Documentos de Académico
Documentos de Profesional
Documentos de Cultura
TAREA EN CLASE 2
INTEGRANTES:
BONILLA NICOLÁS E.
MEJÍA SÁNCHEZ DENNIS W.
RODAS SEGARRA PABLO J.
TOAQUIZA PATRICIO
PONCE ROMERO CARLOS A.
ASIGNATURA: HIDROLOGÍA.
DATOS:
• ℎ = 10 𝑘𝑚
• 𝑇1 = 30℃ = 𝟑𝟎𝟑𝒐 𝑲 30℃ + 283𝑜 𝐾 = 303𝑜 𝐾
• 𝐴 = 1 𝑚2
• 𝑝1 = 101,3 𝑘𝑃𝑎
℃ 𝟎,𝟐𝟕𝟗𝟓 𝒐 𝑲 ℃ 1𝑘𝑚 273𝑜 𝐾 0,2795 𝑜 𝐾
• 𝛼 = 6,5 𝑘𝑚 = 6,5 𝑘𝑚 ∗ 1000 𝑚 ∗ =
𝒎 1℃ 𝑚
𝐽
• 𝑅𝑎 = 287 𝑘𝑔∗𝑜 𝐾
TEMPERATURA 2:
𝑻𝟐 = 𝑻𝟏 − 𝜶 ∗ (𝒛𝟐 − 𝒛𝟏 )
0, 2795 𝑜 𝐾
𝑇2 = 303𝑜 𝐾 − ∗ (1000 𝑚 − 0 𝑚)
𝑚
𝑻𝟐 = 𝟐𝟗𝟔, 𝟓𝒐 𝑲
PRESIÓN DE AIRE 2:
𝑚
𝒈 9,81 2
= 𝑠 = 0,122
𝜶 ∗ 𝑹𝒂 0, 2795 𝑜 𝐾 ∗ 287 𝐽
𝑚 𝑜
𝑘𝑔 ∗ 𝐾
𝒈
𝑻𝟐 𝜶∗𝑹𝒂
𝒑𝟐 = 𝒑𝟏 ∗ ( )
𝑻𝟏
0,122
296, 5𝑜 𝐾
𝑝2 = 101,3 𝑘𝑃𝑎 ∗ ( )
303𝑜 𝐾
𝒑𝟐 = 𝟏𝟎𝟏, 𝟎𝟑 𝒌𝑷𝒂
DENSIDAD:
𝒑𝒂
𝝆𝒂 =
𝑹𝒂 ∗ 𝑻
101,3 𝑘𝑃𝑎
𝜌1 =
𝐽
287 ∗ 303𝑜 𝐾
𝑘𝑔 ∗𝑜 𝐾
𝒌𝒈
𝝆𝟏 = 𝟏, 𝟏𝟔
𝒎𝟑
101,3 𝑘𝑃𝑎
𝜌2 =
𝐽
287 ∗ 296, 5𝑜 𝐾
𝑘𝑔 ∗𝑜 𝐾
𝒌𝒈
𝝆𝟐 = 𝟏, 𝟏𝟗
𝒎𝟑
PRESION DE VAPOR:
𝟏𝟕. 𝟐𝟕𝑻
𝐞𝟏 = 𝟔𝟏𝟏 𝐞𝐱𝐩( )
𝟐𝟑𝟕. 𝟑 + 𝑻
17.27 𝑥 30
e1 = 611 exp( )
237.3 + 30
𝐞𝟏 = 𝟒𝟐𝟒𝟒 𝐏𝐚 = 𝟒. 𝟐𝟒 𝐊𝐩𝐚
17.27 𝑥 23.5
e2 = 611 exp( )
237.3 + 23.5
𝐞𝟐 = 𝟐𝟖𝟗𝟔 𝑷𝒂 = 𝟐. 𝟗𝟎 𝑲𝒑𝒂
HUMEDAD ESPECIFICA:
