INTRODUCCION
Operaciones
INDICE
Descripcin de comandos de RBS
Pg. 01
Pg. 02
Pg. 05
Cambio de BSIC
Pg. 06
Pg. 07
Pg. 08
Reset de TS y CF
Pg. 09
Pg. 10
Cambio de IDB
Pg. 11
Pg. 12
Pg. 13
Pg. 14
Pg. 15
Pg. 16
Pg. 17
Pg. 18
Pg. 19
Pg. 20
Pg. 21
Pg. 23
Pg. 27
Pg. 28
Pg. 29
CACLP;
ALLIP:ACL=XX;
ALLIP:ACL=ALL;
RXASP:MOTY=RXOTG;
RXMLP:MO=RXOTG-OTG;
RXMSP:MOTY=RXOTG;
RXMOP:MOTY=RXOTG;
RXMOP:MO=RXOTG-OTG;
RXMSP:MO=RXOTG-OTG,SUBORD;
RXMSP:MO=RXOTRX-OTG-Ra,SUBORD;
RXMSP:MO=RXOTS-OTG-Ra-TS&&-TS;
RXTCP:MO=RXOTG-OTG;
RXTCP:MOTY=RXOTG,CELL=NAMEFS;
RXMOP:MOTY=RXOTG;
RXMOP:MO=RXOTF-OTG;
Para Cambiar el valor de compensacin: primero bloquear y descargar OTG y luego aplicar
RXMOC:MO=RXOTF-OTG, TFMODE=S, TFCOMPNEG=4742;
RXMOP:MO=RXOCF-OTG,
RXMOC:MO=RXOCF-OTG,TEI=62;
RXMOP:MO=RXOTG-OTG;
RXMOP:MO=RXOTRX-OTG-Ra;
RXMOP:MO=RXOTX-OTG-Ra&-Ra;
RXMOP:MO=RXODP-OTG-0;
RXCDP:MO=RXOTG-OTG;
RXMDP:MOTY=RXOTS,DEV=RBLT2-#;
RXMFP:MO=RXOCF-OTG;
RLACP:CELL=NAMEFS;
RLAPP:CELL=NAMEFS;
RLBCP:CELL=NAMEFS;
DECLARAR BPCs EN CHGRs
RLBDP:CELL=NAMEFS;
RLBDC:CELL=NAMEFS,NUMREQBPC=X,CHGR=Y;
(Crear)
RLCFP:CELL=NAMEFS;
RLCHP:CELL=NAMEFS;
RLCPP:CELL=NAMEFS;
RLCRP:CELL=NAMEFS;
RLCXP:CELL=NAMEFS;
RLDEP:CELL=NAMEFS;
RLDGI:CELL=NAMEFS,CHGR=X
RLDMP:CELL=NAMEFS;
(Visualizarlos: SPDCH)
(Crear)
RLIHP:CELL=NAMEFS;
RLLCP:CELL=NAMEFS;
RLLOP:CELL=NAMEFS;
(Estado del Radio Control Cell y SCHO para Handover del SDCCH)
RLLUP:CELL=NAMEFS;
Layer 1 a RBS que se desea cargar mas trfico; las otras RBS siguen en Layer 2
RLLHC:CELL=NAMEFS,LAYER=1,LAYERTHR=90;
RLLHP:CELL=NAMEFS;
RLMFP:CELL=NAMEFS;
RLPCP:CELL=NAMEFS;
RLPBP:CELL=NAMEFS;
RLSTC:CELL=NAMEFS,STATE=HALTED;
(Bloquear sector de RBS)
RLSTC:CELL=NAMEFS,STATE=ACTIVE;
(Desbloquear sector de RBS)
RLSTC:CELL=NAMEFS,CHGR=X,STATE=ACTIVE; (Asociar CHGR a sector, X=No CHGR)
RLSTP:CELL=NAMEFS;
(Verifica que CHGR estn en servicio)
RLSSP:CELL=NAMEFS;
(Activacin del DTXU = 1 por sector)
PARA VER DISTURBIOS EN EL E1
DTQUP:DIP=XXRBL2;
(Si valores de N- y F- cambian hay problemas en enlace)
PARA RESETEAR ALARMAS DE DISTURBIOS EN E1S.
DTQSR:DIP=ALL,UNACC,DEGR;
DTQSR:DIP=ALL,SES,ES;
DTQSR:DIP=ALL,SF,DF;
Este comando reajusta cualquier dato de la supervisin de la calidad que se haya recogido
para las trayectorias digitales especificadas y cesa cualquier alarma iniciados.
