ALTRONIC DE-3000 Controller SYSTEM

User: sfernan01

Delay
Channel User Label Class Device Type
Time

01 SUCTION 0 - 300 PSIG


02 NOT USED A 000 sec. -
03 DISCH 1 ET 0 - 1000 PSIG
04 DISCH 2 ET 0 - 2000 PSIG
05 PR DIF 030A +0000. - +0100. mH2O
06 COMP OIL 0 - 300 PSIG
07 PRELUBE FAIL B 030 sec. N/C SWITCH
08 SCRUBBER 1 LSHH 1500 A 000 sec. N/C SWITCH
09 SCRUBBER 2 LSHH 1501 A 000 sec. N/C SWITCH
10 FUEL SCRBR LSHH 3048 A 000 sec. N/C SWITCH
11 ENG OIL LSLL 2023 A 000 sec. N/C SWITCH
12 COMP OIL LSLL 2022 A 000 sec. N/C SWITCH
13 JCKT WTR LSLL 4100 A 000 sec. N/C SWITCH
14 AUX WTR LSLL 4101 A 000 sec. N/C SWITCH
15 ENG VSHH 8151 A 000 sec. N/C SWITCH
16 COMP VSHH 8252 A 000 sec. N/C SWITCH
17 COOLER FAN VSHH 8350 A 000 sec. N/C SWITCH
18 DSCH CYL1 K - TC ßF
19 DSCH CYL 2 K - TC ßF
20 DSCH CYL 3 K - TC ßF
21 DSCH CYL 4 K - TC ßF
22 PRE CONV K - TC ßF
23 POST CONV K - TC ßF
24 LSH030A A 000 sec. N/C SWITCH
25 AUX WTR K - TC ßF
26 COMP OIL K - TC ßF
27 NO FLOW LUBR B 240 sec. N/C SWITCH
28 LSH031A A 000 sec. N/C SWITCH
29 ESM FAIL A 000 sec. N/C SWITCH
30 PANEL E-STOP A 000 sec. N/C SWITCH
S01 SPEED #1 RPM
A01 A01 %
A02 A02

Page 1
ALTRONIC DE-3000 Controller SYSTEM
User: sfernan01

Low SS Low SS High SS High SS Low AC Low Analog High AC High Analog
Channel DIFF
Setpoint Class/Time Setpoint Class/Time Setpoint Output Selection Setpoint Output Selection

01 +066.1 C 010 +148.0 A 000 +070.0 No 6 +165.0 6


03 +0300. C 010 +0410. A 000 +0275. No 6 +0375. 6
04 +0660. C 010 +0810. A 000 +0685. No 6 +0910. 6
05 +0000. C 010 +0063. A 000 +0000. No +0063.
06 +045.0 B 135 +090.0 A 000 +050.0 No 6 +010.0 4
18 -0076. A 000 +0275. A 000 -0076. No +0280. 6
19 -0076. A 000 +0260. A 000 -0076. No +0305. 6
20 -0076. A 000 +0275. A 000 -0076. No +0280. 6
21 -0076. A 000 +0260. A 000 -0076. No +0305. 6
22 -0076. A 000 +1000. A 000 -0076. No +1472.
23 -0076. A 000 +0500. A 000 -0076. No +1472.
25 -0076. A 000 +0175. A 000 -0076. No +1472.
26 +0032. A 000 +0190. A 000 +0069. No 3 +0180. 6
S01 +0050. C 010 +1250. A 000 +0200. 1 +2500.
A01 +0000. +0100.
A02 +0000. +0100.

