Está en la página 1de 52

CARLOS ANDRES MENDOZA RINCON

Ingeniero Civil







MEMORIA INSTALACIONES HIDROSANITARIAS












CARLOS ANDRES MENDOZA RINCON
MAT. 25202-159269 CND









SABANALARGA, CASANARE

ESTUDIOS Y DISEOS PARA LA CONSTRUCCIN CENTRO
DEPORTIVO Y RECREATIVO DEL MUNICIPIO DE SABANA LARGA
DEPARTAMENTO DEL CASANARE

FECHA:
ENERO-2014
DOCUMENTO
MM-H-04
CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil





TABLA DE CONTENIDO

1. DESCIRPCION DE LAS REDES ..................................................................... 4
1.1. Red hidrulica ............................................................................................ 4
1.2. Aguas Negras ............................................................................................ 4
1.3. Aguas lluvias .............................................................................................. 4
2. PARAMETROS DE DISEO ........................................................................... 5
2.1 NORMAS Y ESPECIFICACIONES ............................................................... 5
2.2 FACTOR DE SIMULTANEIDAD ................................................................ 5
2.3 RED HIDRAULICA ..................................................................................... 5
2.3.1 Perdidas .............................................................................................. 5
2.3.2 Vlvulas ............................................................................................... 5
2.3.3 Evaluacin de caudales ....................................................................... 5
2.3.4 Presiones de diseo ............................................................................ 6
2.3.5 Velocidades ......................................................................................... 6
Velocidad Mnima ............................................................................................. 7
Velocidad Mxima ............................................................................................ 7
2.4 DESAGUES ............................................................................................... 7
2.4.1 Dimetros mnimos .............................................................................. 7
2.4.2 Separacin mnima .............................................................................. 7
2.4.3 Cambios en direccin del Flujo ............................................................ 7
2.4.4 Pendiente de la tubera sanitaria horizontal ......................................... 8
2.4.5 Disposicin en relacin con redes de suministro de agua de agua
potable 8
2.4.6 UBICACIN DE COLECTORES ......................................................... 9
2.4.7 Esfuerzo cortante ................................................................................. 9
2.4.8 Bajantes, colectores y conexiones para aguas lluvias ......................... 9
2.4.9 Limpieza ............................................................................................ 10
2.4.10 Dimensionamiento de Bajantes aguas lluvias ................................ 10
3. CALCULO REDES HIDRAULICAS ................................................................ 11
CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil


3.1 VOLUMEN DE RESERVA ....................................................................... 11
3.2 ACOMETIDA ............................................................................................ 11
3.3 RUTA CRITICA ........................................................................................ 12
3.4 Tabla calculo red hidrulica batera sanitaria ........................................... 14
3.5 Tabla calculo red hidrulica externa ......................................................... 14
3.6 EVALUACIN POTENCIA EQUIPO ........................................................ 16
3.7 EVALUACION EQUIPO DE PRESION CONSTANTE ............................. 19
4. EVALUACION DESAGUES DE AGUAS NEGRAS ........................................ 21
4.1 EVALUACIN DE CAUDALES Y CONDICIONES HIDRULICAS RED DE
DESAGES ....................................................................................................... 24
5. EVALUACION DESAGUES AGUAS LLUVIAS .............................................. 25
5.1 Desage aguas lluvias cubierta graderas ............................................... 25
5.2 Desage aguas lluvias cubierta cancha mltiple y cubierta batera
sanitaria ............................................................................................................. 29
5.3 Desage aguas lluvias cancha de futbol principal .................................... 34
5.4 Desage aguas lluvias cancha sinttica ................................................... 46
6. conclusiones y RECOMENDACIONES .......................................................... 52























CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil






1. DESCIRPCION DE LAS REDES

A continuacin se presentan las memorias tcnicas de las instalaciones Hidrosanitarias
del Centro deportivo y recreativo del municipio de Sabanalarga lo cual comprende la Red
Hidrulica, las redes desages de aguas negras y lluvias.


1.1. Red hidrulica

El abastecimiento de agua funcionara presurizando la red con un equipo hidroneumtico,
para garantizar la presin recomendada en todos los aparatos sanitarios y los puntos para
realizar el riego de zonas verdes, contara un volumen de reserva para 24 horas de
consumo de acuerdo a los requerimientos de agua de la batera sanitaria y el riego de la
cancha de Futbol.

1.2. Aguas Negras

La evacuacin de aguas negras se realizara mediante la construccin de una manija
compuesta de cajas de inspeccin, conectadas en tubera PVC sanitaria, las cuales se
unirn en un punto para su disposicin final en las cajas de inspeccin de las redes
externas proyectadas para dar servicio de alcantarillado al centro deportivo y recreativo.


1.3. Aguas lluvias

De acuerdo con los componentes del centro deportivo se proyectan los elementos
necesarios para la recoleccin y evacuacin de las aguas lluvias interceptadas en las
cubiertas de las graderas y cancha mltiple, zonas duras, y zonas verdes.

Los caudales de aguas lluvias interceptadas en las cubiertas de las graderas de la
cancha de futbol as como de la cancha mltiple, se recolectaran mediante canales reas
en lamina de acero las cuales entregaran mediante bajantes en tubera a una manija de
recoleccin compuestas de cajas de inspeccin y colectores en tubera PVC, para
entregar respectivamente a los pozos de inspeccin proyectados en las vas aledaas al
proyecto.

Los caudales interceptados en las canchas de futbol de recolectaran mediante una serie
de filtros que a su vez entregaran a cajas de inspeccin para posteriormente entregar a un
CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil


colector de aguas lluvias el cual entregara a la red de alcantarillado pluvial proyectada
sobre las vas externas del proyecto.

2. PARAMETROS DE DISEO
2.1 NORMAS Y ESPECIFICACIONES

El diseo se desarrolla basado en el Cdigo Colombiano de Fontanera NTC-1500, y el
reglamento tcnico de agua potable y saneamiento bsico RAS 2000.
2.2 FACTOR DE SIMULTANEIDAD

Este factor es aplicado para la evaluacin del caudal mximo probable, establecido del
mtodo de probabilidades de Roy B. Hunter de las unidades mximas probables de
acuerdo al nmero de aparatos sanitarios.


2.3 RED HIDRAULICA

2.3.1 Perdidas

Se aplicaran las ecuaciones de clculo de las prdidas dependiendo el dimetro que se
maneje segn el material de la tubera.

Se utilizaran las ecuaciones de Flaman para dimetros menores a 2, y la ecuacin de
Hazen Williams para dimetros mayores a 2

2.3.2 Vlvulas

Las vlvulas de corte estarn ubicadas para sectorizar algunos tramos de la red para
garantizar un adecuado mantenimiento.

Se deber de proveer de una vlvula de corte en cada bao o conjunto sanitario para
facilitar su mantenimiento futuro

2.3.3 Evaluacin de caudales

La evaluacin de caudales se realiza de acuerdo al volumen de produccin de agua
potable regulada por el reglamento tcnico del sector de agua potable y saneamiento
bsico RAS 2000, y el volumen de consumo regulado por el cdigo colombiano de
fontanera NTC 1500.

CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil




2.3.4 Presiones de diseo

La presin de diseo debe satisfacer la presin recomendada para el aparato ms alejado
del equipo de presin, a continuacin se presentan las presiones recomendadas para
aparatos sanitarios tipo fluxometro.































