ESPECIFICACIONES TECNICAS

A B C D
CONCRETO SIMPLE:
SOLADOS : F'c = 1:12 CEMENTO:HORMIGON
CIMIENTO CORRIDOS : F'c = 1:10 CEMENTO:HORMIGON + 30% P. G. (MAX. Ø 6")
SOBRECIMIENTOS : F'c = 140 kg/cm2 + 25% P.M. (MAX. Ø 3")
C-02 Ø1/2"@ 0.15m Ø1/2"@ 0.15m

Ø1/2"@ 0.20m
Ø1/2"@ 0.15m FALSO PISO : F'c = 1:8 CEMENTO:HORMIGON

Ø1/2"@ 0.15m
CAPACIDAD PORTANTE DEL SUELO:
ESFUERZO DEL TERRENO : 0.90 kg/cm2
TIPO DE SUELO : ARENA POBREMENTE GRADUADA (SP)

Ø1/2"@ 0.15m
C-02
C-02
8 8

Ø1/2"@ 0.15m
CONCRETO ARMADO:
CC-04

Ø1/2"@ 0.20m

Ø1/2"@ 0.20m
C-07 Ø1/2"@ 0.20m
C-06
Ø1/2"@ 0.15m CC-06 C-10 CC-04 C-09 PL-02 ACERO : fy = 4200 kg/cm2 Acero Corrugado Grado 60
SOBRECIMIENTO ARMADO : F'c = 175 kg/cm2
Ø1/2"@ 0.15m

Ø1/2"@ 0.20m Ø1/2"@ 0.20m COLUMNAS : F'c = 210 kg/cm2


NFC -1.30
Z-01 Z-01 NFC -1.30
Z-01 Z-03 VIGAS : F'c = 210 kg/cm2
C-06 Ø1/2"@ 0.15m LOSA ALIGERADA : F'c = 210 kg/cm2

7 V-C 7 ZAPATA : F'c = 210 kg/cm2

Ø1/2"@ 0.15m
C-a CC-02 C-08 COLUMNA Y VIGA
(de amarre)
: F'c = 175 kg/cm2

NFC -1.90 VIGA DE CIMENTACION : F'c = 210 kg/cm2

Z-06

CC-05
Z-02 Z-02 NOTA: UTILIZAR COMO TAMAÑO MAXIMO PIEDRA DE 1/2"

NFC -1.90 RECUBRIMIENTOS:


N.P.T +0.15
Z-07

CC-02
COLUMNAS Y VIGAS : 2.50 cm.

V-C
Ø1/2"@ 0.15m LOSA ALIGERADA : 2.50 cm.
CC-01
V-C

CAP. 1200 L Ø1/2"@ 0.15m


TANQUE CISTERNA ZAPATAS : 7.50 cm.

N.P.T +0.45
ALBAÑILERIA CONFINADA:
NFC -1.60 C-a LADRILLO CLASE IV SOLIDO, HERCULES I : F'm = 65 kg/cm2
: 9 cm x 14 cm x 24 cm.

Ø1/2"@ 0.15m
DIMENSION DE LADRILLO
RESISTENCIA MINIMA DEL LADRILLO : F'b = 130 kg/cm2

Ø1/2"@ 0.15m % MAXIMO DE VACIOS : 30% DEL VOLUMEN TOTAL


ZC-01
Ø1/2"@ 0.15m

Ø1/2"@ 0.15m
MORTERO P1 (CEMENTO/ARENA) : 1:5 (CEMENTO - ARENA)
PL-04 C-01 ESPESOR DE JUNTA ENTRE HILADAS : 1. cm. Min., 1.5 Max.
Z-03 PL-04 LA ALBAÑILERIA IRA UNIDA A LA ESTRUCTURA CON ACERO DE ANCLAJE

Ø1/2"@ 0.15m
C-02 PL-04 C-03 2 Ø 1/4" CADA 03 HILADAS LOS CUALES ENTRAN 0.50 m. EN EL MURO Y
C-a
Ø1/2"@ 0.15m

ANCLAN EN LOS ELEMENTOS DE CONCRETO UN MINIMO DE 0.25 m

6 Ø1/2"@ 0.15m CC-02


V-C
Ø1/2"@ 0.15m CC-02 CC-03
V-C
Ø1/2"@ 0.15m
6 PL-03 Ø1/2"@ 0.15m
CURADO:
ZAPATAS : 5 DIAS MINIMO
NFC -1.90
NFC -1.90 NFC -1.60 ELEMENTOS DE CONCRETO ARMADO : 7 DIAS MINIMO

Z-04 FONDO DE VIGAS Y LOSAS : 14 DIAS MINIMO

CC-01

Ø1/2"@ 0.15m
CC-03

C-08
CC-01

CC-08
CC-08

CC-08

CC-08

V-C

Ø1/2"@ 0.15m
V-C

V-C

N.P.T +0.30 NOTAS GENERALES:


N.P.T +0.45
N.P.T +0.45
- Vaciar columnas amarradas a los muros en forma dentada
- Evitar empalmes y traslapes en zonas de máximo esfuerzo
- Curar concreto por vía humeda

C-02 CC-02 CC-03


Ø1/2"@ 0.15m
C-03 CC-02 CC-03 PL-04 Z-05
Ø1/2"@ 0.15m

CUADRO DE EMPALMES:
5 V-C 5 Z-04 Longitudes mínimas en centímetros de anclajes de barras en
C-a tracción (L.t.) de barras de compresion (L.c.) y de traslapes
Ø1/2"@ 0.15m
PL-04 de barras en tracción (L.e.).