𝒆
𝒒𝒗 = 𝟎. 𝟔𝟐𝟐
𝒑
4.24 𝐾𝑝𝑎
𝑞𝑣1 = 0.622
101.3𝐾𝑝𝑎
2.90𝐾𝑝𝑎
𝑞𝑣2 = 0.622
101.3𝐾𝑝𝑎
∆𝒎𝒑 = 𝒒𝒗 𝒑𝒂 𝑨 ∆𝒁
∆𝒎𝒑 = 𝟐𝟓. 𝟖𝟓 𝒌𝒈
TEMPERATURA 3:
𝑻𝟑 = 𝑻𝟐 − 𝜶 ∗ (𝒛𝟑 − 𝒛𝟐 )
0, 2795 𝑜 𝐾
𝑇3 = 296,5 𝐾 − ∗ (2000 𝑚 − 1000 𝑚)
𝑚
𝑻𝟑 = 𝟐𝟗𝟎 °𝒌
PRESIÓN DE AIRE 3:
𝑚
𝒈 9,81 2
= 𝑠 = 0,122
𝜶 ∗ 𝑹𝒂 0, 2795 𝑜 𝐾 ∗ 287 𝐽
𝑚 𝑘𝑔 ∗𝑜 𝐾
𝒈
𝑻𝟑 𝜶∗𝑹𝒂
𝒑𝟑 = 𝒑𝟐 ∗ ( )
𝑻𝟐
290 °𝐾 0,122
𝑝3 = 101,0317 𝑘𝑃𝑎 ∗ ( )
296.5 °𝐾
DENSIDAD:
𝒑𝒂
𝝆𝒂 =
𝑹𝒂 ∗ 𝑻
101,0317 𝑘𝑃𝑎
𝜌2 =
𝐽
287 ∗ 296,5 𝑜 𝐾
𝑘𝑔 ∗𝑜 𝐾
𝒌𝒈
𝝆𝟐 = 𝟏, 𝟏𝟖𝟕𝟑
𝒎𝟑
101,0317 𝑘𝑃𝑎
𝜌3 =
𝐽
287 ∗ 290 °𝐾
𝑘𝑔 ∗𝑜 𝐾
𝒌𝒈
𝝆𝟑 = 𝟏, 𝟐𝟏𝟎𝟔
𝒎𝟑
PRESION DE VAPOR:
𝟏𝟕. 𝟐𝟕𝑻
𝐞 = 𝟔𝟏𝟏 𝐞𝐱𝐩( )
𝟐𝟑𝟕. 𝟑 + 𝑻
17.27 𝑥 23.5
e2 = 611 exp( )
237.3 + 23.5
17.27 𝑥 17
e3 = 611 exp( )
237.3 + 17
HUMEDAD ESPECIFICA:
𝒆
𝒒𝒗 = 𝟎. 𝟔𝟐𝟐
𝒑
2.90 𝐾𝑝𝑎
𝑞𝑣2 = 0.622
101.0317 𝐾𝑝𝑎
1.94 𝐾𝑝𝑎
𝑞𝑣3 = 0.622
101.0317 𝐾𝑝𝑎
∆𝒎𝒑 = 𝒒𝒗 𝒑𝒂 𝑨 ∆𝒁
TEMPERATURA 4:
𝑻𝟒 = 𝑻𝟑 − 𝜶 ∗ (𝒛𝟒 − 𝒛𝟑 )
0, 2795 𝑜 𝐾
𝑇4 = 290 𝐾 − ∗ (3000 𝑚 − 2000 𝑚)
𝑚
𝑻𝟒 = 𝟐𝟖𝟑. 𝟓 °𝒌
PRESIÓN DE AIRE 4:
𝑚
𝒈 9,81 2
= 𝑠 = 0,122
𝜶 ∗ 𝑹𝒂 0, 2795 𝑜 𝐾 ∗ 287 𝐽
𝑚 𝑘𝑔 ∗𝑜 𝐾
𝒈
𝑻𝟒 𝜶∗𝑹𝒂
𝒑𝟒 = 𝒑𝟑 ∗ ( )
𝑻𝟑
283.5 °𝐾 0,122
𝑝4 = 100.7582 𝑘𝑃𝑎 ∗ ( )
290 °𝐾
DENSIDAD:
𝒑𝒂
𝝆𝒂 =