La presin mxima no debe superar la presin de trabajo mxima de las redes de
distribucin, establecidas en las normas tcnicas correspondientes a cada material.

La Mxima Presin de agua no debe exceder los 550 Kpa o 79 PSI

2.3.5 Velocidades

CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil


Velocidad Mnima

La velocidad mnima 0.6 m/s.

Velocidad Mxima

La velocidad mxima 2 m/s.


2.4 DESAGUES

2.4.1 Dimetros mnimos

Los dimetros mnimos para las tuberas de desage, tanto como horizontales, se
deben determinar a partir del nmero total de unidades de aparato para desage
de los aparatos conectados a dicha red. En el caso de los tubos de desage
verticales, adems del total de unidades de descarga, se debe considerar la
longitud, conforme a lo indicado en tabla 14 de la norma NTC1500.



2.4.2 Separacin mnima

Para los equipos que requieren desmontaje peridico se deben instalar uniones
que permitan esa operacin mximo 0.30m del equipo segn la NTC 1500

2.4.3 Cambios en direccin del Flujo

CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil


Los cambios de direccin de la tubera de desage deben hacerse con los
accesorios apropiados, codos de 45 y 90.

Las lneas horizontales de desage se conectara al tubo vertical por medio de Y,
Combinacin de Y y codo de 45, T u otros accesorios aprobados de Angulo
equivalente. No se debe usar ningn accesorio que tenga ms de una entrada al
mismo nivel, a menos que tal accesorio este construido de tal manera que la
descarga de una (1) entrada no
pueda confluir fcilmente en otra
entrada

Las lneas horizontales de desage
se conectarn a otras lneas
horizontales por medio de Y


2.4.4 Pendiente de la tubera
sanitaria horizontal

La pendiente de la tubera sanitaria
debe ser tal que garantice su
capacidad para evacuar el caudal de
diseo, con una velocidad
comprendida entre 0,6 m/s y 5 m/s.






2.4.5 Disposicin en relacin con redes de suministro de agua de agua
potable
Las tuberas exteriores de desage hechas de arcilla a de materiales que no son
aprobados para uso dentro de un edificio no se colocarn en la misma zanja de las
tuberas de suministro de agua potable, a menos que se cumplan las dos
condiciones siguientes

1) La cota batea de la tubera de suministro de agua potable, en toda su longitud,
debe estar por lo menos a 0,3 m por encima de la parte superior de la tubera de
desage

2) La tubera de suministro de agua potable debe estar colocada sobre un lecho
solido excavado en un lado de la zanja comn con un mnimo de distancia
horizontal de 0,3 m de la tubera de desage.
CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil




2.4.6 UBICACIN DE COLECTORES
Con excepcin de lo previsto en el numeral 8.17.2, el colector externo de desage
no debe estar ubicado en otra propiedad que no sea la servida por este colector;
as mismo, tampoco debe estar ubicado en los lugares que no cumplan con las
distancias mnimas indicadas en la tabla 16.



NOTA 1 Toda tubera de desage debe estar colocada mnimo a 15,2 m de
distancia de los tanques de abastecimiento de agua domestica. Esta distancia
puede ser reducida mnimo a 7,6 m cuando la tubera de desage est hecha de
materiales aprobados para ser usados dentro de un edificio

2.4.7 Esfuerzo cortante

Para las condiciones inciales de operacin de cada tramo, debe verificarse el
comportamiento auto limpiante del flujo, para lo cual es necesario utilizar el
criterio de esfuerzo cortante medio. Por lo tanto, debe establecerse que el valor
del esfuerzo cortante medio sea mayor o igual a 1,5 N/m2 (0,15 Kg/m2).

2.4.8 Bajantes, colectores y conexiones para aguas lluvias

Los desages de aguas lluvias no deben ser usados para ningn otro propsito.

Proteccin de bajantes. Las bajantes expuestas a sufrir deterioro por mal trato o dao
debern protegerse adecuadamente.

Desage de aguas lluvias combinado con desage de aguas negras, Los sistemas de
desages de aguas negras y de aguas lluvias deben estar totalmente separados dentro
de la construccin y hasta la caja final de conexin al alcantarillado combinado.

CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil


2.4.9 Limpieza

Las bajantes de aguas lluvias y colectores conectados a un sistema de alcantarillado
deben tener tapones de limpieza instalados en la base de las bajantes o colectores
externos antes de ser conectados con el colector principal.


2.4.10 Dimensionamiento de Bajantes aguas lluvias
Para definir las dimensiones de los desages principales se pueden utilizar las
Tablas 24 y 25
CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil



3. CALCULO REDES HIDRAULICAS

El suministro de agua potable se realizara presurizando las redes con un equipo
hidroneumtico.

Se proyecta la construccin de una red tipo cerrada, para alimentar los puntos de riego
ubicados alrededor de la cancha de futbol y la red interna de la batera sanitaria, la cual
funcionara con sanitarios tipo fluxmetro..

3.1 VOLUMEN DE RESERVA

El volumen de reserva est proyectado para abastecer el consumo de la batera
sanitaria y el riego de la cancha de futbol durante 24 horas.

DESCRIPCION CONSUMO UNIDAD
CANTIDAD
(UNIDADES/M)
HORAS MAX
ATENCION
DIA
CONSUMO
DIARIO
Sanitaros pblicos con fluxmetro 50 lt/hora 8 10 4000
Riego 2 Lt/m2 6400 12800
TOTAL 16800

El volumen de reserva de agua potable necesario es de 16800 litros equivalentes
al 100% del volumen total.
Este volumen se almacenara en un tanque bajo para realizar el abastecimiento por
presin mediante la instalacin de un equipo hidroneumtico.
3.2 ACOMETIDA

El centro deportivo del municipio de Sabanalarga Casanare, tiene proyectado un
volumen de reserva de 16800 Litros

Volumen total: 16.80 m3
Tiempo de llenado del Tanque 6.0 horas









CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil



Por esta razn tomamos el dimetro de medidor de 20 mm

Medidor de 20 mm

Para la acometida se asume un dimetro de 1 y se verifica si cumple dentro del rango de
velocidad




3.3 RUTA CRITICA

La evaluacion de la energia necesaria para el funcionamiento de las redes hidraulicas se
evaluo en dos rutas, la primer ruta corresponde al calculo de la energia necesaria para la
bateria sanitaria, y la segunda ruta corresponde ala red externa que alimenta la bateria
sanitaria y los puntos para riego de la cancha de futbol.