DTSTP:DIP=XXRBL2
RXMLP:MO=RXOTG-OTG;
RLSTC:CELL=CU20241,STATE=HALTED;
RLDEC:CELL=CU20241,BSIC=30;
RLSTC:CELL=CU20241,STATE=ACTIVE;
Verificar que los CHGR del 1er. Sector estn activos (realizar el comando sector x sector)
RLSTP:CELL=CU20241;
NOTAS
Repetir cada uno de los pasos para los sectores 2 y 3
Si se desea para un solo CHGR de cualquier sector enviar:
RLSTC:CELL=CU20241,CHGR=2,STATE=HALTED;
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
10
CARGAR/DESBLOQUEAR RADIOS
RXESI:MO=RXOTRX-42-1,SUBORD;
; (Punto y coma para confirmacin de comando)
RXBLE:MO=RXOTRX-42-1,SUBORD;
; (Punto y coma para confirmacin de comando)...Esperar y enviar el siguiente.
CTRL + D (para ver el estado de lo ejecutado)
11
PROCEDIMIETO DE RESET DE TS
BLOQUEAR/DESCARGAR TS DE RADIO
RXBLI:MO=RXOTS-42-1-3,FORCE;
; (Punto y coma para confirmacin de comando)
RXESE:MO=RXOTS-42-1-3;
; (Punto y coma para confirmacin de comando)
CARGAR/DESBLOQUEAR TS DE RADIO
RXESI:MO=RXOTS-42-1-3;
; (Punto y coma para confirmacin de comando)
RXBLE:MO=RXOTS-42-1-3;
; (Punto y coma para confirmacin de comando)
CTRL + D (para ver el estado de lo ejecutado)
PROCEDIMIENTO DE RESET DE CF
BLOQUEAR/DESCARGAR EL CF
RXBLI:MO=RXOCF-42,FORCE;
; (Punto y coma para confirmacin de comando)
RXESE:MO=RXOCF-42;
; (Punto y coma para confirmacin de comando)
CARGAR/DESBLOQUEAR EL CF
RXESI:MO=RXOCF-42;
; (Punto y coma para confirmacin de comando)
RXBLE:MO=RXOCF-42;
; (Punto y coma para confirmacin de comando)
CTRL + D (para ver el estado de lo ejecutado)
12
9.
10.
Verificar trfico:
RLCRP:CELL= CU20251;
RLCRP:CELL= CU20252;
RLCRP:CELL= CU20253;
CAMBIAR PCM
1.
2.
3.
13
2.
3.
4.
5.
6.
7.
8.
9.
10.
Poner en modo local la DXU (el led local/remoto debe estar encendido)
11.
Ir a Configuracin....Install IDB.....SI
12.
Una vez cargada la nueva IDB revisar Cabinet 0 y dar conformidad a nueva
configuracin.
13.
Nota:
Si por error no se suben los breakers de los elementos crecidos y estos aparecen medios
borrosos en Cabinet 0; se pueden redefinir de la siguiente manera:
1.- Ir a configuracin.
2.- Define.
3.- Present Rus (pasar a activar los no declarados)
4.- Ok.
Volver a revisar presencia de elementos en Cabinet 0
14
15
16
17
18
19
1656
SPV
1
2
3
Ver que en los TCH tipo FR los valores de LVA son los mismos que los NCH (# de canales
disponibles), y siempre debemos configurar nuestra supervisin de tal manera que el LVA < NCH, ya
que en algn momento el TCH se puede convertir en SDCCH y de producirse ello cuando el sistema
compara estos valores y verifica que el # de NCH es menor que el LVA genera la alarma.
NOTA:
RLSLE:CELL= NAMEFS;
RLSLI:CELL= NAMEFS;
20
21
1.
2.
3.
4.
5.
6.
24
SECTION
2. Desbloquear al DIP
DTBLE:DIP=35RBL2;
NOT ACCEPTED
FAULT CODE 121
CORRESPONDING SDIP LAYER MANUALLY BLOCKED
SNT
ETM2-0
SNT
ETM2-1
SNT
ETM2-1
SNTV SNTP
DIP
1 MUX3-32-2
1 MUX3-32-3
SNTV
1
DEV
RHDEV-0&&-31
RHDEV-32&&-63
1 MUX3-36-6
1 MUX3-36-7
RHDEV-1088&&-1119
RHDEV-1120&&-1151
SNTP
XM-0-0-2
DEV
RALT2-0&&-31
RALT2-32&&-63
DIP
0RAL2
1RAL2
.
35RAL2
.