𝑹𝒂 ∗ 𝑻
100.7582 𝑘𝑃𝑎
𝜌3 =
𝐽
287 ∗ 290 𝑜 𝐾
𝑘𝑔 ∗𝑜 𝐾
𝒌𝒈
𝝆𝟑 = 𝟏, 𝟐𝟏𝟎𝟔
𝒎𝟑
100.7582 𝑘𝑃𝑎
𝜌4 =
𝐽
287 ∗ 283.5 °𝐾
𝑘𝑔 ∗𝑜 𝐾
𝒌𝒈
𝝆𝟒 = 𝟏, 𝟐𝟑𝟒𝟗
𝒎𝟑
PRESION DE VAPOR:
𝟏𝟕. 𝟐𝟕𝑻
𝐞 = 𝟔𝟏𝟏 𝐞𝐱𝐩( )
𝟐𝟑𝟕. 𝟑 + 𝑻
17.27 𝑥 17
e3 = 611 exp( )
237.3 + 17
17.27 𝑥 10.5
e4 = 611 exp( )
237.3 + 10.5
HUMEDAD ESPECIFICA:
𝒆
𝒒𝒗 = 𝟎. 𝟔𝟐𝟐
𝒑
1.94 𝐾𝑝𝑎
𝑞𝑣3 = 0.622
100.7582𝐾𝑝𝑎
𝒒𝒗𝟑 = 𝟎, 𝟎𝟏𝟐 𝑲𝒈/𝒌𝒈
1.27 𝐾𝑝𝑎
𝑞𝑣4 = 0.622
100.7582 𝐾𝑝𝑎
∆𝒎𝒑 = 𝒒𝒗 𝒑𝒂 𝑨 ∆𝒁
TEMPERATURA 5:
𝑻𝟓 = 𝑻𝟒 − 𝜶 ∗ (𝒛𝟓 − 𝒛𝟒 )
0, 2795 𝑜 𝐾
𝑇5 = 283.5 𝐾 − ∗ (4000 𝑚 − 3000 𝑚)
𝑚
𝑻𝟓 = 𝟐𝟕𝟕 °𝒌
PRESIÓN DE AIRE 5:
𝑚
𝒈 9,81 2
= 𝑠 = 0,122
𝜶 ∗ 𝑹𝒂 0, 2795 𝑜 𝐾 ∗ 287 𝐽
𝑚 𝑘𝑔 ∗𝑜 𝐾
𝒈
𝑻𝟓 𝜶∗𝑹𝒂
𝒑𝟓 = 𝒑𝟒 ∗ ( )
𝑻𝟒
277 °𝐾 0,122
𝑝5 = 100.4792 𝑘𝑃𝑎 ∗ ( )
283.5 °𝐾
DENSIDAD:
𝒑𝒂
𝝆𝒂 =
𝑹𝒂 ∗ 𝑻
100.4792 𝑘𝑃𝑎
𝜌4 =
𝐽
287 ∗ 283.5 𝑜 𝐾
𝑘𝑔 ∗𝑜 𝐾
𝒌𝒈
𝝆𝟒 = 𝟏, 𝟐𝟑𝟒𝟗
𝒎𝟑
100.4792 𝑘𝑃𝑎
𝜌5 =
𝐽
287 ∗ 277 °𝐾
𝑘𝑔 ∗𝑜 𝐾
𝒌𝒈
𝝆𝟓 = 𝟏, 𝟐𝟔𝟎𝟑
𝒎𝟑
PRESION DE VAPOR:
𝟏𝟕. 𝟐𝟕𝑻
𝐞 = 𝟔𝟏𝟏 𝐞𝐱𝐩( )
𝟐𝟑𝟕. 𝟑 + 𝑻
17.27 𝑥 10.5
e4 = 611 exp( )
237.3 + 10.5
HUMEDAD ESPECIFICA:
𝒆
𝒒𝒗 = 𝟎. 𝟔𝟐𝟐
𝒑
1.27 𝐾𝑝𝑎
𝑞𝑣4 = 0.622
100.4792𝐾𝑝𝑎
0.81 𝐾𝑝𝑎
𝑞𝑣5 = 0.622
100.4792 𝐾𝑝𝑎
∆𝒎𝒑 = 𝒒𝒗 𝒑𝒂 𝑨 ∆𝒁
∆𝒎𝒑𝟒−𝟓 = 𝟖, 𝟏𝟎𝟗𝟒 𝒌𝒈
