Está en la página 1de 60

S.A. DE C.V.

ESTUDIO DE
PERÍMETROS DE
RUIDO DE
FUENTE FIJA PLANTA
IBERDROLA ENERGIA
MONTERREY, S.A. DE C.V
NOM-081-SEMARNAT-1994
PLANTA COGENERACION
MONTERREY

N° R: T474/23
O.T: TAM078/23
EL PRESENTE INFORME SOLO AFECTA A LOS OBJETOS SOMETIDOS A PRUEBA
EL PRESENTE REPORTE NO DEBERÁ REPRODUCIRSE PARCIALMENTE SIN LA APROBACIÓN POR ESCRITO DE LA EMPRESA
Acred. ema N° FF-0142-021/11 vigente a partir del 2011-11-18 y AL-0137-012/11 vigente a partir del 2011-12-15 Aprob. PROFEPA N° PFPA-APR-LP-RUIDO-009/2022
Aprob. STPS N° LPSTPS-039/2021

Calle 7 N° 233 Fraccionamiento El Caracol, Col. Enrique Cárdenas González, C.P. 89309 Tampico, Tamaulipas
Tels: 01 (833) 2 56 21 77 / 2 10 94 85 / 2 10 65 06 email: gerenciageneral@asesotam.com.mx
S.A. DE C.V.

Tampico, Tamps., a 08 de Septiembre de 2023.

IBERDROLA ENERGIA MONTERREY, S.A. DE C.V.


PLANTA COGENERACION MONTERREY
Gral. Miguel Barragán Pte. #702
Col. Industrial
Monterrey, Nuevo León
C.P. 64440
Tel: 81 8375 3375

At’n.- Ing. Jesús Alejandro Urbina Arriaga

Nos permitimos informarle los resultados del estudio de Emisión de Ruido de Fuente Fija
realizado los días 11 y 12 de Agosto de 2023 en cuatro zonas consideradas críticas, previamente
solicitadas por Iberdrola Energía Monterrey, S.A. de C.V. Planta Cogeneración Monterrey y
definidas conforme al recorrido preliminar realizado por Asesoría Ambiental, S.A. de C.V., con el
fin de determinar su cumplimiento con la norma NOM-081-SEMARNAT-1994, que establece los
límites máximos permisibles de emisión de ruido de las fuentes fijas y su método de medición.
Los valores de las emisiones de ruido de las cuatro zonas consideradas críticas se presentan a
continuación:
Diurno Nocturno
Ubicación Nivel de Emisión de Nivel de Emisión de
Fuente Fija Fuente Fija
Zona Crítica 1 (ZC1): al Sur colindando
con Avenida Jesús Flores Alba
No emite nivel sonoro No emite nivel sonoro
Zona Crítica 2 (ZC2): al Oeste colindando
con Avenida Amado Nervo
No emite nivel sonoro No emite nivel sonoro
Zona Crítica 3 (ZC3): al Norte colindando
con Avenida Miguel Barragán
No emite nivel sonoro No emite nivel sonoro
Zona Crítica 4 (ZC4): al Este colindando
con empresa Biopapel
No emite nivel sonoro No emite nivel sonoro

El resultado obtenido para las zonas críticas es de acuerdo al punto 5.3.3.4.4 de la citada NOM-
081-SEMARNAT-1994 “Si ∆50<0.75 dB, la fuente fija no emite nivel sonoro”, debido a que en
la ZC1 turno diurno el ∆50= -3.406 dB y para turno nocturno el ∆50= -3.058 dB, ZC2 turno
diurno el ∆50= -3.691 dB y para turno nocturno el ∆50= -11.682 dB, ZC3 turno diurno el
∆50= -1.116 dB y para turno nocturno el ∆50= -0.867 dB y ZC4 turno diurno el ∆50= -2.694
dB y para turno nocturno el ∆50= -1.884 dB. No obstante, señalamos que de acuerdo al
numeral 5.4 de la modificación de 2013 de la NOM-081-SEMARNAT-1994 Tabla 1, el límite
máximo permisible en horario de 06:00 a 22:00 es 68 dB y en horario de 22:00 a 06:00 es de 65
dB para zonas industriales y comerciales.

N° R: T474/23
O.T: TAM078/23
EL PRESENTE INFORME SOLO AFECTA A LOS OBJETOS SOMETIDOS A PRUEBA hoja
EL PRESENTE REPORTE NO DEBERÁ REPRODUCIRSE PARCIALMENTE SIN LA APROBACIÓN POR ESCRITO DE LA EMPRESA
Acred. ema N° FF-0142-021/11 vigente a partir del 2011-11-18 y AL-0137-012/11 vigente a partir del 2011-12-15 Aprob. PROFEPA N° PFPA-APR-LP-RUIDO-009/2022
1 de 12
Aprob. STPS N° LPSTPS-039/2021
Calle 7 N° 233 Fraccionamiento El Caracol, Col. Enrique Cárdenas González, C.P. 89309 Tampico, Tamaulipas
Tels: 01 (833) 2 56 21 77 / 2 10 94 85 / 2 10 65 06 email: gerenciageneral@asesotam.com.mx
S.A. DE C.V.

Cabe mencionar que nuestra empresa se encuentra debidamente acreditada ante la Entidad
Mexicana de Acreditación, A.C. (EMA) con la renovación N° FF-0142-021/11 para evaluar
fuentes fijas a partir del 18 de noviembre de 2011 y con la N° AL-0137-012/11 para evaluar
ambiente laboral a partir del 15 de diciembre de 2011; con la aprobación de la Procuraduría
Federal de Protección al Medio Ambiente N° PFPA-APR-LP-RUIDO-009/2022 y ante la
Secretaria del Trabajo y Previsión Social con la aprobación N° LPSTPS-039/2021. VER ANEXO
6 (9 hojas).
Sin más por el momento, quedamos a sus órdenes para cualquier aclaración o comentario.

“Solidez Profesional al Servicio de la Industria”

Atentamente

Ing. Juan Ricardo Jiménez Morales


Signatario Autorizado

N° R: T474/23
O.T: TAM078/23
EL PRESENTE INFORME SOLO AFECTA A LOS OBJETOS SOMETIDOS A PRUEBA hoja
EL PRESENTE REPORTE NO DEBERÁ REPRODUCIRSE PARCIALMENTE SIN LA APROBACIÓN POR ESCRITO DE LA EMPRESA
Acred. ema N° FF-0142-021/11 vigente a partir del 2011-11-18 y AL-0137-012/11 vigente a partir del 2011-12-15 Aprob. PROFEPA N° PFPA-APR-LP-RUIDO-009/2022
2 de 12
Aprob. STPS N° LPSTPS-039/2021
Calle 7 N° 233 Fraccionamiento El Caracol, Col. Enrique Cárdenas González, C.P. 89309 Tampico, Tamaulipas
Tels: 01 (833) 2 56 21 77 / 2 10 94 85 / 2 10 65 06 email: gerenciageneral@asesotam.com.mx
S.A. DE C.V.

C O N T E N I D O

1. INTRODUCCION .......................................................................................................... 4

2. OBJETIVO .................................................................................................................... 4

3. METODOLOGIA ........................................................................................................... 4

4. RESULTADOS DE LA EVALUACION Y/O MEMORÍA DE CÁLCULO ....................... 8

5. INSTRUMENTACION ................................................................................................. 12

6. REFERENCIAS........................................................................................................... 12

7. CONCLUSIONES ....................................................................................................... 12

N° R: T474/23
O.T: TAM078/23
EL PRESENTE INFORME SOLO AFECTA A LOS OBJETOS SOMETIDOS A PRUEBA hoja
EL PRESENTE REPORTE NO DEBERÁ REPRODUCIRSE PARCIALMENTE SIN LA APROBACIÓN POR ESCRITO DE LA EMPRESA
Acred. ema N° FF-0142-021/11 vigente a partir del 2011-11-18 y AL-0137-012/11 vigente a partir del 2011-12-15 Aprob. PROFEPA N° PFPA-APR-LP-RUIDO-009/2022
3 de 12
Aprob. STPS N° LPSTPS-039/2021
Calle 7 N° 233 Fraccionamiento El Caracol, Col. Enrique Cárdenas González, C.P. 89309 Tampico, Tamaulipas
Tels: 01 (833) 2 56 21 77 / 2 10 94 85 / 2 10 65 06 email: gerenciageneral@asesotam.com.mx
S.A. DE C.V.

