Está en la página 1de 45

Eligir un inversor:

Sunstring 5000

PX 310/72
Eligir un generador:
3 7 ... 11 Revisión de la orientación 100.00%
ristras modulos Total P / kW ISC IMPP UMPP UOC

2 8 16 4.960 17.6 16.7 297.6 372.8

0 0 0 0.000 0 0 0 0

0 0 0 0.000 0 0 0 0

0 0 0 0.000 0 0 0 0

0 0 0 0.000 0 0 0 0

0 0 0 0.000 0 0 0 0

0 0 0 0.000 0 0 0 0

0 0 0 0.000 0 0 0 0

0 0 0 0.000 0 0 0 0

0 0 0 0.000 0 0 0 0

0 0 0 0.000 0 0 0 0

0 0 0 0.000 0 0 0 0

0 0 0 0.000 0 0 0 0

0 0 0 0.000 0 0 0 0

0 0 0 0.000 0 0 0 0
16 4.96000
Prestación máx DC min 200 rendimiento-DC máx
max 600 26.5 92……98%
5.060 Estado U I P

solo para P / kW ISC IMPP UMPP UOC


Entrada
manual: 250 8.00 5.80 20.00 24.00
100.00%
Umin(75°) Umax(-10°) <95% >105% tensión corriente CosPhi=1
232.36 418.47 OK OK O.K. O.K. 99.40%

0.00 0.00

0.00 0.00

0.00 0.00

0.00 0.00

0.00 0.00

0.00 0.00

0.00 0.00

0.00 0.00

0.00 0.00

0.00 0.00

0.00 0.00

0.00 0.00

0.00 0.00

0.00 0.00
1.00
CosPhi
99.40%
Colocación de los módulos
Longitud 20.00
PX 310/72
Ancho 12.00 m

en batería uno encima del otro Σ eficacia


19 6 114 35.34

horizontal
en batería uno encima del otro
[P]=kWp
SA 90 15.21 9.23 135 12.15
SA 95 15.21 9.23 135 12.83
SA 100 15.21 9.23 135 13.50
SA 105 15.21 9.23 135 14.18
SA 110 15.21 9.23 135 14.85
PX 1006 29.63 8.11 232 23.20
PX 1106 29.63 8.11 232 25.52
PX 1156 29.63 8.11 232 26.68
PX 1206 29.63 8.11 232 27.84
PX 1256 29.63 8.11 232 29.00
PX 1306 29.63 8.11 232 30.16
PX 1356 29.63 8.11 232 31.32
PX 1406 29.63 8.11 232 32.48
PX 1506 29.63 8.11 232 34.80
PX 1606 29.63 8.11 232 37.12
PX 190/50 24.13 7.41 168 31.92
PX 195/50 24.13 7.41 168 32.76
PX 200/50 24.13 7.41 168 33.60
PX 205/50 24.13 7.41 168 34.44
PX 210/50 24.13 7.41 168 35.28
PX 200/60 19.76 7.24 133 26.60
PX 205/60 19.76 7.24 133 27.27
PX 210/60 19.76 7.24 133 27.93
PX 215/60 19.80 7.24 133 28.60
PX 220/60 19.76 7.24 133 29.26
PX 225/60 19.76 7.24 133 29.93
PX 230/60 19.76 7.24 133 30.59
PX 235/60 19.76 7.24 133 31.26
PX 240/60 19.76 7.24 133 31.92
PX 245/60 19.76 7.24 133 32.59
PX 250/60 19.76 7.24 133 33.25
PX 255/60 19.76 7.24 133 33.92
PX 260/60 19.76 7.24 133 34.58
PX 270/60 19.76 7.24 133 35.91
PX 270/72 19.76 6.08 114 30.78
PX 275/72 19.76 6.08 114 31.35
PX 280/72 19.76 6.08 114 31.92
PX 285/72 19.76 6.08 114 32.49
PX 290/72 19.76 6.08 114 33.06
PX 295/72 19.76 6.08 114 33.63
PX 300/72 19.76 6.08 114 34.20
PX 305/72 19.76 6.08 114 34.77
PX 310/72 19.76 6.08 114 35.34
PX 315/72 19.76 6.08 114 35.91
PX 320/72 19.76 6.08 114 36.48
PX 325/72 19.76 6.08 114 37.05
AS 1206 29.63 8.11 232 27.84
AS 1256 29.63 8.11 232 29.00
AS 1306 29.63 8.11 232 30.16
AS 1356 29.63 8.11 232 31.32
AS 1406 29.63 8.11 232 32.48
AS 1506 29.63 8.11 232 34.80
AS 175/50 24.13 7.41 168 29.40
AS 180/50 24.13 7.41 168 30.24
AS 185/50 24.13 7.41 168 31.08
AS 190/50 24.13 7.41 168 31.92
AS 195/50 24.13 7.41 168 32.76
AS 200/50 24.13 7.41 168 33.60
AS 205/50 24.13 7.41 168 34.44
AS 210/50 24.13 7.41 168 35.28
AS 190/60 19.76 7.24 133 25.27
AS 200/60 19.76 7.24 133 26.60
AS 205/60 19.76 7.24 133 27.27
AS 210/60 19.76 7.24 133 27.93
AS 215/60 19.76 7.24 133 28.60
AS 220/60 19.76 7.24 133 29.26
AS 225/60 19.76 7.24 133 29.93
AS 230/60 19.76 7.24 133 30.59
AS 235/60 19.76 7.24 133 31.26
AS 240/60 19.76 7.24 133 31.92
AS 245/60 19.76 7.24 133 32.59
AS 250/60 19.76 7.24 133 33.25
AS 260/60 19.76 7.24 133 34.58
AS 290/60 19.76 7.24 133 38.57
AS 270/72 19.76 6.08 114 30.78
AS 280/72 19.76 6.08 114 31.92
AS 285/72 19.76 6.08 114 32.49
AS 290772 19.76 6.08 114 33.06
AS 295/72 19.76 6.08 114 33.63
AS 300/72 19.76 6.08 114 34.20
AS 305/72 19.76 6.08 114 34.77
AS 310/72 19.76 6.08 114 35.34
AS 315/72 19.76 6.08 114 35.91
AS 320/72 19.76 6.08 114 36.48
AS 325/72 19.76 6.08 114 37.05
AS 85 HPC 36.83 11.54 396 33.66
AS 90 HPC 36.83 11.54 396 35.64
AS 95 HPC 36.83 11.54 396 37.62
AS 100 HPC 36.83 11.54 396 39.60
AS 105 HPC 36.83 11.54 396 41.58
AS 110 HPC 36.83 11.54 396 43.56
en batería uno encima del otro Σ eficacia
10 11 110 34.10