TEMPERATURA 6:
𝑻𝟔 = 𝑻𝟓 − 𝜶 ∗ (𝒛𝟔 − 𝒛𝟓 )
0, 2795 𝑜 𝐾
𝑇6 = 277 𝐾 − ∗ (5000 𝑚 − 4000 𝑚)
𝑚
𝑻𝟔 = 𝟐𝟕𝟎, 𝟓 °𝒌
PRESIÓN DE AIRE 6:
𝑚
𝒈 9,81 2
= 𝑠 = 0,122
𝜶 ∗ 𝑹𝒂 0, 2795 𝑜 𝐾 ∗ 287 𝐽
𝑚 𝑘𝑔 ∗𝑜 𝐾
𝒈
𝑻𝟔 𝜶∗𝑹𝒂
𝒑𝟔 = 𝒑𝟓 ∗ ( )
𝑻𝟓
270.5 °𝐾 0,122
𝑝6 = 100.1946 𝑘𝑃𝑎 ∗ ( )
277 °𝐾
DENSIDAD:
𝒑𝒂
𝝆𝒂 =
𝑹𝒂 ∗ 𝑻
100.1946 𝑘𝑃𝑎
𝜌5 =
𝐽
287 ∗ 277 𝑜 𝐾
𝑘𝑔 ∗𝑜 𝐾
𝒌𝒈
𝝆𝟓 = 𝟏, 𝟐𝟔𝟎𝟑
𝒎𝟑
100.1946 𝑘𝑃𝑎
𝜌6 =
𝐽
287 ∗ 270.5 °𝐾
𝑘𝑔 ∗𝑜 𝐾
𝒌𝒈
𝝆𝟔 = 𝟏, 𝟐𝟖𝟔𝟗
𝒎𝟑
PRESION DE VAPOR:
𝟏𝟕. 𝟐𝟕𝑻
𝐞 = 𝟔𝟏𝟏 𝐞𝐱𝐩( )
𝟐𝟑𝟕. 𝟑 + 𝑻
17.27 𝑥 4
e5 = 611 exp( )
237.3 + 4
17.27 𝑥 (−2.5)
e6 = 611 exp( )
237.3 + (−2.5)
HUMEDAD ESPECIFICA:
𝒆
𝒒𝒗 = 𝟎. 𝟔𝟐𝟐
𝒑
0.81 𝐾𝑝𝑎
𝑞𝑣5 = 0.622
100.1946 𝐾𝑝𝑎
0.51 𝐾𝑝𝑎
𝑞𝑣6 = 0.622
100.1946 𝐾𝑝𝑎
∆𝒎𝒑 = 𝒒𝒗 𝒑𝒂 𝑨 ∆𝒁
TEMPERATURA 7:
𝑻𝟕 = 𝑻𝟔 − 𝜶 ∗ (𝒛𝟕 − 𝒛𝟔 )
0, 2795 𝑜 𝐾
𝑇7 = 270,5 𝐾 − ∗ (6000 𝑚 − 5000 𝑚)
𝑚
𝑻𝟕 = 𝟐𝟔𝟒 °𝒌
PRESIÓN DE AIRE 7:
𝑚
𝒈 9,81 2
= 𝑠 = 0,122
𝜶 ∗ 𝑹𝒂 0, 2795 𝑜 𝐾 ∗ 287 𝐽
𝑚 𝑘𝑔 ∗𝑜 𝐾
𝒈
𝑻𝟕 𝜶∗𝑹𝒂
𝒑𝟕 = 𝒑𝟔 ∗ ( )
𝑻𝟔
264 °𝐾 0,122
𝑝7 = 99.9041 𝑘𝑃𝑎 ∗ ( )
270.5 °𝐾
DENSIDAD:
𝒑𝒂
𝝆𝒂 =
𝑹𝒂 ∗ 𝑻
99.9041 𝑘𝑃𝑎
𝜌6 =
𝐽
287 ∗ 270.5 𝑜 𝐾
𝑘𝑔 ∗𝑜 𝐾
𝒌𝒈
𝝆𝟔 = 𝟏, 𝟐𝟖𝟔𝟗
𝒎𝟑
99.9041 𝑘𝑃𝑎
𝜌7 =
𝐽
287 ∗ 264 °𝐾
