punto tramo DISTANCIA POTENCIA VOLTAJE CORRIENTE F.P.

M WATTS VOLTS AMP. 0.9


1 C-C-1 18 39.6 127 0.3118 0.9
2 1 -- 2 3 29.7 126.948012 0.23395404 0.9
3 2 -- 3 2.8 19.8 126.94151 0.15597735 0.9
4 3 -- 4 2 9.9 126.937465 0.07799116 0.9
5 4 -- 5 2.75 6.6 126.93602 0.0519947 0.9
R= XL=
CAIDA DE CAIDA DE
CAL. COND VOLTAJE RESISTENCIA REACTANCIA VOLTAJE VOLTAJE
AWG NUEVO volts %
10 127 10.2 0.19 0.05198849 0.04093582
10 126.948012 10.2 0.19 0.00650122 0.00511907
10 126.94151 10.2 0.19 0.00404541 0.00318536
10 126.937465 10.2 0.19 0.00144484 0.00113767
10 126.93602 10.2 0.19 0.00132445 0.00104287
0.06530442 0.0514208
INTENSIDAD DE
CORREINTE
CARGAS CANTIDAD POTENCIA VOLTAJE ELECTRICA HORAS DE
AREA ELECTRICAS DE EQUIPOS (WATTS) (VOLTS) (AMPERES) USO DIARIO KWH/DIA

ESTETICA ILUM 2 11 127 1.0 3 0.066


MAQUINAS DE
PELO 3 12 120 1.0 7 0.252
SECADORA 2 1875 125 15.9 7 26.25
PLANCHA 2 1600 230 7.9 2 6.4
TELEVISION 1 90 110 1.7 2 0.18
BOCINA 1 150 200 1.7 2 0.3
MINI BOILER
ELECTRICO 1 3000 110 28.2 3 9
VENTILADOR
SALA DE TECHO 1 60.5 120 1.4 24 1.452
TELEVISION 1 55 240 1.1 4 0.22
COMEDOR ILUM 1 11 127 1.0 4 0.044
COCINA ILUM 1 11 127 1.0 5 0.055
MICRONDAS 1 1200 240 5.9 3 3.6
REFRIGERAD 1 400 127 4.0 6 2.4
CAFETERA 1 900 120 8.4 1 0.9
CAMPANA 1 160 120 2.2 1 0.16
LICUADORA 1 450 120 4.7 1 0.45
TOSTADORA 1 1600 120 14.2 0.5 0.8
CENTRO DE
LAVADO FOCO LED 1 11 127 1.0 2 0.022
SECADORA 1 1830 120 16.2 3 5.49
LAVADORA 1 2438 127 20.1 2 4.876
PATIO FOCO LED 2 11 127 1.0 3 0.066
VENTILADOR
RECAMARA 1DE TECHO 1 60.5 120 1.4 24 1.452
LAPTOP 1 200 127 2.5 4 0.8
VENTILADOR
RECAMARA 2DE TECHO 1 60.5 120 1.4 24 1.452
LAPTOP 1 200 127 2.5 4 0.8
ESTUDIO TELVISION 1 180 240 1.7 1 0.18
LAPTOP 1 200 127 2.5 5 1
VENTILADOR 1 11 127 1.0 3 0.033
CAJA
INTERNET 1 304.84 12 26.3 24 7.31616
BAÑO FOCO LED 1 11 127 1.0 3 0.033
RECAMARA 3ILUM 1 11 127 1.0 3 0.033
LAPTOP 1 200 127 2.5 5 1
COSTO costo COSTO
KWh/ COSTO BASE COSTO BASE INTERMEDIO intermedio EXCEDENTE
ACUMULAD ENERGIA (0 ACUMULAD ACUMULADO
ENERGIA (1.51 a acumulado ENERGIA
KWH/BIM OS a 150) O ENERGIA 280) energia (281 a 500)

0.86 1.04 3.03


3.96 3.96 3.4056 3.4056

15.12 19.08 13.0032 16.4088


1575 1594.08 1354.5 1370.9088
384 1978.08 330.24 1701.1488
10.8 1988.88 9.288 1710.4368
18 2006.88 15.48 1725.9168

540 2546.88 464.4 2190.3168

87.12 2634 74.9232 2265.24


13.2 2647.2 11.352 2276.592
2.64 2649.84 2.2704 2278.8624
3.3 2653.14 2.838 2281.7004
216 2869.14 185.76 2467.4604
144 3013.14 123.84 2591.3004
54 3067.14 46.44 2637.7404
9.6 3076.74 8.256 2645.9964
27 3103.74 23.22 2669.2164
48 3151.74 41.28 2710.4964

1.32 3153.06 1.1352 2711.6316


329.4 3482.46 283.284 2994.9156
292.56 3775.02 251.6016 3246.5172
3.96 3778.98 3.4056 3249.9228

87.12 3866.1 74.9232 3324.846


48 3914.1 41.28 3366.126

87.12 4001.22 74.9232 3441.0492


48 4049.22 41.28 3482.3292
10.8 4060.02 9.288 3491.6172
60 4120.02 51.6 3543.2172
1.98 4122 1.7028 3544.92

438.9696 4560.9696 377.513856 3922.43386


1.98 4562.9496 1.7028 3924.13666
1.98 4564.9296 1.7028 3925.83946
60 4624.9296 51.6 3977.43946
3 BIM
CONSUMO >
COSTO EXCEDENTE 500 KWh COSTO
ACUMULADO TARIFA DAC TOTAL DE
ENERGIA ENERGIA LA ENERGIA
1er Kwh a
consumo
(4.3)
casa Habitacion PRIMERA PLANTA
centro de cargas QOD-02
1F-2H,127V,60 AMP
TLABERO

NUMERO DE CONTACTO ARBOTANTE REFRIG 265


UBICACIÓN CIRCUITO 162 W ILUM 10 W 10 W W

CIRCUITO CASA C-1 5 1


C-2 2 1
C-3 1 1
C-4 7 2 1 1
C-5 3 1 1

SEGUNDA PLANTA

NUMERO DE CONTACTO ARBOTANTE REFRIG 265


UBICACIÓN CIRCUITO 162 W ILUM 10 W 10 W W

CIRCUITO CASA C-1 2 1


C-2 2 1
C-3 2 1
C-4 3 2
MICRO 1200 LAVADORA SECADORA BOMBA 458 POTENCIA VOLTAJE INTENSIDAD I'1.25
W 400 W 400 W W WATTS VOLTS AMPERES SELECC ITM

820 127 71.7410324 89.6762905


334 127 29.2213473 36.5266842
172 127 15.048119 18.8101487
1 1 1 3429 127 300 375
1 974 127 85.2143482 106.517935

MICRO 1200 LAVADORA SECADORA BOMBA 458 POTENCIA VOLTAJE INTENSIDAD I'1.25
W 400 W 400 W W WATTS VOLTS AMPERES SELECC ITM

334 127 29.2213473 36.5266842


334 127 29.2213473 36.5266842
334 127 29.2213473 36.5266842
506 127 44.2694663 55.3368329
CAPACIDAD
INT. TERMO
MAGNETICO WATTS

1P-50A 820
1P-50A 334
1P-50A 172
1P-50A 3429
1P-50A 974

CAPACIDAD
INT. TERMO
MAGNETICO WATTS

1P-50A 334
1P-50A 334
1P-50A 334
1P-50A 506