1. INTRODUCCION

En la normatividad vigente se considera el hecho de que la emisión de ruido proveniente de las


fuentes fijas altera el bienestar del ser humano y el daño que le produce, con motivo de la
exposición, depende de la magnitud y del número, por unidad de tiempo, de los desplazamientos
temporales del umbral de audición. Por lo cual la autoridad especifica límites máximos
permisibles de emisión de este contaminante y su forma de evaluación. Lo anterior queda
asentado en la NOM-081-SEMARNAT-1994 Que establece los límites máximos permisibles de
emisión de ruido de las fuentes fijas y su método de medición.

2. OBJETIVO

Determinar el nivel de ruido en cuatro zonas consideradas críticas en las colindancias de mayor
impacto. Lo anterior a solicitud de la empresa Iberdrola Energía Monterrey, S.A. de C.V. (Planta
Cogeneración Monterrey) con la finalidad de verificar el cumplimiento con el límite máximo
permisible de la norma NOM-081-SEMARNAT-1994.

3. METODOLOGIA

Siguiendo lo establecido en la citada norma NOM-081-SEMARNAT-1994, se describen las


actividades del reconocimiento inicial y el desarrollo de la evaluación.

3.1 IDENTIFICACIÓN DE LA FUENTE FIJA

3.1.1 Datos Generales de la Fuente Fija

Empresa: Iberdrola Energía Monterrey, S.A. de C.V.


(Planta Cogeneración Monterrey)
Responsable de la Empresa: Ing. Jesús Alejandro Urbina Arriaga

3.1.2 Ubicación de la Fuente Fija y Colindancias. VER ANEXO 1 (1 hoja)

La empresa se encuentra ubicada en Gral. Miguel Barragán Pte. #702, Colonia Industrial,
Monterrey, Nuevo León, C.P. 64440.

La empresa colinda al Norte con Avenida Miguel Barragán, al Sur con Avenida Jesús
Flores Alba, al Este con empresa Biopapel y al Oeste con Avenida Amado Nervo.

N° R: T474/23
O.T: TAM078/23
EL PRESENTE INFORME SOLO AFECTA A LOS OBJETOS SOMETIDOS A PRUEBA hoja
EL PRESENTE REPORTE NO DEBERÁ REPRODUCIRSE PARCIALMENTE SIN LA APROBACIÓN POR ESCRITO DE LA EMPRESA
Acred. ema N° FF-0142-021/11 vigente a partir del 2011-11-18 y AL-0137-012/11 vigente a partir del 2011-12-15 Aprob. PROFEPA N° PFPA-APR-LP-RUIDO-009/2022
4 de 12
Aprob. STPS N° LPSTPS-039/2021
Calle 7 N° 233 Fraccionamiento El Caracol, Col. Enrique Cárdenas González, C.P. 89309 Tampico, Tamaulipas
Tels: 01 (833) 2 56 21 77 / 2 10 94 85 / 2 10 65 06 email: gerenciageneral@asesotam.com.mx
S.A. DE C.V.

3.1.3 Características de operación de la Fuente Fija

Horario de operación: 24 horas


Horario de emisión máxima: 24 horas
Eventualidad de fuentes Ninguna
móviles:

3.1.4 Situación de la fuente fija en el predio y Ubicación de la Zona Crítica

De acuerdo a como se establece en la norma NOM-081-SEMARNAT-1994, se


realiza un recorrido por el perímetro de la planta obteniendo los siguientes
resultados (ANEXO 2, 2 hojas):

LADO Diurno Nocturno


dB(A) dB(A)
Norte 60.2 – 65.8 58.5 – 66.5
Sur 58.6 – 63.5 60.5 – 63.8
Este 60.1 – 65.8 61.9 – 65.8
Oeste 59.8 – 62.8 51.9 – 55.3

La zona crítica 1 se ubica al sur con Avenida Jesús Flores Alba.


La zona crítica 2 se ubica al oeste con Avenida Amado Nerro.
La zona crítica 3 se ubica al norte con Avenida Miguel Barragán.
La zona crítica 4 se ubica al este con Empresa Biopapel.

Observaciones: Se consideran esas distancias por presentar mayores niveles de


ruido.
Se realizan 4 zonas críticas a solicitud del cliente por tener población colindante en
los perímetros.

Ver hojas de campo. ANEXO 5 (10 hojas)

N° R: T474/23
O.T: TAM078/23
EL PRESENTE INFORME SOLO AFECTA A LOS OBJETOS SOMETIDOS A PRUEBA hoja
EL PRESENTE REPORTE NO DEBERÁ REPRODUCIRSE PARCIALMENTE SIN LA APROBACIÓN POR ESCRITO DE LA EMPRESA
Acred. ema N° FF-0142-021/11 vigente a partir del 2011-11-18 y AL-0137-012/11 vigente a partir del 2011-12-15 Aprob. PROFEPA N° PFPA-APR-LP-RUIDO-009/2022
5 de 12
Aprob. STPS N° LPSTPS-039/2021
Calle 7 N° 233 Fraccionamiento El Caracol, Col. Enrique Cárdenas González, C.P. 89309 Tampico, Tamaulipas
Tels: 01 (833) 2 56 21 77 / 2 10 94 85 / 2 10 65 06 email: gerenciageneral@asesotam.com.mx
S.A. DE C.V.

3.1.5 Descripción de fuentes emisoras de ruido hacia la zona crítica

MAQUINARIA O MARCA CAPACIDAD HORARIO DE HORARIO DE


EQUIPO OPERACIÓN EMISION
MAXIMA

Caldera 101 N.D. 197.64 GJ/h 24 horas 24 horas

Caldera 102 N.D. 197.64 GJ/h 24 horas 24 horas

Compresores N.D. N.D. 24 horas 24 horas

N.D.: No Disponible

3.2 CARACTERÍSTICAS DEL ESTUDIO

3.2.1 Datos generales del Estudio

Fecha: 11 y 12 de Agosto de 2023


Ruido : Fuente
Turno: Diurno Nocturno
Zona critica 1
Hora inicial: 14:55 23:20
Hora final: 15:45 00:11
Zona critica 2
Hora inicial: 15:56 00:25
Hora final: 16:50 01:10
Zona critica 3
Hora inicial: 17:05 01:22
Hora final: 17:47 02:13
Zona critica 4
Hora inicial: 17:58 02:20
Hora final: 18:50 03:15
Ruido Fondo
Hora inicial: 19:05 03:20
Hora final: 19:50 03:58
Evaluador: Tec. Francisco Bautista

N° R: T474/23
O.T: TAM078/23
EL PRESENTE INFORME SOLO AFECTA A LOS OBJETOS SOMETIDOS A PRUEBA hoja
EL PRESENTE REPORTE NO DEBERÁ REPRODUCIRSE PARCIALMENTE SIN LA APROBACIÓN POR ESCRITO DE LA EMPRESA
Acred. ema N° FF-0142-021/11 vigente a partir del 2011-11-18 y AL-0137-012/11 vigente a partir del 2011-12-15 Aprob. PROFEPA N° PFPA-APR-LP-RUIDO-009/2022
6 de 12
Aprob. STPS N° LPSTPS-039/2021
Calle 7 N° 233 Fraccionamiento El Caracol, Col. Enrique Cárdenas González, C.P. 89309 Tampico, Tamaulipas
Tels: 01 (833) 2 56 21 77 / 2 10 94 85 / 2 10 65 06 email: gerenciageneral@asesotam.com.mx
S.A. DE C.V.