Ruta crtica No. 1 Bateria Sanitaria














CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil




Esquema 1 Ruta crtica suministro Batera Sanitaria
CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil


3.4 Tabla calculo red hidrulica batera sanitaria

3.5 Tabla calculo red hidrulica externa













Tabla 2 Ruta critica suministro Red externa
V
TOTAL J PRESIN
LTS/SEG INCH. mm MATERIAL M/S MTS. No. No. No. MTS.
1.00 10.00 1.00 10.00 1.69 1.25 42.16 1.00 0.0001 1.21 0.0292 0.1896 1.42 0.60 1 0.5 0.50 2.52 0.2227 16.462
2.00 20.00 1.00 20.00 2.19 1.25 42.16 1.00 0.0001 1.57 0.0460 0.1254 0.94 1 0.46 0.46 4.20 0.1932 16.781
3.00 30.00 0.71 22.00 2.27 1.25 42.16 1.00 0.0001 1.62 0.0488 0.1343 3.78 1 0.46 0.46 4.24 0.2071 17.122
4.00 34.00 1.00 34.00 1.69 1.25 42.16 1.00 0.0001 1.48 0.0471 0.1115 0.86 1 0.46 0.46 1.32 0.1379 17.372
5.00 38.00 0.50 19.00 2.14 1.5 48.26 1.00 0.0001 1.17 0.0233 0.0698 0.98 1 0.55 0.55 4.33 0.1007 17.542
6.00 42.00 0.45 19.00 2.14 1.5 48.26 1.00 0.0001 1.17 0.0233 0.0698 1.68 1 0.55 0.55 2.23 0.0519 17.664
13.00 88.00 0.29 26.00 2.42 1.5 48.26 1.00 0.0001 1.32 0.0288 0.0782 5.57 6 1 1 0.55 0.55 6.12 0.1573 17.899
24.00 156.00 0.21 33.00 2.65 2 60.32 1.00 150.0000 0.93 0.0146 1.0782 5.57 1 0.55 0.55 6.12 1.1573 20.135
Tees
Acces.
FACTOR
DE
SIMULTAN
EIDAD K1
UND. MX.
PROBABLES
TRAMO
NUMERO DE
APARATOS

TABLA - CLCULO RED HIDRAULICA INTERNA (RUTA CRITICA)
2-3
C
1-2
j
3-4
hv
HORIZONTAL-VERTICAL
H V
8-9
Codos Valvulas UNIDADES DE
CONSUMO
Q(CSM)
6-7
7-8
5-6
4-5
V
TOTAL J PRESIN
LTS/SEG INCH. mm MATERIAL M/S MTS. No. No. No. MTS.
24.00 156.00 0.21 33.00 2.65 2 60.32 1.00 150.0000 0.93 0.0146 0.1896 18.2 0.00 18.24 0.2227 20.135
24.00 156.00 0.21 33.00 2.65 2 60.32 1.00 150.0000 0.93 0.0146 0.1254 26.3 1 0.73 0.73 29.80 0.1932 20.454
24.00 166.00 0.21 35.00 2.65 2 60.32 1.00 150.0000 0.93 0.0146 0.1343 51.1 1 0.95 1 0.73 1.68 52.73 0.2071 20.795
24.00 166.00 0.21 35.00 2.65 2 60.32 1.00 150.0000 0.93 0.0146 0.1115 51.2 1 0.73 0.73 51.95 0.1379 21.044
24.00 166.00 0.21 35.00 2.65 2 60.32 1.00 150.0000 0.93 0.0146 0.0698 5.28 1 0.73 0.73 8.81 0.1007 21.215
24.00 166.00 0.21 35.00 2.65 2 60.32 1.00 150.0000 0.93 0.0146 0.0698 10.9 1 0.95 1 0.73 1.68 12.55 0.0519 21.336
1-2
2-3
3-4
4-5
5-9
9-10
j hv
HORIZONTAL-VERTICAL
H V
Codos Valvulas Tees
Acces.
TABLA - CLCULO RED HIDRAULICA (RUTA CRITICA)
TRAMO
NUMERO DE
APARATOS
UNIDADES DE
CONSUMO
FACTOR
DE
SIMULTAN
EIDAD K1
UND. MX.
PROBABLES
Q(CSM) C
CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil



CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil


3.6 EVALUACIN POTENCIA EQUIPO

La altura dinmica para la evaluacin de la potencia de los equipos de bombeo se
compone de la presin necesaria en la red para dar servicio al aparato sanitario
ms alejado y de mayor consumo, ms la altura dinmica de succin en la
instalacin de

Impulsion

Las prdidas por accesorios y friccin en cada tramo para calcular la altura de
impulsin se toma de la tabla de clculo de las redes externas correspondiente a
22.40 mca.

Las prdidas en el equipo de presin se establecen segn las siguientes
condiciones:

MATERIAL HIERRO GALVANIZADO C= 100

Caudal de diseo

Qdiseo= 0,00133 m3/s
Tuberia de impulsin

Di= 0,0437 m
Di (Ds)= 0,04368 m
Vi= 0,89 m/s
Prdidas en la impulsin

Expansin conctrica (12D) 0,52

Vlvula de retencin horizontal 6,40

Vlvula de cortina 0,4

Codo de radio corto de 90 (cuatro codos) 6,8

Te con cambio de direccim 3,5

Tubera horizontal EPK = 5

Longitud equivalente total 22,62 m

Prdida de carga total




J= 0,04174


Prdidas en la impulsin=

J x Longitud equivalente Total 0,94 m
CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil





Se asume una prdida de 1.0 mca en el equipo de presin.

Calculo de la succin:

Tubera de Succin

Di= 0,0437 m

Di (Ds)= 0,04368 m
se toma 1 1
/2" por
diametro de la
bomba
Vi= 0,89 m/s



Prdidas en la succin

Vlvula de pie en coladera 1 1/2" cobre 7,49

Codo de radio corto 90 1 1/2 HG 1,30

Entrada (borda) 1,00

Longitud de tuberia horizontal HG 1,00

Longitud de tuberia vertical HG 2,50

Longitud equivalente total 13,29 m


Prdida de carga total





J= 0,04174


*Altura de velocidad en la descarga (Vi)



0,04 m


Prdidas en la succion=

J x Longitud equivalente Total 0,55 m

Altura dinmica succin 3,09 m



CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil




Altura Dinamica total

Corresponde a la sumatoria de la energa necesaria en la succin, impulsin
en el tramo inicial del equipo en tubera HG, y la energa evaluada en la red
exterior.



Succin EPK 3.10
Impulsion EPK 1.00
Red exterior 22.40
Altura dinmica total 26.50

Calculo de la potencia


Se calcula con una altura de 26.50 m


0.77 hp


= Peso especfico del Agua = 1 kg/l
Ht = Altura dinmica Total = 26.5 m
Q = caudal = 1.33 l/s para cada bomba
Constante de Conversin = 76
= Eficiencia = 65%


Se utilizara dos bombas de 1 HP, la primera para el consumo mnimo y la
segunda como refuerzo.









n
QH
P
t
hp
76

CARLOS ANDRES MENDOZA RINCON


Ingeniero Civil



3.7 EVALUACION EQUIPO DE PRESION CONSTANTE


SISTEMA DE SUMINISTRO 1
Evaluacin Salidas
Nmero de salidas primer piso
Se considera cada mueble como una salida
Batera sanitaria x 24 salidas = 24 salidas
TOTAL 24 salidas

Capacidad del equipo
Factor multiplicador hasta 40 = 1.20
Capacidad 24 x 1.2 = 28.8 = 29 gal/min =110 L/min
Presin de trabajo = 30 50 PSI
Potencia equipos comerciales = 1 hp
Volumen de regulacin
Hipotesis
Qon = 29 gal/min
Qof = 25%Qon = 7.25 gal/min
Qmed = 18.125 gal/min

Ciclo de apagado y encendido recomendado para una potencia entre 1 a 3 hp, numero de
ciclos 50, y tiempo del ciclo 1.2 min