𝑘𝑔 ∗𝑜 𝐾
𝒌𝒈
𝝆𝟕 = 𝟏, 𝟑𝟏𝟒𝟔
𝒎𝟑
PRESION DE VAPOR:
𝟏𝟕. 𝟐𝟕𝑻
𝐞 = 𝟔𝟏𝟏 𝐞𝐱𝐩( )
𝟐𝟑𝟕. 𝟑 + 𝑻
17.27 𝑥 (−2.5)
e6 = 611 exp( )
237.3 + (−2.5)
17.27 𝑥 (−9)
e7 = 611 exp( )
237.3 + (−9)
HUMEDAD ESPECIFICA:
𝒆
𝒒𝒗 = 𝟎. 𝟔𝟐𝟐
𝒑
0.51 𝐾𝑝𝑎
𝑞𝑣6 = 0.622
99.9041 𝐾𝑝𝑎
𝒒𝒗𝟔 = 𝟎, 𝟎𝟎𝟑𝟐 𝑲𝒈/𝒌𝒈
0.31 𝐾𝑝𝑎
𝑞𝑣7 = 0.622
99.9041𝐾𝑝𝑎
∆𝒎𝒑 = 𝒒𝒗 𝒑𝒂 𝑨 ∆𝒁
∆𝒎𝒑𝟔−𝟕 = 𝟑, 𝟑𝟖𝟐𝟏 𝒌𝒈
TEMPERATURA 8:
𝑻𝟖 = 𝑻𝟕 − 𝜶 ∗ (𝒛𝟖 − 𝒛𝟕 )
0, 2795 𝑜 𝐾
𝑇8 = 264 𝐾 − ∗ (7000 𝑚 − 6000 𝑚)
𝑚
𝑻𝟖 = 𝟐𝟓𝟕, 𝟓 °𝒌
PRESIÓN DE AIRE 8:
𝑚
𝒈 9,81 2
= 𝑠 = 0,122
𝜶 ∗ 𝑹𝒂 0, 2795 𝑜 𝐾 ∗ 287 𝐽
𝑚 𝑘𝑔 ∗𝑜 𝐾
𝒈
𝑻𝟖 𝜶∗𝑹𝒂
𝒑𝟖 = 𝒑𝟕 ∗ ( )
𝑻𝟕
257.5 °𝐾 0,122
𝑝8 = 99.6074 𝑘𝑃𝑎 ∗ ( )
264 °𝐾
DENSIDAD:
𝒑𝒂
𝝆𝒂 =
𝑹𝒂 ∗ 𝑻
99.6074 𝑘𝑃𝑎
𝜌7 =
𝐽
287 ∗ 264 𝑜 𝐾
𝑘𝑔 ∗𝑜 𝐾
𝒌𝒈
𝝆𝟕 = 𝟏, 𝟑𝟏𝟒𝟔
𝒎𝟑
99.6074 𝑘𝑃𝑎
𝜌8 =
𝐽
287 ∗ 257.5 °𝐾
𝑘𝑔 ∗𝑜 𝐾
𝒌𝒈
𝝆𝟖 = 𝟏, 𝟑𝟒𝟑𝟕
𝒎𝟑
PRESION DE VAPOR:
𝟏𝟕. 𝟐𝟕𝑻
𝐞 = 𝟔𝟏𝟏 𝐞𝐱𝐩( )
𝟐𝟑𝟕. 𝟑 + 𝑻
17.27 𝑥 (−9)
e7 = 611 exp( )
237.3 + (−9)
HUMEDAD ESPECIFICA:
𝒆
𝒒𝒗 = 𝟎. 𝟔𝟐𝟐
𝒑
0.31 𝐾𝑝𝑎
𝑞𝑣7 = 0.622
99.6074 𝐾𝑝𝑎
0.18 𝐾𝑝𝑎
𝑞𝑣8 = 0.622
99.6074 𝐾𝑝𝑎
∆𝒎𝒑 = 𝒒𝒗 𝒑𝒂 𝑨 ∆𝒁
∆𝒎𝒑𝟕−𝟖 = 𝟏, 𝟗𝟗𝟑𝟖 𝒌𝒈
TEMPERATURA 9:
𝑻𝟗 = 𝑻𝟖 − 𝜶 ∗ (𝒛𝟗 − 𝒛𝟖 )
0, 2795 𝑜 𝐾