3.2.2 Localización aproximada de los puntos de medición, VER ANEXO 3 (1 hoja)

Se localizaron los puntos como se establece en los puntos 5.3.1.2.1., 5.3.2.5.1., y


5.3.2.6.1.1., de la ya citada norma NOM-081-SEMARNAT-1994, quedando como se
muestran en el plano anexo a este informe.

La distancia entre puntos de fuente es la siguiente:


ZC1: A-B.-14.5 m | B-C.-8.6 m | C-D.-8.4 m | D-E.-7.5 m
ZC2: A-B.-11.0 m | B-C.-10.5 m | C-D.-9.6 m | D-E.-12.5 m
ZC3: A-B.-5.5 m | B-C.-4.5 m | C-D.-5.3 m | D-E.-4.2 m
ZC4: A-B.-7.5 m | B-C.-8.3 m | C-D.-5.5 m | D-E.-5.7 m

3.2.3 Tipo de Medición

Semicontinua

3.2.4 Otras Eventualidades Descriptivas

Turno: Diurno Nocturno


Temperatura ambiente: 38 °C 29 °C
Presión Atmosférica: 101 450 Pa
Viento: Moderado
Obstáculos: Ninguno

N° R: T474/23
O.T: TAM078/23
EL PRESENTE INFORME SOLO AFECTA A LOS OBJETOS SOMETIDOS A PRUEBA hoja
EL PRESENTE REPORTE NO DEBERÁ REPRODUCIRSE PARCIALMENTE SIN LA APROBACIÓN POR ESCRITO DE LA EMPRESA
Acred. ema N° FF-0142-021/11 vigente a partir del 2011-11-18 y AL-0137-012/11 vigente a partir del 2011-12-15 Aprob. PROFEPA N° PFPA-APR-LP-RUIDO-009/2022
7 de 12
Aprob. STPS N° LPSTPS-039/2021
Calle 7 N° 233 Fraccionamiento El Caracol, Col. Enrique Cárdenas González, C.P. 89309 Tampico, Tamaulipas
Tels: 01 (833) 2 56 21 77 / 2 10 94 85 / 2 10 65 06 email: gerenciageneral@asesotam.com.mx
S.A. DE C.V.

4. RESULTADOS DE LA EVALUACION Y/O MEMORÍA DE CÁLCULO

4.1 RESULTADOS

Parámetro Resultado dB(A)


ZC1 ZC2
Diurno Nocturno Diurno Nocturno
Neq 61.957 62.755 61.609 54.228
N50 fuente fija 61.794 62.692 61.509 54.067
N10 62.102 62.917 61.753 54.371
N50 fondo 65.200 65.749 65.200 65.749
Desviación Estándar (σ) 0.241 0.176 0.190 0.237
∆50: Diferencia (N50 Fuente)-
-3.406* -3.058* -3.691* -11.682*
(N50 Fondo)
Corrección por ruido de fondo
-.-.- -.-.- -.-.- -.-.-
(Cf)
N'50 62.011 62.850 61.681 54.281
Corrección por presencia de
valores extremos (Ce) 0.217072161 0.158815299 0.171628982 0.21416398
Nivel de Fuente Fija (Nff) 62.011 62.850 61.681 54.281
Corrección del nivel de Fuente
Fija por ruido de fondo (N’)ff 62.011 62.850 61.681 54.281
Nivel Emisión de Fuente Fija:
*De acuerdo al punto 5.3.3.4.4 No emite No emite No emite No emite
de la citada NOM-081-
nivel nivel nivel nivel
SEMARNAT-1994 “Si ∆50<0.75
dB, la fuente fija no emite nivel sonoro sonoro sonoro sonoro
sonoro”.

N° R: T474/23
O.T: TAM078/23
EL PRESENTE INFORME SOLO AFECTA A LOS OBJETOS SOMETIDOS A PRUEBA hoja
EL PRESENTE REPORTE NO DEBERÁ REPRODUCIRSE PARCIALMENTE SIN LA APROBACIÓN POR ESCRITO DE LA EMPRESA
Acred. ema N° FF-0142-021/11 vigente a partir del 2011-11-18 y AL-0137-012/11 vigente a partir del 2011-12-15 Aprob. PROFEPA N° PFPA-APR-LP-RUIDO-009/2022
8 de 12
Aprob. STPS N° LPSTPS-039/2021
Calle 7 N° 233 Fraccionamiento El Caracol, Col. Enrique Cárdenas González, C.P. 89309 Tampico, Tamaulipas
Tels: 01 (833) 2 56 21 77 / 2 10 94 85 / 2 10 65 06 email: gerenciageneral@asesotam.com.mx
S.A. DE C.V.

Parámetro Resultado dB(A)


ZC3 ZC4
Diurno Nocturno Diurno Nocturno
Neq 64.253 65.009 62.863 63.981
N50 fuente fija 64.084 64.882 62.506 63.866
N10 64.333 65.158 62.753 64.131
N50 fondo 65.200 65.749 65.200 65.749
Desviación Estándar (σ) 0.194 0.215 0.192 0.207
∆50: Diferencia (N50 Fuente)-
-1.116* -0.867* -2.694* -1.884*
(N50 Fondo)
Corrección por ruido de fondo
-.-.- -.-.- -.-.- -.-.-
(Cf)
N'50 64.259 65.077 62.680 64.053
Corrección por presencia de
valores extremos (Ce) 0.175318706 0.194223817 0.173692129 0.18709844
Nivel de Fuente Fija (Nff) 64.259 65.077 62.863 64.053
Corrección del nivel de Fuente
Fija por ruido de fondo (N’)ff 64.259 65.077 62.863 64.053
Nivel Emisión de Fuente Fija:
*De acuerdo al punto 5.3.3.4.4 No emite No emite No emite No emite
de la citada NOM-081-
nivel nivel nivel nivel
SEMARNAT-1994 “Si ∆50<0.75
dB, la fuente fija no emite nivel sonoro sonoro sonoro sonoro
sonoro”.
INCERTIDUMBRE EXPANDIDA UE CALCULADA DE ACUERDO A LA NORMA NMX-CH-140-IMNC-2002, CON UN FACTOR DE COBERTURA DE
k= 2 Y UN NIVEL DE CONFIANZA DEL 95%
UE de Ruido fuente fija= + 0.1732 dB

4.2 TABLAS DE LECTURAS TOMADAS EN CAMPO. VER ANEXO 4 (10 hojas)

N° R: T474/23
O.T: TAM078/23
EL PRESENTE INFORME SOLO AFECTA A LOS OBJETOS SOMETIDOS A PRUEBA hoja
EL PRESENTE REPORTE NO DEBERÁ REPRODUCIRSE PARCIALMENTE SIN LA APROBACIÓN POR ESCRITO DE LA EMPRESA
Acred. ema N° FF-0142-021/11 vigente a partir del 2011-11-18 y AL-0137-012/11 vigente a partir del 2011-12-15 Aprob. PROFEPA N° PFPA-APR-LP-RUIDO-009/2022
9 de 12
Aprob. STPS N° LPSTPS-039/2021
Calle 7 N° 233 Fraccionamiento El Caracol, Col. Enrique Cárdenas González, C.P. 89309 Tampico, Tamaulipas
Tels: 01 (833) 2 56 21 77 / 2 10 94 85 / 2 10 65 06 email: gerenciageneral@asesotam.com.mx
S.A. DE C.V.

4.3 GLOSARIO

Nivel equivalente (Neq): Es el nivel de energía acústica uniforme y constante que


contiene la misma energía que el ruido producido en forma fluctuante por una fuente fija
durante el período de observación.

Nivel 50 (N50): Es el límite inferior de todos los niveles sonoros presentes durante un
lapso igual al 50% del período de observación. (Percentil 50)

Nivel 10 (N10): Es el límite inferior de todos los niveles sonoros presentes durante un
lapso igual al 10% del período de observación. (Percentil 10).

Desviación Estándar (σ): Es la raíz cuadrada de la varianza de una función estadística.

