Está en la página 1de 1

12.

10

1 2 3 4 5 6 7

X X X' X' X X X' X X

6Ø 5/8"

1.40
A
C-1 C-2 C-3 C-2 C-3 C-2 C-1

4Ø 1/2"
N N X X X' X' X X X' X X N N
1 @ 0.05
Ø 3/8" 6 @ 0.10
X'' X'' X'' X'' Ø 3/8" R @ 0.25

2Ø 5/8"

AULA 02 AULA 03
C-4

C-4

C-4

C-4
B AULA 01

COLUMNAS C-1 1ER y 2DO PISO


X'' X'' X'' X'' N N
N N 1.40
.90 X X X X X X

C-1 C-2 C-3 C-2 C-3 C-2 C-1


C

2 Ø5/8" 2 Ø5/8"
X X X X X X 4 Ø1/2"

1 2 3 4 5 6 7
4 Ø5/8"
2 Ø1/2"
Ø 3/8" 1 @ 0.05

CIMENTACION MODULO 1 3 Ø3/4"


Ø 3/8" 8 @ 0.10
R @ 0.25

COLUMNAS C-2 1ER y 2DO PISO

.22 .22

.12

NPT+0.15 m NPT+0.15 m NPT+0.15 m NPT+0.15 m


.10 .10 NPT+/- 0.00 m
NPT+/- 0.00 m NPT+/- 0.00 m NPT+/- 0.00 m
.25 .05 CEMENTO PULIDO CEMENTO PULIDO .05 CEMENTO PULIDO CEMENTO PULIDO .25 .05 CEMENTO PULIDO CEMENTO PULIDO CEMENTO PULIDO CEMENTO PULIDO .05 .25
.10 FALSO PISO FALSO PISO .10 FALSO PISO FALSO PISO .10 FALSO PISO FALSO PISO FALSO PISO FALSO PISO .10 2 Ø5/8" 2 Ø5/8"
4 Ø1/2"
.15 AFIRMADO .25 AFIRMADO .15 AFIRMADO .25 AFIRMADO .15 AFIRMADO .25 AFIRMADO AFIRMADO AFIRMADO .15

Ø 3/8" 1 @ 0.10 Ø 3/8" 1 @ 0.10 Ø 3/8" 1 @ 0.10 Ø 3/8" 1 @ 0.10


.40 4 Ø 3/8"
2 @ 0.15 2 @ 0.15 2 @ 0.15 2 @ 0.15
6Ø3/8" R @ 0.20 6Ø3/8" R @ 0.20 6Ø3/8" R @ 0.20 1 @ 0.05
.65 1.00 .65 .65 R @ 0.20 Ø 3/8"
f'c=210 Kg/cm2 .75 8 @ 0.10
f'c=210 Kg/cm2 f'c=210 Kg/cm2 f'c=210 Kg/cm2 SOBRECIMIENTO REFORZADO .30 Ø 3/8"
.35 .35 .35 3Ø5/8" R @ 0.25
1.50

.20 f'c=210Kg/cm2 .25 2Ø3/4"+1Ø5/8" .20 f'c=210Kg/cm2 .25 2Ø3/4"+1Ø5/8" .20 f'c=210Kg/cm2 .25 2Ø3/4"+1Ø5/8" .10 4Ø5/8"
1.50 1.50 1.50 .20 2 Ø1/2"
Ø5/8"@.26 cm Ø5/8"@.26 cm Ø5/8"@.26 cm Ø5/8"@.26 cm Ø5/8"@.26 cm Ø5/8"@.26 cm Ø5/8"@.26
2Ø1/2" 2Ø1/2" 2Ø1/2"
.50 .50 .50 Ø5/8"@.26 cm Ø5/8"@.26 cm .50
3 Ø3/4"

NC-1.60 m NC-1.60 m NC-1.60 m NC - 1.60 m


SOLADO SOLADO .10 SOLADO SOLADO .10 SOLADO SOLADO .10 SOLADO .10

2Ø3/4"+1Ø5/8"
2Ø3/4"+1Ø5/8" 2Ø3/4"+1Ø5/8" 2Ø3/4"+1Ø5/8"
.90 COLUMNAS C-3 1ER y 2DO PISO
1.40 1.40 1.40

SECCION X-X SECCION X'-X' SECCION X''-X'' SECCION N-N


VCC-A VCC-A VCC-2 VIGA VCC-1

.20
.20
S MUNICIPALIDAD DISTRITAL DE CHINGALPO
VALORES DE EMPALMES EN VCC 4 Ø5/8" MDCH
AUTORIDAD DE RECONSTRUCCION CON CAMBIOS
REFUERZO SUPERIOR REFUERZO INFERIOR
.20 Ø ARCC
H CUALQUIERA H<30 H>30
S
.40 3/8" 0.40 0.40 0.45 PLANO:
PROGRAMA:
.40
1/2" 0.40 0.40 0.50
ARCC ESTRUCTURAS - MODULO 1
.12 Var. C-A AUTORIDAD DE
RECONSTRUCCION CON CAMBIOS CIMENTACION - PLANTA
.12 4 Ø1/2" PROYECTO:
5/8" 0.50 0.45 0.60
MEJORAMIENTO DE LOS SERVICIOS EDUCATIVOS
.12
S-S 3/4" 0.60 0.55 0.75 A NIVEL PRIMARIA EN LA IE N 84179 DEL RESPONSABLE :

.12 DEL CP SAN MIGUEL, DISTRITO DE CHINGALPO ING CARLOS NIKE LIMA VALDIVIA
CIP 161142
NPT+0.15 m
COLUMNAS C-4 1ER Y 2DO PISO SIHUAS - ANCASH
1" 1.15 1.00 1.30 CODIGO SNIP Nº342911 ELABORADO :

- RINO'S CAD -
UBICACION:
CP SAN MIGUEL

También podría gustarte