Ø1/2"@ 0.15m
Ø1/2"@ 0.15m

NFC -1.90

Z-03
ZC-01
Z-06
Z-08
Z-04 Ø1/2"@ 0.15m
CC-01
V-C

N.P.T +0.45 NFC -1.90 NFC -1.90


N.P.T +0.45
PARÁMETROS DE DISEÑO SISMORESISTENTES
CC-01
Ø1/2"@ 0.15m Factor de Zona : Z = 0.45 (Tacna)
V-C
Uso e Importancia : U = 1.0 (Edificaciones Comunes)
CC-02

1.67
V-C

Factor Amplificación Sísmica : C = 2.5 máximo (Variable)


Terreno : Arena Pobremente Graduada (GP)

Ø1/2"@ 0.15m
Hf: 2.00m , Capacidad Admisible 0.90kg/cm2,

Z-08 Z-07
Factor de Terreno : S = 1.10
Tp = 0.6 seg. TI = 2.0 seg.
Ø1/2"@ 0.15m Gravedad : G = 9.8 m/seg.

PL-03 PL-02 FACTOR DE SISTEMA ESTRUCTURAL


Ø1/2"@ 0.15m

PL-04
Ø1/2"@ 0.15m

4 V-C V-C 4 Ø1/2"@ 0.15m C-02 Ø1/2"@ 0.15m Rdxx : 8 Porticado


Ø1/2"@ 0.15m

Rdyy : 7 Sistema Dual


PL-01 CC-03 Ø1/2"@ 0.15m
CC-03

Ø1/2"@ 0.15m
NFC -1.90

Ø1/2"@ 0.15m
M-02 C-02

Ø1/2"@ 0.15m
Ø1/2"@ 0.15m
Ø1/2"@ 0.15m
C-a NFC -1.90 NFC -1.90

C-03
CC-03

Z-02 C-01
CC-01
V-C

V-C

N.P.T +0.45

ZC-02 C-02
CC-09

Ø1/2"@ 0.15m
C-02
C-01
ZC-01 ZC-02 ZC-03
Ø1/2"@ 0.15m

Ø1/2"@ 0.15m

3 Z-05 CC-03
V-C
M-02
3
C-a Ø1/2"@ 0.15m C-02
NFC -1.60 NFC -1.60

N.P.T +0.45 DETALLE DE ZAPATAS


CC-09

V-C

ESCALA:1/25
CC-01

N.P.T +0.45
CC-02

V-C
V-C

N.P.T - 0.95
CC-03

C-a

Z-05
ZC-03 Ø1/2"@ 0.15m
Longitud de Gancho
12 Ø RESUMEN DE LAS CONDICIONES DE CIMENTACION
Ø1/2"@ 0.15m
Ø1/2"@ 0.15m
CC-09

C-01 C-02
2 2
V-C
2
V-C 2 DE ACUERDO AL INFORME DEL ESTUDIO DE SUELOS DESARROLLADO EN LA ZONA
1
CC-02
1
C-01
CC-08

Ø1/2"@ 0.15m
Escalera
NFC -1.90 NFC -1.90 TIPO DE CIMENTACION: ZAPATAS CONECTADAS CON VIGAS DE CIMENTACION
CC-07 C-a ESTRATO DE APOYO A LA CIMENTACION : ARENA POBREMENTE GRADUADO (SP)
C-a PROFUNDIDAD DE LA CIMENTACION : 2.00 m. (PROFUNDIDAD MINIMA)
CC-07
CC-04

C-05 CLASIFICACION DEL SUELO : TIPO S3 (SUELOS BLANDOS)


CC-07

N.P.T +0.45
N.P.T +0.15
Ø PRESION ADMISIBLE : 0.90 Kg/cm2
N.P.T +0.45
2 1 D
RECOMENDACIONES:
CC-08 C-04 CC-08 C-a CC-05 CC-05 M-01
1 C-a CC-04 C-04 C-a 1 Ver Detalle de DETALLE DE 1.- No cimentar sobre turbas, suelo orgánico, tierra vegetal, desmonte, relleno sanitario o relleno
artificial. Estos materiales inadecuados deberán ser removidos en su totalidad antes de cons-
Doblado DOBLADO truir la edificacion y ser reemplazados con material adecuado debidamente compactado.

2.- En caso de que la profundidad indicada se encuentra material suelto o relleno, profundizar la
excavación por lo menos 30 cm., en terreno natural y realizar una sub-zapata.
DIAMETRO Ø1/4" Ø3/8" Ø1/2" Ø5/8" Ø3/4"
3.- En donde se requiera rellenar para conformar el falso piso se deberá usar afirmado compacta-
D 4 6 8 10 12 do al 95% del proctor modificado. La compactación deberá ser con plancha vibradora en capas
D = En cms. no más de 20 cm.

4.- El estudio de sales muestra que se producirá un ataque al acero y concreto, por lo que se
A B C D recomienda usar aditivos especiales, pudiendo usarse cemento tipo HS Antisalitre para
concreto en cimentaciones.

DOBLADO DE REFUERZO LONGITUDINAL


CIMENTACIONES: PRIMERA PLANTA ESCALA:S/E
VIVIENDA UNIFAMILIAR 1 : 50