vertical
en batería uno encima del otro
[P]=kWp
15.38 9.13 135 12.15
15.38 9.13 135 12.83
15.38 9.13 135 13.50
15.38 9.13 135 14.18
15.38 9.13 135 14.85
13.51 17.78 221 22.10
13.51 17.78 221 24.31
13.51 17.78 221 25.42
13.51 17.78 221 26.52
13.51 17.78 221 27.63
13.51 17.78 221 28.73
13.51 17.78 221 29.84
13.51 17.78 221 30.94
13.51 17.78 221 33.15
13.51 17.78 221 35.36
12.35 14.48 168 31.92
12.35 14.48 168 32.76
12.35 14.48 168 33.60
12.35 14.48 168 34.44
12.35 14.48 168 35.28
12.07 11.86 132 26.40
12.07 11.86 132 27.06
12.07 11.86 132 27.72
12.07 11.88 132 28.38
12.07 11.86 132 29.04
12.07 11.86 132 29.70
12.07 11.86 132 30.36
12.07 11.86 132 31.02
12.07 11.86 132 31.68
12.07 11.86 132 32.34
12.07 11.86 132 33.00
12.07 11.86 132 33.66
12.07 11.86 132 34.32
12.07 11.86 132 35.64
10.14 11.86 110 29.70
10.14 11.86 110 30.25
10.14 11.86 110 30.80
10.14 11.86 110 31.35
10.14 11.86 110 31.90
10.14 11.86 110 32.45
10.14 11.86 110 33.00
10.14 11.86 110 33.55
10.14 11.86 110 34.10
10.14 11.86 110 34.65
10.14 11.86 110 35.20
10.14 11.86 110 35.75
13.51 17.78 221 26.52
13.51 17.78 221 27.63
13.51 17.78 221 28.73
13.51 17.78 221 29.84
13.51 17.78 221 30.94
13.51 17.78 221 33.15
12.35 14.48 168 29.40
12.35 14.48 168 30.24
12.35 14.48 168 31.08
12.35 14.48 168 31.92
12.35 14.48 168 32.76
12.35 14.48 168 33.60
12.35 14.48 168 34.44
12.35 14.48 168 35.28
12.07 11.86 132 25.08
12.07 11.86 132 26.40
12.07 11.86 132 27.06
12.07 11.86 132 27.72
12.07 11.86 132 28.38
12.07 11.86 132 29.04
12.07 11.86 132 29.70
12.07 11.86 132 30.36
12.07 11.86 132 31.02
12.07 11.86 132 31.68
12.07 11.86 132 32.34
12.07 11.86 132 33.00
12.07 11.86 132 34.32
12.07 11.86 132 38.28
10.14 11.86 110 29.70
10.14 11.86 110 30.80
10.14 11.86 110 31.35
10.14 11.86 110 31.90
10.14 11.86 110 32.45
10.14 11.86 110 33.00
10.14 11.86 110 33.55
10.14 11.86 110 34.10
10.14 11.86 110 34.65
10.14 11.86 110 35.20
10.14 11.86 110 35.75
19.23 22.10 418 35.53
19.23 22.10 418 37.62
19.23 22.10 418 39.71
19.23 22.10 418 41.80
19.23 22.10 418 43.89
19.23 22.10 418 45.98
x y

