Documentos de Académico
Documentos de Profesional
Documentos de Cultura
DATOS TECNICOS
Instrumento clase esc max error abs δv=(Ɛ%/100%)*esc max
voltimetro Ɛ%= 0.25 % 200 [V] 0.5 [V]
Electrómetro Ɛ%= 1.25 % 20 [Kv/m] 0.25 [Kv/m] δe=(Ɛ%/100%)*esc max
Regla Ɛ%= 0.1 %
Limites De Medida
VL=10*δv VL= 5 [V]
EL=10*δe EL= 2.5 [Kv/m]
REGISTRO DE DATOS
N V±δv[V] E±δe[Kv/m]
1 76.5 ± 0.5 1.50 ± 0.25
2 85.2 ± 0.5 1.70 ± 0.25
3 88.8 ± 0.5 1.76 ± 0.25
4 101.2 ± 0.5 2.00 ± 0.25
5 115.0 ± 0.5 2.29 ± 0.25
6 121.7 ± 0.5 2.42 ± 0.25
7 131.9 ± 0.5 2.61 ± 0.25
8 143.9 ± 0.5 2.85 ± 0.25
9 150.7 ± 0.5 2.99 ± 0.25
10 168.3 ± 0.5 3.35 ± 0.25
11 180.0 ± 0.5 3.57 ± 0.25
12 190.5 ± 0.5 3.78 ± 0.25
N V±δv[V] E±δe[v/m]
1 76.5 ± 0.5 1500 ± 250
2 85.2 ± 0.5 1700 ± 250
3 88.8 ± 0.5 1760 ± 250
4 101.2 ± 0.5 2000 ± 250
5 115.0 ± 0.5 2290 ± 250
6 121.7 ± 0.5 2420 ± 250
7 131.9 ± 0.5 2610 ± 250
8 143.9 ± 0.5 2850 ± 250
9 150.7 ± 0.5 2990 ± 250
10 168.3 ± 0.5 3350 ± 250
11 180.0 ± 0.5 3570 ± 250
12 190.5 ± 0.5 3780 ± 250
PROCESAMIENTO DE DATOS
3500
V E
3000 0 0
2500 76.5 1530
E
85.2 1704
2000
88.8 1776
1500 101.2 2024
1000 115.0 2300
121.7 2434
500
131.9 2638
0 143.9 2878
0 50 100 150 200 250
150.7 3014
V 168.3 3366
180.0 3600
190.5 3810
2 Calculo o determinacion de la distancia
parametros
ecuacion de la potencia
b= 1.0048
a= 2.9639
= 2.9639 + 1.0048 * x
8.4000
8.2000
8.0000
7.8000
7.6000
y
7.4000
7.2000
7.0000
6.8000
4.200 4.400 4.600 4.800 5.000 5.200 5.400
x
Desviación Estándarde Sy
Sy= 0.004466938
Sxx= 1.013417247
Desviación Estándar de A y B
A= 0.05162
0.052
Calculamos:
σA 0.001106486
= 0.00443727
Coeficiente de confianza
Grados de Libertad
10 3.169
β= 1.005 ± 0.014
0.014061708
prueba de hipotesis
para α
para β
H0: β= 1 0.3431125
H1: β≠ 1
Reemplazando:
1.005
Y= X
0.052
3500
V E
3000
76.5 1302
2500 85.2 1450.8
88.8 1512.38
2000
101.2 1724.66
E