Mensaje Se aprueba Submital pero se aclara que el modelo colocado en el título de este no es el correcto, el correcto sería el modelo
OAH015GDAM, tal como lo indica la ficha adjunta en su pagina 28. SE REALIZO EL CAMBIO DEL NOMBRE DEL MODELO
EN SUBMITTAL
Gerardo Zenon (GRUPO-SACMAG) Approved Se aprueba Submital pero se aclara que el modelo
colocado en el título de este no es el correcto, el
correcto sería el modelo OAH015GDAM, tal como
lo indica la ficha adjunta en su pagina 28.
Persona
Responsable
Distribución Felipe Velasquez (BCQS), Daniel Talero (BCQS), Javier Soria Pérez (KVO), Javier Soria (KVO), Diego Pinilla (BCQS), Adriana
López Urzúa (ALPHA HARDIN), Jorge Arturo Gasca Gasca (ALPHA HARDIN), Joel Flores Gregorio (KVO), Leonardo Díaz
(ALPHA HARDIN), Jose Manuel Cruz Villareal (ALPHA HARDIN), Jorge Luis Caridad Lugo (KVO)
Comentarios Se aprueba Submital pero se aclara que el modelo colocado en el título de este no es el correcto, el correcto sería el
modelo OAH015GDAM, tal como lo indica la ficha adjunta en su pagina 28.
Prepared for
Prepared by
Unit Overview
Supply
Model Number Air Volume Static Pressure External Dimensions
cfm External Total Height Width Length
inWc inWc in in in
OAH032GDAM 14909 0.70 2.27 66* 92* 120
*Not including base rails, coil connectors, drain connectors, vestibule sections, control boxes and hoods.
Unit
Model Number: OAH032GDAM
Approval: ETL Listed / ETL Listed to Canadian Safety Standards (ETL Label / ETLc Label)
Outer Panel: Painted 24 gauge G60 Galvanized Steel
Liner: 24 gauge Galvanized Steel (unless noted per section)
Insulation: R-13 Injected Foam
Unit Configuration: Inline horizontal Drive (Handling) Location: Right
Base: Curb ready Wall Thickness: 2 in
Roof Curb Kit: 0 in Shipping Stretch Wrap: Yes
Altitude: 33 ft Parts Warranty: Standard One Year
20 16 28 56
1 2
PLENUM
PBFILT
DXC
FAN
66
66
Z
X
64 56
Elevation View
NOTE: Special components aren't included in the corner weights and center of gravity data.
Dimensions provided as a courtesy and are recommended minimums only. Daikin is not responsible for supplying or designing drain pan traps and is not responsible
for any damage caused by incorrect trap heights. The dimensions listed above should be reviewed and approved by a licensed plumbing professional.
Notes
Standard
1. As a standalone component, unit meets or exceeds requirements of ASHRAE 90.1 - 2007. The approving authority is responsible
for compliance of multi - component building systems.
Unit Overview
Supply
Model Number Air Volume Static Pressure External Dimensions
cfm External Total Height Width Length
inWc inWc in in in
OAH005GDAM 1937 0.35 2.28 32* 42* 98
*Not including base rails, coil connectors, drain connectors, vestibule sections, control boxes and hoods.
Unit
Model Number: OAH005GDAM
Approval: ETL Listed / ETL Listed to Canadian Safety Standards (ETL Label / ETLc Label)
Outer Panel: Painted 24 gauge G60 Galvanized Steel
Liner: 24 gauge Galvanized Steel (unless noted per section)
Insulation: R-13 Injected Foam
Unit Configuration: Inline horizontal Drive (Handling) Location: Right
Base: Curb ready Wall Thickness: 2 in
Roof Curb Kit: 0 in Shipping Stretch Wrap: Yes
Altitude: 33 ft Parts Warranty: Standard One Year
20 14 32 32
1
PFILT
DXC
FAN
MIX
32
32
Z
X
98
Elevation View
NOTE: Special components aren't included in the corner weights and center of gravity data.
Dimensions provided as a courtesy and are recommended minimums only. Daikin is not responsible for supplying or designing drain pan traps and is not responsible
for any damage caused by incorrect trap heights. The dimensions listed above should be reviewed and approved by a licensed plumbing professional.
AHRI Certification
Certified in accordance with the AHRI Central Station Air-Handling Unit Certification Program, which is based on
AHRI Standards 430/431. Certified units may be found in the AHRI Directory at www.ahridirectory.org.
Unit Overview
Supply
Model Number Air Volume Static Pressure External Dimensions
cfm External Total Height Width Length
inWc inWc in in in
OAH015GDAM 6758 0.35 1.82 44* 74* 110
*Not including base rails, coil connectors, drain connectors, vestibule sections, control boxes and hoods.
Unit
Model Number: OAH015GDAM
Approval: ETL Listed / ETL Listed to Canadian Safety Standards (ETL Label / ETLc Label)
Outer Panel: Painted 24 gauge G60 Galvanized Steel
Liner: 24 gauge Galvanized Steel (unless noted per section)
Insulation: R-13 Injected Foam
Unit Configuration: Inline horizontal Drive (Handling) Location: Right
Base: Curb ready Wall Thickness: 2 in
Roof Curb Kit: 0 in Shipping Stretch Wrap: Yes
Altitude: 33 ft Parts Warranty: Standard One Year
20 16 28 46
1
PLENUM
PBFILT
DXC
FAN
44
44
Z
X
110
Elevation View
NOTE: Special components aren't included in the corner weights and center of gravity data.
Dimensions provided as a courtesy and are recommended minimums only. Daikin is not responsible for supplying or designing drain pan traps and is not responsible
for any damage caused by incorrect trap heights. The dimensions listed above should be reviewed and approved by a licensed plumbing professional.
AHRI Certification
Certified in accordance with the AHRI Central Station Air-Handling Unit Certification Program, which is based on
AHRI Standards 430/431. Certified units may be found in the AHRI Directory at www.ahridirectory.org.