𝑇9 = 257.5 𝐾 − ∗ (8000 𝑚 − 7000 𝑚)
𝑚
𝑻𝟗 = 𝟐𝟓𝟏 °𝒌
PRESIÓN DE AIRE 9:
𝑚
𝒈 9,81 2
= 𝑠 = 0,122
𝜶 ∗ 𝑹𝒂 0, 2795 𝑜 𝐾 ∗ 287 𝐽
𝑚 𝑘𝑔 ∗𝑜 𝐾
𝒈
𝑻𝟗 𝜶∗𝑹𝒂
𝒑𝟗 = 𝒑𝟖 ∗ ( )
𝑻𝟖
251 °𝐾 0,122
𝑝9 = 99.3042 𝑘𝑃𝑎 ∗ ( )
257.5 °𝐾
DENSIDAD:
𝒑𝒂
𝝆𝒂 =
𝑹𝒂 ∗ 𝑻
99.3042 𝑘𝑃𝑎
𝜌8 =
𝐽
287 ∗ 257.5 𝑜 𝐾
𝑘𝑔 ∗𝑜 𝐾
𝒌𝒈
𝝆𝟖 = 𝟏, 𝟑𝟒𝟑𝟕
𝒎𝟑
99.3042 𝑘𝑃𝑎
𝜌9 =
𝐽
287 ∗ 251 °𝐾
𝑘𝑔 ∗𝑜 𝐾
𝒌𝒈
𝝆𝟗 = 𝟏, 𝟑𝟕𝟒𝟐
𝒎𝟑
PRESION DE VAPOR:
𝟏𝟕. 𝟐𝟕𝑻
𝐞 = 𝟔𝟏𝟏 𝐞𝐱𝐩( )
𝟐𝟑𝟕. 𝟑 + 𝑻
17.27 𝑥 (−15.5)
e8 = 611 exp( )
237.3 + (−15.5)
17.27 𝑥 (−22)
e9 = 611 exp( )
237.3 + (−22)
HUMEDAD ESPECIFICA:
𝒆
𝒒𝒗 = 𝟎. 𝟔𝟐𝟐
𝒑
0.18 𝐾𝑝𝑎
𝑞𝑣8 = 0.622
99.3042 𝐾𝑝𝑎
0.10 𝐾𝑝𝑎
𝑞𝑣9 = 0.622
99.3042 𝐾𝑝𝑎
∆𝒎𝒑 = 𝒒𝒗 𝒑𝒂 𝑨 ∆𝒁
TEMPERATURA 10:
𝑻𝟏𝟎 = 𝑻𝟗 − 𝜶 ∗ (𝒛𝟏𝟎 − 𝒛𝟗 )
0, 2795 𝑜 𝐾
𝑇10 = 251 𝐾 − ∗ (9000 𝑚 − 8000 𝑚)
𝑚
𝑻𝟏𝟎 = 𝟐𝟒𝟒, 𝟓 °𝒌
𝒈
𝑻𝟏𝟎 𝜶∗𝑹𝒂
𝒑𝟏𝟎 = 𝒑𝟗 ∗ ( )
𝑻𝟗
244.5 °𝐾 0,122
𝑝10 = 98.9942 𝑘𝑃𝑎 ∗ ( )
251 °𝐾
DENSIDAD:
𝒑𝒂
𝝆𝒂 =
𝑹𝒂 ∗ 𝑻
98.9942 𝑘𝑃𝑎
𝜌9 =
𝐽
287 ∗ 251 𝑜 𝐾
𝑘𝑔 ∗𝑜 𝐾
𝒌𝒈
𝝆𝟗 = 𝟏, 𝟑𝟕𝟒𝟐
𝒎𝟑
98.9942 𝑘𝑃𝑎
𝜌10 =
𝐽
287 ∗ 244.5 °𝐾
𝑘𝑔 ∗𝑜 𝐾
𝒌𝒈
𝝆𝟏𝟎 = 𝟏, 𝟒𝟎𝟔𝟐
𝒎𝟑
PRESION DE VAPOR:
𝟏𝟕. 𝟐𝟕𝑻
𝐞 = 𝟔𝟏𝟏 𝐞𝐱𝐩( )
𝟐𝟑𝟕. 𝟑 + 𝑻
17.27 𝑥 (−22)
e9 = 611 exp( )
237.3 + (−22)
17.27 𝑥 (−28.5)
