Está en la página 1de 1

D C B A

DIAGRAMA DE STRINGS MESA 6 (STRING 21, 22, 23, 24 Y 25) - ALARGUE STRING 21 HASTA INVERSOR 2.
ESCALA 1:75 -ALARGUE STRING 22, 23, 24 Y 25 HASTA INVERSOR 3.

NOMENCLATURA DE IDENTIFICACIÓN
2.21.1 2.21.2 2.21.3 2.21.4 2.21.5 2.21.6 2.21.7 2.21.8 2.21.9 2.21.10 2.21.11 2.21.12 2.21.13 2.21.14 2.21.15 2.21.16 DE MODULOS.
N° DE MÓDULO
N° DE STRING
N° DE INVERSOR
3.22.1 3.22.2 3.22.3 3.22.4 3.22.5 3.22.6 3.22.7 3.22.8 3.22.9 3.22.10 3.22.11 3.22.12 3.22.13 3.22.14 3.22.15 3.22.16 3.25.9 3.25.10 3.25.11 3.25.12 3.25.13 3.25.14 3.25.15 3.25.16

3.23.1 3.23.2 3.23.3 3.23.4 3.23.5 3.23.6 3.23.7 3.23.8 3.23.9 3.23.10 3.23.11 3.23.12 3.23.13 3.23.14 3.23.15 3.23.16

X.Y.Z

3.24.1 3.24.2 3.24.3 3.24.4 3.24.5 3.24.6 3.24.7 3.24.8 3.24.9 3.24.10 3.24.11 3.24.12 3.24.13 3.24.14 3.24.15 3.24.16 3.25.8 3.25.7 3.25.6 3.25.5 3.25.4 3.25.3 3.25.2 3.25.1

DIAGRAMA DE STRINGS MESA 7 (STRING 26, 27 Y 28) ALARGUE STRING 26, 27 Y 28 HASTA INVERSOR 3. TABLA DE DISTRIBUCIÓN DE STRINGS
ESCALA 1:75 ALARGUE (-) ALARGUE (+)
STRING CANT. MOD. MESA CONDUCTOR
(m) (m)
3.26.18 String 21

IN
51 51

V.
16 CABLE ZZ-F 4mm2

2
3.26.1 3.26.2 3.26.3 3.26.4 3.26.5 3.26.6 3.26.7 3.26.8 3.26.9 3.26.10 3.26.11 3.26.12 3.26.13 3.26.14 3.26.15 3.26.16 3.26.17
String 22 16 CABLE ZZ-F 4mm2 34 34
String 23 16 MESA 6 CABLE ZZ-F 4mm2 52 52
String 24 16 CABLE ZZ-F 4mm2 35 35
3.28.9 3.28.10 3.28.11 3.28.12 3.28.13 3.28.14 3.28.15 3.28.16 String 25 16 CABLE ZZ-F 4mm2 24 24
String 26 18 CABLE ZZ-F 4mm2 47 46
3.27.1 3.27.2 3.27.3 3.27.4 3.27.5 3.27.6 3.27.7 3.27.8 3.27.9 3.27.10 3.27.11 3.27.12 3.27.13 3.27.14 3.27.15 3.27.16 String 27 16 MESA 7 CABLE ZZ-F 4mm2 49 48

INVERSOR 3
(110 KW)
String 28 16 CABLE ZZ-F 4mm2 37 36
String 29 16 CABLE ZZ-F 4mm2 61 60
2 2
3.28.8 3.28.7 3.28.6 3.28.5 3.28.4 3.28.3 3.28.2 3.28.1 String 30 16 MESA 8 CABLE ZZ-F 4mm2 50 49
String 31 16 CABLE ZZ-F 4mm2 59 58
String 32 16 CABLE ZZ-F 4mm2 72 71
String 33 16 MESA 9 CABLE ZZ-F 4mm2 60 59
String 34 16 CABLE ZZ-F 4mm2 60 59
DIAGRAMA DE STRINGS MESA 8 (STRING 29, 30 Y 31) ALARGUE STRING 29, 30 Y 31 HASTA INVERSOR 3.
ESCALA 1:75 String 35 14 MESA 2 CABLE ZZ-F 10mm2 125 160

3.29.1 3.29.2 3.29.3 3.29.4 3.29.5 3.29.6 3.29.7 3.29.8 3.29.9 3.29.10 3.29.11 3.29.12 3.29.13 3.29.14 3.29.15
3.29.16

DISTRIBUCIÓN GENERAL DE STRINGS


3.31.9 3.31.10 3.31.11 3.31.12 3.31.13 3.31.14 3.31.15 3.31.16 ESCALA S/E

1
3.30.1 3.30.2 3.30.3 3.30.4 3.30.5 3.30.6 3.30.7 3.30.8 3.30.9 3.30.10 3.30.11 3.30.12 3.30.13 3.30.14 3.30.15 3.30.16

SA

2
LA DISTRIBUCIÓN DE STRINGS DE LAS MESAS

SA
ME
6, 7,8,9 Y 10 SE MUESTRAN EN LA LAMINA

ME
22-06-VCS-DE-STR-06-2

3.31.8 3.31.7 3.31.6 3.31.5 3.31.4 3.31.3 3.31.2 3.31.1

DIAGRAMA DE STRINGS MESA 9 (STRING 32, 33 Y 34)


ESCALA 1:75 ALARGUE STRING 32, 33 Y 34 HASTA INVERSOR 3.

