Está en la página 1de 1

A B C D E F G H I J

1 220V, 3Ø, 60 Hz 1
TD ADOSADO / 48 POLOS

TABLERO DE DISTRIBUCION DE OBRA -----

2x20A 30mA
C.1 2-1x4mm2 LSOH-80 + 1x2.5mm2/T
s TOMA INDUSTRIAL 2P 16A (T1)
2x25A

2 2x20A 30mA 2
C.2 2-1x4mm2 LSOH-80 + 1x2.5mm2/T
s TOMA INDUSTRIAL 2P 16A (T2)
2x25A
2x20A 30mA
C.3 2-1x4mm2 LSOH-80 + 1x2.5mm2/T
s TOMA INDUSTRIAL 2P 16A (T3)
2x25A
2x20A 30mA
C.4 2-1x4mm2 LSOH-80 + 1x2.5mm2/T
s TOMA INDUSTRIAL 2P 16A (T4)
2x25A
2x20A 30mA
C.5 2-1x4mm2 LSOH-80 + 1x2.5mm2/T
s TOMA INDUSTRIAL 2P 16A (T5)
3 2x25A 3
2x20A 30mA
C.6 2-1x4mm2 LSOH-80 + 1x2.5mm2/T
s TOMA INDUSTRIAL 2P 16A (T6)
2x25A
VIENE DE SUMINISTRO ELECTRICO
3x63A 2x20A 30mA
3-1x16mm2 N2XOH + 1x6mm2/T C.7 2-1x4mm2 LSOH-80 + 1x2.5mm2/T
s TOMA INDUSTRIAL 2P 16A (T7)
TUB. 35mmØ PVC-P 2x25A
2x20A 30mA
C.8 2-1x4mm2 LSOH-80 + 1x2.5mm2/T
s TOMA INDUSTRIAL 2P 16A (T8)
2x25A

4 2x20A 30mA 4
C.9 2-1x4mm2 LSOH-80 + 1x2.5mm2/T
s TOMA INDUSTRIAL 2P 16A (T9)
2x25A
2x20A 30mA
C.10 2-1x4mm2 LSOH-80 + 1x2.5mm2/T
s TOMA INDUSTRIAL 2P 16A (T10)
2x25A
220V, 3Ø, 60 Hz

C.11
ESPACIO DE RESERVA

C.12
ESPACIO DE RESERVA
5 5

BARRA DE TIERRA

INT. PRINCIPAL : CAJA MOLDEADA, 10kA


INT. DERIVADOS : PODER RUPTURA 10kA
SEGUN NORMA IEC 60898-1
6 6

04 DATOS GENERALES PROCEDIMIENTO DE APROBACION CLIENTE PROYECTO :


TIPO ADOSADO RESPONSABLE FIRMA FECHA EDIFICIO AUDACITY
03 DIMENSIONES 1050x500x200 DISEÑO M. VALENTIN M.V. 24/08/22 N° DE PLANO
02 IP 55 DIBUJO M. VALENTIN M.V. 24/08/22 VYV BRAVO TITULO : 2
CANTIDAD 01 REVISO A. LEZAMA A.L. 24/08/22 TABLERO DE DISTRIBUCION DE OBRA TD-1
01 DIAGRAMA UNIFILAR HOJA: 02 DE 02
ACABADO RAL 7035 APROBO C. MORILLO C.M. 24/08/22
Nº.REV. REVISIONES MATERIAL F°G° 1.5mm VEND. C. MORILLO C.M. 24/08/22 ESCALA: 1/10 FORMATO: A4 N.COTIZ.: 21344-24-01 CAD: