Documentos de Académico
Documentos de Profesional
Documentos de Cultura
DEL CALLAO
FACULTAD DE INGENIERA
MECNICA - ENERGA
INTERCAMBIADOR
CALOR
TITULO:
Ing.
PROFESOR:
Pinto
DE
Espinoza
Hernn
Ingeniera Trmica e
Hidrulica experimental
CURSO:
01L
G. HORARIO:
ALUMNOS(S):
Marcelo
CALLAO 2014
NDICE
1.
INTRODUCCIN............................................................................................ 1
2.
OBJETIVOS................................................................................................... 1
3.
4.
5.
6.
NOMENCLATURA..........................................................................................4
7.
TABULACIN DE DATOS................................................................................4
8.
8.6.
COEFICIENTE PELICULAR
8.7.
ha ......................................................................7
COEFICIENTE
PELICULAR EN EL AGUA:
hag ....................................................................7
8.8.
COEFICIENTE
GLOBAL:
8.9.
EFECTIVIDAD
DEL
8.10. NMERO
9.
ICC:
EN EL AIRE
U ........................................................................................... 8
E ..........................................................................................8
DE UNIDADES DE TRANSFERENCIA:
NUT................................................................9
TABULACIN DE RESULTADOS.......................................................................9
9.1.
9.2.
FLUJO PARALELO............................................................................................................ 9
CONTRAFLUJO............................................................................................................. 10
10.
GRAFICAS............................................................................................... 11
11.
CONCLUCIONES Y RECOMENDACIONES.....................................................12
1. INTRODUCCIN
Los intercambiadores de calor sern siempre uno de los indispensables
equipos en la transferencia de calor. Estos han obteniendo usos en los
sistemas de refrigeracin como condensadores o evaporadores, pero
no solo en esta rea sino que tambin en las maquinarias pesadas
utilizan intercambiadores de calor para enfriar el aceite que circula por
el convertidor, caja y sistema hidrulico.
Como podemos ver los intercambiadores son indispensables en el rea
mecnica, es por eso la realizacin de este laboratorio.
En
este
laboratorio
observaremos
el
comportamiento
de
los
2. OBJETIVOS
Pgina 1
Pgina 2
Pgina 3
Pgina 4
Para poder definir el perfil de temperatura lo largo del ICC se toman datos
de la siguientes temperaturas: Te.ag, Ts.ag, T1, T2, T3 y T4
6. NOMENCLATURA
Subndice para el aire
b
Subndice para la temperatura promedio del fluido
Te.ag
Temperatura de entrada del agua
Ts.ag
Temperatura de salida del agua
T1
Temperatura de entrada del aire
T2
Temperatura del tubo en el extremo derecho
T3
Temperatura del tubo en el extremo izquierdo
T4
Temperatura de salida del aire
DTML
Diferencia de temperaturas media logartmica
q
Calor transferido (calor cedido por el aire = calor ganado
por el agua)
Densidad del fluido
Cp
Calor especifico
Viscosidad absoluta
Viscosidad Cinemtica
Conductividad trmica
Difusividad trmica
Pr
Nmero de Prandalt
Pgina 5
7. TABULACIN DE DATOS
Flujo Paralelo:
Te air e
Termos
tato
150
(T1
)
31.3
230
43.5
330
53.1
380
65.4
Tsaire
(T4
)
29.
6
32.
6
34.
9
37
Te agua
Ts agua Vol
(ml
)
t
(se
g)
Td tubo
Ti tubo
(T2)
20
23
100
28
26
(T3
)
23
20
24
100
29
31
24
20
25
100
27
34
24
20
26
100
27
38
25
Te agua
Tsagua
Vol
(ml)
t
(se
g)
(T2)
(T3)
Contraflujo:
Te aire
Tsaire
(T1)
(T4)
150
32.5
29.7
22
23
100
14
27
23
230
42.3
31.8
22
24
100
15
30
23
330
68.4
35.2
22
25
100
16
38
23
380
80.9
36.3
22
26
100
16
40
23
Termost
ato
Td tubo
Ti tubo
T
(K)
(kg/m
3
)
CP(kJ/Kg
.K)
*107(N.s/
m2)
V*106(m2
/s)
K(w/m
.K)
*106(m2
/s)
Pr
250
1.3947
1.006
159.6
11.44
0.0223
15.9
0.72
Pgina 6
