Documentos de Académico
Documentos de Profesional
Documentos de Cultura
ZONA 4
CATEGORIA C
SUELO S1
T_P
0.4
T_L 2.5
T 0.393
R_O 8 PORTICOS
I_p 0.75
I_a 1
REGULAR? NO
R 8
Z 0.45
U 1
C 2.500
S 1
R 6 PORTICOS
C/R 0.417 OK
ZUCS/R 0.188 0.188
K 1 OK
PISO 3 27.6274
PISO 2 52.9576 GRÁFICO DE FUERZAS EN LA BASE
PISO 1 69.0254
27.63 Tn
25.33 Tn 27.63 Tn
16.07 Tn 52.96 Tn
69.03 Tn
Fuerzas laterales por piso Fuerzas Cortantes por piso
Y
ZONA 4
CATEGORIA C
SUELO S1
T_P
0.4
T_L 2.5
T 0.341
R_O 8 PORTICOS
I_p 0.75
I_a 1
REGULAR? NO
R 8
Z 0.45
U 1
C 2.500
S 1
R 6 PORTICOS
C/R 0.417 OK
ZUCS/R 0.188 0.188
K 1 OK
PISOS MASA H
PISO 3 97.7941 9.7
PISO 2 127.9013 6.8
PISO 1 141.4609 3.9
Peso Sísmico 367.1563 SUM Pi*hi^k
47475
V estatico X-X
V estatico Y 69.0254
Y Mode
Period
sec
1 0.393
2 0.341
3 0.235
4 0.132
5 0.111
6 0.09
7 0.072
8 0.061
9 0.051
Pi*hi^k 𝛼𝑖 Fi Vi
948.6026 0.4002 27.6274 27.6274
869.7291 0.3670 25.3302 25.3302
551.6974 0.2328 16.0678 16.0678
2370.0290 1.0000 69.0254
Tn 9774
Tn
1 A S0
2 B S1
3 C S2
4 D S3
S0 S1 S2 S3
4 0.8 1 1.05 1.1
3 0.8 1 1.15 1.2
2 0.8 1 1.2 1.4
1 0.8 1 1.6 2
Método de Fuerzas Estáticas Equivalentes (Análisis Estático)
Factor
Zona 4 Z= 0.45
Categoría C: Comunes U= 1
Tipo de suelo S1: Roca o muy rígido S= 1
Sistema Estructural 4: Pórticos (Concr) R0= 8
Regularidad I: Irregular IP= 0.75
Element. Resistentes 1: Sólo pórticos R= 6
Ct= 35
Nº pisos 3 TP= 0.4
TL= 2.5
Cálculo de Masas
Periodo T= 0.39 s
Ordenada espectral C= 2.50
Coeficiente sísmico CS= 0.19 ZUCS/R
Aceleración espectral Sa= 1.84 m/s2
Cortante Basal V= 69.03 Ton
Estático)
UX UY UZ
Story
tonf-s²/m tonf-s²/m tonf-s²/m
PISO 3 9.9722 9.9722 0
PISO 2 13.0422 13.0422 0
PISO 1 14.4249 14.4249 0
Base 1.6320 1.6320 0
UX UY UZ
Story
tonf tonf tonf
PISO 3 97.7941 97.7941 0
PISO 2 127.9013 127.9013 0
PISO 1 141.4609 141.4609 0
367.1563 367.1563
ANALISIS ESTATICO
Eccentricity Ecc.
Load Pattern Type Direction Top Story
% Overridden
SISMO EST X Seismic X + Ecc. Y 5 False PISO 3
SISMO EST Y Seismic Y + Ecc. X 5 False PISO 3
ANALISIS DINAMICO
Load
Story Case/Comb Location P VX VY
o
kgf kgf kgf
SISMO X-X
PISO 1 Bottom 0 51839.19 21032.21
Max
SISMO Y-Y
PISO 1 Bottom 0 21032.21 44060.75
Max
Load
Story Case/Comb Location P VX VY
o
tonf tonf tonf
SISMO X-X
PISO 1 Max Bottom 0 51.8392 21.0322
SISMO Y-Y
PISO 1 Bottom 0 21.0322 44.0608
Max
m/s2
T MX MY
kgf-m kgf-m kgf-m
518629.41 148570.23 368506.76
T MX MY
tonf-m tonf-m tonf-m
518.6294 148.5702 368.5068
Cstegoria: A Z= 0.45
Zona: 4 U= 1
Suelo: S3 S= 1
Sistema Estrutural: Dual Tp= 0.4
Edificación: Regular R= 6
CONTROL DE DERIVAS
4
3
Piso
DERIVA
0.153 0.700 OK
0.232 0.700 OK
0.259 0.700 OK
0 0.7
CONTROL DE DERIVAS
4
3
Piso
DERIVA
E
SISMO Y-Y
DERIVA DERIVA
DERIVA LIMITE VERIFICACIO
INELASTICA INELASTICA
∆elastica ∆limite N
∆inelastica ∆inelastica (%)