∆50: Diferencia entre N50 fuente y N50 fondo


Corrección por ruido de fondo (Cf): cuando la diferencia entre N50 fuente y N50 de
fondo es mayor a 0.75 se hace corrección por ruido de fondo

N’50: Corrección de N50 medio por valores extremos

Ce: Corrección por presencia de valores extremos

Nivel de Fuente Fija (Nff): se obtiene al determinar el mayor del Neq y N’50

(N’)ff: Corrección del nivel de Fuente Fija por ruido de fondo

Nivel Emisión de Fuente Fija: Es el resultado de un proceso estadístico que determina


el nivel de ruido emitido por la fuente fija a su entorno.

N° R: T474/23
O.T: TAM078/23
EL PRESENTE INFORME SOLO AFECTA A LOS OBJETOS SOMETIDOS A PRUEBA hoja
EL PRESENTE REPORTE NO DEBERÁ REPRODUCIRSE PARCIALMENTE SIN LA APROBACIÓN POR ESCRITO DE LA EMPRESA
Acred. ema N° FF-0142-021/11 vigente a partir del 2011-11-18 y AL-0137-012/11 vigente a partir del 2011-12-15 Aprob. PROFEPA N° PFPA-APR-LP-RUIDO-009/2022
10 de 12
Aprob. STPS N° LPSTPS-039/2021
Calle 7 N° 233 Fraccionamiento El Caracol, Col. Enrique Cárdenas González, C.P. 89309 Tampico, Tamaulipas
Tels: 01 (833) 2 56 21 77 / 2 10 94 85 / 2 10 65 06 email: gerenciageneral@asesotam.com.mx
S . A4.4
. D E C .MEMORIA
V. DE CÁLCULO

Donde: Neq= Nivel equivalente en cada punto; m= Número total de observaciones; N= Nivel observado

Donde: σ = Desviación estándar de la medición en cada punto


N i = Nivel de observación
N = Número de observaciones por punto de medición

N 50 =
N 50

n
__
Donde: N50 = Promedio de N50

__
Donde: N10 = Promedio de N10

C e
= 0.9023
_
Donde: σ = Promedio de las desviaciones estándar para los puntos de medición de
Fuente fija
Ce= Corrección por presencia de valores extremos

50 = (N 50 ) fuente− (N 50 ) fondo


__ __ __ __
Donde: N50 fuente = N50 de la fuente fija; N50 fondo = N50 del ruido de fondo

C f = −(50 + 9) + 3 450 − 3
Donde: Cf= Corrección por ruido de fondo

N '50 = N50 + Ce
Donde: N’50=N50 corregida por extremos

Nff= Nivel de fuente fija será el valor más alto entre N’50 y Neq

N ' ff = N ff + C f
Donde: N’ff= Nff corregida por ruido de fondo

N° R: T474/23
O.T: TAM078/23
EL PRESENTE INFORME SOLO AFECTA A LOS OBJETOS SOMETIDOS A PRUEBA hoja
EL PRESENTE REPORTE NO DEBERÁ REPRODUCIRSE PARCIALMENTE SIN LA APROBACIÓN POR ESCRITO DE LA EMPRESA
Acred. ema N° FF-0142-021/11 vigente a partir del 2011-11-18 y AL-0137-012/11 vigente a partir del 2011-12-15 Aprob. PROFEPA N° PFPA-APR-LP-RUIDO-009/2022
11 de 12
Aprob. STPS N° LPSTPS-039/2021
Calle 7 N° 233 Fraccionamiento El Caracol, Col. Enrique Cárdenas González, C.P. 89309 Tampico, Tamaulipas
Tels: 01 (833) 2 56 21 77 / 2 10 94 85 / 2 10 65 06 email: gerenciageneral@asesotam.com.mx
S.A. DE C.V. S
R = N d − N eq + 10 log
10
Donde: R = Reducción acústica por elemento constructivo; S =área del elemento constructivo:
Nd = Nivel medido en el interior de la fuente; Neq = Nivel equivalente en la zona
Crítica

(N ')Rff = (N ') ff + 0.5  R


Donde: (N’)ffR = Nivel de emisión de la fuente fija de no existir el elemento constructivo

5. INSTRUMENTACION

En la realización del presente estudio se utilizó un Sonómetro Integrador y un Calibrador acústico


con las siguientes características:

SONOMETRO: AA-LAB-SON-05 CALIBRADOR: AA-LAB-CAL-02


Marca: Svantek Marca: Metrosonics
Modelo: Svan 973 Modelo: QC-10M
Nº Serie: 104833 Nº Serie: PEE020010

Los equipos se encuentran debidamente calibrados para lo cual en el ANEXO 7 (7 hojas) se


presentan los certificados de calibración de los mismos.

6. REFERENCIAS

NOM-081-SEMARNAT-1994 “Que establece los límites máximos permisibles de emisión


de ruido de las fuentes fijas y su método de medición”
ACUERDO por el que se modifica el numeral 5.4 de la Norma Oficial Mexicana NOM-081-
SEMARNAT-1994, Que establece los límites máximos permisibles de emisión de ruido de
las fuentes fijas y su método de medición. 03-dic-2013
PO-016 “Evaluación de Ruido de Fuente Fija”

7. CONCLUSIONES

El estudio se efectuó conforme a lo establecido en la NOM-081-SEMARNAT-1994, y la


conclusión del resultado obtenido para la ZC1, ZC2, ZC3 y ZC4 turno diurno y nocturno es que
no emite nivel sonoro debido a que la diferencia entre el N50 de fuente y de fondo es menor a
0.75, lo anterior conforme al punto 5.3.3.4.4 de la norma de referencia.

‫ ־־־־־־־־־־־־־־־־־־־־‬FIN DEL INFORME ‫־־־־־־־־־־־־־־־־־־־־‬

N° R: T474/23
O.T: TAM078/23
EL PRESENTE INFORME SOLO AFECTA A LOS OBJETOS SOMETIDOS A PRUEBA hoja
EL PRESENTE REPORTE NO DEBERÁ REPRODUCIRSE PARCIALMENTE SIN LA APROBACIÓN POR ESCRITO DE LA EMPRESA
Acred. ema N° FF-0142-021/11 vigente a partir del 2011-11-18 y AL-0137-012/11 vigente a partir del 2011-12-15 Aprob. PROFEPA N° PFPA-APR-LP-RUIDO-009/2022
12 de 12
Aprob. STPS N° LPSTPS-039/2021
Calle 7 N° 233 Fraccionamiento El Caracol, Col. Enrique Cárdenas González, C.P. 89309 Tampico, Tamaulipas
Tels: 01 (833) 2 56 21 77 / 2 10 94 85 / 2 10 65 06 email: gerenciageneral@asesotam.com.mx
S.A. DE C.V.

PLANO DE UBICACIÓN
ANEXO 1 DE LA FUENTE FIJA

EL PRESENTE INFORME SOLO AFECTA A LOS OBJETOS SOMETIDOS A PRUEBA


EL PRESENTE REPORTE NO DEBERÁ REPRODUCIRSE PARCIALMENTE SIN LA APROBACIÓN POR ESCRITO DE LA EMPRESA
Acred. ema N° FF-0142-021/11 vigente a partir del 2011-11-18 y AL-0137-012/11 vigente a partir del 2011-12-15 Aprob. PROFEPA N° PFPA-APR-LP-RUIDO-009/2022
Aprob. STPS N° LPSTPS-039/2021

Calle 7 N° 233 Fraccionamiento El Caracol, Col. Enrique Cárdenas González, C.P. 89309 Tampico, Tamaulipas
Tels: 01 (833) 2 56 21 77 / 2 10 94 85 / 2 10 65 06 email: gerenciageneral@asesotam.com.mx
Calle Miguel Barragán

UBICACIÓN DE LA
FUENTE FIJA

IBERDROLA ENERGIA
MONTERREY, S.A. DE
C.V. PLANTA
COGENERACIÓN
MONTERREY
Calle Amado Nervo

Empresa Biopapel
11 y 12 de Agosto de
2023

Calle Jesús Flores Alba


S.A. DE C.V.
S.A. DE C.V.