4
*T Qpromedio
n Vregulaci
4
2 . 1 * 125 . 18
= 5.44 Gal = 21 litros

Volumen del tanque

P = Presin absoluta = P. Manomtrica + P. Atmosfrica = 30.6 +14.7 = 45.32 psi

El equipo de presin trabaja en un Rango de presin de 30 50 psi

Factor




Para un rango de presin de 30-50 psi
CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil



F = 3.23
VT = 3.23 X Vr = 3.23 x 20 Litros = 67.83 litros , se toman 68 litros


VOLUMEN HIDRONEUMATICO




Vr = 21 litros
PA = 50/14.7 + 1 = 3.43 +1 = 4.43 atm
P1 =50/14.7 = 3.43 atm
P2 =30 /14.7 = 2.04 atm

04 . 2 43 . 3
43 . 4 * 21

Vhc =78.17=79 litros



Volumen de la bolsa con la presin de corte

Vbc = Volumen de la bolsa corregido
Pc = Presin de corte 55 PSI = 3.74 atm
Vhc = Volumen precargado = 79 litros










1 74 . 3
04 . 2 74 . 3
79

Vhc =28.33

Se requieren un equipo con una capacidad mayor a 30 gal/min, para trabajar
en un rango de presin entre 30 a 50 PSI, un volumen del tanque
hidroneumtico de 100 litros de acuerdo a especificaciones comerciales.









CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil





4. EVALUACION DESAGUES DE AGUAS NEGRAS
EVALUACION DE CAUDALES EN COLECTORES
Para la evaluacin de caudales en los colectores

Colector 1-2

Este colector recoge el desage de la batera sanitaria para hombres:

1Inodoro de fluxmetro x 10 = 10
1lavamanos de llave: x 4 = 4
1Ducha: x 4 = 4

Total Unidades propias = 18 unidades
Caudal equivalente = 1.69 l/s


Colector 2-3


2 Orinales tanque de fluxmetro x 10 = 20
3 Lavamanos de Llave: x 4 = 12



Unidades propias = 32 unidades
Total Unidades = 50 unidades
Caudal equivalente = 3.22 l/s



Colector 3-4


3 Inodoro tanque de fluxmetro x 10 = 30
3 Ducha: x 4 = 12

Unidades propias = 42 unidades
Unidades Acumuladas = 92 unidades
CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil


Total Unidades = 92 unidades
Caudal equivalente = 4.05 l/s






Colector 4 - 8


3 Inodoro tanque de fluxmetro x 10 = 30
3 Ducha: x 4 = 12

Unidades propias = 42 unidades
Unidades Acumuladas = 92 unidades
Total Unidades = 92 unidades
Caudal equivalente = 4.05 l/s


Colector 5-6

Este colector recoge el desage de la batera sanitaria para mujeres:

1Inodoro de fluxmetro x 10 = 10
1lavamanos de llave: x 4 = 4
1Ducha: x 4 = 4

Total Unidades propias = 18 unidades
Caudal equivalente = 1.69 l/s


Colector 6-7


3 Lavamanos de Llave: x 4 = 12



Unidades propias = 12 unidades
Total Unidades = 30 unidades
Caudal equivalente = 2.56 l/s



CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil


Colector 7-8


3 Inodoro tanque de fluxmetro x 10 = 30
3 Ducha: x 4 = 12

Unidades propias = 42 unidades
Unidades Acumuladas = 72 unidades
Total Unidades = 72 unidades
Caudal equivalente = 3.6 l/s



Colector 8-PSE1

Unidades propias = 0 unidades
Unidades Acumuladas = 164 unidades
Total Unidades = 164 unidades
Caudal equivalente = 2.64 l/s


CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil


Coeficiente de Manning PVC: 0.009
Longitud S QLl VLl QDT/QLl V/VLl d/D V V2/2g d E H/D H NF RH ANGULO T
DE A PROPIAS ACUM.
[2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] [13] [14] [15] [16] [17] [18] [19] [20] [21] [22] [23] [24] [25]
CI-01 CI-02 18.0 18.0 0.2 4 1.690 3.650 1.0 0.1 2.3 4.0 0.1 7.469 0.950 0.23 0.677 0.367 0.643 0.021 0.040 0.061 0.270 0.027 1.239 0.022 2.739 0.220
CI-02 CI-03 53.0 53.0 0.2 11 1.690 3.550 1.0 0.1 2.3 4.0 0.1 7.469 0.950 0.23 0.677 0.367 0.643 0.021 0.040 0.061 0.270 0.027 1.239 0.022 2.739 0.220
CI-03 CI-04 92.0 92.0 0.2 18 2.090 2.640 1.0 0.1 2.4 5.0 0.1 15.035 1.130 0.14 0.589 0.288 0.666 0.023 0.040 0.063 0.204 0.026 1.320 0.022 2.352 0.224
CI-04 CI-08 92.0 92.0 0.2 18 2.090 2.370 1.0 0.1 2.4 6.0 0.2 22.020 1.250 0.10 0.530 0.240 0.663 0.022 0.040 0.062 0.166 0.025 1.332 0.024 2.171 0.238
CI-05 CI-06 18.0 18.0 0.2 4 1.690 3.650 1.0 0.1 2.3 5.0 0.1 15.035 1.130 0.11 0.556 0.260 0.629 0.020 0.030 0.050 0.181 0.023 1.325 0.017 2.004 0.175
CI-06 CI-07 33.0 33.0 0.2 7 1.690 3.550 1.0 0.1 2.3 6.0 0.2 22.020 1.250 0.08 0.501 0.217 0.626 0.020 0.030 0.050 0.148 0.023 1.333 0.018 1.855 0.185
CI-07 CI-08 72.0 72.0 0.2 14 1.910 2.640 1.0 0.1 2.4 5.0 0.1 15.035 1.130 0.13 0.577 0.277 0.652 0.022 0.040 0.062 0.194 0.025 1.325 0.022 2.352 0.224
CI-08 PS-00 164.0 164.0 0.2 33 2.648 5.800 1.0 0.1 2.7 6.0 0.2 22.020 1.250 0.12 0.570 0.270 0.713 0.026 0.040 0.066 0.188 0.029 1.344 0.024 2.171 0.238
K1
UNIDADES
MAXIMAS
PROBABLE
S
PTO
[1]
Dimetro
(in) (m) (L/s) (m/s)
CAUDAL
MAXIMO
INSTANTANEO
m % (m) (in)
D Comercial CAUDAL
PARQUE SABANALARGA
EVALUACIN DE CAUDALES Y CONDICIONES HIDRULICAS RED DE DESAGES
TABLA N 2
UNIDADES
(m) (kg/m2) (m/s) (m) (m) (m)
4.1 EVALUACIN DE CAUDALES Y CONDICIONES HIDRULICAS RED DE DESAGES



Tabla No 6.2 Evaluacin de caudales y condiciones hidrulicas red de desages
CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil


5. EVALUACION DESAGUES AGUAS LLUVIAS

El dimensionamiento y evaluacin de los elementos proyectados para el manejo
de las aguas lluvias se realiz de acuerdo a la norma NTC1500.

