ANALISIS ESTRUCTURAL A&A Final
ANALISIS ESTRUCTURAL A&A Final
MEMORIA DE
CÁLCULO
ESTRUCTURAL
“EDIFICIO MULTIFAMILIAR”
Propietario : CONSTRUCTORA A&A SAC.
Departamento : La Libertad
Provincia : Trujillo
Año : 2019
Contenido
DPSTO. 1
DPSTO. 2
DPSTO. 3
04 09
B'
PROY.
PROY. DUCTO
DUCTO
BASURA
INST.-VENT.
01 02 03 04 05 06 07 08 09 10 11
10
11
SS.HH.
12
03 02 01
6.56M2.
A
A'
Junta Dilat. 4" Junta Dilat. 4"
DUCTO
SS.HH.
CLOSET
SS.HH.
SS.HH.
CLOSET
B B'
DUCTO
DUCTO
BASURA 22 21 20 19 10 09 08
I.M.
E.M.
01 02 03 04 05 06 07
DUCTO
02 01
PASADIZO
03
04
05
06
07
08
PASADIZO
SS.HH.
SS.HH.
CLOSET
SS.HH.
SS.HH.
PASADIZO
A'
Junta Dilat. 4" Junta Dilat. 4"
DUCTO
SS.HH.
CLOSET
SS.HH.
SS.HH.
CLOSET
B B'
DUCTO
DUCTO
BASURA 15 14 13 12 10 09 08
I.M.
E.M.
01 02 03 04 05 06 07
02
CLOSET
PASADIZO
03
SS.HH.
04
05
06
07
08
09
10
11
12 13 14
SS.HH.
DUCTO
SS.HH.
CLOSET
SS.HH.
SS.HH.
PASADIZO
BALCON
A
NORMAS A CONSIDERAR
-Reglamento Nacional de Edificaciones.
- Normas Peruanas de Estructuras:
. E.030 Sismo Resistente
. E.050 Suelos y Cimentaciones
. E.060 Concreto Armado
. Capítulo Peruano, Normas Técnicas Peruanas (INDECOPI), ITINTEC
- ACI 318-201
CRITERIOS DE PREDIMENCIONAMIENTO
Teniendo en cuenta las áreas tributarias, para el presente diseño se consideran los
tipos de : columnas : rectangulares de (.40mX.60m) ; Vigas Principales : (.40mx.60m),
(.40mx.55m); vigas secundarias de (.30mx.55m), (.15mx.45m) , (.25mx.20m) (.Vigas en
voladizo (.30mx.50m),(0.40mx0.20m) y Voladizo o de borde(.15mx.20m) ; Placas con
espesores variables de e=0.30m,e=0.20m, en Ascensor e=0.35m ;Altura de entrepiso
primer nivel :3.75m , resto de pisos :2.40m ,Df=3.00m;
Aligerados para todos los pisos E=0.20m
MODULO DE ELASTICIDAD
El módulo de Elasticidad del concreto,
Ec, se calcula usando la expresión de la
sección 8.5 del ACI 318 2011
𝐸𝐶=15100√𝑓𝑐′ [𝐾𝑔/𝑐𝑚2]
MODULO DE CORTE
El módulo de corte, Gc se calcula mediante
la siguiente relación y es determinada
por el ETABS
𝐺𝐶=𝐸2(𝑣+1) [𝐾𝑔𝑐𝑚2]
2. ESTRUCTURACION
Las columnas de soporte y zapatas corridas y que son de concreto armado
Se han considerado:
La resistencia del concreto para los elementos estructurales es de 280 Kg/cm².
El esfuerzo de fluencia de la barras de construcción es de Fy= 4200 kg/cm², estas
deben cumplir con las disposiciones de ASTM A 706M ó A 615M, grado 60.
Muros de Albañilería :Pe=1.8 tn/m3 ;E=500f´m(f´m de 55 a 65 k/cm2) ;U=0.25
Las dimensiones de los elementos estructurales, se han determinado mediante un
proceso iterativo proveyendo de rigidez y resistencia a la edificación.
