Está en la página 1de 8

DISEO DE UNA VIGA PARED DE UN SOLO TRAMO

MATERIALES:
20

c=

1.5

fcd=

1.33 KN/cm2

420 S

s=

1.15

fyd=

36.52 KN/cm2

Hormigon: H
Acero:
GEOMETRIA
(superior)

Qd=

238 KN/m

espesor =

(mayorado)

0.15 (m)

h (m) =
3.5
cm"

(inferior)

Qi=

5 KN/m

luz de calculo:
rel h/l =

0.686

(mayorado)

lo (m) =

5.1

lt (m) =

5.5

5.5 (m)

Mou =

918.844 KNm

(referencia)

SI ES VIGA PARED

Vou =

668.25 KN

(referencia)

VERIFICACION ESPESOR MINIMO


LIMITACION POR CORTE

bo (cm) =

7.16

PANDEO LATERAL

bo (cm) =

11.66

Cumple ancho Minimo

CALCULO TENSION DE CORTE CONVENCIONAL


ou=

1272.85714 KN/m2

CALCULO DEL BRAZO DE LALANCA


Z (cm) =

250.0

ARMADURA PRINCIPAL
As =

10.064 cm2

En 0,15h o 0,15l sobre la cara inferior de la viga

ARMADURA VERTICAL
v

0.0026139

tv =

20 cm

Av/tv =

0.0392

Av=

0.7842 cm2

Av=

1.3690 cm2/ml

Av=

0.2738

Av=

1.0580 cm2

ARMADURA VERTICAL por carga inferior


para

20 cm

ARMADURA VERTICAL total


para 2fi8

0.57 Sv (cm)=

tv (cm)=

20

11

cm2
ARMADURAS SECUNDARIAS HORIZONTALES
Vous =
Voui =
Ah/Sh =

654.5 KN

Vu=

13.75 KN

ou=

0.0406 para 2fi8

0.6683 MN

0.00270912

1.2729 Mpa
0.57 Sh (cm)=

cm2

14 armadura que se dispondra en el rango de 0,15h a 0,45 h

ARMADURAS SECUNDARIAS HORIZONTALES SUPERIORES


h

0.002

para 2 fi 8

1 Sh` (cm)=
cm2

23 distribuida en una altura de 0,45h desde la c

en el rango de 0,15h a 0,45 h (cambiar h por l en caso de h>l)

una altura de 0,45h desde la cara superior de la viga

DISEO DE UNA VIGA PARED DE DOS TRAMOs


MATERIALES:
20

c=

1.5

fcd=

1.33 KN/cm2

420 S

s=

1.15

fyd=

36.52 KN/cm2

Hormigon: H
Acero:
GEOMETRIA

(superior)

espesor =

Qd=

238

0.15 (m)

h (m) =
2.75
cm"

(inferior)

Qi=

5 KN/m

(mayorado)

lo (m) =

4.1

lt (m) =

4.5

(inferior)

CALCULO DE LOS MOMENTOS CON SOBRECARGA MODERADA SEGN BAEL 80


Qd =

5.62

Gd =

19.07
0.22762252

Tramo1

Vou =

(derecha)

Mou =

668.25 KN
918.84375 KNm

Mw =
Mt =
verificacion

Tramo 2

Vou =

546.75

(izquierda)

Mou =

615.09375

551.30625 KNm

Me =

369.05625

705.935484 KNm

Mt =

472.568382

705.935484

>

689.132813 verificacion

472.568382

CUMPLE
rel h/l =

0.611

>
CUMPLE

SI ES VIGA PARED

VERIFICACION ESPESOR MINIMO


LIMITACION POR CORTE

bo (cm) =

9.11

PANDEO LATERAL

bo (cm) =

12.63

luz de calculo tramo1:

5.5 (m)

luz de calculo tramo2:

4.5 (m)

Cumple ancho Minimo

CALCULO TENSION DE CORTE CONVENCIONAL


tramo1

ou=

1620

KN/m2

ou=

tramo2

1325.45455 KN/m2

CALCULO DEL BRAZO DE LALANCA


tramo1

Z (cm) =

192.5 tramo2

Z (cm) =

ARMADURA PRINCIPAL
tramo1
Mw =
Mt =
tramo2

551.30625 KNm

As =

7.84 cm2

705.935484 KNm

As =

10.04 cm2

172.5

Me =

369.05625 KNm

As =

5.86 cm2

Mt =

472.568382 KNm

As =

7.50 cm2

ARMADURA VERTICAL
tramo1

0.00332679

tv =

20 cm

Av/tv =

0.0499

Av=

0.9980 cm2

Av=

1.3690 cm2/ml

Av=

0.2738

Av=

1.2718 cm2

ARMADURA VERTICAL por carga inferior


tramo1
para

20 cm

ARMADURA VERTICAL total


para 2fi8

1 Sv (cm)=

tv (cm)=

16

cm2
ARMADURAS SECUNDARIAS HORIZONTALES

Tramo 1
Vous =

654.5 KN

Vu=

0.6683 MN

Voui =

13.75 KN

ou=

1.6200 Mpa

Ah/Sh =

0.0604 para 2fi8

1 Sh (cm)=

0.00402541

17

cm2
ARMADURAS SECUNDARIAS HORIZONTALES SUPERIORES
h

0.00241525

para 2 fi 8

1 Sh` (cm)=
cm2

28

20

KN/m

(mayorado)

espesor =

0.15 (m)

Qi=

KN
KNm
KNm
KNm
461.320313
CUMPLE

5 KN/m

(mayorado)

lo (m) =

5.1

lt (m) =

5.5

tramo2

0.00272192

tv =

20 cm

Av=

20

tramo2
para

Av/tv =

0.0408

Av=

0.8166 cm2

Av=

1.3690 cm2/ml

Av=

0.2738

Av=

1.0904 cm2

ARMADURA VERTICAL total


para 2fi8

1 Sv (cm)=

tv (cm)=

18

Tramo
Vous =

535.5 KN

Vu=

0.5468 MN

Voui =

11.25 KN

ou=

1.3255 Mpa

Ah/Sh =

0.0434 para 2fi8

0.002

1 Sh (cm)=

para 2 fi 8

0.00289265

23

1 Sh` (cm)=
cm2

38

20