La evaluacin se realiz para cada uno de los siguientes componentes del centro
deportivo:

Desage aguas lluvias cubierta graderas

Desage aguas lluvias cubierta cancha mltiple y cubierta batera sanitaria

Desage aguas lluvias cancha de futbol principal

Desage aguas lluvias cancha sinttica

5.1 Desage aguas lluvias cubierta graderas

El caudal de aguas lluvias interceptadas en la cubierta de la edificacin se
recolectaran en 8 bajantes de dimetro de 4 pulgadas, las cuales fueron
dimensionada segn su rea aferente, Estas a su vez entregaran el agua a un
sistema compuesto por canales, tuberas y cajas de inspeccin al sistema de
alcantarillado pluvial

CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil





Evaluacin de caudales bajantes aguas lluvias


Clase de Tuberia: PVC
Intensidad Lluva 150 mm/h
CAUDAL
PROPIA ACUM MAX Q L

M2 M2 M2 LPS M
PULG
1 69.52 69.52 214 2.898984 3.98 4
2 104.41 104.41 214 4.353897 3.98 4
3 109.83 109.83 214 4.579911 3.98 4
4 109.73 109.73 214 4.575741 3.98 4
5 108.94 108.94 214 4.542798 3.98 4
6 104.58 104.58 214 4.360986 3.98 4
7 105.23 105.23 214 4.388091 3.98 4
8 73.56 73.56 214 3.067452 3.98 4
DIMENSIN
EDIFICIO GRADERIAS CANCHA DE FUTBOL
NUMERO
DE LA
BAJANTE
AREA
CLCULO DE BAJANTES DE AGUAS LLUVIAS
CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil


Evaluacin de caudales red colectores aguas lluvias graderas






CENTRO DEPORTIVO Y RECREATIVO DEL MUNICIPIO DE SABANALARGA
Coeficiente de Escorrentia cubiertas y zonas duras: 0,95
Intensidad de Diseo: 150 mm/hr
rea C
I Q
Q
acumulado
TIPO DE
CANAL
MATERIAL Longitud
DE A No Ha L/s_Ha (L/s) (m) (in) (m)
C2-12 C2-13 0,007 0,95 150
2,75 2,75
CIRCULAR PVC 9,40 4 0,10
C2-13 C2-14 0,010 0,95 150
4,14 6,89
CIRCULAR PVC 10,96 4 0,10
C2-14 C2-15 0,011 0,95 150
4,35 11,24
CIRCULAR PVC 9,27 4 0,10
C2-15 C2-16 0,011 0,95 150
4,35 15,59
CIRCULAR PVC 11,87 4 0,10
C2-16 C2-17 0,011 0,95 150
4,32 19,90
CIRCULAR PVC 9,41 4 0,10
C2-17 C2-19 0,010 0,95 150
4,14 24,05
CIRCULAR PVC 11,81 4 0,10
C2-18 C2-19 0,011 0,95 150
4,17 4,17
CIRCULAR PVC 8,42 4 0,10
C2-19 PL-01 0,007 0,95 150
2,91 31,13
CIRCULAR PVC 12,89 4 0,10
TRAMO D Comercial
TABLA N 1
EVALUACIN DE CAUDALES
CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil






Tabla No 2 Parmetros hidrulicos aguas lluvias colectores aguas lluvias graderas








Coeficiente de Rugosidad PVC k 1,50E-06 m
Coeficiente de Rugosidad CONCRETO k 6,00E-04 m
Viscocidad cinematica agua a 20 C 1,02E-06 m/s
MATERIAL Q So Yn
ANCHO
DIAMETRO D/2 A P R V T NF
m/s m/m m m m rad m m m m m/s N/m
C2-12 C2-13 PVC 0,003 0,0150 0,031 N/A 0,1016 0,0508 2,35 0,002 0,119 0,018 1,30 2,60
2,774
C2-13 C2-14 PVC 0,007 0,0150 0,047 N/A 0,1524 0,0762 2,36 0,005 0,180 0,027 1,43 3,94
2,465
C2-14 C2-15 PVC 0,011 0,0150 0,064 N/A 0,1524 0,0762 2,81 0,007 0,214 0,034 1,55 4,97
2,261
C2-15 C2-16 PVC 0,016 0,0150 0,075 N/A 0,1524 0,0762 3,12 0,009 0,238 0,038 1,73 5,56
2,281
C2-16 C2-17 PVC 0,020 0,0150 0,075 N/A 0,2032 0,1016 2,62 0,011 0,266 0,041 1,82 6,04
2,469
C2-17 C2-19 PVC 0,024 0,0150 0,083 N/A 0,2032 0,1016 2,78 0,012 0,282 0,044 1,92 6,52
2,458
C2-18 C2-19 PVC 0,004 0,0150 0,039 N/A 0,1016 0,0508 2,66 0,003 0,135 0,021 1,47 3,08
2,776
C2-19 PL-01 PVC 0,031 0,0150 0,096 N/A 0,2032 0,1016 3,03 0,015 0,308 0,049 2,06 7,21 2,414
TRAMO
RED AGUAS LLUVIAS PARQUE SABANALARGA
CALCULO TIRANTE MEDIO
TABLA No. 2
CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil


5.2 Desage aguas lluvias cubierta cancha mltiple y cubierta batera
sanitaria

El caudal de aguas lluvias interceptadas en la cubierta de la edificacin se
recolectaran en 2 bajantes de dimetro de 3 pulgadas, las cuales fueron
dimensionada segn su rea aferente, Estas a su vez entregaran el agua a un
sistema compuesto por canales, tuberas y cajas de inspeccin al sistema de
alcantarillado pluvial

Con respecto a la cubierta de la cancha mltiple se compone de canales en lamina
de acero, 7 bajantes en tubera , y un colector compuesto de cajas de inspeccin y
tubera que a su vez recibe el agua proveniente de la cubierta de la batera
sanitaria, para su disposicin final a las redes externas de alcantarillado pluvial .



Evaluacin de caudales bajantes aguas lluvias batera sanitaria












Clase de Tuberia: PVC
Intensidad Lluva 150 mm/h
CAUDAL
PROPIA ACUM MAX Q L

M2 M2 M2 LPS M
PULG
1 85.26 85.26 100 3.555342 6.94 3
2 85.26 85.26 100 3.555342 6.94 3
EDIFICIO BATERIA SANITARIA
CLCULO DE BAJANTES DE AGUAS LLUVIAS
NUMERO
DE LA
BAJANTE
AREA DIMENSIN
CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil




Evaluacin de caudales bajantes aguas lluvias cancha mltiple


Clase de Tuberia: PVC
Intensidad Lluva 150 mm/h
CAUDAL
PROPIA ACUM MAX Q L

M2 M2 M2 LPS M
PULG
1 90.47 90.47 214 3.772599 6.94 4
2 176.38 176.38 214 7.355046 6.94 4
3 173.56 173.56 214 7.237452 6.94 4
4 93.28 93.28 214 3.889776 6.94 4
5 136.25 136.25 214 5.681625 6.94 4
6 262.67 262.67 214 10.953339 6.94 4
7 134.78 134.78 214 5.620326 6.94 4
EDIFICIO CANCHA MULTIPLE
CLCULO DE BAJANTES DE AGUAS LLUVIAS
NUMERO
DE LA
BAJANTE
AREA DIMENSIN
CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil










Tabla No 1 Evaluacin de caudales colectores cancha mltiple

Coeficiente de Escorrentia cubiertas y zonas duras:0,95
Coeficiente de Escorrentia Parqueaderos: 0,75
Intensidad de Diseo: 150 mm/hr
rea C
I Q
Q
acumulado
TIPO DE
CANAL
MATERIAL Longitud Pendiente
DE A Ha L/s_Ha (L/s) (m) % (in) (m)
C2-22 C2-23 0,008 0,95 150
3,29 3,29
CIRCULAR PVC 9,40 1,00 4 0,10
C2-23 C2-24 0,008 0,95 150
3,29 6,57
CIRCULAR PVC 10,96 1,00 4 0,10
C2-24 C2-25 0,019 0,95 150
7,50 14,07
CIRCULAR PVC 9,27 1,00 4 0,10
C2-25 C2-26 0,019 0,95 150
7,50 21,57
CIRCULAR PVC 11,87 1,00 4 0,10
C2-26 PL-02 0,019 0,95 150
7,50 29,07
CIRCULAR PVC 11,81 1,00 4 0,10
CENTRO DEPORTIVO Y RECREATIVO DEL MUNICIPIO DE SABANALARGA
EVALUACIN DE CAUDALES
TABLA N 1
D Comercial TRAMO
CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil







Tabla 2 Evaluacin parmetros hidrulicos colectores cancha mltiple









Coeficiente de Rugosidad PVC k 1,50E-06 m
Coeficiente de Rugosidad CONCRETO k 6,00E-04 m
Viscocidad cinematica agua a 20 C 1,02E-06 m/s
MATERIAL Q So Yn DIAMETRO D/2 A P R V T NF
m/s m/m m m rad m m m m m/s N/m
C2-22 C2-23 PVC 0,003 0,0100 0,038 0,1016 0,0508 2,65 0,003 0,135 0,021 1,17 2,05
2,212
C2-23 C2-24 PVC 0,007 0,0100 0,053 0,1524 0,0762 2,51 0,006 0,191 0,029 1,18 2,86
1,921
C2-24 C2-25 PVC 0,014 0,0100 0,079 0,1524 0,0762 3,20 0,009 0,244 0,039 1,48 3,81
1,899
C2-25 C2-26 PVC 0,022 0,0100 0,108 0,1524 0,0762 4,01 0,014 0,305 0,045 1,56 4,45
1,571
C2-26 PL-02 PVC 0,029 0,0100 0,104 0,2032 0,1016 3,18 0,017 0,323 0,051 1,75 5,05 1,947
RED AGUAS LLUVIAS PARQUE SABANALARGA
CALCULO TIRANTE MEDIO COLECTORES CIRCULARES
TABLA No. 2
TRAMO
CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil



CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil


5.3 Desage aguas lluvias cancha de futbol principal

El desage de la cancha se compone de los elementos necesario para evacuar la
escorrenta superficial y el agua infiltrada mediante un sistema de filtracin.

El mtodo de clculo de caudales es el mtodo racional

El mtodo empleado para el diseo es el racional que establece que el caudal
superficial producido por una precipitacin es:

Q = 2.78 C x I x A

Dnde:
Q = Caudal superficial (L/s)
C = Coeficiente de escorrenta (adimensional)
I = Intensidad promedio de la lluvia (mm/Hr)
A = rea de drenaje (Ha)
Intensidad de la lluvia
Para la evaluacin de os desages de aguas lluvias de la cancha se evaluara la
precipitacin ms fuerte utilizada en el pre dimensionamiento de colectores de la
NTC 1500 de 150 mm/hr.

Coeficiente de escorrenta

De acuerdo a la condiciones de la cancha se evalu un coeficiente de escorrenta
teniendo en c














Se asumir como coeficiente de escorrenta 0.32, y el 0.63 restante se asumir
como factor de permeabilidad para el clculo de los caudales a evacuar mediante
filtros y colectores.
CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil


rea de drenaje

Corresponde al rea de la terraza en donde se conformara la cancha as mismo
delas sub reas aferentes a cada tramo de los colectores de desage.

Depende de las condiciones geomtricas del terreno y el sistema de recoleccin
adoptado, para la evacuacin de las aguas infiltradas en la cancha de futbol se
seleccion un sistema de filtros perpendiculares, en direccin a cada costado de la
cancha donde se dispone de cajas de inspeccin y tubera para la evacuacin total
de las aguas interceptadas en la cancha.



















Distribucin drenaje cancha de futbol















7
0
. 0
0
111.00
29.65
3 6 . 0 0
81.18
4 . 2 0
CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil


Seccin trasversal filtro
CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil




Evaluacin caudales y parmetros hidrulicos colector aguas lluvias cancha de futbol







Rugosidad absoluta PVC 1,50E-06 m
Rugosidad absoluta CONCRETO 6,00E-04 m
Viscocidad cinematica agua a 20 C 1,02E-06 m/s
Q So Yn DIAMETRO A P R V T T NF
PROPIA ACUM. m/s
m/m m m rad
m
m m m/s
N/m
m
[2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] [13] [14] [15] [16] [17] [18]
C-01 C-02 0,04 0,04 0,63 150,00 PVC 0,009 0,0050 0,082 0,1450 3,41 0,010 0,247 0,039 0,95 1,92 0 , 1 4
1,172
C-02 C-03 0,04 0,07 0,63 150,00 PVC 0,018 0,0050 0,101 0,1820 3,36 0,015 0,305 0,048 1,24 2,37 0 , 1 8
1,391
C-03 C-04 0,04 0,11 0,63 150,00 PVC 0,028 0,0050 0,131 0,1820 4,05 0,020 0,368 0,054 1,38 2,67 0 , 1 6
1,257
CI-04 C-05 0,04 0,14 0,63 150,00 PVC 0,037 0,0050 0,161 0,1820 4,91 0,024 0,447 0,055 1,51 2,68 0 , 1 2
1,045
C-05 C-06 0,04 0,18 0,63 150,00 PVC 0,046 0,0050 0,157 0,2270 3,92 0,030 0,445 0,067 1,54 3,28 0 , 2 1
1,306
C-06 C-07 0,04 0,21 0,63 150,00 PVC 0,055 0,0050 0,176 0,2270 4,31 0,034 0,489 0,069 1,64 3,38 0 , 1 9
1,238
C-07 C-08 0,04 0,25 0,63 150,00 PVC 0,064 0,0050 0,177 0,2840 3,64 0,041 0,516 0,080 1,55 3,94 0 , 2 8
1,278
C-08 C-09 0,04 0,28 0,63 150,00 PVC 0,074 0,0050 0,195 0,2840 3,91 0,046 0,555 0,084 1,58 4,10 0 , 2 6
1,203
C-09 C-10 0,04 0,32 0,63 150,00 PVC 0,083 0,0050 0,214 0,2840 4,21 0,051 0,598 0,086 1,61 4,21 0 , 2 4
1,124
C-10 C-11 0,04 0,35 0,63 150,00 PVC 0,092 0,0050 0,237 0,2840 4,60 0,056 0,654 0,086 1,63 4,23 0 , 2 1
1,114
C-11 CANAL 0,04 0,39 0,63 150,00 PVC 0,101 0,0075 0,211 0,2840 4,16 0,051 0,591 0,086 2,00 6,29 0 , 2 5
1,413
[1]
TRAMO AREA
MATERIAL C I
CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil


Evaluacin cuneta rectangular y colector final

El caudal de aguas lluvias proveniente de los filtros finalmente es entregada a un canal
rectangular para su posterior entrega a la red de alcantarillado pluvial mediante un
colector circular, a continuacin se presenta la evaluacin del canla retangular y del
colector final que se conecta a les rede s de alcantarillado pluvial.

Para el clculo de la seccin normal del canal, en la tabla siguiente se presentan las
relaciones geomtricas utilizadas.

Relaciones geomtricas de las secciones transversales



EL DIMENSIONAMIENTO SE REALIZ CON LA ECUACIN QUE COMBINA LAS ECUACIONES DE
DARCY WEISBACH Y COLEBROOK WHITE.


]

Q = CAUDAL DEL FLUJO EN M/S
KS = RUGOSIDAD ABSOLUTA DEL CANAL EN M
R = RADIO HIDRULICO EN M
A = REA MOJADA TRANSVERSAL EN M
S = PENDIENTE LONGITUDINAL DEL TRAMO EN M/M
V = VISCOSIDAD CINEMTICA EN M/S
CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil


Canal rectangular

A continuacin se describe cada una de las columnas que comprende el clculo del canal


















N DESCRIPCIN
[1] Tramo de Colector
[2] Material
[3] Caudal
[4] Pendiente colector
[5] Tirante medio
[6] Ancho canal rectangular
[7] rea mojada
[8] Permetro mojado
[9] Radio hidrulico
[10] Velocidad media
[11] Esfuerzo cortante medio
[12] Numero de froude
CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil

































k 1,50E-06 m
k 4,00E-04 m
1,02E-06 m/s
Q So Yn ANCHO A P R V T NF
m/s
m/m m
m m
m m m/s
N/m
[1] [2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12]
CANAL 1 CONCETO 0,383 0,0050 0,416 0,500 0,208 1,332 0,156 1,84 7,66
1,120
TRAMO MATERIAL
RED AGUAS LLUVIAS UNIVERSIDAD DE LOS LLANOS SEDE SAN
CALCULO TIRANTE MEDIO CANAL RECTANGULAR
Coeficiente de Rugosidad PVC
Coeficiente de Rugosidad CONCRETO
Viscocidad cinematica agua a 20 C
CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil



CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil


Colectores de entrega

A continuacin se describe cada una de las columnas que comprende el clculo del
colector















N DESCRIPCIN
[1] Tramo de Colector
[2] rea propia
[3] rea acumulada
[4] Coeficiente de escorrenta
[5] Intensidad de la lluvia
[6] Material
[7] Caudal
[8] Pendiente colector
[9] Tirante medio
[10] Dimetro
[11] Angulo entre el espejo de agua y el centro de la
tubera
[12] rea mojada
[13] Permetro mojado
[14] Radio hidrulico
[15] Velocidad media
[16] Esfuerzo cortante medio
[17] Espejo de agua
[18] Numero de froude
CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil
























Rugosidad absoluta PVC 1,50E-06 m
Rugosidad absoluta CONCRETO 6,00E-04 m
Viscocidad cinematica agua a 20 C 1,02E-06 m/s
Q So Yn DIAMETRO A P R V T T NF
PROPIA ACUM. m/s
m/m m m rad
m
m m m/s
N/m
m
[2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] [13] [14] [15] [16] [17] [18]
CANAL PL-03A 0,25 1,02 0,90 150,00 PVC 0,383 0,0300 0,256 0,3620 3,99 0,078 0,723 0,108 4,92 31,65 0 , 3 3
3,235
PL03A PL-03 0,05 1,07 0,90 150,00 PVC 0,401 0,0500 0,217 0,3620 3,55 0,065 0,642 0,101 6,22 49,31 0 , 3 5
4,657
[1]
TRAMO AREA
MATERIAL C I
CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil



Evaluacin canales semicirculares laterales

Los caudales de escorrenta se evacuaran mediante dos canales semicirculares
laterales en concreto esmaltado ubicados en cada costado de la cancha
proyectados con una pendiente mnima de 0.55%.

El canal semicircular presenta al siguiente seccin trasversal:













A continuacin se describe cada una de las columnas que comprende el clculo del
CANAL SEMICIRCULAR

















N DESCRIPCIN
[1] Tramo de Colector
[2] rea propia
[3] rea acumulada
[4] Coeficiente de escorrenta
[5] Intensidad de la lluvia
[6] Material
[7] Caudal
[8] Pendiente colector
[9] Tirante medio
[10] Dimetro
[11] Angulo entre el espejo de agua y el centro de la
tubera
[12] rea mojada
[13] Permetro mojado
[14] Radio hidrulico
[15] Velocidad media
[16] Esfuerzo cortante medio
[17] Espejo de agua
[18] Numero de froude
CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil








EVALAVULACION PARAMETROS HIDRAULICOS CANAL SEMICIRCULAR EN CONCRETO

Rugosidad absoluta PVC 1,50E-06 m
Rugosidad absoluta CONCRETO ENCOFRADO METALICO 2,50E-04 m
Viscocidad cinematica agua a 20 C 1,02E-06 m/s
Q So Yn DIAMETRO A P R V T T NF
PROPIA ACUM. m/s
m/m m m rad
m
m m m/s
N/m
m
[2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] [13] [14] [15] [16] [17] [18]
0,32 0,32 0,32 150,00 CONCRETO 0,043 0,0550 0,077 0,3000 2,12 0,014 0,319 0,045 2,98 24,27 0 , 2 6
4,062
[1]
CANAL SM
TRAMO AREA
MATERIAL C I
CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil



5.4 Desage aguas lluvias cancha sinttica


El desage de la cancha se compone de los elementos necesario para evacuar la
escorrenta superficial y el agua infiltrada mediante un sistema de filtracin.

El mtodo de clculo de caudales es el mtodo racional

El mtodo empleado para el diseo es el racional que establece que el caudal
superficial producido por una precipitacin es:

Q = 2.78 C x I x A

Dnde:
Q = Caudal superficial (L/s)
C = Coeficiente de escorrenta (adimensional)
I = Intensidad promedio de la lluvia (mm/Hr)
A = rea de drenaje (Ha)
Intensidad de la lluvia
Para la evaluacin de os desages de aguas lluvias de la cancha se evaluara la
precipitacin ms fuerte utilizada en el pre dimensionamiento de colectores de la
NTC 1500 de 150 mm/hr.

Coeficiente de escorrenta

De acuerdo a la condiciones de la cancha se evalu un coeficiente de escorrenta
teniendo en c














CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil



CLCULO RED DE DESAGES


Se asumir como coeficiente de escorrenta 0.32, y el 0.63 restante se asumir
como factor de permeabilidad para el clculo de los caudales a evacuar mediante
filtros y colectores.

rea de drenaje

Corresponde al rea de la terraza en donde se conformara la cancha as mismo
delas sub reas aferentes a cada tramo de los colectores de desage.

Depende de las condiciones geomtricas del terreno y el sistema de recoleccin
adoptado, para la evacuacin de las aguas infiltradas en la cancha sinttica se
seleccion un sistema de filtros perpendiculares, en direccin a un costado, los
cuales entregan a un colector compuesto de cajas de inspeccin y tubera PVC.
















Distribucin filtros cancha sinttica













Seccin trasversal filtro
CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil



CLCULO RED DE DESAGES









rea C I Q
Q
acumulado
TIPO DE
CANAL
MATERIAL Longitud
Pendiente
canal
DE A Ha L/s_Ha (L/s) (m) % (in) (m)
C2-27 C2-28 0,004 0,63 150 1,05 1,05 CIRCULAR PVC 15,50 1,00 4 0,10
C2-28 C2-29 0,004 0,63 150
1,05 2,10
CIRCULAR PVC 1,90 1,00 6 0,15
C2-29 C2-30 0,004 0,63 150
1,05 3,15
CIRCULAR PVC 1,90 1,00 6 0,15
C2-30 C2-31 0,004 0,63 150
1,05 4,20
CIRCULAR PVC 1,90 1,00 6 0,15
C2-31 C2-32 0,004 0,63 150
1,05 5,25
CIRCULAR PVC 1,90 1,00 8 0,20
C2-32 C2-33 0,004 0,63 150
1,05 6,31
CIRCULAR PVC 1,90 1,00 8 0,20
C2-33 C2-34 0,004 0,63 150
1,05 7,36
CIRCULAR PVC 1,90 1,00 8 0,20
C2-34 C2-35 0,004 0,63 150
1,05 8,41
CIRCULAR PVC 1,90 1,00 8 0,20
C2-35 C2-36 0,004 0,63 150
1,05 9,46
CIRCULAR PVC 1,90 1,00 8 0,20
C2-36 C2-37 0,004 0,63 150
1,05 10,51
CIRCULAR PVC 1,90 1,00 8 0,20
C2-37 PL-03A 0,004 0,63 150 1,05 11,56 CIRCULAR PVC 2,33 1,00 8 0,20
TABLA N 1
TRAMO D Comercial
CENTRO DEPORTIVO Y RECREATIVO DEL MUNICIPIO DE SABANALARGA
EVALUACIN DE CAUDALES
Coeficiente de Rugosidad PVC k 1,50E-06 m
Coeficiente de Rugosidad CONCRETO k 6,00E-04 m
Viscocidad cinematica agua a 20 C 1,02E-06 m/s
MATERIAL Q So Yn DIAMETRO D/2 A P R V T NF
m/s m/m m m rad m m m m m/s N/m
C2-27 C2-28 PVC 0,001 0,0100 0,031 0,1016 0,0508 2,35 0,002 0,119 0,018 0,50 1,74
1,059
C2-28 C2-29 PVC 0,002 0,0100 0,033 0,1524 0,0762 1,95 0,003 0,149 0,020 0,71 1,96
1,472
C2-29 C2-30 PVC 0,003 0,0100 0,040 0,1524 0,0762 2,15 0,004 0,164 0,023 0,83 2,28
1,569
C2-30 C2-31 PVC 0,004 0,0100 0,046 0,1524 0,0762 2,33 0,005 0,178 0,026 0,90 2,58
1,570
C2-31 C2-32 PVC 0,005 0,0100 0,047 0,2032 0,1016 2,00 0,006 0,204 0,028 0,93 2,73
1,631
C2-32 C2-33 PVC 0,006 0,0100 0,051 0,2032 0,1016 2,11 0,006 0,214 0,030 0,98 2,95
1,635
C2-33 C2-34 PVC 0,007 0,0100 0,027 0,2032 0,1016 1,49 0,003 0,152 0,017 2,86 1,66
6,705
C2-34 C2-35 PVC 0,008 0,0100 0,059 0,2032 0,1016 2,28 0,008 0,232 0,034 1,07 3,33 1,648
C2-35 C2-36 PVC 0,009 0,0100 0,062 0,2032 0,1016 2,35 0,008 0,239 0,035 1,12 3,47
1,686
C2-36 C2-37 PVC 0,011 0,0100 0,062 0,2032 0,1016 2,33 0,008 0,237 0,035 1,27 3,43
1,922
C2-37 PL-03A PVC 0,012 0,0100 0,067 0,2032 0,1016 2,45 0,009 0,248 0,037 1,24 3,68
1,796
RED AGUAS LLUVIAS PARQUE SABANALARGA
CALCULO TIRANTE MEDIO
TABLA No. 2
TRAMO
CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil



CLCULO RED DE DESAGES




Evaluacin canales semicirculares laterales

Los caudales de escorrenta se evacuaran mediante dos canales semicirculares
laterales en concreto esmaltado ubicados en cada costado de la cancha
proyectados con una pendiente mnima de 0.55%.

El canal semicircular presenta al siguiente seccin trasversal:













A continuacin se describe cada una de las columnas que comprende el clculo del
CANAL SEMICIRCULAR

N DESCRIPCIN
[1] Tramo de Colector
[2] rea propia
[3] rea acumulada
[4] Coeficiente de escorrenta
[5] Intensidad de la lluvia
[6] Material
[7] Caudal
[8] Pendiente colector
[9] Tirante medio
[10] Dimetro
[11] Angulo entre el espejo de agua y el centro de la
tubera
[12] rea mojada
[13] Permetro mojado
[14] Radio hidrulico
[15] Velocidad media
[16] Esfuerzo cortante medio
CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil



CLCULO RED DE DESAGES


















[17] Espejo de agua
[18] Numero de froude
CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil





EVALAVULACION PARAMETROS HIDRAULICOS CANAL SEMICIRCULAR EN CONCRETO
Rugosidad absoluta PVC 1,50E-06 m
Rugosidad absoluta CONCRETO ENCOFRADO METALICO 2,50E-04 m
Viscocidad cinematica agua a 20 C 1,02E-06 m/s
Q So Yn DIAMETRO A P R V T T NF
PROPIA ACUM. m/s
m/m m m rad
m
m m m/s
N/m
m
[2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] [13] [14] [15] [16] [17] [18]
0,012 0,01 0,32 150,00 CONCRETO 0,002 0,030 0,019 0,2600 1,10 0,002 0,143 0,012 0,90 3,65 0 , 1 4
2,513
[1]
CANAL SM 2
TRAMO AREA
MATERIAL C I
CARLOS ANDRES MENDOZA RINCON
Ingeniero Civil



6. CONCLUSIONES Y RECOMENDACIONES


Los aparatos sanitarios funcionaran principalmente con la energa generada en el equipo
de presin, garantizando las presiones recomendadas para cada aparato

El tanque de almacenamiento deber ser lavado y desinfectado peridicamente, de
acuerdo a disposiciones de la norma NTC 4576 para el lavado y Desinfeccin qumica de
Tanques para abastecimiento de Agua Potable

La presin en el punto de conexin de las redes hidrulicas existentes debe ser mayor o
igual a 21 mca.

El equipo hidroneumtico debe operar con un caudal superior a 30 GPM, con un rango de
presin entre 30-50 PSI, con dos equipos de bombeo con una potencia de 1 hp.

Una vez terminada una seccin o un sistema de agua fra, debe ser probada su
hermeticidad bajo una presin de agua no menor a los 145 PSI. La tubera debe soportar
la presin durante un periodo de cuatro horas y sostenerla con una tolerancia del 2%. El
agua que se usa para los ensayos debe ser obtenida de una fuente de agua potable y se
deben conservar registros para estos ensayos.

Es necesario realizar una verificacin de niveles de los puntos de entrega de aguas
negras y agua lluvias proyectados antes de replantear las edificaciones.

También podría gustarte