Documentos de Académico
Documentos de Profesional
Documentos de Cultura
00
NOTAS
3.00
PERCOLADOR 1 PERCOLADOR 2 PERCOLADOR 3 GRAVEDAD.
5. LAS TAPAS DE LAS CAJAS DE REGISTRO SERÁN DEL MISMO MATE- RIAL QUE DEL PISO
ESPECIFICACIONES TÉCNICAS
TANQUE SEPTICO POZOS DE INFILTRACIÓN
3.00
CILINDRO, EXCLUYENDO EL FONDO. PARA EL CÁLCULO SE CONSIDERARÁ EL Ø EXTERIOR
FILTRANTE; SIEMPRE Y CUANDO EL FONDO DEL POZO QUEDE A 2.00m POR ENCIMA DEL
4.40
MINIMO 6.00m
NIVEL FREÁTICO. SIN EMBARGO, SI LA TASA DE INFILTRACION SE HA DETERMINADO EN
EPOCA DE LLUVIAS (CONDICIONES MAS DESFAVORABLES) EL FONDO DEL POZO PUEDE
.15
1.00
4.00
DISTRIBUCION
.40
2.00
1.00
4. EL FONDO DEL POZO ESTARÁ CUBIERTO POR UNA CAPA DE 0.60m DE GRAVA DE Ø 2.5 A
5.0 cm.
2.50
5.60
2.75
32.62
3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00
518
1 Ø 3/8" 1 Ø 3/8"
@ 0.25 m. @ 0.25 m.
Rejilla Fº Ø1/2"
@ 40 mm TERRE
NO NA
.47
.50
1 Ø 3/8" TURAL
1 Ø 3/8"
@ 0.20 m. @ 0.25 m.
.15
NIVEL DE LIQUIDO
.15
1 Ø 3/8" 1 Ø 3/8"
@ 0.20 m. @ 0.25 m.
1.00
INGRESO Ø 4"
516 .15
CRIBADO .15
.05
TANQUE SEPTICO CAJA DE
02 CAMARAS DISTRIBUCION
POZO
514 PERCOLADOR
PLANO:
PTAR PLANTA Y PERFIL
TS-PP-01
DEPARTAMENTO: PROVINCIA: DISTRITO: CASERIO: LAMINA:
CAJAMARCA SAN MIGUEL TONGOD SANTA ANA
PROYECTISTA: ENERO
DIBUJO: JFVC FECHA: ESCALA: INDICADA
Rodi Alejandro Urbina Diaz 2017
5.60 DETALLE TAPA DE INSPECCION DETALLE TIPICO
.20 3.00 .20 2.00 .20 DE TANQUE SEPTICO ABRAZADERA PARA
TUBERIAS DE VENTILACION
ESCALA 1/20
L
S/E
.20
.20
G Ø DE TUBERIA
.12
PERNO 3/8"
.50
F F CORTE F-F
.70
.12
.06
.05 .05
G .70
MURO
.50 CORTE G-G
PLANTA
4.00
4.00
4.40
Y TAPA TAPA Y CORONACION
f'c=175 kg/cm2
.10
.10
MALLA fe Ø 3/8"
CORONACION
.10
TARRAJEADO Y PULIDO
(FONDO, LATERALES
Y MEDIA CAÑAS) MURO DE
.30
CONCRETO F'c=175 kg/cm2
1.00
INGRESO Ø 4"
.05
1.00
PANTALLA
X X
.05
1.25
1.25
PANTALLA
1.00
.40
RANURA
.10 .50
SALIDA Ø 2" SALIDA Ø 2"
SALIDA Ø 2"
.15
.15
1.00
.10 .80 .10 .10 .80 .10
.20
ESCALA 1/20 ESCALA 1/20 ESCALA 1/20
4" 4"
.30
INSERTO DE
4.40 VACIADO
Ø
.20 4.00 .20 EMPAQUETADURA
DE JEBE
4"
.30 .12
.30 .12
.30
.30
4"
.05
ES
.30
.30
P
.40
.40
ES
OR
DE
MU
TEE 6"PVC .25 RO
As HORIZONTAL MURO TEE 4"PVC
Ø1/2"@0.20M. TEE 4"PVC
TUBO PVC
4"
2.37
2.37
1.80
1.80
DETALLE TIPICO
DE ROMPEAGUA
As VERTICAL MURO
Ø1/2"@0.20M. SIN/ESCALA
S = 2%
S = 2%
.15
.15
1 Ø 3/8" 1 Ø 3/8"
.20 3.00 @ 0.20 m. .20 2.00 .20 .15 .20 @ 0.20 m. 4.00 .20
5.90 4.70
.15 .15 .15
CORTE A - A CORTE B - B
PROYECTO:
"MEJORAMIENTO Y AMPLIACIÓN DEL SISTEMA DE AGUA POTABLE Y SANEAMIENTO DEL
CASERIO SANTA ANA, DISTRITO DE TONGOD, SAN MIGUEL - CAJAMARCA "
PLANO:
TANQUE SÉPTICO
TS-01
DEPARTAMENTO: PROVINCIA: DISTRITO: CASERIO: LAMINA:
CAJAMARCA SAN MIGUEL TONGOD SANTA ANA
PROYECTISTA: ENERO
DIBUJO: JFVC FECHA: ESCALA: INDICADA
Rodi Alejandro Urbina Diaz 2017