Está en la página 1de 5

Doc. Nr. Rev.

CLIENT Rev. Date By Chkd. App. Pag.


0
LOCATION 1
TANK 2 1/2
UNIT 3
4
1 Rev.
2 ITEM NUMBER
3 NUMBER REQUIRED
4 TITLE
5 TYPE TANK
6 CASE
7 SERVICE
8 P&ID NO.
9
10 TEMPERATURE MÁX / NOR / MÍN ºF
PROCESS DATA

11
12 PRESSURE MÁX / NOR / MÍN in H2O
13
14 VAPOR PRESSURE psi(abs)
15 FLASH POINT ºF
16 NORMAL LIQUID LEVEL ft - in
17
18 CODE (DESIGN & CONSTRUCTION)
19 SPECIFICATIONS
20 TEMPERATURE ºF
21 PRESSURE in H2O
22 VACUMM in H2O
23 TEST PRESSURE in H2O
24 MAXIMUM LIQUID LEVEL ft - in
25 SPECIFIC GRAVITY
26 WELD INSPECTION BY RADIOGRAPHY
27 CORROSION ALLOWANCE in
DESIGN DATA

28 WORKING CAPACITY bbls


29 NET CAPACITY bbls
30 DIAMETER ft - in
31 HEIGHT ft - in
32 FLASHED GAS MAX / NOR / MIN MMSCFD
33 RATES FILLING - EMPTYING gpm
34
35 COIL:
36
37 HEATER:
38
39 ROOF TYPE:
40
41 ROOF SEAL TYPE:
42
43
44 SHELL: BOLTS (EXTERNAL):
45 BOTTOM: BOLTS (INTERNAL):
MATERIALS

46 ROOF: GASKETS:
47 NOZZLE NECKS: INTERNALS (PIPE):
48 FLANGES: INTERNALS (PLATE):
49 LINING:
50
51
52 NOTES:
53
54
55
56
57
58
59

557283362.xls PAGE 1
60

PROPRIETARY AND CONFIDENTIAL DATA

557283362.xls PAGE 1
Doc. Nr. Rev.

CLIENTE Rev. Fecha Por Rev. Apd. Pag.


0
UBICACION 1
TANQUE 2 2/2
UNIDAD 3
4
1 Rev.
2 NO. DE IDENTIFICACIÓN
3 CANTIDAD REQUERIDA
4 TÍTULO
5 TIPO TANQUE
6 CASO
7 SERVICIO
8 NO. DE DTI
9 REF. N° SERVICIO DIAM. RATING OBSERV. Rev.
10
11 BOQUILLAS
TANK SKETCH
12 A 1 ENTRADA
13 C 1 SALIDA
14 D 1 DRENAJE
15 F 1 GAS DE MANTO
16 H1 1 ESCOTILLA PESADA
17 H2 1 ESCOTILLA DE LADRÓN
18 U 1 CONECCION DE SERVICIOS V1
19 V1 1 VENTEO PRESION / VACÍO H2
H1

20 F

21
22
23 HHLL:

24 HLL:

25
26 CONEXIONES DE INSTRUMENTOS (NOTA 1)
27 H LLL:
28 LLLL:
29
C
30 A U
D
31
32
33
34
35
36
ID
37
38
39
40
41
42
43 COMPUERTAS/PASA HOMBRES (NOTA 2)
44
45
46
47
48
49
50
51
52
53 NOTAS: Rev.
54 1.- BOQUILLAS DE INSTRUMENTACION POR EL DEPARTAMENTO DE INSTRUMENTACION.
55 2.- COMPUERTAS/PASA HOMBRES POR EL DEPARTAMENTO DE MECANICA.
56
57
58
59

557283362.xls PAGE 2 - TANQUE


60

DATOS PROPIETARIOS Y CONFIDENCIALES

557283362.xls PAGE 2 - TANQUE


Doc. Nr. Rev.

CLIENTE Rev. Fecha Por Rev. Apd. Pag.


0
UBICACION 1
FOSA 2 2/2
UNIDAD 3
4
1 Rev.
2 NO. DE IDENTIFICACIÓN
3 CANTIDAD REQUERIDA
4 TITULO
5 TIPO FOSA
6 CASO
7 SERVICIO
8 NO. DE DTI
9 REF. N° SERVICIO DIAM. RATING OBSERV. Rev.
10
11 BOQUILLAS
12 N1
13 N2
14 N3 VISTA LATERAL
15 N4
16 N5
17 N6
18 N7
VACUUM TRUCK CONNECTION VACUUM TRUCK CONNECTION
19 V N8
20 H1
N4
21 N8
N3 HLL=
22 N1
LLL=
23 CONEXIONES DE INSTRUMENTOS (NOTA 1)
24
25
26
27
28
29
30 COMPUERTAS/PASA HOMBRES (NOTA 2)
31
32
33
34
35
36
37 VISTA AEREA
38
39
VACUUM TRUCK CONNECTION
40
41
42
43
VACUUM TRUCK CONNECTION
44
45 LINE FROM KO DRUM
46
TANK OVERFLOW
47
48 DRAIN HEADER CONCRETE BASE
49
50
51
52
53 NOTAS: Rev.
54 1.- BOQUILLAS DE INSTRUMENTACION POR EL DEPARTAMENTO DE INSTRUMENTACION.
55 2.- COMPUERTAS/PASA HOMBRES POR EL DEPARTAMENTO DE MECANICA.
56
57
58
59
60

DATOS PROPIETARIOS Y CONFIDENCIALES


557283362.xls PAGE 2 - FOSA