Está en la página 1de 5
Barton’ FCX-A Series! Gauge Pressure Transmitter, Specification Sheet ‘The FCX-A pressure transmitter accurately meesures gauge pressure and transmits a proportional 4-20 mA signal. The transmiter incorporates silicon sensor and micro-processor fechnologies resulting in exceptional performance and functionality. An optionat Communication module converts the FH series traditional offering to the FK series smart transmitter that communicates via FCX standard or HART protocol. [Functional Specifications Types: Mode! FHG: 4-20 mA traditional gauge pressure transmitter Model FKG: 4-20 mA smart gauge pressure transmitter Servico: Liquid, Gas, Vapor Upper & Over Range Limits: Upper Rango Limit (URL) | Over Range Limit Model (Manat epar) _| esi [ipa [bar [psi aT bar Fer 9 [64 _f 06a [148 _| 7,000 [70 [soe [sor sao [as FEDS ass | 3.000 | 30 | 7.900] 9,000 [20 Feo | TSO | 16,000] 100 | 2.170 | 78,000 | 150, Feo 7 woo [50.050 500] 10,600] 75,000] 750, ‘Vacuum Limit: Silicone oil fil: See Figure 1 on next page Fluorinated oil fil: 9.5 psi abs (66 kPa abs) (.66 bar abs) Output Signal: Model FHG; 4-20 mA DC 2-wire, linear signal Model FKG: 4-20 mA DC 2-wire, with digital signal superimposed on the anaiog ouipst. 210% URL. ‘Minimum Span: 21% URL (22.5% recommended) Power Supply: 11V to 45V DO at transmitter terminals 44V fo 32V DC for units with optional arrestor installed Hazardous Area Classificatior ‘Authorities Flameproof__| intrinsically Safe [ Type N Non incendive BASEEFA, Ex ds IC 15,76 = EXN ITS, CENELEC = EEX ia Ie 14, 15 = Factory Mutval | Glass ini Diy + [Class iT Div 1 Glass Til Dv 2 Grp B thru G Gip A thru F Grp A thru G CEA Class Vin iv. 1 | Class Lh Div. 7 = Grp C thru G. Grp AthnuG Ris Ex ds IIB + HT4 BaG = FHOFKG-4 ‘Ordor No. $1545, {© Copyright 1997, 1TT Barton, @ unit of ITT Industries, ne. Functional Specifications (contin Load Limitations: (see figure below right): Silicone ail (Code ¥, G, N) Silicone oif 101 (10107 ey 5 20 ia (200) £ ed ax (40) o£ 2? 1ON6.1 = W) @ 105 Povervottage Note: For commurication with FRW, HanckHeld Communicator minimum of 250% requirect. 40-15 60 35100 Process terpperature (°C) Fig. 1 Relation between process temperature and operating pressure Zero/Span Adjustment: Model FHG: Zero and span are adjustable via a single external adjustment screw controlled by a MODE SWITCH found on the main board, The user sets the MODE SWITCH to either ZERO or SPAN the calibration function desired, An INHIBIT mode is selectable via MODE SWITCH, and serves to disable the external screw to prevent tampering. Model FKG: Zero and span are adjustable via the handheld communicator. Zero is also adjustable via the external screw, which can be disabied by the user to prevent tampering. Damping: Model FHG: Selectable as 0, 0.3, 1.2, 4.8 or 19.2 seconds via DAMP SWITCH Model FKG: Selectable between 0 to'38.4 seconds via HHC Zero Elevation Suppression: -100% to + 100% of URL (zero plus span not to exosed URL) NormalfReverse Action; —_Field selectable via jumper pin (FHG) or HHC (FKG) Indication: Analog indicator or 5-digit LCD meter Direction can be specified as ‘output hold”, 3.8 mA, or 21.6 mA. Factory standard for FHG is output hold. The burnout direction for the FKG transmitter is selectable via the handheld. Burnout Directio Functional Spe Loop-check Output: Model FHG: The transmitter can output a constant of 4 mA, 12 mA, or 20 mA selectable via the MODE SWITCH. Model FKG: The transmitter can be configured to provide a constant current between 3.8 mA and 21.6 mA via the HHC. ‘Temperature Limits: Ambient:* Without LCD: -40°F to +185°F (-40°C to +85°C) With LCD: -4°F to +176°F (-20°C to +80°C) Arrestor: -40°F to + 140°F (-40°C to +60°C) Fluorinated oil fill; +14°F to +140°F {-10°C to +60°C) “For explosion proof, flameproof or intrinsically safe units, ambient temperature must be within the limits specified in each standard Process: Silicone Fill: -AO°F to +212°F (-40°C to +100°C) Fluorinated oil fill: -4°F to +176°F (-20°C to +80°C) -40°F to +194°F (-40°C to +80°C) Storag Humidity: 0-100% relative humidity Communications (Model FKG only) Trems Display [Set] Communication: Tag v v ‘avent I i Model No, v WT] Model FKG only. The adjacent information ‘Serial No. Tv =] can be remotely displayed or configured Engineering Unk y ——| using the FXW handheld or sultable HART Rage ae + “1 communication device. Measuring range yf v1 Barton's HHC must be version 5.0 Damping _ v ¥ | (minimum) or FXW_____ 1-2 to use the ‘Output mode v v—| communication functions. Previous versions Burnoul_ direction v v—]| can be upgraded and will be compatible [Adjustment v v__| with both FCX and FCX AC series. Output adjust, = v Data v = FHG series transmitters can be upgraded in ‘Self diagnosis Vv IT] the field to the FKG smart model, via the Printer = — addition of a plug-in communic Exiernal switch lock v v_] module. Transmitter display v v Physical Specifications Electrical connections: North American std: 1/2"-14 NPT European std: M20 x 1.5. Others available: G1/2 or Pg 13.5 as specified Process connections: Standard: 1/4"-18 NPT Others available: Rc 1/4. Also see process adapters in options section of this specification, Process-wetted materials: Material Process | Diaphragm | Wetted Sensor | Vent/Drain (7th) Code Cover: bouy Vv. 316 SST, Siel SST 316 SST 316 SST H 316 SST Hastelloy-C Hastelloy-C 316 SST, M 316 SST Monel ‘Monel 316 SST, T 316 SST Tantalum Tantalum, 316 SST, B Hastelloy-C Hastelloy-C Hastelloy-C Hastelloy-C te Monel Monel Monel Monet uF Tantalum Tantalum Tantalum Tantalum ~ Note: (*) Process covers are lined with specified material. Some materials are restricted to specific ranges. See order codes for details. Sensor O-rings: Standard: Viton Optional: Teflon Non-wetted parts materials: Electronics housing: Standard: Low copper die cast aluminum alloy finished with double coating of epoxy/polyurethane Optional: 316 stainless steel Bolts and nuts: Standard: Cr-Mo alloy (NACE Class 3) Optional**: ASTM A193 B7M bolt with A194 2HM nut* ‘ASTM A320 L7M bolt with A194 2HM nut * 304 stainless steel” 630 (17-4pH) stainless steel (for range code 05) ‘Note: 1450 psi, 100 bar, 10 MPa max “Note: NACE Ciass 1 Fill fluid: Standard: Silicone oil Optional: Fluorinated oll (Daifoil) Mounting bracket: Standard: Epoxy coated carbon steel Optional: 304 stainless steel Environmental protection: IEC IP67 and NEMA 4x Mounting: Direct process or brackets for 2° (60.Smm) pipe or wall mour Approximately 7.5 Ibs (3.4 kg) without options ‘Add: 1.1 Ibs (0.5 kg) for mounting bracket 1,7 Ibs (0.8 kg) for indicator 9.9 Ibs (4.5 kg) for stainless stee! housing option Performance Specifications Accuracy: (including linearity, hysteresis, and repeatabiley) +# 0.1% of calibrated span for spans >10% URL. +0.075% (digital mode only) available upon request. For spans <10% URL [FKG only] use the following: 4fo 06 + 005 2 uit) % of span [FKG only} ‘Stability: 40.1% of upper range limit (URL) for 6 months, Temperature effect: Per 131°F (55°C) change between ~40°F and 185°F (-40°C and 85°C) URL Zero shift: {avon 119FF 6ST) om, Total effect: {om + 0.96 a ‘span, Note: Double the effect for the (7th) material codes H, M, T, B, L, and U. Overrange effect: Zero shifl: # 0.2% of URL for any overrange to over range limit ‘Supply voltage offect: <0.05% of calibrated span per 10V REI offect: <0.2% of URL for frequencies between 20 to 1,000 MHz and a field strength of 10V per meter when the electronics cover is on.(Classification: 2-abe: 0.2% span per SAMA PMC 33.1) Time constant is 0.2 seconds Step Response: Dead Time approximates 0.3 seconds without electrical damping Zero shift is less than 0.4" w.c. (0.1 kPa) (1 mbar) for a 10° tlt in any plane. This eror can be corrected by adjusting zero. Double the effect for fluorinated oil fill. No effect on span. Mounting effe Dielectric strength: 500V AC, 50/60 Hz 1 minute, between circuit and earth. Insulation resistance: More than 100 MQ at 500 VDC. Turn-on time: 4 seconds

También podría gustarte