61RAL2
SNTINL
0
1
RALT2-1120&&-1151 35
RALT2-1952&&-1983 61
XM-0-0-13
EQLEV PROT SDIP SUBSNT DEFPST SNTP
MODE
1
0ETM2 0
XM-0-0-2 2048
1
XM-0-0-13 0
SNTV SNTP
DIP
1 XM-0-1-2 0RBL2
1RBL2
35RBL2
62RBL2
XM-0-1-13
EQLEV PROT SDIP
1
1ETM2
DEV
SNTINL
RBLT2-0&&-31
0
RBLT2-32&&-63
1
RBLT2-1120&&-1151 35
RBLT2-1984&&-2015 62
SUBSNT DEFPST SNTP
MODE
0
XM-0-1-2
2048
1
XM-0-1-13 0
LP
VC12-0
VC12-1
VC12-2
VC12-35
VC12-62
K
1
2
3
3
3
L
1
1
1
5
7
M
1
1
1
2
3
DIP
0RBL2
1RBL2
2RBL2
35RBL2
62RBL2
SDIP SDIPOWNER
1ETM2 SDIPM2
END
25
TPSTP:SDIP=1ETM2;
SYNCHRONOUS DIGITAL PATH STATE
SDIP
LAYER K L M STATE BLS FAULT TYPE PL/TTI
1ETM2
WO
MS-0
WO
MS-1
WO
VC4-0
WO
VC12-ALL
WO
SDIP LAYER LST
ERDIINFO
1ETM2 MS-0
MS-1 STANDBY
END
7. Desbloquear al DIP
DTBLE:DIP=35RBL2;
ORDERED
TEI
0
1
2
3
4
5
6
7
8
9
10
11
DCP1
178
187
196
205
214
223
232
241
250
259
268
277
DCP2
179&&186
188&&195
197&&204
206&&213
215&&222
224&&231
233&&240
242&&249
251&&258
260&&267
269&&276
278&&285
2.
CELL
RXOTRX-10-0
CHGR
AR00641 ALL
TEI
0
SIG
DCP1
CONC
128
SWVERREPL
SWVERDLD
SWVERACT
DEFAULT
B4401R008E
B4401R008E
DCP2
129
130
MO
CELL
RXOTRX-10-1
CHGR
AR00641 ALL
TEI
1
SIG
DCP1
CONC
131
SWVERREPL
SWVERDLD
SWVERACT
DEFAULT
B4401R008E
B4401R008E
DCP2
132
133
MO
CELL
RXOTRX-10-2
CHGR
AR00641 ALL
SWVERREPL
DEFAULT
TEI
2
SWVERDLD
B4401R008E
SIG
CONC
SWVERACT
B4401R008E
DCP1
134
DCP2
135
136
27
MO
CELL
RXOTRX-10-3
CHGR
AR00641 ALL
SWVERREPL
DEFAULT
TEI
3
SIG
DCP1
CONC
137
SWVERDLD
SWVERACT
DCP2
B4401R008E
B4401R008E
138
139
MO
CELL
RXOTRX-10-4
CHGR
AR00642 ALL
TEI
4
SIG
DCP1
CONC
140
SWVERREPL
SWVERDLD
SWVERACT
DEFAULT
B4401R008E
B4401R008E
DCP2
141
142
MO
CELL
RXOTRX-10-5
CHGR
AR00642 ALL
SWVERREPL
DEFAULT
TEI
5
SIG
DCP1
CONC
143
SWVERDLD
SWVERACT
DCP2
B4401R008E
B4401R008E
144
145
MO
CELL
RXOTRX-10-8
CHGR
AR00643 ALL
SWVERREPL
DEFAULT
TEI
8
SIG
DCP1
CONC
166
SWVERDLD
SWVERACT
DCP2
B4401R008E
B4401R008E
167
168
MO
CELL
RXOTRX-10-9
CHGR
AR00643 ALL
TEI
9
SIG
DCP1
CONC
169
SWVERREPL
SWVERDLD
SWVERACT
DEFAULT
B4401R008E
B4401R008E
DCP2
170
171
END
3.
RXAPE:MO=RXOTG-10,DCP=3&4&12;
RXAPI:MO=RXOTG-10,DCP=3&4&12,DEV=RBLT2-483&&-484&-492,RES64K;
EXDAI:DEV=RBLT2-483&&-484&-492;
BLODE:DEV=RBLT2-483&&-484&-492;
RLBDC:CELL=AR00641, CHGR=0, NUMREQBPC=8 ,NUMREQEGPRSBPC=1, TN7BCCH=GPRS;
RLBDC:CELL=AR00642, CHGR=0, NUMREQBPC=8, NUMREQEGPRSBPC=1, TN7BCCH=GPRS;
RLBDC:CELL=AR00643, CHGR=0, NUMREQBPC=8, NUMREQEGPRSBPC=1, TN7BCCH=GPRS;
RLCDC:CELL=AR00641,MC=ON;
RLCDC:CELL=AR00642,MC=ON;
RLCDC:CELL=AR00643,MC=ON;
RXBLI:MO=RXOTRX-10-1,SUBORD,FORCE;
RXESE:MO=RXOTRX-10-1,SUBORD;
RXMOE:MO=RXOTRX-10-1;
28
2.