300
1.1614
1.007
184.6
15.89
0.0263
22.5
350
0.9950
1.009
208.2
20.92
0.0300
29.9
400
0.8711
1.014
230.1
26.41
0.0338
38.3
0
0.70
7
0.70
0
0.69
0
T (C)
14
16
18
20
22
24
26
28
30
(kg/
m3)
999.27
998.97
998.62
998.23
997.79
997.33
995.81
995.26
995.67
CP(kJ/K
g.K)
4.1867
4.1847
4.1831
4.1818
4.1808
4.1800
4.1794
4.1788
4.1785
*106(N.s/
m2 )
1165.030
1107.171
1053.234
1002.240
955.168
909.076
867.889
830.623
797.281
K(w/m
.K)
0.5864
0.5904
0.5942
0.5978
0.6013
0.6047
0.6080
0.6111
0.6141
*103(m2
/s)
0.136
0.160
0.183
0.206
0.228
0.248
0.266
0.284
0.303
Pr
8.3175
7.8477
7.4148
7.0112
6.6414
6.2444
5.9663
5.6803
5.4251
( 31.3+29.6
)=30.45=303.45 K
2
Para el aire :
Tbaire =
Para el agua :
Tbagua =
=21.55=294.55 K
( 20+23
2 )
kg
J
C pagua =4181.8
3
Kg. K
m
aire =1.1614
kg
J
C paire =1007
3
Kg
.K
m
Pgina 7
q
44.66
Kg
=
=0.0252
s
[ C Paire (T 1T 4 )] [ 1007 (31.329.6) ]
ha
q=ha A 1 DTML a
A 1= D eai L= 0.022221.48=0.1033 m2
DTMLaire= T aire =
T aire
Ta
ln(
)
Tb
T a=T 1T 2=31.326=5.3 C
T b=T 4 T 3=29.623=6.6 C
Pgina 8
DTML aire=
ha =
5.36.6
=5.926 C
5.3
ln(
)
6.6
q
43.234
w
=
=70.624 2
A 1 DTMLa 0.1033 5.926
m K
hag
q=hag A2 DTMLag
A 2= D iag L= 0.0525 1.48=0.244 m2
DTMLagua=T ag=
T agua
T a
ln(
)
T b
DTML ag=
hag=
32.9
=2.949 C
3
ln(
)
2.9
q
43.234
w
=
=60.07 2
A2 DTMLa 0.244 2.949
m K
1
A R eq
Pgina 9
Req =R12+ R k + Rc
R12=
1
1
=
=0.137 C/W
ha ( D 2 L) 70.624 0.1033
r3
52.5
)
ln(
)
r2
22.22
Rk =
=
=2.41 104 C/W
2 K L 2 383 1.48
ln(
Rc =
1
1
=
=0.068 C /W
hag ( D3 L) 60.07 0.244
1
1
w
=
=19.939 2
4
( D3 L ) Req 0.244 ( 0.1327+2.41 10 +0.066 )
m C
U=
q
q max
q
Cmin (T 1Te agua )
C agua=magua
C pagua =0.00357 4181.8=14.908
E=
W
K
W
K
43.234
=25.89
14.908 (31.320)
Pgina 10
U A 2 19.939 0.244
=
=0.326
C min
14.908
9. TABULACIN DE RESULTADOS
9.1. Flujo Paralelo
Calor transferido:
Tbaire
Tbagua
magua
maire
30.45
21.55
0.00357
0.02526
38.05
22.00
0.00344
44.00
22.50
0.00370
51.20
23.00
0.00370
43.234
84
57.577
91
77.303
67
92.764
40
0.00525
0.00422
0.00324
Ta
5.3
12.5
19.1
27.4
Para el aire
DTML
Tb
6.6
8.6
10.9
12
5.9263
10.4287
14.6187
18.6523
ha
Para el agua
T b DTML
Ta
70.6241
53.4470
51.1907
48.1448
3
7
9
12
2.9
4
4
5
2.9497
5.3608
6.1658
7.9957
hag
60.0708
44.0185
51.3835
47.5482
Coeficiente global:
Coeficiente global
R12
Rk
Rc
0.1370
7
0.1811
0.0002
4
0.0002
0.0682
3
0.0931
19.9397
0
14.9318
Pgina 11
4
0.0002
4
0.0002
4
1
0.0797
6
0.0861
9
8
15.2293
9
14.2548
5
C agua
C aire
E (%)
14.9086
14.3945
15.4607
15.4607
25.4323
5.2824
4.2475
3.2664
25.89
46.38
54.98
62.56
9.2. Contraflujo
Calor transferido:
Tbaire
Tbagua
magua
31.10
22.50
0.00713
37.05
51.80
23.00
23.50
0.00665
0.00624
q
29.817
13
55.658
64
78.269
maire
0.01057
0.00526
0.00234
Pgina 12
58.60
24.00
97
104.35
996
0.00624
0.00232
Ta
5.5
12.3
30.4
40.9
Para el aire
DTML
Tb
6.7
8.8
12.2
13.3
ha
6.0803
10.4525
19.9341
24.5690
Para el agua
T b DTML
Ta
47.4725
51.5479
38.0100
41.1193
4
6
13
14
1
1
1
1
2.1640
2.7906
4.6785
4.9260
hag
56.4690
81.7434
68.5651
86.8259
Coeficiente global:
Coeficiente global
R12
Rk
Rc
0.2039
2
0.1878
0
0.2546
8
0.2354
3
0.0002
4
0.0002
4
0.0002
4
0.0002
4
0.0725
8
0.0501
4
0.0597
7
0.0472
0
14.8095
8
17.2073
7
13.0231
3
14.4885
6
C agua
C aire
E (%)
29.8171
27.8293
26.0900
26.0900
10.6490
5.3008
2.3575
2.3399
26.67
51.72
71.55
75.72
Pgina 13
10.
GRAFICAS
Flujo Paralelo
Efectividad
70.00
60.00
50.00
40.00
30.00
20.00
10.00
0.00
NUT
Pgina 14
Contraflujo
Efectividad
80.00
70.00
60.00
50.00
40.00
30.00
20.00
10.00
0.00
NUT
11.
CONCLUCIONES Y RECOMENDACIONES
Se observa que la diferencia de temperatura media logartmica es
mayor para el contraflujo que para el flujo paralelo, por
consiguiente el rea superficial que se requiere para efectuar una
transferencia de calor establecida Q, es ms pequea para el
anterior.
La transferencia de calor se realiza por conveccin forzada y se
realiza de la resistencia al aire, del aire al tubo y del tubo al
agua.
Pgina 15