Page 2
ALTRONIC DE-3000 Controller SYSTEM
User: sfernan01

Test Class C Output 1 Output 2


Tim er(sec) Tim er (min) Selections Selections
100 010 NS / N NS / N
000 sec. 005 sec.
STOP STOP
OEM Eng Ctrl Enabled Prelube Time= 0150 Sec Pre Lube Disc. RPM = 0300 RPM Post Lube Time= 0000 Sec
Start Sig Delay= 0030 Sec Start Sig ON Time= 0002 Sec Start Sig ON @ Stop= 0000 Sec Aux Delay= 0000 Sec
Aux ON @ Stop= 0000 Sec DER Delay= 0000 Sec DER ON @ Stop= 0000 Sec
--------------------------------------------------
--------------------------------------------------
--------------------------------------------------
--------------------------------------------------
Date Tim e DE-3000 Node #
02/20/2021 12:13:49 001
--------------------------------------------------
--------------------------------------------------
--------------------------------------------------
--------------------------------------------------
Data Logging Settings:
Datalog Heading= L7044GSI ESM2 4 THROW 2 STGInterval= 005 Minutes.

Continue Data Logging Erase ALL Data Logs


after a Shutdown?= NO on Power-Up?= NO
--------------------------------------------------
--------------------------------------------------
--------------------------------------------------
--------------------------------------------------
--------------------------------------------------
--------------------------------------------------
--------------------------------------------------
--------------------------------------------------
***TERMINAL BO ARD #1*** 30 inputs/8 outputs

Capacity Output Control Primary Channel= 03 Cycle Time Delay= 010 Setpoint Deadband= +0001.
Proportional Band= 060 Control Setpoint= +0020. Max Digital Pulse= 1000 mS. Warmup Dela y= 00
Input Channel vs Loading= Direct
--------------------------------------------------
--------------------------------------------------
--------------------------------------------------
--------------------------------------------------
RPM Output Control: Pulses per Rev.= 208 Crank Disconnect= 0300

--------------------------------------------------
--------------------------------------------------
--------------------------------------------------
--------------------------------------------------
PID Control #1 PID Control #2 Cascade Control #2 (Used)Lin/Ramp Control #2
P= 050 P= 110 Gov RPM@ 4mA.= 0800 Setpoint 1= +020.0
I= 020 I= 025 Gov RPM@ 20mA.= 1400 Current @ Set 1= 04.0mA
D= 999 D= 999 Eng. Idle RPM= 0800 Setpoint 2= +050.0
PID Chan= 01 PID Chan= 02 Min Eng. RPM= 1000 Current @ Set 2= 20.0mA
Deadband= +000.0 Deadband= +003.0 Max Eng. RPM= 1400 Current @ Stop= Disabled
Control SP.= +072.0 Control SP= +062.5 RPM Change/Cycle= 0050 Control Permissive= Ch 26
PID Control= Inverse PID Control= Inverse Cascade Control= Direct
Forced Dec Error=0005.00% Forced Dec Error=0005.00%
Forced Inc Error=0005.00% Forced Inc Error=0005.00%
Stop/Fault current=Disabled Stop/Fault current= Disabled

--------------------------------------------------
--------------------------------------------------
--------------------------------------------------
--------------------------------------------------
Output Selections:
Output #1 & #2 = On/Off Control
Output #6 = True
Output #7 = False
Output #8 = True
Output #5 = True
--------------------------------------------------
--------------------------------------------------
--------------------------------------------------
--------------------------------------------------
Unload Time = 0010 sec.
--------------------------------------------------
--------------------------------------------------
--------------------------------------------------
--------------------------------------------------
--------------------------------------------------
--------------------------------------------------
--------------------------------------------------
--------------------------------------------------

Hour/Service Meter Label Hours


Hourmeter RUN TIME HOURS 00000
Servicemeter 1 NOT USED -0000
Servicemeter 2 NOT USED -0000

Page 3
ALTRONIC DE-3000 Controller SYSTEM
User: sfernan01

Servicemeter 3 NOT USED -0000


Servicemeter 4 NOT USED -0000
Servicemeter 5 NOT USED -0000
Servicemeter 6 NOT USED -0000
Servicemeter 7 NOT USED -0000
Servicemeter 8 NOT USED -0000
Servicemeter 9 NOT USED -0000
Servicemeter 10 NOT USED -0000
Servicemeter 11 NOT USED -0000
--------------------------------------------------
--------------------------------------------------
--------------------------------------------------
--------------------------------------------------
End of Report