Está en la página 1de 4

CÁLCULO DE CAUDALES POR DPTO.

POT.
REND. ท
BLOQUE POT. ABS. P.C.S. CAUDAL[ CAUDAL
APARATO ÚTIL
NIVEL [kw] [kwh/m³] m³/h] TOTAL
[kw]
Planta Baja
Local Comercial 1 Calefactor 6.27 0.70 8.96 10.80 0.83
0.83

Local Comercial 2 Calefactor 4.07 0.70 5.81 10.80 0.54


0.54
Local Comercial 3 2 Horno 116.28 10.80 10.77
Calefon 23.00 0.70 32.86 10.80 3.04
13.81
Departamento 1 Termotanque 9.30 0.75 12.40 10.80 1.15
Caldera mural 23.14 0.70 33.06 9.72 3.40
Cocina - - 12.96 10.80 1.20
Secador (ropa) 5.00 10.80 0.46
6.21

Departamento 2 Termotanque 9.30 0.75 12.40 10.80 1.15


Caldera mural 23.14 0.70 33.06 9.72 3.40
Cocina - - 12.96 10.80 1.20
Secador (ropa) 5.00 10.80 0.46
6.21

Departamento 3 Termotanque 9.30 0.75 12.40 10.80 1.15


Caldera mural 23.14 0.70 33.06 9.72 3.40
Cocina - - 12.96 10.80 1.20
Secador (ropa) 5.00 10.80 0.46
6.21
CAUDAL TOTAL [m³/h] 33.81
Nivel Cantidad Caudal [m³/h] Total [m³/h]
Planta Baja 3 15.18
Primer piso 1 6.21 6.21
Segundo Piso 1 6.21 6.21
Tercer Piso 1 6.21 6.21
Caudal Total [m³/h] 33.81
Caudal Total [m³/h] Simultaneo 16.91
otal [m³/h]

Nivel Caudal [m³/h] Medidor


Planta Baja
Local comercial 1 0.83 BK-G 1,6
Local comercial 2 0.54 BK-G 1,6
Panaderia 13.81 Samgas. Italia.Modelo G10
Primer piso 6.21 Samgas. Italia.Modelo G6
Segundo Piso 6.21 Samgas. Italia.Modelo G6
Tercer Piso 6.21 Samgas. Italia.Modelo G6
Regulador Común