0 0
0 1
1.66666667 1
1.66666667 0
1.307 0.992
Cálculo de las dimensiones por módulo incluso sombreado:

Tipo de módulo PX 310/72 Entrada manual a= 0.341 m


Rendimiento del módulo 310 W 250 W b= 0.937 m
Longitud del módulo 1.973 m 1.62 m c= 0.091 m
Altitud del módulo 0.997 m 0.80 m
Inclinación del módulo (Q) 20 Longitud total
Ángulo del sol (γs) 60 ° PX 310/72 b+c = 1.028 m
Inclinación del techo (L) 15 °
L+S 75 °

Ángulo del sol (γs)


Superficie techo
a tasa de la superficie utilizada:
c
b Altitud/(b+c)= 96.96 %
L Q
γs
Nivel
Cálculo del número de módulos en la superficie disponible

Altitud del techo 15 m


Ancho del techo 8.9 m

número de módulos uno encima del otro posible 14 filas


Número de módulos en batería posible 4 módulos
Número total de módulos 56 módulos
Rendimiento de la instalación 17.36 kWp
Dimensionamiento de un sistema fotovoltaico autónomo, alimentación anual y diaria
1. Consumo energético diario
0
2 unidad lámpara 500 vatios 12 voltios horas de funcionamiento 3 horas = 250.00 Ah
1 unidad televisor 150 vatios 12 voltios horas de funcionamiento 4 horas = 50.00 Ah
1 unidad frigo 200 vatios 12 voltios horas de funcionamiento 12 horas = 200.00 Ah
0 unidad aparato 0 vatios 12 voltios horas de funcionamiento 0 horas = 0.00 Ah
0 unidad aparato 0 vatios 12 voltios horas de funcionamiento 0 horas = 0.00 Ah
0 unidad aparato 0 vatios 12 voltios horas de funcionamiento 0 horas = 0.00 Ah
0 unidad aparato 0 vatios 12 voltios horas de funcionamiento 0 horas = 0.00 Ah
0 unidad aparato 0 vatios 12 voltios horas de funcionamiento 0 horas = 0.00 Ah
0 unidad aparato 0 vatios 12 voltios horas de funcionamiento 0 horas = 0.00 Ah
0 unidad aparato 0 vatios 12 voltios horas de funcionamiento 0 horas = 0.00 Ah
0 unidad aparato 0 vatios 12 voltios horas de funcionamiento 0 horas = 0.00 Ah
0 unidad aparato 0 vatios 12 voltios horas de funcionamiento 0 horas = 0.00 Ah
0 unidad aparato 0 vatios 12 voltios horas de funcionamiento 0 horas = 0.00 Ah
0 unidad aparato 0 vatios 12 voltios horas de funcionamiento 0 horas = 0.00 Ah
0 unidad aparato 0 vatios 230 voltios horas de funcionamiento 0 horas = 0.00 Ah
0 unidad aparato 0 vatios 230 voltios horas de funcionamiento 0 horas = 0.00 Ah
0 unidad aparato 0 vatios 230 voltios horas de funcionamiento 0 horas = 0.00 Ah
0 unidad aparato 0 vatios 230 voltios horas de funcionamiento 0 horas = 0.00 Ah
0 unidad aparato 0 vatios 230 voltios horas de funcionamiento 0 horas = 0.00 Ah
0 unidad aparato 0 vatios 230 voltios horas de funcionamiento 0 horas = 0.00 Ah
0 unidad aparato 0 vatios 230 voltios horas de funcionamiento 0 horas = 0.00 Ah
0 unidad aparato 0 vatios 230 voltios horas de funcionamiento 0 horas = 0.00 Ah
Consumo energético total: 500.00 Ah
o 6.00 kWh

2. Dimensionamiento del generador solar:

Criterios de dimensionamiento utilización diaria, anual


Localidad Colombia
Factor local: 2.5 Horas de radiación solar / día

413.8 unidades del Generador solar SM 10 0.58 A Impp o


137.9 unidades del Generador solar SM 30 1.74 A Impp o
94.1 unidades del Generador solar SM 45 2.55 A Impp o
80.0 unidades del Generador solar AS 50 3 A Impp o
71.6 unidades del Generador solar AS 60 3.35 A Impp o
82.8 unidades del Generador solar PX 50 2.9 A Impp o
64.0 unidades del Generador solar PX 60 3.75 A Impp o
59.3 unidades del Generador solar PX 70 4.05 A Impp o
52.2 unidades del Generador solar PX 80 4.6 A Impp o
49.0 unidades del Generador solar PX 90 4.9 A Impp o
32.0 unidades del Generador solar PX 130 7.5 A Impp o
31.0 unidades del Generador solar PX 140 7.75 A Impp o
29.7 unidades del Generador solar PX 150 8.08 A Impp o

3. Dimensionamiento de las baterías:

Autonomía necesaria 2 día


Capacidad nominal necesaria 1666.66 Ah
Autonomía posible 2.0 días con 105 Ah baterías solares
Autonomía posible 2.1 días con 255 Ah baterías solares

16 unidades baterías solares por 105 Ah o


7 unidades baterías solares por 255 Ah son necesarias

Nota:
En el dimensionamiento del sistema, no están incluidos las pérdidas del cableado,
del regulador de carga y de las baterías!