CELL
CHGR
AR00652 ALL
SWVERREPL
DEFAULT
TEI
0
SIG
DCP1
CONC
SWVERDLD
B4401R008E
128
SWVERACT
B4401R008E
DCP2
129
130
MO
RXOTRX-121-1
CELL
CHGR
AR00653 ALL
TEI
1
SIG
DCP1
CONC
SWVERREPL
SWVERDLD
DEFAULT
B4401R008E
131
SWVERACT
B4401R008E
DCP2
132
29
133
MO
RXOTRX-121-8
CELL
CHGR
AR00651 ALL
SWVERREPL
DEFAULT
TEI
8
SIG
DCP1
CONC
SWVERDLD
B4401R008E
166
SWVERACT
B4401R008E
DCP2
167
168
MO
RXOTRX-121-9
CELL
CHGR
TEI
AR00651 ALL
SWVERREPL
DEFAULT
SIG
DCP1
CONC
SWVERDLD
B4401R008E
169
SWVERACT
B4401R008E
DCP2
170
171
3.
30
RXESI:MO=RXOTRX-121-1,SUBORD;
RXBLE:MO=RXOTRX-121-1,SUBORD;
2.
Infinite time-out
0.1 hours
0.2 hours
0.3 hours
.
25.5 hours
Incluir esta configuracin en la revisin de nuevas RBSs; Para revisar a todas las RBSs se
puede realizar con:
RLSBP:CELL=ALL;
Para cambiar dicho parmetro en forma masificada:
RLSBC:CELL=ALL,T3212=40;
Cabe destacar que stos cambios se pueden realizar en caliente sin necesidad de bloquear a
la celda.
31
RXBLI:MO=RXORX-85-0,FORCE;
RXESE:MO=RXORX-85-0;
RXMOC:MO=RXORX-85-0, RXD=A; (Deja TRX=0 con solo diversidad A)
RXESI:MO=RXORX-85-0;
RXBLE:MO=RXORX-85-0;
RXMOP:MO=RXORX-85-0;
RXMOP:MO=RXORX-85-1;
RXBLI:MO=RXORX-85-1,FORCE;
RXESE:MO=RXORX-85-1;
RXMOC:MO=RXORX-85-1, RXD=A; (Deja TRX=1 con solo diversidad A)
RXESI:MO=RXORX-85-1;
RXBLE:MO=RXORX-85-1;
RXMOP:MO=RXORX-85-1;
Notas
Si se desea se pueden hacer con cada una de las TRX de los sectores.
RXD = A
RXD = B
RXD = AB
32
33
RXMOP:MO=RXOTG-13;
RADIO X-CEIVER ADMINISTRATION
MANAGED OBJECT DATA
MO
RXOTG-13
RSITE
LAMPA_PROV
SWVERREPL
B4401R008E
SWVERDLD
B4401R008E
SWVERACT
BSSWANTED
110
END
34
RXESE:MO=RXOTG-x,SUBORD;
RXMOC:MO=RXOTG-x,RSITE=new name;
RXESI:MO=RXOTG-x,SUBORD;
RXBLE:MO=RXOTG-x,SUBORD;
35
NO INCLUIR
Hola Herman,
Hemos estado revisando las alarmas que se produjeron entre las 18hrs y 19hrs solamente y en
el se observa que los E1 correspondientes a la RBS Juliaca (DIP 10RBL2 para 1900 y 9RBL2
para 850 ) tenan pequeos cortes o micro cortes, te adjunto un archivo (Juliaca_070417a.log)
con las alarmas solamente de la RBS Juliaca, estos micro cortes producen que la RBS tenga
problemas con el sincronismo y con el dispositivo RXOCON (provocando congestin en la cola
LAPD) y luego provoca la cada de la RBS slave.
Te adjunto el log de alarmas de la RBS Juliaca solamente y otro que es el log de alarmas
general donde puedes ver los que corresponde a Zarumilla tambin.
con el comando RXMLP, se puede ver los momentos que quedan registrados cuando tiene
problemas el RXOCON, provocado por la caida del E1.
En este se observa que la ultima vez que hubo problemas fue esta madrugada a las 1.06hrs
DATE TIME MO
070418 010623 RXOCON-10
070418 010623 RXOCON-10
070418 010622 RXOCON-10
070418 010620 RXOCON-10
.
FUNCID EV USERDATA
CONHAND 05 010C FFFF FFFF FFFF FFFF FFFF
CONHAND 05 010C FFFF FFFF FFFF FFFF FFFF
CONHAND 05 010C FFFF FFFF FFFF FFFF FFFF
CONHAND 05 010C FFFF FFFF FFFF FFFF FFFF
36