Está en la página 1de 7

Dosar nr.

RAPORT TEHNIC
Laborator Acustica si Vibratii
Str. Atomistilor, nr 401, Magurele, Judet Ilfov
Telefon: 021-434.01.98/441, Fax: 021-434.02.41

Nr. 1/ data 8.5.2014

/7

1. DATE DE IDENTIFICARE ALE CLIENTULUI

Denumire:
Facultatea Ingineria Sistemelor Biotehnice,
Master- Controlul Zgomotelor si Vibratiilor
Bacanu Alina
E-mail:
alinabacanu87@yahoo.com
aurel_alecu@yahoo.com

2. CERERE/ CONTRACT:
RAPORT INTERN

3. OBIECTUL SOLICITARII:
Determinarea nivelului de zgomot le electrocompresorul cu surub Autoclava ECS 20/25/1 in
regim normal de functionare

4. METODA DE MASURARE (PROCEDURA):


METODE DE MASURARE A NIVELULUI DE ZGOMOT IN INDUSTRIE STAS 7150-77

Dosar nr.

RAPORT TEHNIC
Laborator Acustica si Vibratii
Str. Atomistilor, nr 401, Magurele, Judet Ilfov
Telefon: 021-434.01.98/441, Fax: 021-434.02.41

Nr. 1/ data 8.5.2014

/7

5. DESCRIEREA OBIECTULUI DE MASURARE/LOCATIEI:

-ECS 20/25/1
-CONDITI NORMALE
DE LUCRU

6. DATA SI ORA/INTERVALUL EFECTUARII INCERCARII:


Interval de testare 8.05.2014 orele 11:33-12:01
7. CONDITII DE MEDIU LA DATA SI LOCUL EFECTUARII INCERCARII:
Calibrare
Conditii de mediu :
Start
Temperatura (0)
25.20
Umiditate (%)
54%
Masurarile Zgomotului de fond
Conditii de mediu :
Start
0
Temperatura ( )
27.40
Umiditate (%)
32.3%

Stop

Stop
30.90
27.2%

Dosar nr.

RAPORT TEHNIC
Laborator Acustica si Vibratii
Str. Atomistilor, nr 401, Magurele, Judet Ilfov
Telefon: 021-434.01.98/441, Fax: 021-434.02.41

Masurarile la Relantiu
Conditii de mediu :
Temperatura (0)
Umiditate (%)

Nr. 1/ data 8.5.2014

Start
29.50
32.2%

/7

Stop
25.50
35.0%

8. ECHIPAMENTUL UTILIZAT:
-Sonometru 01dB-Metravib SOLO, spectru 1/1 si 1/3, seria 11605, 01dB-Metravib Software
dBTRATE v4.80;
-Calibrator acustic G.R.A.S. 42AB, seria 31543;
-Termohigrometru Testo 175-H2, seria 38219175/806.

9. REZULTATE:

9.1. Date de intrare si informatii privind punctele de masurare


Zgomotul de fond;
Punctul 1- M14 Ventilator
Punctul 2 M15 Compresor
Punctul 3 M16- Motor
Masurarile la Relantiu;
Punctul 1- M17 Ventilator
Punctul 2 M18 Compresor
Punctul 3 M19- Motor

Dosar nr.

RAPORT TEHNIC
Laborator Acustica si Vibratii
Str. Atomistilor, nr 401, Magurele, Judet Ilfov
Telefon: 021-434.01.98/441, Fax: 021-434.02.41

Nr. 1/ data 8.5.2014

9.2. Prezentarea numerica a nivelurilor de presiune acustica


Frecventa Hz
20 Hz
25 Hz
31.5 Hz
40 Hz
50 Hz
63 Hz
80 Hz
100 Hz
125 Hz
160 Hz
200 Hz
250 Hz
315 Hz
400 Hz
500 Hz
630 Hz
800 Hz
1 kHz
1.25 kHz
1.6 kHz
2 kHz
2.5 kHz
3.15 kHz
4 kHz
5 kHz
6.3 kHz
8 kHz
10 kHz
12.5 kHz
16 kHz

Punctul P1 M17;M14
L
Lf
L-Lf L
6.7
1.7
5
14.4
8 6.4
20.6 15.5 5.1
38.7 20.8 17.9
36.5
32 4.5
37.9 33.7 4.2
41.2 38.3 2.9
53.2 40.6 12.6
63 49.3 13.7
63.9 47.4 16.5
69.3 49.3
20
71.3 53.3
18
70.6 55.2 15.4
74.3 54.6 19.7
72.3 55.8 16.5
74.6 54.6
20
76.3 54.5 21.8
75.2 53.8 21.4
76.5 54.5
22
73.5 52.6 20.9
75.5 50.4 25.1
75.7 49.3 26.4
71
48
23
64.9
47 17.9
63.2 45.6 17.6
60.2 43.5 16.7
56.7 41.9 14.8
54.3 38.9 15.4
48.5 32.6 15.9
45.6 26.8 18.8

1.6
1.1
1.6
0
1.8
1.9
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

L-L
5.1
13.3
19
38.7
34.7
36
53.2
63
63.9
69.3
71.3
70.6
74.3
72.3
74.6
76.3
75.2
76.5
73.5
75.5
75.7
71
64.9
63.2
60.2
56.7
54.3
48.5
45.6

Nivel global de zgomot al sursei la relantiu in punctulP001 LA=65 dB (A)


Nivel global de zgomot de fond in punctul P001 LAF=85,6 dB (A)

/7

Dosar nr.