En el caso de que haya carencia de energía en el sistema, especialmente durante los meses de inverno
a causa del tiempo, es posible conectar más generadores solares de todo momento.

El dimensionamiento del sistema está efectuado por:

SUNSET Energietechnik GmbH, Industriestraße 8 - 22, D - 91325 Adelsdorf


Tel: 09195/9494-0, Fax: 09195/9494-290
Tipo de célula Nombre Potencia Longitud Ancho Isc / A IMPP / A

(cerrado) Entrada manual 250 1.62 0.8 8.00 5.8


CIGS SA 90 90 1.3 1.3 1.15 0.91
CIGS SA 95 95 1.3 1.3 1.2 0.94
CIGS SA 100 100 1.3 1.3 1.24 1
CIGS SA 105 105 1.3 1.3 1.27 1.03
CIGS SA 110 110 1.3 1.3 1.3 1.06
poly PX 1006 100 1.48 0.66 6.8 6.1
poly PX 1106 110 1.48 0.66 7.5 6.6
poly PX 1156 115 1.48 0.66 7.6 7.1
poly PX 1206 120 1.48 0.66 7.8 7.25
poly PX 1256 125 1.48 0.66 8 7.38
poly PX 1306 130 1.48 0.66 8.1 7.5
poly PX 1356 135 1.48 0.66 8.2 7.65
poly PX 1406 140 1.48 0.66 8.4 7.75
poly PX 1506 150 1.48 0.66 8.7 8.08
poly PX 1606 160 1.48 0.66 9 8.41
poly PX 190/50 190 1.62 0.814 8.4 7.6
poly PX 195/50 195 1.62 0.814 8.5 7.7
poly PX 200/50 200 1.62 0.814 8.6 7.9
poly PX 205/50 205 1.62 0.814 8.7 8.1
poly PX 210/50 210 1.62 0.814 8.8 8.25
poly PX 200/60 200 1.657 0.997 7.6 6.9
poly PX 205/60 205 1.657 0.997 7.7 7
poly PX 210/60 210 1.657 0.997 7.8 7.11
poly PX 215/60 215 1.657 0.995 7.95 7.23
poly PX 220/60 220 1.657 0.997 8.1 7.4
poly PX 225/60 225 1.657 0.997 8.15 7.55
poly PX 230/60 230 1.657 0.997 8.2 7.7
poly PX 235/60 235 1.657 0.997 8.35 7.83
poly PX 240/60 240 1.657 0.997 8.5 7.95
poly PX 245/60 245 1.657 0.997 8.55 8
poly PX 250/60 250 1.657 0.997 8.8 8.17
poly PX 255/60 255 1.657 0.997 8.85 8.31
poly PX 260/60 260 1.657 0.997 9.05 8.45
poly PX 270/60 270 1.657 0.997 9.07 8.53
poly PX 270/72 270 1.973 0.997 8 7.55
poly PX 275/72 275 1.973 0.997 8.1 7.65
poly PX 280/72 280 1.973 0.997 8.2 7.75
poly PX 285/72 285 1.973 0.997 8.3 7.85
poly PX 290/72 290 1.973 0.997 8.4 7.95
poly PX 295/72 295 1.973 0.997 8.5 8.05
poly PX 300/72 300 1.973 0.997 8.6 8.15
poly PX 305/72 305 1.973 0.997 8.7 8.25
poly PX 310/72 310 1.973 0.997 8.8 8.35
poly PX 315/72 315 1.973 0.997 8.9 8.42
poly PX 320/72 320 1.973 0.997 9 8.51
poly PX 325/72 325 1.973 0.997 9.1 8.6
mono AS 1206 120 1.48 0.66 7.8 7.25
mono AS 1256 125 1.48 0.66 8 7.3
mono AS 1306 130 1.48 0.66 8.1 7.5
mono AS 1356 135 1.48 0.66 8.3 7.7
mono AS 1406 140 1.48 0.66 8.4 7.75
mono AS 1506 150 1.48 0.66 8.7 8.08
mono AS 175/50 175 1.62 0.814 7.98 7.2
mono AS 180/50 180 1.62 0.814 8.05 7.3
mono AS 185/50 185 1.62 0.814 8.23 7.45
mono AS 190/50 190 1.62 0.814 8.4 7.6
mono AS 195/50 195 1.62 0.814 8.5 7.7
mono AS 200/50 200 1.62 0.814 8.6 7.9
mono AS 205/50 205 1.62 0.814 8.7 8.1
mono AS 210/50 210 1.62 0.814 8.8 8.25
mono AS 190/60 190 1.657 0.997 7.4 6.7
mono AS 200/60 200 1.657 0.997 7.6 6.9
mono AS 205/60 205 1.657 0.997 7.7 7
mono AS 210/60 210 1.657 0.997 7.8 7.11
mono AS 215/60 215 1.657 0.997 7.95 7.26
mono AS 220/60 220 1.657 0.997 8.1 7.4
mono AS 225/60 225 1.657 0.997 8.15 7.55
mono AS 230/60 230 1.657 0.997 8.2 7.7
mono AS 235/60 235 1.657 0.997 8.35 7.83
mono AS 240/60 240 1.657 0.997 8.5 7.95
mono AS 245/60 245 1.657 0.997 8.55 8
mono AS 250/60 250 1.657 0.997 8.8 8.17
mono AS 260/60 260 1.657 0.997 8.9 8.45
mono AS 270/60 270 1.657 0.997 9.1 8.7
mono AS 280/60 280 1.657 0.997 9.3 8.84
mono AS 290/60 290 1.657 0.997 9.55 9.03
mono AS 270/72 270 1.973 0.997 8 7.55
mono AS 280/72 280 1.973 0.997 8.2 7.75
mono AS 285/72 285 1.973 0.997 8.3 7.85
mono AS 290772 290 1.973 0.997 8.4 7.95
mono AS 295/72 295 1.973 0.997 8.5 8.05
mono AS 300/72 300 1.973 0.997 8.6 8.15
mono AS 305/72 305 1.973 0.997 8.7 8.25
mono AS 310/72 310 1.973 0.997 8.8 8.35
mono AS 315/72 315 1.973 0.997 8.9 8.42
mono AS 320/72 320 1.973 0.997 9 8.51
mono AS 325/72 325 1.973 0.997 9.1 8.6
HPC AS 85 HPC 85 1.04 0.528 5.3 4.95
HPC AS 90 HPC 90 1.04 0.528 5.5 5.12
HPC AS 95 HPC 95 1.04 0.528 5.75 5.35
HPC AS 100 HPC 100 1.04 0.528 6 5.6
HPC AS 105 HPC 105 1.04 0.528 6.2 5.8
HPC AS 110 HPC 110 1.04 0.528 6.4 6
Umpp / V Uoc / V Umpp(75°C) Uoc (-10°C) Tk(Uoc) Tk(Umpp)
Umin Umax

