719 15 734

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

m110 2.35 235 15 250


m111 2.5 250 15 265
m112 2.35 235 15 250
m125 2.35 235 15 250
m127 2.5 250 15 265
m128 2.35 235 15 250
m132 7.19 719 15 734
m140 7.19 719 15 734
m149 7.64 764 15 779
m154 2.35 235 15 250
m155 2.5 250 15 265
m156 2.35 235 15 250
m160 7.19 719 15 734
m164 1.8 180 15 195
m164-a 1.7 170 15 185
m167 2.55 255 15 270
m167-a 1.15 115 15 130
m162 2.4 240 15 255
m165 7.19 719 15 734
m168 0.91 91 15 106
m175 1.36 136 15 151
m176 2.5 250 15 265
m177 1.36 136 15 151
m151 1.38 138 15 153
m153 1.39 139 15 154
m146 1.49 149 15 164
m148 1.26 126 15 141
m134 5.1 510 15 525
m122 1.41 141 15 156
m124 1.25 125 15 140
m114 1.27 127 15 142
m116 1.37 137 15 152
m105 5 500 15 515
m99 3.78 378 15 393
m99-a 1.2 120 15 120
TOTAL 22598.83 24068.83

CHEQUEO PARA CADA EJE


DENSIDAD EJE XX 80191.65 cm2

()//56

suma(Lt) 80191.65 cm2

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

Ap= 1733.1 173310000 cm2

0.00231353 >= 0.065 NO CUMPLE

ENTONCES: DISEO PLACAS

ENTONCES SEGUN LA NORMA SI ESTA CONDICION NO


CUMPLE ENTONCES TENEMOS DOS OPCIONES,
AAUMENTAMOS EL ESPESOR DEL MURO O SINO PONEMOS
PLACAS EN SU LUGAR.
DENSIDAD EJE XX 24068.83 cm2

()//56

suma(Lt) 24068.83 cm2


Ap= 1733.1 173310000 cm2

0.00069439 >= 0.065 NO CUMPLE

ENTONCES: DISEO PLACAS

ENTONCES SEGUN LA NORMA SI ESTA CONDICION NO


CUMPLE ENTONCES TENEMOS DOS OPCIONES,
AAUMENTAMOS EL ESPESOR DEL MURO O SINO PONEMOS
PLACAS EN SU LUGAR.

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

reto Armado
5000*f'c^1/2)
kg/cm2

UNIDAD
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2

UNIDAD
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2
cm2

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

NEMOS

NEMOS

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

5. DISEO DE PLACAS

5.1.CONDICIONES GENERALES PARA LAS PLACAS

CHEQUEO
A.COLUM 26.832 m2
A TOTAL 1733.1 m2

0.01548208 < 25% ..

5.2.EN FUNCION DE LOS MUROS


cm m
LONG.DE MUROS EJE XX 24738.23 247.3823 UN PISO
t de muro 15 0.15

CHEQUEO RELACION PARA CADA PISO

SI NO CUMPLE SE AUMENTE EL
()//150
ESPESOR T

PISO LXX LONG ACUM AREA PISO L*T/Ap N/150


1 247.3823 247.3823 0.02141097 0.00666667
2 494.7646 0.04282193 0.01333333
3 742.1469 1733.1 0.0642329 0.02
4 989.5292 0.08564386 0.02666667
5 1236.9115 0.10705483 0.00666667

5.3.EN FUNCION DE LOS MUROS


cm m
LONG.DE MUROS EJE XX 22598.83 225.9883 UN PISO
t de muro 15 0.15

CHEQUEO RELACION PARA CADA PISO

()//150 SI NO CUMPLE SE AUMENTE EL


ESPESOR T

PISO LXX LONG ACUM AREA PISO L*T/Ap N/150


1 225.9883 225.9883 0.01955931 0.00666667
2 473.3706 0.04097028 0.01333333
3 720.7529 1733.1 0.06238124 0.02
4 968.1352 0.08379221 0.02666667
5 1215.5175 0.10520318 0.00666667

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

5.2.CALCULO DEL ESFUERZO DE CORTE DEL CONCRETO

_=0.53()

= 7.68042968 Kg/cm^2 76.8042968

5.3.CALCULO DEL CORTE ACTUENTE EN LA ESTRUCTURA PARA CADA EJE

_=/ A= 31.3651694 m2

=/_ A= 41.8202258 m2

5.3.CALCULO DEL AREA DE CORTE FALTANTE

= = .
entonces A= 4.53316939 EJE XX
A= 14.9882258 EJE YY

5.4.CALCULO DE LA LONGITUD DE PLACAS


t= 0.15 metros

A (placas)= 4.53316939 m2 EJE XX

A (placas)= 14.9882258 m2 EJE YY

LON.PLACAS 30.221129 m EJE XX


LON.PLACAS 99.921506 m EJE YY

UNIVERSIDAD NACIONAL DE CAJAMARCA


SISMICA

OK

NTE EL

VER
CUMPLE
CUMPLE
CUMPLE
CUMPLE
CUMPLE

TE EL

VER
CUMPLE
CUMPLE
CUMPLE
CUMPLE
CUMPLE