CROQUIS DE
ANEXO 2 RECONOCIMIENTO

EL PRESENTE INFORME SOLO AFECTA A LOS OBJETOS SOMETIDOS A PRUEBA


EL PRESENTE REPORTE NO DEBERÁ REPRODUCIRSE PARCIALMENTE SIN LA APROBACIÓN POR ESCRITO DE LA EMPRESA
Acred. ema N° FF-0142-021/11 vigente a partir del 2011-11-18 y AL-0137-012/11 vigente a partir del 2011-12-15 Aprob. PROFEPA N° PFPA-APR-LP-RUIDO-009/2022
Aprob. STPS N° LPSTPS-039/2021

Calle 7 N° 233 Fraccionamiento El Caracol, Col. Enrique Cárdenas González, C.P. 89309 Tampico, Tamaulipas
Tels: 01 (833) 2 56 21 77 / 2 10 94 85 / 2 10 65 06 email: gerenciageneral@asesotam.com.mx
Calle Miguel Barragán

CROQUIS DE
RECONOCIMIENTO
(DIURNO)

IBERDROLA ENERGIA
MONTERREY, S.A. DE
C.V. PLANTA
COGENERACIÓN
MONTERREY

Empresa Biopapel
Calle Amado Nervo

11 y 12 de Agosto de
2023

Simbología

Lecturas de Reconocimiento

Calle Jesús Flores Alba


S.A. DE C.V.
Calle Miguel Barragán

CROQUIS DE
RECONOCIMIENTO
(NOCTURNO)

IBERDROLA ENERGIA
MONTERREY, S.A. DE
C.V. PLANTA
COGENERACIÓN
MONTERREY

Empresa Biopapel
Calle Amado Nervo

11 y 12 de Agosto de
2023

Simbología

Lecturas de Reconocimiento

Calle Jesús Flores Alba


S.A. DE C.V.
S.A. DE C.V.

LOCALIZACIÓN
ANEXO 3 APROXIMADA DE LOS
PUNTOS DE MEDICIÓN

EL PRESENTE INFORME SOLO AFECTA A LOS OBJETOS SOMETIDOS A PRUEBA


EL PRESENTE REPORTE NO DEBERÁ REPRODUCIRSE PARCIALMENTE SIN LA APROBACIÓN POR ESCRITO DE LA EMPRESA
Acred. ema N° FF-0142-021/11 vigente a partir del 2011-11-18 y AL-0137-012/11 vigente a partir del 2011-12-15 Aprob. PROFEPA N° PFPA-APR-LP-RUIDO-009/2022
Aprob. STPS N° LPSTPS-039/2021

Calle 7 N° 233 Fraccionamiento El Caracol, Col. Enrique Cárdenas González, C.P. 89309 Tampico, Tamaulipas
Tels: 01 (833) 2 56 21 77 / 2 10 94 85 / 2 10 65 06 email: gerenciageneral@asesotam.com.mx
III
Calle Miguel Barragán
A B C D E

1 A LOCALIZACIÓN
2 APROXIMADA DE
B LOS PUNTOS DE
MEDICIÓN
E C
IBERDROLA ENERGIA
IV
MONTERREY, S.A. DE
II C.V. PLANTA
D
COGENERACIÓN

Empresa Biopapel
Calle Amado Nervo

D
MONTERREY

E 11 y 12 de Agosto de
2023
C

Simbología:
Zona Critica 1 Zona Critica 2
Zona Critica 3 Zona Critica 4
B A, B, C, D, E = Ruido de Fuente
I, II, III, IV, V = Ruido de Fondo
V
Fuentes generadoras de ruido
1. Caldera 101 y 102
2. Compresores de Gas

E D C B A
Calle Jesús Flores Alba
I S.A. DE C.V.
S.A. DE C.V.

TABLAS DE LECTURAS
ANEXO 4 TOMADAS EN CAMPO

EL PRESENTE INFORME SOLO AFECTA A LOS OBJETOS SOMETIDOS A PRUEBA


EL PRESENTE REPORTE NO DEBERÁ REPRODUCIRSE PARCIALMENTE SIN LA APROBACIÓN POR ESCRITO DE LA EMPRESA
Acred. ema N° FF-0142-021/11 vigente a partir del 2011-11-18 y AL-0137-012/11 vigente a partir del 2011-12-15 Aprob. PROFEPA N° PFPA-APR-LP-RUIDO-009/2022
Aprob. STPS N° LPSTPS-039/2021

Calle 7 N° 233 Fraccionamiento El Caracol, Col. Enrique Cárdenas González, C.P. 89309 Tampico, Tamaulipas
Tels: 01 (833) 2 56 21 77 / 2 10 94 85 / 2 10 65 06 email: gerenciageneral@asesotam.com.mx
S.A. DE C.V.

RUIDO DE FUENTE (Diurno) ZC1


dB
A B C D E
1 63.8 62.3 61.7 59.6 61.3
2 63.5 62.4 61.4 59.4 61.2
3 63.4 62.3 61.2 59.8 61.8
4 63.5 62.6 61.8 59.6 61.5
5 63.5 62.4 61.7 59.4 61.4
6 63.2 62.2 61.4 59.8 61.6
7 63.8 62.2 61.5 59.7 61.8
8 63.4 62.5 61.4 59.7 61.5
9 63.2 62.3 61.8 59.8 61.4
10 63.8 62.4 61.7 59.6 61.8
11 63.7 62.4 61.4 59.4 61.3
12 63.5 62.7 61.5 59.5 61.5
13 63.6 62.6 61.6 59.8 61.4
14 63.4 62.8 61.2 59.4 61.3
15 63.5 62.5 61.8 59.6 61.5
16 63.2 62.4 61.5 59.8 61.4
17 63.6 62.8 61.4 60.2 61.8
18 63.4 62.4 61.8 60.6 61.3
19 63.2 62.6 61.5 60.8 61.6
20 63.5 62.5 61.2 60.5 61.8
21 63.2 62.8 61.8 60.4 61.5
22 63.2 62.4 61.6 60.4 61.4
23 63.4 62.8 61.4 60.5 61.2
24 63.4 62.5 61.6 60.7 61.8
25 63.8 62.8 61.7 60.3 61.5
26 63.6 62.6 61.8 60.8 61.6
27 63.4 62.4 61.4 60.5 61.7
28 63.8 62.8 61.2 60.4 61.8
29 63.5 62.6 61.6 60.7 61.2
30 63.4 62.5 61.7 60.4 61.3
31 63.2 62.4 61.8 60.6 61.6
32 63.5 62.8 61.5 60.5 61.4
33 63.4 62.4 61.4 60.2 61.2
34 63.4 62.5 61.6 59.9 61.8
35 63.5 62.5 61.5 59.7 61.6
36 63.2 62.8 61.4 59.8 61.4
37 63.4 62.4 61.8 59.4 61.4
38 63.4 62.4 61.5 59.6 61.5
39 63.5 62.6 61.5 59.7 61.6
40 63.4 62.4 61.4 59.8 61.8
41 63.5 62.4 61.2 59.6 61.5
42 63.2 62.8 61.7 59.6 61.4
43 63.8 62.7 61.8 59.5 61.2
44 63.5 62.4 61.7 59.8 61.5
45 63.4 62.5 61.7 59.4 61.5
46 63.2 62.8 61.6 59.3 61.4
47 63.6 62.4 61.8 59.6 61.2
48 63.5 62.7 61.9 59.5 61.8
49 63.2 62.8 61.5 59.8 61.7
50 63.4 62.5 61.4 59.7 61.4 PROMEDIO
N50 63.45 62.53 61.56 59.92 61.50 61.794
Desv. Std. (σ) 0.18 0.18 0.19 0.45 0.20 0.241
N10 63.69 62.76 61.81 60.50 61.75 62.102
NEq 63.46 62.54 61.56 59.95 61.51 61.957

Calle 7 N° 233 Fraccionamiento El Caracol, Col. Enrique Cárdenas González, C.P. 89309 Tampico, Tamps.
Tels: 01 (833) 2 56 21 77 / 2 10 94 85 / 2 10 65 06 email: gerenciageneral@asesotam.com.mx
S.A. DE C.V.

