Documentos de Académico
Documentos de Profesional
Documentos de Cultura
8 B) D1 in D2 in D3 in D4 in
grosor del aislnte que reduzca la perdida 2% 3.068 3.5 4.5 5.5
3.068 3.5 5.5 7.5
3.068 3.5 6.5 9.5
3.068 3.5 7.5 11.5
3.068 3.5 8.5 13.5
3.068 3.5 9.5 15.5
3.068 3.5 10.5 17.5
3.068 3.5 11.5 19.5
3.068 3.5 12.5 21.5
3.068 3.5 13.5 23.5
3.068 3.5 14.5 25.5
3.068 3.5 15.5 27.5
3.068 3.5 16.5 29.5
3.068 3.5 17.5 31.5
3.068 3.5 18.5 33.5
3.068 3.5 19.5 35.5
3.068 3.5 20.5 37.5
3.068 3.5 21.5 39.5
3.068 3.5 22.5 41.5
3.068 3.5 23.5 43.5
q vs R de aislante
140
120
100
Flujo de calor BTU/h f
80
60
40
20
0
0.00 2.00 4.00 6.00
Radio in
0
0.00 2.00 4.00 6.00
Radio in
K, acero BTU/h ft^2 (F/ft) K, kapok BTU/h ft^2 (F/ft) K, asbesto BTU/h ft^2 (F/ft) ha vapor BTU h ft^2 F
26 0.02 0.087 1.9
26 0.02 0.087 1.9
26 0.02 0.087 1.8
26 0.02 0.087 1.7
26 0.02 0.087 1.7
26 0.02 0.087 1.7
26 0.02 0.087 1.7
26 0.02 0.087 1.7
26 0.02 0.087 1.7
26 0.02 0.087 1.7
26 0.02 0.087 1.7
26 0.02 0.087 1.7
26 0.02 0.087 1.7
26 0.02 0.087 1.7
26 0.02 0.087 1.7
26 0.02 0.087 1.7
26 0.02 0.087 1.7
26 0.02 0.087 1.7
26 0.02 0.087 1.7
26 0.02 0.087 1.7
q vs R de aislante
Radio in
6.00 8.00 10.00 12.00
Radio in
T1 F Ta F T4 F R tubo in q BTU/h ft
421.56 70 117 0.50 128.7449236
421.56 70 117.059311 1.00 79.38839291
421.56 70 91.2801109 1.50 60.21657976
421.56 70 83.4509115 2.00 49.9703184
421.56 70 79.7633104 2.50 43.587505
421.56 70 77.2545597 3.00 39.16033647
421.56 70 75.6767208 3.50 35.89064611
421.56 70 74.6081441 4.00 33.36507701
421.56 70 73.8445042 4.50 31.34762628
421.56 70 73.2760387 5.00 29.69346412
421.56 70 72.8390682 5.50 28.30862178
421.56 70 72.4943728 6.00 27.12936761
421.56 70 72.2166126 6.50 26.11088737
421.56 70 71.9887603 7.00 25.22070858
saidel:
421.56 70 71.7989933 7.50 24.43469741 radio optimo reduciendo
421.56 70 71.6388718 8.00 23.73452411 la perdida al 2%
421.56 70 71.502225 8.50 23.10600327 24.43<24.52