20 24 16.40 26.30 -0.30% -0.40% 3


102 137 83.64 150.15 -0.30% -0.40% 3
103 137 84.46 150.15 -0.30% -0.40% 3
103 138 84.37 151.25 -0.30% -0.40% 3
103 138 84.37 151.25 -0.30% -0.40% 3
104 139 122.77 125.66 0.30% 0.40% 3
16.4 20.5 19.17 18.53 0.30% 0.38% 3
16.7 20.7 19.49 18.71 0.30% 0.37% 3
16.9 21 13.59 23.35 -0.35% -0.43% 3
16.5 21 13.19 23.35 -0.35% -0.45% 3
16.9 21.2 13.56 23.57 -0.35% -0.44% 4
17.2 21.4 13.83 23.80 -0.35% -0.44% 4
17.6 21.9 14.15 24.35 -0.35% -0.44% 4
18 21.8 14.57 24.24 -0.35% -0.42% 4
18.5 22.2 15.00 24.69 -0.35% -0.42% 4
19 22.6 15.44 25.13 -0.35% -0.42% 4
24.9 30.8 19.51 34.57 -0.35% -0.43% 2
25.2 31 19.78 34.80 -0.35% -0.43% 4
25.3 31.2 19.84 35.02 -0.35% -0.43% 4
25.35 31.4 19.86 35.25 -0.35% -0.43% 4
25.45 31.6 19.92 35.47 -0.35% -0.43% 4
29 36 22.70 40.41 -0.35% -0.43% 4
29.25 36.15 22.92 40.58 -0.35% -0.43% 4
29.5 36.3 23.15 40.75 -0.35% -0.43% 4
29.7 36.5 23.31 40.97 -0.35% -0.43% 4
29.8 36.6 23.40 41.08 -0.35% -0.43% 1
29.9 36.8 23.46 41.31 -0.35% -0.43% 4
29.9 36.9 23.44 41.42 -0.35% -0.43% 1
30.1 37.1 23.61 41.64 -0.35% -0.43% 2
30.3 37.2 23.79 41.76 -0.35% -0.43% 2
30.35 37.3 23.82 41.87 -0.35% -0.43% 2
30.5 37.4 23.96 41.98 -0.35% -0.43% 2
30.6 37.4 24.06 41.98 -0.35% -0.43% 2
30.7 37.9 24.07 42.54 -0.35% -0.43% 2
31.6 39 24.78 43.78 -0.35% -0.43% 2
35.8 45.4 27.86 50.96 -0.35% -0.44% 2
36 45.6 28.02 51.19 -0.35% -0.44% 2
36.1 45.7 28.10 51.30 -0.35% -0.44% 2
36.3 45.9 28.27 51.52 -0.35% -0.44% 2
36.4 46 28.35 51.64 -0.35% -0.44% 2
36.6 46.2 28.52 51.86 -0.35% -0.44% 2
36.7 46.3 28.60 51.97 -0.35% -0.44% 2
37 46.5 28.86 52.20 -0.35% -0.44% 2
37.2 46.6 29.05 52.31 -0.35% -0.44% 2
37.4 46.8 29.21 52.53 -0.35% -0.44% 2
37.6 47 29.38 52.76 -0.35% -0.44% 2
37.8 47.1 29.56 52.87 -0.35% -0.44% 2
16.9 21 13.33 23.50 -0.34% -0.42% 2
17.1 21.2 13.50 23.72 -0.34% -0.42% 2
17.2 21.4 13.56 23.95 -0.34% -0.42% 2
17.6 21.75 13.90 24.34 -0.34% -0.42% 2
18 21.8 14.29 24.39 -0.34% -0.41% 2
18.5 22.2 14.73 24.84 -0.34% -0.41% 2
24.3 30.3 19.15 33.91 -0.34% -0.42% 2
24.6 30.5 19.42 34.13 -0.34% -0.42% 1
24.7 30.6 19.50 34.24 -0.34% -0.42% 1
24.9 30.8 19.66 34.47 -0.34% -0.42% 1
25.2 31 19.93 34.69 -0.34% -0.42% 1
25.3 31.2 20.00 34.91 -0.34% -0.42% 1
25.35 31.4 20.01 35.14 -0.34% -0.42% 1
25.45 31.6 20.08 35.36 -0.34% -0.42% 1
28.5 35.6 22.45 39.84 -0.34% -0.42% 1
29 36 22.88 40.28 -0.34% -0.42% 1
29.3 36.15 23.15 40.45 -0.34% -0.42% 1
29.5 36.3 23.33 40.62 -0.34% -0.42% 1
29.7 36.5 23.50 40.84 -0.34% -0.42% 1
29.8 36.6 23.58 40.96 -0.34% -0.42% 1
29.9 36.8 23.64 41.18 -0.34% -0.42% 1
29.9 36.9 23.63 41.29 -0.34% -0.42% 1
30.1 37.1 23.79 41.51 -0.34% -0.42% 1
