CALCULO DEL NUMERO DE LOTES

MANZANA LOTE/MANZANA # MANZANA LOTES


A 10 1 10
B 9 1 9
C 9 1 9
D 11 1 11
E 7 1 7
F 8 1 8
G 8 1 8
H 18 1 18
I 18 1 18
LOTES TOTALES 98

CALCULO DE LA DENSIDAD

consumo = dotacion

dotacion= 250.00 l/hab/dia 2000 l/conex/dia


densidad=
consumo= 60.00 m3/conex/mes 250.00 l/hab/dia
consumo= 60000.00 l/conex/mes
consumo= 2000.00 l/conex/dia
densidad= 8.00 Hab/Conexion

CALCULO DE LA POBLACION INICIAL, CAUDAL PROMEDIO Y CAUDAL MAXIMO HORARIO

P0= 784 HAB


TASA DE CRECIMIENTO= 0.009
F.R= 0.80
K2= 1.96
DESAGUE
CONSUMO SUJETO DE
AÑO POBLACION DENSIDAD # LOTES DOTACION PROMEDIO CONSUMO CONSUMO
MAX HOR
POR AÑO (DOMESTICO)
0 784 8.00 Hab/Conexion 98 250.00 l/hab/dia 2.27 l/s 4.446 l/s 3.56 l/s
1 792 8.00 Hab/Conexion 99 250.00 l/hab/dia 2.29 l/s 4.49 l/s 3.59 l/s
2 799 8.00 Hab/Conexion 100 250.00 l/hab/dia 2.31 l/s 4.53 l/s 3.63 l/s
3 806 8.00 Hab/Conexion 101 250.00 l/hab/dia 2.33 l/s 4.57 l/s 3.66 l/s
4 813 8.00 Hab/Conexion 102 250.00 l/hab/dia 2.35 l/s 4.61 l/s 3.69 l/s
5 820 8.00 Hab/Conexion 103 250.00 l/hab/dia 2.37 l/s 4.65 l/s 3.72 l/s
6 828 8.00 Hab/Conexion 104 250.00 l/hab/dia 2.40 l/s 4.70 l/s 3.76 l/s
7 835 8.00 Hab/Conexion 105 250.00 l/hab/dia 2.42 l/s 4.74 l/s 3.79 l/s
8 843 8.00 Hab/Conexion 106 250.00 l/hab/dia 2.44 l/s 4.78 l/s 3.82 l/s
9 850 8.00 Hab/Conexion 107 250.00 l/hab/dia 2.46 l/s 4.82 l/s 3.86 l/s
10 858 8.00 Hab/Conexion 108 250.00 l/hab/dia 2.48 l/s 4.87 l/s 3.89 l/s
11 866 8.00 Hab/Conexion 109 250.00 l/hab/dia 2.51 l/s 4.91 l/s 3.93 l/s
12 873 8.00 Hab/Conexion 110 250.00 l/hab/dia 2.53 l/s 4.95 l/s 3.96 l/s
13 881 8.00 Hab/Conexion 111 250.00 l/hab/dia 2.55 l/s 5.00 l/s 4.00 l/s
14 889 8.00 Hab/Conexion 112 250.00 l/hab/dia 2.57 l/s 5.04 l/s 4.03 l/s
15 897 8.00 Hab/Conexion 113 250.00 l/hab/dia 2.60 l/s 5.09 l/s 4.07 l/s
16 905 8.00 Hab/Conexion 114 250.00 l/hab/dia 2.62 l/s 5.13 l/s 4.11 l/s
17 913 8.00 Hab/Conexion 115 250.00 l/hab/dia 2.64 l/s 5.18 l/s 4.14 l/s
18 922 8.00 Hab/Conexion 116 250.00 l/hab/dia 2.67 l/s 5.23 l/s 4.18 l/s
19 930 8.00 Hab/Conexion 117 250.00 l/hab/dia 2.69 l/s 5.27 l/s 4.22 l/s
20 938 8.00 Hab/Conexion 118 250.00 l/hab/dia 2.71 l/s 5.32 l/s 4.25574 l/s
CALCULO DEL CAUDAL DE DISEÑO intensidad= 85.00 l/s/ha
CONEXIÓN EQUIVALENTE POR LOTE = 1.2040816326531 coeficiente de impermeabilidad= 0.43