3. CARGAS DE DISEÑO:
Las cargas de gravedad, permanente y variables se estimaran de acuerdo a lo estipulado
en la Norma Técnica de Edificación E-0.20 y la carga accidental (Sismo) de acuerdo a la
Norma Técnica de Edificación E-0.30.
a. Espesor de techo : e=0.20m
b. Peso de Techo : 300 k/m2
c. Piso terminado:100 k/m2
d. Tabiquería :100 k/m2
e. Sobrecarga : 200 k/m2
f. Sobrecarga :100 k/m2 (Azotea)
ESTUDIOS DE SITIO
Son estudios similares a los de microzonificación, aunque no necesariamente en toda su
extensión. Estos estudios están limitados al lugar del proyecto y suministran información
sobre la posible modificación de las acciones sísmicas y otros fenómenos naturales por las
condiciones locales. Su objetivo principal es determinar los parámetros de diseño.
Los estudios de sitio deberán realizarse, entre otros casos, en grandes complejos industriales,
industria de explosivos, productos químicos inflamables y contaminantes. No se considerarán
parámetros de diseño inferiores a los indicados en esta Norma.
Perfiles de Suelo
a. Perfil Tipo S0: Roca Dura
b. Perfil Tipo S1: Roca o Suelos Muy Rígidos(>5k/cm2)
c. Perfil Tipo S2: Suelos Intermedios (0.5 k/cm2 a 1 k/cm2)
d. Perfil Tipo S3: Suelos Blandos (0.25k/cm2 a 0.5 k/cm2)
e. Perfil Tipo S4: Condiciones Excepcionales (suelos excepcionalmente flexibles)
De acuerdo a las características de sitio, se define el factor de amplificación sísmica (C) por las
siguientes expresiones:
REGULARIDAD ESTRUCTURAL
5. COMBINACIONES DE CARGAS
Los elementos de concreto armado se dimensionaran según las especificaciones ACI
318-2014, método de diseño por factores de carga y resistencia. La resistencia
requerida, U, se obtiene multiplicando las cargas de servicio por factores de carga,
estas combinaciones cubren las diferentes posibilidades de ocurrencia simultánea
de las acciones, corrigen los errores que se cometen al modelar la estructura.
Dado que la carga sísmica se calcula en condiciones de resistencia, en las
combinaciones de carga en las que se incluya el sismo, se asignara uno como factor
de carga, ver Norma de Diseño Sismo Resistente vigente:
U1=1.4D
U2= 1.2D + 1.6L
U3 = 1.3D + L +S
U4= 1.3D + L -S
U5 = 0.8D +S
U6 = 0.8D -S
U7=1.3D+L+EQ
U8=0.8D+EQ
U=ENVOLVENTE=U1+U2+U3+U4+U5+U6+U7+U8
6.- METODOLOGIA DE ANALISIS ESTRUCTURAL
Según el Item 5.2 de la norma Técnica de Edificación E-030, donde nos indica los
máximos desplazamientos laterales permitidos de entrepiso.
Concreto Armado : 0.007 m.
*Del análisis dinámico se está cumpliendo con la Norma de Diseño Sísmico E.030
la cual nos indica que los tres primeros modos de vibración deben ser los periodos fundamentales
es decir, las direcciones principales "x" e "y" de traslación y "Z" de rotación.
= P = 0.3056
PARTICIPACIÓN DE MASAS
FUERZAS DE DISEÑO
TABLE: Story Forces
Load P VX VY T MX MY
Story Location
Case/Comb tonf tonf tonf tonf-m tonf-m tonf-m
Piso 1 EQ-XX Max Bottom 0 326.3423 180.3206 6039.7796 2485.762 4455.6215
Piso 1 EQ-YY Max Bottom 0 180.3206 384.0533 3465.8292 5351.737 2387.3681
Dir X
E.030 Diseño
Sismorresistente
746.46 Tn
671.80990 Tn No Cumple: Escalar
Factor de Escala X
= 2.0586051 X
1.9651
Escalamiento de Fuerzas
Factor de Escala Y
Factor de Escala
= 2.0586 = 1.7492622 Y
Ton 1.6698
Story1 Sismo X Bottom 0 2442.9452
Story1 EQ-XX Max Bottom 0 641.2953
Ton
Story1 Sismo X Bottom 0 2442.9452
Dir X
Story1 EQ-XX Max Bottom 0 641.2953 NO CUMPLE
DISTRIBUCIÓN DE FUERZAS
T=0.335s k= 1.00
Piso Pᵢ (hᵢ)ᴷ Pᵢ*(hᵢ)ᴷ αᵢ Piso αᵢ V Fᵢ Fi Acum (Tn)
8 26968.560 2.50 67421.400 0.021409
7 148709.260 2.50 371773.150 0.118054 8 0.021409 746.455 15.981 15.98
6 167264.260 2.50 418160.650 0.132784 7 0.118054 746.455 88.122 104.10
5 167264.260 2.50 418160.650 0.132784 6 0.132784 746.455 99.118 203.22
4 167264.260 2.50 418160.650 0.132784 5 0.132784 746.455 99.118 302.34
3 167264.260 2.50 418160.650 0.132784 4 0.132784 746.455 99.118 401.46
2 167264.260 2.50 418160.650 0.132784 3 0.132784 746.455 99.118 500.57
1 176906.580 3.50 619173.030 0.196615 2 0.132784 746.455 99.118 599.69
∑ 1188905.700 3149170.830 1.00 1 0.196615 746.455 146.764 746.46
En "X" En "Y"
Ia 0.90 Ia 0.90
Ip 0.75 Ip 0.75
Ro 6.00
Rx 4.05 Ry 4.05
Tp= 0.60
T= 0.335 ETABS
Factor de Zona: Zona 4 C= 2.50
TL Tp T C ZUCS/R Uso Import Edif: Vivienda
2.00 0.60 0.00 2.50 0.30555556 Coef. Ampl. Sis: Art. 2.5
2.00 0.60 0.20 2.50 0.30555556 Factor de Suelo: Suelo Interm.