3
SA

4
SA
ME

5
ME
3.32.1 3.32.2 3.32.3 3.32.4 3.32.5 3.32.6 3.32.7 3.32.8 3.32.9 3.32.10 3.32.11 3.32.12 3.32.13 3.32.14 3.32.15

SA
3.32.16

ME
MES
A 6

MES
A 7
3.34.9 3.34.10 3.34.11 3.34.12 3.34.13 3.34.14 3.34.15 3.34.16 MES
A8
3.33.1 3.33.2 3.33.3 3.33.4 3.33.5 3.33.6 3.33.7 3.33.8 3.33.9 3.33.10 3.33.11 3.33.12 3.33.13 3.33.14 3.33.15 3.33.16 MES
A9

3.34.8 3.34.7 3.34.6 3.34.5 3.34.4 3.34.3 3.34.2 3.34.1

1 1

NOTAS:
1. LAS DIMENSIONES INDICADAS EN LA LÁMINA SE ENCUENTRAN EN MILÍMETROS.
2. LOS MATERIALES QUE REQUIEREN CERTIFICACIÓN PARA SU USO CUMPLEN CON LO ESTABLECIDO POR LA SEC.
3. LOS CONDUCTORES QUE PASAN POR DEBAJO DE LOS MÓDULOS DEBEN SER CANALIZADOS POR EL PERFIL DE LA ESTRUCTURA DE SOPORTE, SEPARADOS POR POLARIDAD Y
DEBIDAMENTE SUJETOS CON AMARRAS PLÁSTICAS CON FILTRO UV. LISTADO DE LÁMINAS CROQUIS DE UBICACIÓN: TIMBRE DE INSCRIPCIÓN:
4. EL CABLE SOLAR DEBE QUEDAR PROTEGIDO POR LOS RAYOS UV Y NO SOMETERSE A ESFUERZOS MECÁNICOS . N° CÓDIGO DESCRIPCIÓN
5. LOS MÓDULOS SE DEBEN GIRAR 180° UNO CON RESPECTO AL OTRO EN CADA MESA PARA REALIZAR EL CONEXIONADO COCIDO. 1 22-06-VCS-DE-LAY-01-2 LAYOUT GENERAL Rising SunCHILE
6. LA LONG DE ALARGUE INDICADA EN TABLA DE DISTRIBUCIÓN DE STRINGS ES REFERENCIAL, EL CORTE DE CADA CONDUCTOR DEBE SER TAL QUE GARANTICE LA CONEXIÓN 2 22-06-VCS-DE-DUA-02-2 DIAGRAMA UNILINEAL CORRIENTE ALTERNA N PROYECTO: COMERCIAL FOTOVOLTAICO
ENTRE EL PANEL Y EL INVERSOR (PRESENTAR EL CABLE PREVIO AL CORTE) 3 22-06-VCS-DE-DUC-03-2 DIAGRAMA UNILINEAL CORRIENTE CONTINUA VIÑA CASA SILVA
7. AL INTERIOR DE LAS CAJAS METÁLICAS SE DEBE GARANTIZAR HOLGURA EN EL CONDUCTOR PARA EVITAR ESFUERZOS MECÁNICOS DEBIDO A LA TENSIÓN. 4 22-06-VCS-DE-CDG-04-2 CUADROS DE GENERACIÓN
UBICACIÓN: DESCRIPCIÓN:
5 22-06-VCS-DE-CAN-05-2 CANALIZACIÓN Y CABLEADO - 1 DIAGRAMA DE STRINGS - 2
6 22-06-VCS-DE-CAN-06-2 CANALIZACIÓN Y CABLEADO - 2 LÁMINA: CÓD. LAM:
HIJUELA S/N, COMUNA SAN FERNANDO,
7 22-06-VCS-DE-STR-07-2 DIAGRAMA DE STRINGS -1 08 DE 13 22-06-VCS-DE-STR-08-2
SEXTA REGIÓN REVISÓ: ABROBÓ: FECHA:
8 22-06-VCS-DE-STR-08-2 DIAGRAMA DE STRINGS -2 06/2022
M. PAREDES L. SANTIAGO
9 22-06-VCS-DE-EDM-09-2 ESTRUCTURA DE MONTAJE INSTALADOR:
ACEPTACIÓN DEL PROPIETARIO:
10 22-06-VCS-DE-SEG-10-2 SEGURIDAD FECHA:
11 22-06-VCS-DE-PAT-11-2 PUESTA A TIERRA NOMBRE:
12 22-06-VCS-DE-CTR-12-2 CONTROL Y MONITOREO MARIO PABLO SILVA SILVA MATÍAS PAREDES / ING. ELÉCTRICO
COORDENADAS UTM: DATUM (WGS84):
13 22-06-VCS-DE-DEQ-13-2 DISPOSICIÓN DE EQUIPOS H19 319587 mE; 6176213.4mS 10.748.040-4 19.191.699-9 / LICENCIA CLASE A
D C B A

También podría gustarte