CAUDAL POR CONEXIÓN AL AÑO 20 = 0.04343 L/S CI= 20000.00 L/KM/DIA = 0.23148 L/KM/SEG AREA DE INFLUENCIA= 32408.18 m2 = 3.24 Ha

TRAMO Nº CONEXIONES Nº CONEXIONES SUJETO DE CONSUMO LONGITUD COEFICIENTE DE CAUDAL DE CAUDAL DE


% C I A
AÑO "0" AÑO "20" (m) INFILTRACION INFILTRACION COEXIONES ERRADAS
BZ BZ DOMESTICO INSDUSTRIAL
1 2 9 11 0.39083 L/S 76.44 0.000231 l/seg/m 0.01769 L/S 2% 0.43 85.00 l/s/ha 3293.2898 0.24074 L/S
2 3 15 18 0.65139 L/S 70.29 0.000231 l/seg/m 0.01627 L/S 2% 0.43 85.00 l/s/ha 4086.6558 0.29873 L/S
3 4 0 0 0.00000 L/S 17.25 0.000231 l/seg/m 0.00399 L/S 2% 0.43 85.00 l/s/ha 1206.3648 0.08819 L/S
4 5 14 17 0.60796 L/S 68.80 0.000231 l/seg/m 0.01593 L/S 2% 0.43 85.00 l/s/ha 4215.9197 0.30818 L/S
5 6 17 20 0.73824 L/S 69.23 0.000231 l/seg/m 0.01603 L/S 2% 0.43 85.00 l/s/ha 3353.4180 0.24513 L/S
1 7 11 13 0.47769 L/S 95.570 0.000231 l/seg/m 0.02212 L/S 2% 0.43 85.00 l/s/ha 4034.566 0.29493 L/S
7 8 11 13 0.47769 L/S 70 L/S 65.117 0.000231 l/seg/m 0.01507 L/S 2% 0.43 85.00 l/s/ha 3639.829 0.26607 L/S
8 9 0 0 0.00000 L/S 30.000 0.000231 l/seg/m 0.00694 L/S 2% 0.43 85.00 l/s/ha 1891.2441 0.13825 L/S
9 6 13 16 0.56454 L/S 63.625 0.000231 l/seg/m 0.01473 L/S 2% 0.43 85.00 l/s/ha 3292.7084 0.24070 L/S
2 7 8 10 0.34741 L/S 69.142 0.000231 l/seg/m 0.01601 L/S 2% 0.43 85.00 l/s/ha 2018.3149 0.14754 L/S
6 DESCARGA 0 0.00000 L/S 21.370 0.000231 l/seg/m 0.00495 L/S 2% 0.43 85.00 l/s/ha 1375.8681 0.10058 L/S
CONEXIOMES= 98 118 4.25574 L/S 0.14973 L/S 32408.18 2.36904 L/S

Q MAX Q PROM Q MIN


SIFON
m3/s m3/s m3/s
SIFON 01 0.00256 0.00120 0.00067
SIFON 02 0.13120 0.10757 0.08891
CAUDAL DE DISEÑO

0.649 L/S
0.966 L/S
0.092 L/S
0.932 L/S
0.999 L/S
0.795 L/S
70.759 L/S
0.145 L/S
0.820 L/S
0.511 L/S
0.106 L/S
76.77451 L/S
CALCULO HIDRÁULICO PARA EL SISTEMA DE ALCANTARILLADO SANITARIO POR EL CRITERIO DE TENSIÓN TRA
Proyecto: SOLUCIONARIO DE PTRACTICA CALIFICADA Nº01

sMin=1.00 Pa DMin= 200 mm VMax= 5 m/s y/D Max= 0.75


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 23 24 25 26 27 28 29 30

N° COLECTOR
Q. de Q. Q. de Descarga Cota de Terreno Profundidad Cota de Fondo
DE BUZON CONTRIBUYENTE
Colector

Nombre
Tramo

Long. Aguas Del Aguas en el Dh S D Teo D Com Q0 A0 V0 P0 R0


n
(m) Arriba Tramo Abajo Colector (m) (m/m) (mm)
Arriba

(mm) (m3/s) (m2) (m/s) (m) (m)


Abajo

A. Arriba A. Abajo A. Arriba A. Abajo A. Arriba A. Abajo


N° m /s
3
(m3/s) (m3/s) (m3/s) N° (m) (m) (m) (m) (m) (m)

