PREGUNTA No 2.

CALCULAR LOS ESFUERZOS VERTICALES TOTALES DEBAJO DE LOS PUNTOS A Y B, EN EL MEDIO DEL ESTRATO DE ARCILLA
CL. Del edificio, que se muestra en la figura. El nivel de saturacion por capilaridad llega hasta -2.0

0 -------------------------------------------------------------------------------------------------------------------------------------------------
OH gm= 1.66

-2.6 -------------------------------------------------------------------------------------------------------------------------------------------------
OL gm= 1.88
N.F. gsat= 1.99
-4.3 -------------------------------------------------------------------------------------------------------------------------------------------------
gsat= 2.08

-12.1 -------------------------------------------------------------------------------------------------------------------------------------------------
gsat= 2.18
-17.5
-18.5
-19.5
DIBUJO EN PLANTA
A
15 PISOS gagua=
12.75 12 PISOS 1.85 TON/M2/PISO
1.67 TON/M2/PIS B
10.75

7.5 9.2
SOLUCION
A. ESFUERZOS EFECTIVOS. PARA EL PUNTO A
stotal= 29.809 μ= 10.5 sefectivo= 19.309
PARA EL PUNTO B
stotal= 30.899 μ= 11 sefectivo= 19.899
B. ESFUERZOS SIGMA ZETA PARA EL PUNTO A
W1= 12.341 EDIFICIO UNO Wo(EDIF. 1)= 0.289
W2= 20.051 EDIFICIO DOS Wo(EDIF. 2)= -0.029
z B1 L1 m n A B C
10.5 7.5 10.75 1.45 0.81 0.07957747 4.53848789 5.12797868
10.5 7.5 12.75 0.88 0.49 0.07957747 1.22911636 2.20591761
10.5 16.7 10.75 0.63 0.35 0.07957747 0.55131382 1.5754942
10.5 7.5 10.75 0.71 1.02 0.07957747 2.33940009 3.09317877
10.5 16.7 12.75 1.59 1.21 0.07957747 8.64054687 8.73399509
10.5 7.5 12.75 0.71 1.21 0.07957747 2.99690339 3.73698459

σz(EDIF 1)= 3.566


σz(EDIF 2)= -0.579 σn(A)= 22.297 Ton/m2

B. ESFUERZOS SIGMA ZETA PARA EL PUNTO B


W1= 12.341 EDIFICIO UNO Wo(EDIF. 1)= 0.299
W2= 20.051 EDIFICIO DOS Wo(EDIF. 2)= 0.186
z B1 L1 m n A B C
11 7.5 12.75 0.68 1.16 0.07957747 2.64876277 3.43292488
11 7.5 10.75 0.68 0.98 0.07957747 2.07308197 2.86392344
11 9.2 23.5 0.84 2.14 0.07957747 8.94356604 9.45612526
11 9.75 13.5 0.89 1.23 0.07957747 3.94731961 4.47516926

σz(EDIF 1)= 3.69256591


σz(EDIF 2)= 3.72866934 σn(B)= 27.32 Ton/m2
O DEL ESTRATO DE ARCILLA

---------------------------------------------------------
tn/m3

----------------------------------------------------------
tn/m3
tn/m3
----------------------------------------------------------
tn/m3

--------------------------------------------------------
tn/m3

1 tn/m3

D E F FACT INFLUENC
1.26613127 1.90124809 1.08658899 0.176
1.49533422 0.67100287 0.59099859 0.113
1.65544143 0.37354808 0.35749715 0.075
1.39087082 1.15605782 0.85765325 0.152
1.19983596 6.78108239 1.42438252 0.208
1.33504274 1.34245616 0.93056511 0.159
D E F FACT INFLUENC
1.35607872 1.21290862 0.88131505 0.153
1.41323372 1.04915572 0.80938184 0.146
1.15965378 2.91228198 1.24003714 0.186
1.30378158 1.87209098 1.08019401 0.177
z B1 L1 m n A B C
5.5 7 10 1.27 1.82 0.07957747 11.2659949 11.2804453
5.5 7 6 1.27 1.09 0.07957747 5.42015473 5.73765453
5.5 23 10 4.18 1.82 0.07957747 70.9896169 79.6036473
5.5 7 6 1.27 1.09 0.07957747 5.42015473 5.73765453
5.5 23 10 4.18 1.82 0.07957747 70.9896169 79.6036473
5.5 7 10 1.27 1.82 0.07957747 11.2659949 11.2804453