RUIDO DE FUENTE (Diurno) ZC2


dB
A B C D E
1 62.4 61.3 60.8 62.4 60.5
2 62.8 61.2 60.2 62.4 60.5
3 62.5 61.8 60.8 62.8 60.8
4 62.3 61.6 60.5 62.5 60.5
5 62.8 61.5 60.7 62.3 60.2
6 62.4 61.4 60.4 62.6 60.8
7 62.6 61.3 60.7 62.5 60.6
8 62.5 61.2 60.8 62.8 60.5
9 62.4 61.8 60.5 62.3 60.4
10 62.5 61.5 60.4 62.5 60.2
11 62.5 61.6 60.2 62.4 60.8
12 62.8 61.5 60.8 62.8 60.4
13 62.4 61.4 60.5 62.5 60.2
14 62.3 61.8 60.3 62.4 60.5
15 62.5 61.5 60.5 62.6 60.4
16 62.4 61.2 60.7 62.5 60.8
17 62.8 61.6 60.8 62.4 60.5
18 62.6 61.8 60.4 62.8 60.2
19 62.5 61.4 60.2 62.5 60.5
20 62.4 61.6 60.3 62.8 60.4
21 62.8 61.5 60.4 62.4 60.2
22 62.3 61.4 60.2 62.7 60.2
23 62.5 61.2 60.8 62.6 60.2
24 62.8 61.6 60.4 62.5 60.8
25 62.5 61.8 60.5 62.5 60.7
26 62.5 61.5 60.8 62.4 60.5
27 62.6 61.4 60.6 62.6 60.2
28 62.4 61.8 60.5 62.4 60.6
29 62.8 61.2 60.8 62.3 60.5
30 62.7 61.5 60.6 62.3 60.4
31 62.4 61.5 60.5 62.3 60.2
32 62.5 61.2 60.4 62.4 60.4
33 62.3 61.8 60.3 62.8 60.6
34 62.4 61.5 60.8 62.5 60.8
35 62.8 61.4 60.6 62.4 60.7
36 62.5 61.2 60.5 62.8 60.4
37 62.6 61.8 60.3 62.5 60.5
38 62.7 61.5 60.5 62.8 60.2
39 62.8 61.3 60.3 62.4 60.2
40 62.6 61.4 60.8 62.6 60.8
41 62.4 61.2 60.6 62.7 60.4
42 62.5 61.5 60.5 62.5 60.6
43 62.3 61.3 60.2 62.8 60.5
44 62.5 61.4 60.4 62.4 60.4
45 62.4 61.8 60.8 62.5 60.2
46 62.8 61.7 60.7 62.8 60.7
47 62.4 61.4 60.5 62.7 60.4
48 62.2 61.5 60.2 62.4 60.2
49 62.9 61.6 60.2 62.5 60.6
50 62.5 61.4 60.6 62.8 60.5 PROMEDIO
N50 62.54 61.49 60.52 62.54 60.47 61.509
Desv. Std. (σ) 0.18 0.20 0.21 0.17 0.20 0.190
N10 62.76 61.74 60.78 62.76 60.73 61.753
NEq 62.54 61.49 60.52 62.55 60.47 61.609

Calle 7 N° 233 Fraccionamiento El Caracol, Col. Enrique Cárdenas González, C.P. 89309 Tampico, Tamps.
Tels: 01 (833) 2 56 21 77 / 2 10 94 85 / 2 10 65 06 email: gerenciageneral@asesotam.com.mx
S.A. DE C.V.

RUIDO DE FUENTE (Diurno) ZC3


dB
A B C D E
1 63.4 65.4 65.3 63.4 62.8
2 63.4 65.3 65.2 63.2 62.5
3 63.2 65.4 65.3 63.5 62.7
4 63.8 65.8 65.2 63.4 62.4
5 63.2 65.5 65.8 63.7 62.5
6 63.5 65.4 65.3 63.4 62.5
7 63.4 65.5 65.7 63.3 62.6
8 63.2 65.4 65.4 63.2 62.3
9 63.5 65.7 65.8 63.5 62.4
10 63.4 65.4 65.3 63.4 62.5
11 63.2 65.5 65.2 63.4 62.8
12 63.5 65.8 65.4 63.6 62.7
13 63.5 65.8 65.3 63.2 62.8
14 63.3 65.7 65.8 63.5 62.2
15 63.8 65.6 65.7 63.4 62.3
16 63.5 65.6 65.4 63.8 62.5
17 63.6 65.8 65.2 63.7 62.8
18 63.5 65.2 65.6 63.7 62.6
19 63.4 65.5 65.3 63.2 62.5
20 63.1 65.4 65.4 63.5 62.5
21 63.2 65.3 65.5 63.6 62.8
22 63.2 65.2 65.6 63.7 62.3
23 63.4 65.4 65.7 63.4 62.4
24 63.4 65.8 65.4 63.6 62.2
25 63.5 65.3 65.3 63.4 62.8
26 63.4 65.4 65.4 63.2 62.5
27 63.8 65.4 65.4 63.8 62.7
28 63.5 65.7 65.7 63.5 62.6
29 63.2 65.4 65.8 63.7 62.6
30 63.8 65.4 65.3 63.5 62.5
31 63.4 65.3 65.4 63.4 62.4
32 63.5 65.7 65.6 63.5 62.8
33 63.4 65.8 65.5 63.3 62.4
34 63.3 65.4 65.4 63.4 62.2
35 63.8 65.3 65.3 63.2 62.5
36 63.5 65.2 65.6 63.4 62.2
37 63.7 65.3 65.8 63.8 62.4
38 63.8 65.8 65.3 63.5 62.8
39 63.7 65.4 65.7 63.2 62.5
40 63.6 65.8 65.4 63.4 62.3
41 63.2 65.7 65.5 63.8 62.4
42 63.5 65.7 65.2 63.2 62.8
43 63.4 65.8 65.1 63.4 62.5
44 63.8 65.4 65.2 63.5 62.7
45 63.7 65.5 65.2 63.2 62.8
46 63.5 65.3 65.8 63.5 62.5
47 63.4 65.7 65.4 63.4 62.4
48 63.2 65.7 65.7 63.2 62.5
49 63.5 65.4 65.8 63.5 62.4
50 63.4 65.3 65.6 63.4 62.8 PROMEDIO
N50 63.46 65.51 65.46 63.45 62.53 64.084
Desv. Std. (σ) 0.20 0.20 0.21 0.18 0.19 0.194
N10 63.71 65.76 65.73 63.68 62.77 64.333
NEq 63.47 65.51 65.47 63.46 62.54 64.253

Calle 7 N° 233 Fraccionamiento El Caracol, Col. Enrique Cárdenas González, C.P. 89309 Tampico, Tamps.
Tels: 01 (833) 2 56 21 77 / 2 10 94 85 / 2 10 65 06 email: gerenciageneral@asesotam.com.mx
S.A. DE C.V.