1 VI 1 2 76.44 - 0.0000 0.00 0.0015 0.00150 1V 185.00 185.50 1.00 2.00 184.00 183.50 0.50 0.0065 0.009 59 200 0.0384 0.0314 1.2209 0.6283 0.0500
1 V 2 3 70.29 - 0.0000 0.00150 0.000966 0.00247 1 IV 185.50 184.10 2.00 1.20 183.50 182.90 0.60 0.0085 0.009 68 200 0.0438 0.0314 1.3947 0.6283 0.0500
1 IV 3 4 17.25 - 0.0000 0.00247 0.000092 0.00256 1 III 184.10 184.00 1.20 1.80 182.90 182.20 0.70 0.0406 0.009
1 III 4 5 68.80 - 0.0000 0.00256 0.000932 0.00349 1 II 184.00 184.15 1.80 2.65 182.20 181.50 0.70 0.0102 0.009 75 200 0.0479 0.0314 1.5232 0.6283 0.0500
1 II 5 6 69.23 - 0.0000 0.00349 0.000999 0.00449 1I 184.15 183.70 2.65 2.45 181.50 181.25 0.25 0.0036 0.009 100 200 0.0285 0.0314 0.9071 0.6283 0.05
1 I 6 Des 21.37 - 0.1320 0.00449 0.000106 0.13661 183.70 184.00 2.45 2.85 181.25 181.15 0.10 0.0047 0.009 342 400 0.206 0.1257 1.6392 1.2566 0.1
2 IV 1 7 95.57 - 0.0580 0.00000 0.000795 0.05879 2 III 185.00 185.80 1.50 2.70 183.50 183.10 0.40 0.0042 0.009 254 315 0.103 0.0779 1.322 0.9896 0.0788
2 III 7 8 65.12 - 0.0015 0.05879 0.070759 0.13105 2 II 185.80 184.20 2.70 1.35 183.10 182.85 0.25 0.0038 0.009 349 400 0.1866 0.1257 1.4847 1.2566 0.1
2 II 8 9 30.00 - 0.0000 0.13105 0.000145 0.13120 2I 184.20 184.10 1.35 1.62 182.85 182.48 0.37 0.0125 0.009
2 I 9 6 63.63 - 0.0000 0.13120 0.000820 0.13202 1I 184.10 183.70 1.62 1.45 182.48 182.25 0.23 0.0036 0.009 355 400 0.1796 0.1257 1.4291 1.2566 0.1
3 I 2 7 69.14 - 0.0000 0.0000 0.0015 0.00150 2 III 185.50 185.80 1.00 1.70 184.50 184.1 0.40 0.0058 0.009 60 200 0.0361 0.0314 1.1482 0.6283 0.05

X I W 1 83.50 - 0.0000 0.0000 0.0580 0.05800 2 IV 184.80 185.00 1.20 1.50 183.60 183.5 0.10 0.0012 0.009 320 355 0.0758 0.099 0.7658 1.1153 0.0888
CRITERIO DE TENSIÓN TRACTIVA MEDIA

31 32 33 34 35 36 37 38 39 40

TABLA Condiciones para que el calculo Hidraulico sea CORRECTO


y Vf s RH VCritica
y/D
(m) (m/s) (Pa) (m) (m/s) Verificacion de Verificacion de Verificacion de Verificacion de Analisis de la "y" cuando
Qr/Q0 Vr/V0 yr/D0 Rr/R0
D>160mm y < 0.75D Vf < 5.0 s>1.0Pa Vf > VCritica

0.04 0.4270 0.1650 0.4100 0.033 0.16500 0.5213 1.315 0.021 2.69 Correcto Correcto Correcto Correcto No Analizar y -
0.06 0.4730 0.1960 0.4810 0.039 0.19600 0.6597 2.014 0.024 2.91 Correcto Correcto Correcto Correcto No Analizar y -

0.07 0.492 0.21 0.51 0.042 0.21000 0.7494 2.547 0.026 3.00 Correcto Correcto Correcto Correcto No Analizar y -
0.16 0.613 0.308 0.704 0.0616 0.308 0.5561 1.247 0.035 3.5258 Correcto Correcto Correcto Correcto No Analizar y -
0.66 0.927 0.666 1.16 0.2664 0.666 1.5195 5.325 0.116 6.4005 Correcto Correcto Correcto Correcto No Analizar y -
0.57 0.885 0.608 1.125 0.19152 0.608 1.17 3.6376 0.089 5.5935 Correcto Correcto Correcto Correcto No Analizar y -
0.70 0.945 0.692 1.175 0.2768 0.692 1.4031 4.4254 0.118 6.4418 Correcto Correcto Correcto Correcto No Analizar y -