2.00 0.60 0.40 2.50 0.30555556 Espectro de Respuesta Sísmica Factor de Zona Z 0.45 Tp 0.60
2.00 0.60 0.60 2.50 0.30555556 Uso Import Edif. U 1.00 TL 2.00
2.00 0.60 0.80 1.88 0.22916667 Especto de Respuesta Sísmica Coef. Ampl. Sis C 2.50 C/R≥ 0.110
2.00 0.60 1.00 1.50 0.18333333 Espectro Inelástico Tp=0.60 TL=2.00 Factor de Suelo S 1.10 C/R= 0.617
2.00 0.60 1.40 1.07 0.13095238 Factor de Reduc. Sis R 4.05 OK
2.00 0.60 1.80 0.83 0.10185185 0.330
2.00 0.60 2.20 0.62 0.07575758 0.300
2.00 0.60 2.60 0.44 0.05424063 0.270
0.240
2.00 0.60 3.00 0.33 0.04074074
0.210
2.00 0.60 3.50 0.24 0.02993197
Sa/g
0.180
2.00 0.60 4.00 0.19 0.02291667 0.150
2.00 0.60 4.50 0.15 0.01810700 0.120
2.00 0.60 5.00 0.12 0.01466667 0.090
2.00 0.60 6.00 0.08 0.01018519 0.060
0.030
2.00 0.60 7.00 0.06 0.00748299
0.000
2.00 0.60 8.00 0.05 0.00572917 0.00 2.00 4.00 6.00 8.00 10.00 12.00
2.00 0.60 9.00 0.04 0.00452675 Periodo, T(s)
2.00 0.60 10.00 0.03 0.00366667
= 0.305556
CÁLCULO DE DERIVAS
Story MAX/AVG DISPLACEMENTS Sismo "X" + Exc 5% Derivas NTP-E.030
Sismo "X" + Exc 5%
Desplazamiento Derivas
LOAD CASE Desplaz. Derivas Derivas Derivas Derivas
STORY DIRECTION X Desplazamiento Piso Altura (m) %∆inelástic
∆ Límite
COMBO (mm) ∆elástica ∆inelástica
a % ∆ Límite
(mm) Y
Story8 Sismo X X 13.156 4.937 8 2.50 Story8 21.00 13.156 0.000552 0.0018989 0.190 0.007 0.70
Story7 Sismo X X 11.777 4.039 7 2.50 Story7 18.50 11.777 0.000641 0.0022060 0.221 0.007 0.70
Story6 Sismo X X 10.175 3.559 6 2.50 Story6 16.00 10.175 0.000706 0.0024304 0.243 0.007 0.70
Story5 Sismo X X 8.41 3.001 5 2.50 Story5 13.50 8.410 0.000748 0.0025750 0.257 0.007 0.70
Story4 Sismo X X 6.54 2.384 4 2.50 Story4 11.00 6.540 0.000761 0.0026204 0.262 0.007 0.70
Story3 Sismo X X 4.637 1.731 3 2.50 Story3 8.50 4.637 0.000726 0.0024993 0.250 0.007 0.70
Story2 Sismo X X 2.822 1.084 2 2.50 Story2 6.00 2.822 0.000626 0.0021550 0.216 0.007 0.70
Story1 Sismo X X 1.257 0.5 1 3.50 Story1 3.50 1.257 0.000359 0.0012363 0.124 0.007 0.70
0 0.00 0 0.000 0.00 0.00 0.00 0.007
Dmá x= 0.2177 OK
7 6
6 5 Deriva Elástica E.030
Pisos
5
Pisos
4
4 Desplazamiento X Deriva Inelástica E.030
3
3 Desplazamiento Y
2 Deriva Límite
2
1 1
0 0
0.00 5.00 10.00 15.00 0.000 0.001 0.002 0.003 0.004 0.005 0.006 0.007 0.008
Desplazamiento (mm) Derivas X
9
Sismo Y+EccX
8
9
8 7
7 6
6 5
Pisos
Deriva Elástica E.030
5
Pisos
4
Deriva Inelástica E.030
4 Desplazamiento X
3 Deriva Límite
3 Desplazamiento Y
2
2
1 1
0 0
0.000 5.000 10.000 15.000 0.000 0.001 0.002 0.003 0.004 0.005 0.006 0.007 0.008
Desplazamiento (mm) Derivas Y
EXCENTRICIDAD ACCIDENTAL
Se ha considerado en ambos sentidos como 0.05 veces la dimensión del edificio en la dirección
perpendicular al análisis.