RAPORT TEHNIC
Laborator Acustica si Vibratii
Str. Atomistilor, nr 401, Magurele, Judet Ilfov
Telefon: 021-434.01.98/441, Fax: 021-434.02.41

Frecventa Hz
20 Hz
25 Hz
31.5 Hz
40 Hz
50 Hz
63 Hz
80 Hz
100 Hz
125 Hz
160 Hz
200 Hz
250 Hz
315 Hz
400 Hz
500 Hz
630 Hz
800 Hz
1 kHz
1.25 kHz
1.6 kHz
2 kHz
2.5 kHz
3.15 kHz
4 kHz
5 kHz
6.3 kHz
8 kHz
10 kHz
12.5 kHz
16 kHz

Nr. 1/ data 8.5.2014

Punctul 2 M18; M15


L
Lf
L-Lf
L
L-L
7.1
6.7
0.4
0 14.9
9.2
5.7
1.3
13.6
21.1
14.8
6.3
1.1
20
38.2
25.4
12.8
0
38.2
37.4
31.8
5.6
1.4
36
34.5
29.9
4.6
1.7
32.8
45.8
41.9
3.9
2.1
43.7
55.3
41.5
13.8
0
55.3
64.8
47.7
17.1
0
64.8
65.8
49.3
16.5
0
65.8
68.2
48.2
20
0
68.2
69.4
55
14.4
0
69.4
72.4
54.2
18.2
0
72.4
73.3
54.8
18.5
0
73.3
74.5
55.8
18.7
0
74.5
74.7
54.5
20.2
0
74.7
78.2
54.1
24.1
0
78.2
74.6
53.9
20.7
0
74.6
75.2
54.5
20.7
0
75.2
73.6
53.8
19.8
0
73.6
73.9
50.8
23.1
0
73.9
74.9
50
24.9
0
74.9
71
48.4
22.6
0
71
65.3
47.4
17.9
0
65.3
63.2
46.1
17.1
0
63.2
60.3
43.9
16.4
0
60.3
57
41.1
15.9
0
57
54.5
38.1
16.4
0
54.5
49.7
34.1
15.6
0
49.7
45.4
31.2
14.2
0
45.4

Nivel global de zgomot al sursei la relantiu in punctulP2LA=65.2 dB (A)


Nivel global de zgomot de fond in punctul P2 LAF=85,4 dB (A)

/7

Dosar nr.

RAPORT TEHNIC
Laborator Acustica si Vibratii
Str. Atomistilor, nr 401, Magurele, Judet Ilfov
Telefon: 021-434.01.98/441, Fax: 021-434.02.41

Frecventa Hz
20 Hz
25 Hz
31.5 Hz
40 Hz
50 Hz
63 Hz
80 Hz
100 Hz
125 Hz
160 Hz
200 Hz
250 Hz
315 Hz
400 Hz
500 Hz
630 Hz
800 Hz
1 kHz
1.25 kHz
1.6 kHz
2 kHz
2.5 kHz
3.15 kHz
4 kHz
5 kHz
6.3 kHz
8 kHz
10 kHz
12.5 kHz
16 kHz

Nr. 1/ data 8.5.2014

Punctul 3 M19;M16
L
Lf
L-Lf
L
L-L
7.2
0.1
7.1
0.9
6.3
15.6
8.7
6.9
1
14.6
21.4
17.5
3.9
2.1
19.3
36.3
25.9
10.4
0
36.3
35.9
32.1
3.8
2.2
33.7
33.4
29.7
3.7
2.3
31.1
45.2
37.7
7.5
0.8
44.4
55.6
42.2
13.4
0
55.6
65.7
50
15.7
0
65.7
64.7
50.6
14.1
0
64.7
69.7
48.7
21
0
69.7
70.6
58.1
12.5
0
70.6
74.4
58.1
16.3
0
74.4
72.9
56
16.9
0
72.9
74.2
55.4
18.8
0
74.2
75.2
56.5
18.7
0
75.2
75.7
55.6
20.1
0
75.7
75.2
54.1
21.1
0
75.2
76.3
54.4
21.9
0
76.3
74
54
20
0
74
74.1
50.9
23.2
0
74.1
75.7
50
25.7
0
75.7
72.1
49.1
23
0
72.1
65.5
48.3
17.2
0
65.5
63.6
45.9
17.7
0
63.6
60.9
43.4
17.5
0
60.9
57.7
40.6
17.1
0
57.7
55.9
37.6
18.3
0
55.9
50.5
32.4
18.1
0
50.5
45.8
27
18.8
0
45.8

Nivel global de zgomot al sursei la relantiu in punctulP3 LA=66.4 dB (A)


Nivel global de zgomot de fond in punctul P3 LAF=85,6 dB (A)

/7

Dosar nr.

RAPORT TEHNIC
Laborator Acustica si Vibratii
Str. Atomistilor, nr 401, Magurele, Judet Ilfov
Telefon: 021-434.01.98/441, Fax: 021-434.02.41

Nr. 1/ data 8.5.2014

/7

Legenda:
LA - nivel global de zgomot ponderat A
Lech - nivel global de zgomot echivalent continuu
L - nivel de zgomot al sursei
LF - nivel de zgomot de fond
dL - corectia ce se aplica la nivelul de zgomot al sursei
L-dL - corectia aplicata la nivelul de zgomot al sursei
Incertitudinea de masurare: U=1.5%

Elaborat
Bacanu Alina
Marius Deaconu

RESPONSABIL INCERCARE,
Bacanu Alina

VERIFICAT,
Dr.Ing.Adina Ionescu

También podría gustarte