0.021 0.043 0.023 0.087 19.5

σz= 1.69
N° DE AREAS 42
V.I. 0.005 σz= 4.095
CARGA 19.5
D E F FACT INFLUENC
1.16875872 19.7373975 1.52017437 0.214
1.26247289 2.8797215 1.23656832 0.193
1.04588548 -1.9710101 2.04030986 0.237
1.26247289 2.8797215 1.23656832 0.193
1.04588548 -1.9710101 2.04030986 0.237
1.16875872 19.7373975 1.52017437 0.214

kN/m2

kN/m2
z B1 L1 m n A B
1 17.5 9 12 0.51 0.69 0.07957747 0.92894302
2 17.5 9 5 0.51 0.29 0.07957747 0.34096413
3 17.5 36 12 2.06 0.69 0.07957747 6.73678684
4 17.5 8 5 0.46 0.29 0.07957747 0.29676439
5 17.5 36 13 2.06 0.74 0.07957747 7.35024194
6 17.5 8 13 0.46 0.74 0.07957747 0.9012479

0.050 0.117 0.075 0.241

σz=
N° DE AREAS 47
V.I. 0.005 σz=
CARGA 43.75
C D E F FACT INFLUENC
1.85905806 1.57647059 0.57686511 0.52323483 0.104
1.36771345 1.74287447 0.25742245 0.25195221 0.055
7.69186772 1.17537581 1.81476257 1.06715786 0.167
1.3076718 1.77482606 0.23302089 0.22893561 0.050
8.11895643 1.17290049 2.1314993 1.13212914 0.175
1.87613894 1.56791841 0.54770668 0.5010808 0.100

43.75 kN/m2

10.55 kN/m2

10.28125
PREGUNTA No. 1 DETERMINAR Y GRAFICAR LOS DIAGRAMAS DE ESFUERZOS TOTALES, NEUTRALES Y EFECTIVOS DEL PERFIL

0 --------------------------------------------------------------------------------------------------------------------------------------
ARENA MAL GRADUADA MEDIANAMENTE DENSA W%= 8.75
e= 0.51
Gs= 2.65
N= 0.1158 cm2
N.F. D10= 0.00065 cm
-5.2 --------------------------------------------------------------------------------------------------------------------------------------

-8.5 -------------------------------------------------------------------------------------------------------------------------------------
LIMO INORGANICO n= 0.58 e= 1.38095238
Gs= 2.72
-16.5 -------------------------------------------------------------------------------------------------------------------------------------
ARCILLA INORGANICA e= 0.63
Gs= 2.83
-18.4 -------------------------------------------------------------------------------------------------------------------------------------
ARENA MAL GRADUADA Gw= 100 Ws= 2.77966102
w%= 25 e= 0.69491525
gd= 1.64 gr/cm3
-20 --------------------------------------------------------------------------------------------------------------------------------------

hc= 3.493 m gagua= 1

Z ESF TOTALES PRES. DE PORESF. EFECTIVOS


0 0 0 0.0
CAPILARIDAD -1.71 3.26 -3.49 3.26 6.75
NIVEL FREATI -5.2 10.57 0 10.6
-8.5 17.47 3.3 14.2
-16.5 31.25 11.3 20.0
-18.4 35.29 13.2 22.1
-20 38.57 14.8 23.77
RALES Y EFECTIVOS DEL PERFIL DEL SUELO QUE SE INDICA

-----------------------------

gm= 1.909 tn/m3 9.81 18.7226449


9.81 0
9.81 0
----------------------------- 9.81 0
9.81 0
gsat= 2.093 tn/m3 9.81 20.5295364
---------------------------- 9.81 0
9.81 0
gsat= 1.722 tn/m3 9.81 16.896744
---------------------------- 9.81 0
9.81 0
gsat= 2.123 tn/m3 9.81 20.823681
---------------------------- 9.81 0
9.81 0
9.81 0
gsat= 2.050 tn/m3 9.81 20.1105
-----------------------------