RUIDO DE FUENTE (Diurno) ZC4


dB
A B C D E
1 65.3 62.8 60.8 61.8 62.3
2 65.5 62.5 60.5 61.5 62.8
3 65.4 62.4 60.4 61.4 62.4
4 65.3 62.3 60.8 61.3 62.4
5 65.3 62.5 60.3 61.4 62.5
6 65.8 62.4 60.5 61.3 62.4
7 65.3 62.2 60.7 61.3 62.4
8 65.7 62.8 60.4 61.8 62.8
9 65.4 62.5 60.8 61.5 62.5
10 65.5 62.6 60.5 61.4 62.3
11 65.3 62.3 60.5 61.2 62.5
12 65.3 62.4 60.2 61.8 62.5
13 65.8 62.5 60.5 61.5 62.2
14 65.7 62.3 60.4 61.4 62.8
15 65.8 62.8 60.2 61.8 62.5
16 65.4 62.5 60.4 61.6 62.4
17 65.8 62.4 60.8 61.7 62.8
18 65.7 62.3 60.5 61.6 62.3
19 65.2 62.5 60.2 61.5 62.3
20 65.5 62.4 60.5 61.2 62.6
21 65.4 62.2 60.4 61.6 62.7
22 65.7 62.5 60.3 61.8 62.5
23 65.3 62.4 60.2 61.3 62.8
24 65.8 62.8 60.8 61.4 62.6
25 65.4 62.5 60.5 61.3 62.3
26 65.7 62.4 60.3 61.3 62.4
27 65.6 62.8 60.2 61.7 62.8
28 65.3 62.5 60.5 61.8 62.5
29 65.4 62.7 60.8 61.5 62.5
30 65.6 62.8 60.5 61.2 62.8
31 65.8 62.5 60.4 61.5 62.4
32 65.3 62.4 60.3 61.2 62.5
33 65.2 62.6 60.8 61.1 62.8
34 65.8 62.3 60.5 61.6 62.3
35 65.4 62.3 60.3 61.7 62.4
36 65.6 62.8 60.2 61.8 62.2
37 65.8 62.5 60.6 61.6 62.6
38 65.7 62.2 60.5 61.6 62.7
39 65.6 62.5 60.4 61.5 62.8
40 65.8 62.4 60.5 61.4 62.5
41 65.2 62.3 60.3 61.3 62.8
42 65.3 62.4 60.6 61.8 62.6
43 65.4 62.8 60.5 61.5 62.5
44 65.2 62.6 60.2 61.3 62.6
45 65.5 62.5 60.8 61.4 62.5
46 65.6 62.8 60.5 61.7 62.4
47 65.7 62.6 60.4 61.4 62.8
48 65.4 62.5 60.8 61.6 62.5
49 65.6 62.4 60.7 61.8 62.3
50 65.4 62.8 60.5 61.6 62.5 PROMEDIO
N50 65.51 62.50 60.48 61.51 62.53 62.506
Desv. Std. (σ) 0.20 0.18 0.19 0.20 0.18 0.192
N10 65.77 62.74 60.73 61.76 62.76 62.753
NEq 65.51 62.51 60.49 61.51 62.53 62.863

Calle 7 N° 233 Fraccionamiento El Caracol, Col. Enrique Cárdenas González, C.P. 89309 Tampico, Tamps.
Tels: 01 (833) 2 56 21 77 / 2 10 94 85 / 2 10 65 06 email: gerenciageneral@asesotam.com.mx
S.A. DE C.V.

RUIDO DE FONDO
dB
I II III IV V
1 58.2 55.4 70.4 71.5 69.8
2 58.6 55.2 70.3 71.2 69.4
3 58.4 55.3 70.6 71.4 69.2
4 58.6 55.6 70.8 71.3 69.8
5 58.4 55.8 70.5 71.6 69.7
6 58.3 55.5 70.4 71.4 69.8
7 58.6 55.2 70.3 71.3 69.2
8 58.5 55.6 70.2 71.5 69.5
9 58.4 55.6 70.6 71.4 69.4
10 58.8 55.3 70.4 71.3 69.8
11 59.2 55.7 70.3 71.4 69.5
12 59.6 55.2 70.5 71.2 69.4
13 59.5 55.8 70.4 71.8 69.6
14 59.3 55.6 70.8 71.5 69.7
15 58.9 55.3 70.5 71.3 69.3
16 58.6 55.7 70.3 71.2 69.6
17 58.7 55.2 70.6 71.8 69.2
18 58.5 55.8 70.4 71.6 69.8
19 58.4 55.4 70.8 71.4 69.7
20 58.8 55.3 70.6 71.8 69.4
21 58.8 55.2 70.5 71.7 69.8
22 58.5 55.4 70.4 71.5 70.5
23 58.7 55.3 70.8 71.4 70.5
24 58.6 55.2 70.5 71.8 70.8
25 58.3 55.4 70.6 71.6 70.6
26 58.5 55.6 70.4 71.5 70.4
27 58.4 55.2 70.5 71.3 70.2
28 58.6 55.3 70.4 71.6 70.5
29 58.5 55.4 70.3 71.5 70.2
30 58.4 55.2 70.5 71.4 70.1
31 58.2 55.3 70.4 71.5 70.4
32 58.3 55.8 70.5 71.4 70.5
33 58.4 55.4 70.4 71.3 70.3
34 58.2 55.2 70.3 71.8 70.6
35 58.7 55.3 70.8 71.7 70.5
36 58.4 55.2 70.7 71.5 70.7
37 58.3 55.4 70.5 71.4 70.4
38 58.5 55.6 70.4 71.2 70.5
39 58.4 55.3 70.6 71.6 70.2
40 58.3 55.2 70.5 71.5 70.4
41 58.3 55.3 70.5 71.2 70.4
42 58.6 55.4 70.3 71.3 70.5
43 58.4 55.8 70.4 71.3 70.2
44 58.7 55.7 70.2 71.4 70.2
45 58.4 55.4 70.5 71.6 70.6
46 58.5 55.2 70.4 71.5 70.5
47 58.2 55.4 70.6 71.4 70.4
48 58.3 55.5 70.3 71.8 70.6
49 58.5 55.7 70.6 71.7 70.5
50 58.4 55.6 70.5 71.5 70.4 PROMEDIO
N50 58.55 55.43 70.48 71.48 70.06 65.200
Desv. Std. (σ) 0.31 0.20 0.16 0.18 0.48 0.264
N10 58.95 55.69 70.68 71.71 70.68 65.539
Neq 58.56 55.43 70.48 71.48 70.09 68.634

Calle 7 N° 233 Fraccionamiento El Caracol, Col. Enrique Cárdenas González, C.P. 89309 Tampico, Tamps.
Tels: 01 (833) 2 56 21 77 / 2 10 94 85 / 2 10 65 06 email: gerenciageneral@asesotam.com.mx
S.A. DE C.V.

RUIDO DE FUENTE (Nocturno) ZC1


dB
A B C D E
1 63.4 63.2 62.8 61.7 62.8
2 63.2 63.2 62.4 61.5 62.6
3 63.5 63.5 62.6 61.2 62.5
4 63.4 63.4 62.5 61.4 62.8
5 63.2 63.8 62.4 61.5 62.5
6 63.5 63.7 62.8 61.4 62.4
7 63.8 63.6 62.5 61.3 62.5
8 63.7 63.2 62.3 61.2 62.4
9 63.7 63.4 62.6 61.5 62.8
10 63.4 63.2 62.4 61.6 62.7
11 63.4 63.6 62.5 61.3 62.6
12 63.3 63.3 62.8 61.4 62.5
13 63.5 63.4 62.5 61.5 62.8
14 63.6 63.5 62.4 61.2 62.6
15 63.7 63.2 62.6 61.6 62.7
16 63.5 63.4 62.3 61.2 62.3
17 63.4 63.5 62.4 61.4 62.4
18 63.4 63.4 62.7 61.8 62.3
19 63.5 63.2 62.5 61.7 62.5
20 63.2 63.8 62.4 61.5 62.4
21 63.4 63.5 62.6 61.2 62.5
22 63.3 63.6 62.3 61.3 62.2
23 63.2 63.4 62.4 61.5 62.8
24 63.5 63.7 62.4 61.4 62.7
25 63.4 63.2 62.5 61.6 62.6
26 63.2 63.2 62.6 61.3 62.5
27 63.8 63.8 62.3 61.5 62.8
28 63.5 63.5 62.4 61.4 62.6
29 63.4 63.2 62.5 61.7 62.5
30 63.5 63.5 62.6 61.8 62.4
31 63.4 63.2 62.4 61.5 62.5
32 63.5 63.4 62.6 61.4 62.8
33 63.8 63.3 62.5 61.3 62.7
34 63.5 63.3 62.4 61.8 62.3
35 63.4 63.6 62.3 61.5 62.4
36 63.2 63.5 62.8 61.3 62.8
37 63.5 63.4 62.7 61.9 62.6
38 63.6 63.7 62.5 61.5 62.5
39 63.2 63.5 62.6 61.4 62.4
40 63.4 63.4 62.4 61.7 62.8
41 63.5 63.4 62.8 61.8 62.7
42 63.2 63.5 62.5 61.3 62.5
43 63.2 63.6 62.7 61.6 62.8
44 63.8 63.2 62.8 61.2 62.4
45 63.5 63.5 62.6 61.8 62.3
46 63.4 63.4 62.5 61.7 62.7
47 63.2 63.2 62.4 61.4 62.6
48 63.4 63.5 62.6 61.5 62.8
49 63.8 63.7 62.7 61.4 62.4
50 63.7 63.6 62.4 61.2 62.5 PROMEDIO
N50 63.45 63.44 62.52 61.48 62.56 62.692
Desv. Std. (σ) 0.18 0.18 0.15 0.19 0.17 0.176
N10 63.69 63.67 62.72 61.72 62.78 62.917
NEq 63.46 63.44 62.53 61.48 62.57 62.755