0.74 0.961 0.719 1.188 0.2876 0.719 1.3734 4.1453 0.119 6.4773 Correcto Correcto Correcto Correcto No Analizar y -
0.04 0.427 0.165 0.41 0.033 0.165 0.4903 1.1634 0.021 2.6907 Correcto Correcto Correcto Correcto No Analizar y -

0.77 0.972 0.738 1.195 0.26199 0.738 0.7444 1.246 0.106 6.12 Correcto Correcto Correcto Correcto No Analizar y -
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

TABLA
CAUDAL D Com Q0 A0 V0 P0 R0 y Vf E RH VCritica
SIFON y/D
(m3/s) (mm) (m3/s) (m2) (m/s) (m) (m) (m) (m/s) (m) (m) (m/s)
Qr/Q0 Vr/V0 yr/D0 Rr/R0

CAUDAL MAXIMO 0.00256 200 0.0438 0.0314 1.3947 0.6283 0.0500 0.06 0.4730 0.1960 0.4810 0.039 0.19600 0.660 0.061 0.024 2.91
1 CAUDAL PROMEDIO 0.00120 200 0.0438 0.0314 1.3947 0.6283 0.0500 0.03 0.4000 0.1480 0.3700 0.030 0.14800 0.558 0.045 0.019 2.56
CAUDAL MINIMO 0.00067 200 0.0438 0.0314 1.3947 0.6283 0.0500 0.02 0.3620 0.1240 0.3150 0.025 0.12400 0.505 0.038 0.016 2.36

Q1= 0.00067
Q2= 0.00053
Q3= 0.00136

1 2 3 4 5 6 7 8 9 10

CAUDAL V D Teo D Com Vf L hi EQUIVALENCIAS DE Ø


SIFON n
(m3/s) (m/s) (m) (m) (m/s) (m) (m) EN mm. A PULGADAS
Q1= 0.00067 1.20 0.027 0.032 0.83 0.009 18.26 0.70 Ø 20 mm 1/2″
1 Q2= 0.00053 1.20 0.024 0.032 0.66 0.009 18.26 0.45 Ø 25mm 3/4″
Q3= 0.00136 1.20 0.038 0.050 0.69 0.009 18.26 0.29 Ø 32 mm 1″
Ø 40 mm 1 1/4″
0.70 Ø 50 mm 1 1/2″
cota de batea entrada 182.70 Ø 63 mm 2″
cota de bateasalida 182.00 Ø 75 mm 2 1/2″
Ø 90 mm 3″
Ø 110 mm 4″
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

TABLA
CAUDAL D Com Q0 A0 V0 P0 R0 y Vf E RH VCritica
SIFON y/D
(m3/s) (mm) (m3/s) (m2) (m/s) (m) (m) (m) (m/s) (m) (m) (m/s)
Qr/Q0 Vr/V0 yr/D0 Rr/R0

CAUDAL MAXIMO 0.13120 400 0.1866 0.1257 1.4847 1.2566 0.1000 0.70 0.98 0.75 1.2 0.300 0.75000 1.4551 0.408 0.120 6.51
2 CAUDAL PROMEDIO 0.10757 400 0.1866 0.1257 1.4847 1.2566 0.1000 0.58 0.9180 0.6510 1.1510 0.260 0.65100 1.363 0.355 0.115 6.38
CAUDAL MINIMO 0.08891 400 0.1866 0.1257 1.4847 1.2566 0.1000 0.48 0.8650 0.5820 1.1000 0.233 0.58200 1.2843 0.317 0.110 6.23

Q1= 0.089
Q2= 0.019
Q3= 0.024

1 2 3 4 5 6 7 8 9 10

CAUDAL V D Teo D Com Vf L hi


SIFON n
(m3/s) (m/s) (m) (m) (m/s) (m) (m)
Q1= 0.08891 1.20 0.31 0.315 1.14 0.009 29.348 0.22
2 Q2= 0.01866 1.20 0.14 0.160 0.93 0.009 29.348 0.23
Q3= 0.02363 1.20 0.16 0.160 1.18 0.009 29.348 0.37

0.37
cota de batea entrada 182.45