30.3 37.2 23.98 41.63 -0.34% -0.42% 1
30.4 37.3 24.06 41.74 -0.34% -0.42% 1
30.5 37.4 24.14 41.85 -0.34% -0.42% 1
30.7 37.4 24.34 41.85 -0.34% -0.41% 1
31 37.9 24.56 42.41 -0.34% -0.42% 1
31.6 38.4 25.07 42.97 -0.34% -0.41% 1
32.2 38.9 25.59 43.53 -0.34% -0.41% 1
35.8 45.4 28.08 50.80 -0.34% -0.43% 1
36.1 45.7 28.33 51.14 -0.34% -0.43% 1
36.3 45.9 28.50 51.36 -0.34% -0.43% 1
36.4 46 28.58 51.47 -0.34% -0.43% 1
36.6 46.2 28.75 51.70 -0.34% -0.43% 1
36.7 46.3 28.83 51.81 -0.34% -0.43% 1
37 46.5 29.10 52.03 -0.34% -0.43% 1
37.2 46.6 29.28 52.15 -0.34% -0.43% 1
37.4 46.8 29.44 52.37 -0.34% -0.43% 1
37.6 46.9 29.63 52.48 -0.34% -0.42% 1
37.8 47.1 29.79 52.70 -0.34% -0.42% 1
17.2 21.2 14.13 23.35 -0.29% -0.36% 1
17.6 21.4 14.50 23.57 -0.29% -0.35% 1
17.7 21.5 14.58 23.68 -0.29% -0.35% 1
17.8 21.6 14.67 23.79 -0.29% -0.35% 1
18.1 21.7 14.95 23.90 -0.29% -0.35% 1
18.3 21.9 15.12 24.12 -0.29% -0.35% 1
Entrada manual SMA
Entrada manual SB 3000 TL SB 3600 TL
Entrada
Datos demanual
entrada
SB 3000
Potencia
TL fotovoltaica máx recomandada 3200 3880
SB 3600
ristras
TL cortas/largas lungas lungas
SB 4000
Potencia
TL DC máx 3200 3880
SB 5000
(Pdc,max)
TL /W
Tripower Tensión
5000 TLDC máx 750 750
Tripower (Udc,max)
6000 TL / V
Tripower Tensión
7000 TLDC min 125 125
Tripower (Udc,min)
8000 TL / V
Tripower Rango
9000 TL
de tensión 175-500V 175-500V
Tripower 10000TL
MPPT (Upv)
Tripower 12000TL
Corriente de entrada máx 15 15
Tripower 15000TL
( Ipv,max) / A
Tripower 17000TL
Número de ristras (paralelas) 4 4
Tripower 20000
Valores
TLde salida
Tripower 25000
Potencia
TL AC máx 3000 3680
SUN3Grid3000
(Pac,max)
SUN3Grid
Potencia
4000 AC nominal 3000 3680
SUN3Grid
(Pac,nom)
5000
SUN3Grid
Rendimiento
6000
SUN3Grid8000
Euro-η 96.00% 96.40%
Sunstring
Rendimiento
3000 máx 97.00% 97.00%
Sunstring
Clase
4000de protección
Sunstring
según
5000DIN EN 60529 IP65 IP65
Powador
Características
3200 mecánicas
Powador
Ancho
4400 490 490
Powador
Longitud
5300 519 519
Powador
Ancho
5500 185 185
Powador
Peso
6600 26kg 26kg
Powador 2002
Powador 3002
Powador 4202
Powador 5002
Powador 6002
blueplanet 3.0 TL1
blueplanet 3.5 TL1
blueplanet 3.7 TL1
blueplanet 4.0 TL1
blueplanet 4.6 TL1
blueplanet 5.0 TL1
blueplanet 5.0 TL3
blueplanet 6.5 TL3
blueplanet 7.5 TL3
blueplanet 9.0 TL3
Powador 12.0 TL3
Powador 14.0 TL3
Powador 18.0 TL3
Powador 20.0 TL3
Powador 30.0 TL3
Powador 33.0 TL3
Powador 36.0 TL3
Powador 39.0 TL3
Powador 40.0 TL3
Powador 60.0 TL3
blueplanet 50.0 TL3
Powador 48.0 TL3 Park
Powador 72.0 TL3 Park
StecaGrid 2020
SB 4000 TL SB 5000 TL Tripower 5000 TL Tripower 6000 TL Tripower 7000 TL