e10 = 611 exp( )
237.3 + (−28.5)
HUMEDAD ESPECIFICA:
𝒆
𝒒𝒗 = 𝟎. 𝟔𝟐𝟐
𝒑
0.10 𝐾𝑝𝑎
𝑞𝑣9 = 0.622
98.9942 𝐾𝑝𝑎
𝒒𝒗𝟗 = 𝟎, 𝟎𝟎𝟎𝟕 𝑲𝒈/𝒌𝒈
0.06 𝐾𝑝𝑎
𝑞𝑣10 = 0.622
98.9942 𝐾𝑝𝑎
∆𝒎𝒑 = 𝒒𝒗 𝒑𝒂 𝑨 ∆𝒁
∆𝒎𝒑𝟗−𝟏𝟎 = 𝟎, 𝟖𝟑𝟒𝟏 𝒌𝒈
TEMPERATURA 11:
0, 2795 𝑜 𝐾
𝑇11 = 244.5 𝐾 − ∗ (10000 𝑚 − 9000 𝑚)
𝑚
𝑻𝟏𝟏 = 𝟐𝟑𝟖 °𝒌
𝒈
𝑻𝟏𝟏 𝜶∗𝑹𝒂
𝒑𝟏𝟏 = 𝒑𝟏𝟎 ∗ ( )
𝑻𝟏𝟎
238 °𝐾 0,122
𝑝11 = 98.6771 𝑘𝑃𝑎 ∗ ( )
244.5 °𝐾
DENSIDAD:
𝒑𝒂
𝝆𝒂 =
𝑹𝒂 ∗ 𝑻
98.6771 𝑘𝑃𝑎
𝜌10 =
𝐽
287 ∗ 244.5 𝑜 𝐾
𝑘𝑔 ∗𝑜 𝐾
𝒌𝒈
𝝆𝟏𝟎 = 𝟏, 𝟒𝟎𝟔𝟐
𝒎𝟑
98.6771 𝑘𝑃𝑎
𝜌11 =
𝐽
287 ∗ 238 °𝐾
𝑘𝑔 ∗𝑜 𝐾
𝒌𝒈
𝝆𝟏𝟏 = 𝟏, 𝟒𝟑𝟗𝟗
𝒎𝟑
PRESION DE VAPOR:
𝟏𝟕. 𝟐𝟕𝑻
𝐞 = 𝟔𝟏𝟏 𝐞𝐱𝐩( )
𝟐𝟑𝟕. 𝟑 + 𝑻
17.27 𝑥 (−28.5)
e10 = 611 exp( )
237.3 + (−28.5)
HUMEDAD ESPECIFICA:
𝒆
𝒒𝒗 = 𝟎. 𝟔𝟐𝟐
𝒑
0.06 𝐾𝑝𝑎
𝑞𝑣10 = 0.622
98.6771 𝐾𝑝𝑎
0.03 𝐾𝑝𝑎
𝑞𝑣11 = 0.622
98.6771 𝐾𝑝𝑎
𝒑 = 𝒒𝒗 𝒑𝒂 𝑨 ∆𝒁
∆𝒎𝒑𝟏𝟎−−𝟏 = 𝟎, 𝟒𝟐𝟔𝟗 𝒌𝒈
Tabla. Cálculo del Agua Precipitable en una Columna de Aire Saturado.
Elevación Temperatura Presión de Densidad Presión de Humedad Promedio sobre el Masa Porcentaje
aire vapor específica incremento incremental de masa
total
Z T T P ρa e qv ̅̅̅̅
𝐪𝐯 ̅̅̅̅
𝝆𝒂 Δm
