A pressure drawdown test is run in a well located between two intersecting sealing faults.

Given the following data,


calculate K, S, C, angle of intersection and distance to the faults.

t (horas) P (psia) t*∆P' q 700 rw


0.00010 3845.93 2.22 B 1.2 ct
0.00030 3841.5 10.22 h 68 Viscosidad
0.00040 3836.96 17.39 porosidad 0.1 Pi
0.00050 3832.8 16.92
0.00100 3820.93 26.64
0.00140 3812.96 30.39
0.00220 3798.51 33.4
0.00300 3787.65 37.35
0.00410 3776.49 37.66
0.00550 3765.82 32.86
0.00750 3756.4 27.13
0.01020 3748.65 23
0.01390 3742.5 17.95
0.01900 3737.46 15.17
0.02580 3732.99 14.03
0.03510 3728.74 13.6
0.04780 3724.58 13.41
0.06510 3720.47 13.25
0.08860 3716.4 13.16
0.12060 3712.38 12.96
0.16430 3708.38 12.99
0.22360 3704.36 13.21
0.30440 3700.19 13.9
0.41440 3695.74 15.04
0.56420 3690.89 16.42
0.76810 3685.6 17.88
1.04560 3679.85 19.31
1.42350 3673.69 20.58
1.93790 3667.17 21.65
2.63830 3660.35 22.53
0.35917 3653.28 23.21
4.88970 3646.02 23.83
6.65670 3638.6 24.32
9.06230 3631.05 24.61
12.33720 3623.42 24.78
3900
16.79560 3615.75 25.06
22.86530 3607.94 25.8
31.12830 3599.75 27.44
42.37740 3590.95 29.77 3800
57.69180 3581.32 32.68
78.54050 3570.77 35.67
106.92350 3559.3 38.56
145.56350 3546.99 41.13 3700

3600
3700
198.16720 3533.95 43.3
269.78090 3520.32 45.02
367.27440 3506.19 46.43
3600

3500

3400

3300
0.00010 0.00100 0.01000
ven the following data,

0.333
1.40E-06
0.8
3850

C
100

10

1
0.00010 0.00100 0.01000 0.10000

semilog
0.00100 0.01000 0.10000 1.00000 10.00000 100.00000 1000.00000
Chart Title

0.01000 0.10000 1.00000 10.00000 100.00000 1000.00000