4200 5250 5100 6125 7175


lungas lungas cortas cortas cortas
4200 5250 5100 6125 7175

750 750 1000 1000 1000

125 125 150 150 150

175-500V 175-500V 245-800V 295-800V 290-800V

15 15 11 11 15

4 4 4 4 4

4000 5000 5000 6000 7000

4000 4600 5000 6000 7000

96.40% 96.50% 97.10% 97.40% 97.50%


97.00% 97.00% 98.00% 98.00% 98.00%

IP65 IP65 IP 65 IP 65 IP 65

490 490 470 470 470


519 519 730 730 730
185 185 240 240 240
26kg 26kg 37kg 37kg 37kg
Tripower 8000 TL Tripower 9000 TL Tripower 10000TL Tripower 12000TL

8200 9225 10250 12275


cortas cortas cortas cortas
8200 9225 10250 12275

1000 1000 1000 1000

150 150 150 150

330-800V 370-800V 370-800 440-800

15 15 18 18

4 4 4 4

8000 9000 10000 12000

8000 9000 10000 12000

97.60% 97.60% 97.60% 97.90%


98.00% 98.00% 98.00% 98.30%

IP 65 IP 65 IP 65 IP 65

470 470 470 470


730 730 730 730
240 240 240 240
37kg 37kg 37kg 38kg
Tripower 15000TL Tripower 17000TL Tripower 20000 TL Tripower 25000 TL

15340 17410 20440 25550


cortas cortas cortas cortas
15340 17410 20440 25550

1000 1000 1000 1000

150 150 150 150

360-800 400-800 320-800V 390-800V

40 40 33 33

6 6 6 6

15000 17000 20000 25000

15000 17000 20000 25000

97.80% 97.80% 98.00% 98.10%


98.20% 98.20% 98.40% 98.30%

IP 65 IP 65 IP65 IP65

665 665 661 661


690 690 682 682
265 265 264 264
59kg 59kg 61 61
SUN3Grid
SUN3Grid3000 SUN3Grid 4000 SUN3Grid 5000 SUN3Grid 6000 SUN3Grid8000

cortas cortas cortas cortas cortas


3030 4000 5310 6300 8300

800 800 800 800 800

350 350 350 350 350

350-800V 350-800 V 350-800 V 350-800 V 350-800V

9 12 14 18 21.4

3 3 3 3 3

2850 4000 4600 6000 8000

2850 4000 4600 6000 8000

95.80% 95.50% 95.70% 95.70% 96.20%


96.60% 96.50% 96.30% 96.30% 96.60%

IP 21 IP 21 IP 21 IP 21 IP 21

352 352 352 352 352


555 555 555 555 810
235 235 235 235 235
ca.19kg ca. 21 kg ca. 24 kg ca. 28 kg ca. 38 kg
SUNstring Kaco
Sunstring 3000 Sunstring 4000 Sunstring 5000 Powador 3200 Powador 4400

cortas cprtas cortas


3200 4300 5060 2860 3960

600 600 600 800 800

200 200 200 350 350

125…400 V 125...400 V 125...400 V 350-600 350-600

16 21 26.5 8.6 12

3 3 3 3 3

3000 4000 4600 2600 3600

3000 4000 4600 2600 3600

94.50% 93.30% 93.30% 95.80% 95.90%


95.90% 95.90% 95.90% 96.60% 96.50%

IP21 IP 21 IP 21

352 352 352 340 340


555 555 555 500 550
235 235 235 200 220
25 kg 26 kg 26 kg 19 21
Powador 5300 Powador 5500 Powador 6600 Powador 2002 Powador 3002

