hi 1330.34639 W/m2K
G' 0.00392827
Ref 104.75396
h 1378.27208 W/m2K
Condensador vertical
G'' 0.11085747
Ref 2956.19918
h 448.616418 W/m2K laminar
ordenada de Dukler 0.28
h Dukler 1194.14751
h pelcula 1378.27208
Nussel Pelic 290.968549
G medio 42.9462372
Re 268624.3
R 925.889392
H 0.015
X 0.92088875
Nusselt total 492.977484
h 2335.1565
This spreadsheet allows the calculation of a horizontal condenser refrigerated by water with shell side condensation. Data must be entered in the yellow cells
Ft factor in cell B12 must be calculated with the four extremes temperatures. (The water outlet tempereature can be obtained from cell D32 once the data corresponding to the
condensation curve have been entered in range A26.L31). Data corresponds to example 10-4
Estimated values of the wall temperatures must be entered in row 42 and the calculated values in row 55 can be fed back up to convergence
(Please note that the iteration is not closed with the initial values of the worksheet, so the results still may slightly change)
Clculations of the heat transfer coefficients and pressure drop are based on Kern's correlations
Calculations for the cooling water velocity 1.78 m/s mean temp 39.76 C hio 6306.44008
viscosity 1.00 cp Re 25708.332
Interval 1 2 3 4 5
gamma 0 0 0 0 0
ho 8089 7153 5771 4085 1413
friction factor for the interval 0.1962 0.2071 0.2235 0.2546 Err:502
delta p for the calculated area (N/m2) 9586 5230 2452 741