La fuerza sísmica vertical se ha considerado como una fracción del peso igual a 2/3 Z.U.S
El periodo fundamental de la estructura es menor al periodo del suelo donde se apoyara al estructura
;por lo que los efectos sísmicos vibratorios no se multiplicaran en caso de sismo.
DIAGRAMAS DE MODULO A
DIAGRAMAS
MOMENTOS FLECTORES PLANTA
TODAS LAS COLUMNAS han tomado el acero mínimo que es 24 cm2 ejemplo de diseño:
ACERO VIGAS
ACERO EN PLACAS
10.30
2.00
.30
PLACA 01
2.92
0.60
.35
2.85
.35
2.62
PLACA 02
3.32
0.60
.30
4.60
0.60
.30
PLACA 03
7.69
1.20 1.20
.30
PLACA 04
6.73
1.60
.30
1.95
.17
PLACA 05
6.73
1.20
2.00
.30
.20
PLACA 06
MEDIDAS b h Pe P
PESOS (m) (m) (t/m2) (Tn/m2)
PESO PROPIO 1.0 0.30 0.30
PISO TERMINADO 1.0 0.10 0.10
TABIQUERIA 1.0 0.10 0.10
ACABADOS 1.0 0.05 0.05
D 0.55
0.22
MEDIDAS b h Pe P
PESOS (m) (m) (t/m2) (Tn/m2)
S/C 1.0 0.20 0.20
D 0.20
0.08
Wu=1.5D+1.8L
Carga muerta
Carga viva
DMF
DFC
DEFOMADA
ACERO
LOSA ALIGERADA
DATOS DE VIGUETA :
f'c(k/cm2)= 280.00 ρ max(0.50 o 0.75)= 0.50
fy(k/cm2)= 4200.00 Factor de Seguridad= 0.50
ρ min= 0.0012 para losas RNE-060(10.5.4) A rea d e A cero ( cm2 )
As(min)
ELEM ENTO Mu(t.m) b(cm) d(cm) ρ max Mur (t.m) TIPOD E D ISEÑO A w ρ Mu( rem) d'(cm) As1(cm2) As(cm2) As'(cm2)
cm2
M(+)1 1.34 40.00 17.50 0.0144 5.80 DISEÑO A 0.84 0.04 0.04 0.0030 ------ 5.00 ------- 2.08 -----
TRACCION
DISEÑO A
M(+)2 0.36 40.00 17.50 0.0144 5.80 0.84 0.01 0.01 0.0008 ------ 5.00 ------- 0.84 -----
TRACCION
DISEÑO A
M(-)4 1.88 10.00 17.50 0.0144 1.45 TRACCION Y 0.21 0.06 0.06 0.0039 0.43 5.00 0.67 3.19 0.90
COM PRESION
DISEÑO A
M(-)5 0.55 10.00 17.50 0.0144 1.45 0.21 0.07 0.07 0.0050 ------ 5.00 ------- 0.87 -----
TRACCION
𝜎 𝜎 − ℎ𝑓 ɣ − /𝐶
CIMENTACIÓN :
Peso propio
Carga viva
Punzonamiento <1…ok
Combinaciones de carga
CONCLUSIONES
RECOMENDACIONES