Ubicacion y arreglo Fluidos DTeff DTml T1 T2 t1 t2 F R P Ub Fluidos Arreglo °C °C °C °C °C °C Cal Carcaza Contracorriente 70.8 80.8 0.88 200.0 90.0 40.0 77.9 2.90 0.24
Ur Atransf D2 Pitch L Are 1 T BWG Arreglo Ntaprox Ntprop Npt W/m2.°C m2 in in ft m2 300.0 7.1E+01 0.75 0.9375 14 Triangular 16.4042 3.0E-01 238 360 4
Datos geometricos del intercambiador
Npc Dc B % corte D1 Deq Tpo Cabezal in in in mm 1 23.25 5 15 %C 0.584 13.771 Flotante
Coeficiente de Transferencia de Calor Lado tubos
Aft Gt qt ut hi DPt Ret Jt Nut L/d1 jft m2 lb/ft2 h [m3/s] [m/s] W/m2.°C bar 0.0156 9.22E+05 0.0237 1.525 5.8E+03 27.66 1.0E+02 914 3.4E+02 5.52E-03 0.663
Coeficiente de Transferencia de calor Lado carcaza
Afc Gc qc ut ho DPt Rec Jc Nuc Dc/Deq jfc L/B m2 lb/ft2 h [m3/s] [m/s] W/m2.°C bar 0.015 2.73E+05 6.775E-03 0.452 1.186E+04 72.86 1.5E+02 1399.5 4.3E+01 6.90E-02 3.9E+01 0.779