(km) (°C) (°K) (kPa) (kg/𝒎𝟑 ) (kPa) (kg/kg) (kg/kg) (kg/𝒎𝟑 ) (kg)
0 30 303 101.30 1.1649 4.2445 0.0261 - - - -
1 23.5 296.5 101.0317 1.1873 2.8965 0.0178 0.0220 1.1761 25.8742 33.48%
2 17 290 100.7582 1.2106 1.9384 0.0120 0.0149 1.1990 17.8651 23.12%
3 10.5 283.5 100.4792 1.2349 1.2701 0.0079 0.0100 1.2228 12.2280 15.82%
4 4 277 100.1946 1.2603 0.8135 0.0051 0.0065 1.2476 8.1094 10.49%
5 -2.5 270.5 99.9041 1.2869 0.5084 0.0032 0.0042 1.2736 5.3491 6.92%
6 -9 264 99.6074 1.3146 0.3093 0.0019 0.0026 1.3008 3.3821 4.38%
7 -15.5 257.5 99.3042 1.3437 0.1828 0.0011 0.0015 1.3292 1.9938 2.58%
8 -22 251 98.9942 1.3742 0.1046 0.0007 0.0009 1.3590 1.2231 1.58%
9 -28.5 244.5 98.6771 1.4062 0.0578 0.0004 0.0006 1.3902 0.8341 1.08%
10 -35 238 98.3525 1.4399 0.0308 0.0002 0.0003 1.4231 0.4269 0.55%
MASA TOTAL 77.2858 100%
SOBRE LOS RESULTADOS DEL EJERCICIO, RESPONDA LAS SIGUIENTES
PREGUNTAS:
77.2858 𝑘𝑔
𝑃𝑟𝑜𝑓𝑢𝑛𝑑𝑖𝑑𝑎𝑑 𝑒𝑞𝑢𝑖𝑣𝑎𝑙𝑒𝑛𝑡𝑒 𝑑𝑒 𝑎𝑔𝑢𝑎 𝑙𝑖𝑞𝑢𝑖𝑑𝑎 =
𝑘𝑔
1000 𝑚3 ∗ 1𝑚2
A los 2 kilómetros a partir de la base encontramos más del 50% de cantidad de agua
precipitable.