4840 5060 6050 1815 2750

800 800 800 600 600

350 350 350 125 200

350-600 350-600 350-600 125-510 200-510

14.5 15.2 18 14.3 13.5

3 3 3 3 3

4400 4600 5500 1650 2500

4400 4600 5500 1650 2500

95.80% 95.70% 95.80% 95.30% 95.40%


96.40% 96.30% 96.30% 95.90% 96.00%

IP54 IP54

340 340 340 340 340


550 600 600 450 500
220 220 220 200 200
26 28 30 14.5 20
Powador 4202 Powador 5002 Powador 6002 blueplanet 3.0 TL1 blueplanet 3.5 TL1

3850 4620 5500 3000 3500

600 600 600 600 600

200 200 200 125 125

200-510 200-510 200-510 140-510 165-510

18.5 22.4 26.5 11 11

3 3 3 4 4

3500 4200 5000 3000 3450

3500 4200 4600 3000 3450

95.10% 95.30% 95.30% 96.50% 96.40%


95.90% 95.90% 95.90% 97.20% 97.20%

IP54 IP54 IP54 IP54 IP54

340 340 340 367 367


600 600 600 560 560
240 240 240 227 227
26 28 28 16,5kg 18kg
blueplanet 3.7 TL1 blueplanet 4.0 TL1 blueplanet 4.6 TL1 blueplanet 5.0 TL1 blueplanet 5.0 TL3

3700 4000 4600 5000 5000

600 600 600 600 1000

125 125 125 125 200

170-510 185-510 215-510 235-510 240-800

11 11 11 11 11

4 4 4 4 4

3680 4000 4600 5000 5000

3680 4000 4600 5000 5000

96.50% 96.60% 96.70% 96.60% 97.40%


97.20% 97.20% 97.20% 97.20% 98.30%

IP54 IP54 IP54 IP54 IP65

367 367 367 367 363


560 560 560 560 522
227 227 227 227 246
18kg 18kg 18kg 18kg 30kg
blueplanet 6.5 TL3 blueplanet 7.5 TL3 blueplanet 9.0 TL3 Powador 12.0 TL3 Powador 14.0 TL3

7150 8250 9900 11000 13750

1000 1000 1000 1000 1000

200 200 200 200 200

310-800 350-800 420-800 280-800 350-800

11 11 11 18.6 18.6

4 4 4 4 4

6500 7500 9000 10000 12500

6500 7500 9000 10000 12500

97.60% 97.70% 97.90% 97.50% 97.60%


98.30% 98.30% 98.30% 98.00% 98.00%

IP65 IP65 IP65 IP65 IP65

363 363 363 420 420


522 522 522 690 690
246 46 246 200 200
30kg 30kg 30kg 40kg 40kg
Powador 18.0 TL3 Powador 20.0 TL3 Powador 30.0 TL3 Powador 33.0 TL3 Powador 36.0 TL3

1650 18700 27500 30250 33000

1000 1000 1000 1000 1000

200 200 200 200 200

420-800 470-800 260-800 280-800 310-800

18.6 18.6 34 34 34

4 4 12 12 12

15000 17000 25000 27500 30000

15000 17000 25000 27500 30000

97.70% 97.60% 97.80% 97.80% 97.80%


98.00% 97.90% 98.00% 98.00% 98.00%

IP65 IP65 IP54 IP54 IP54

420 420 840 840 840


690 690 1360 1360 1360
200 200 355 355 355
44kg 44kg 151kg 151kg 151kg
Powador 39.0 TL3 Powador 40.0 TL3 Powador 60.0 TL3 blueplanet 50.0 TL3 Powador 48.0 TL3 Park

36630 39600 54890 50000 44000

1000 1000 1000 1100 1000

200 200 200 570 200

340-800 370-800 480-850 570-900 410-800

34 34 36 90 34

12 12 12 10 12

33300 36000 49900 50000 40000

33300 36000 49900 50000 40000

97.80% 97.20% 97.60% 98.00% 97.90%


98.00% 97.50% 97.80% 98.30% 98.00%

IP54 IP54 IP54 IP65 IP54

840 840 840 500 840


1360 1360 1360 760 1360
355 355 355 425 355
151kg 151kg 151kg 73kg 151kg
Steca
Powador 72.0 TL3 Park StecaGrid 2020

66000 2090

1000 450

200 210

580-850 210-400

36 10

15

60000 2000

60000 2000

98.00% 96.70%
98.30% 97.50%

IP54 IP 21

840 340
1360 608
355 222
173 kg 9kg

También podría gustarte