Calle 7 N° 233 Fraccionamiento El Caracol, Col. Enrique Cárdenas González, C.P. 89309 Tampico, Tamps.
Tels: 01 (833) 2 56 21 77 / 2 10 94 85 / 2 10 65 06 email: gerenciageneral@asesotam.com.mx
S.A. DE C.V.

RUIDO DE FUENTE (Nocturno) ZC2


dB
A B C D E
1 55.3 52.8 53.8 54.6 53.6
2 55.3 52.4 53.2 54.7 53.2
3 55.6 52.6 53.6 54.8 53.4
4 55.1 52.8 53.8 54.9 53.4
5 55.2 52.6 53.5 55.3 53.6
6 55.4 52.2 53.2 55.2 53.2
7 55.6 52.3 53.4 55.8 53.2
8 55.4 52.4 53.5 55.7 53.4
9 55.3 52.5 53.8 55.2 53.5
10 55.7 52.4 53.2 55.4 53.2
11 55.8 52.3 53.4 55.2 53.6
12 55.6 52.4 53.5 55.5 53.4
13 55.7 52.6 53.4 55.4 53.6
14 55.7 52.8 53.2 55.8 53.8
15 55.4 52.6 53.4 55.7 53.2
16 55.7 52.7 53.5 55.2 53.6
17 55.6 52.6 55.2 55.8 53.7
18 55.2 52.8 53.6 55.4 53.4
19 55.4 52.7 53.4 55.6 53.6
20 55.2 52.7 53.2 55.4 53.5
21 55.3 52.2 53.8 55.6 53.5
22 55.4 52.4 53.5 55.7 53.4
23 55.6 52.3 53.4 55.4 53.2
24 55.2 52.3 53.6 55.3 53.4
25 55.3 52.8 53.5 55.6 53.8
26 55.4 52.5 53.1 55.8 53.6
27 55.5 52.6 53.2 55.4 53.5
28 55.2 52.7 53.6 55.6 53.8
29 55.3 52.4 53.8 55.7 53.4
30 55.3 52.3 53.2 55.3 53.2
31 55.2 52.8 53.6 55.8 53.2
32 55.4 52.7 53.8 55.7 53.6
33 55.2 52.7 53.2 55.2 53.2
34 55.3 52.8 53.5 55.4 53.6
35 55.3 52.6 53.4 55.3 53.2
36 55.6 52.8 53.2 55.2 53.5
37 55.4 52.4 53.6 55.4 53.8
38 55.2 52.5 53.5 55.8 53.7
39 55.6 52.4 53.4 55.7 53.5
40 55.5 52.8 53.2 55.2 53.4
41 55.2 52.8 53.6 55.6 53.2
42 55.3 52.6 53.2 55.5 53.8
43 55.4 52.5 53.4 55.2 53.4
44 55.2 52.4 53.5 55.3 53.2
45 55.8 52.3 53.4 55.4 53.5
46 55.7 52.5 53.2 55.6 53.4
47 55.4 52.6 53.8 55.8 53.6
48 55.2 52.2 53.5 55.7 53.8
49 55.3 52.6 53.4 55.4 53.7
50 55.4 52.4 53.2 55.6 53.2 PROMEDIO
N50 55.41 52.54 53.48 55.44 53.47 54.067
Desv. Std. (σ) 0.19 0.19 0.32 0.29 0.20 0.237
N10 55.65 52.79 53.89 55.81 53.73 54.371
NEq 55.41 52.55 53.49 55.45 53.47 54.228

Calle 7 N° 233 Fraccionamiento El Caracol, Col. Enrique Cárdenas González, C.P. 89309 Tampico, Tamps.
Tels: 01 (833) 2 56 21 77 / 2 10 94 85 / 2 10 65 06 email: gerenciageneral@asesotam.com.mx
S.A. DE C.V.

RUIDO DE FUENTE (Nocturno) ZC3


dB
A B C D E
1 63.8 66.8 64.8 65.2 64.5
2 63.2 66.5 64.3 65.8 64.8
3 63.4 66.2 64.8 65.4 64.3
4 63.6 66.4 64.6 65.3 64.7
5 63.2 66.8 64.2 65.2 64.2
6 63.8 66.2 64.8 65.4 64.8
7 63.5 66.7 64.5 65.8 64.5
8 63.4 66.5 64.8 65.3 64.8
9 63.2 66.8 64.2 65.8 64.3
10 63.5 66.5 64.5 65.2 64.3
11 63.4 66.4 64.6 65.7 64.8
12 63.8 66.2 64.8 65.8 64.5
13 63.7 66.6 64.2 65.4 64.7
14 63.5 66.3 64.8 65.3 64.5
15 63.6 66.7 64.5 65.4 64.4
16 63.7 66.8 64.3 65.7 64.2
17 63.7 66.5 64.2 65.8 64.8
18 63.2 66.2 64.8 65.3 64.5
19 63.5 66.5 64.3 65.7 64.3
20 63.2 66.2 64.5 65.4 64.2
21 63.4 66.8 64.2 65.3 64.8
22 63.8 66.7 64.8 65.6 64.5
23 63.2 66.4 64.2 65.7 64.2
24 63.8 66.5 64.5 65.4 64.6
25 63.6 66.8 64.6 65.2 64.6
26 63.5 66.2 64.8 65.4 64.3
27 63.7 66.5 64.3 65.3 64.7
28 63.6 66.2 64.7 65.6 64.2
29 63.5 66.3 64.5 65.7 64.3
30 63.2 66.2 64.8 65.2 64.6
31 63.4 66.4 64.5 65.4 64.3
32 63.2 66.2 64.2 65.3 64.5
33 63.6 66.4 64.4 65.4 64.7
34 63.8 66.3 64.5 65.7 64.8
35 63.5 66.4 64.3 65.8 64.3
36 63.4 66.8 64.5 65.7 64.2
37 63.2 66.7 64.2 65.8 64.8
38 63.4 66.5 64.3 65.3 64.3
39 63.2 66.7 64.3 65.4 64.2
40 63.4 66.4 64.7 65.3 64.8
41 63.8 66.3 64.5 65.2 64.5
42 63.5 66.4 64.3 65.4 64.3
43 63.4 66.8 64.2 65.6 64.2
44 63.6 66.5 64.3 65.3 64.3
45 63.8 66.6 64.5 65.4 64.3
46 63.7 66.4 64.2 65.7 64.2
47 63.4 66.5 64.2 65.3 64.2
48 63.4 66.3 64.8 65.7 64.8
49 63.2 66.4 64.6 65.8 64.5
50 63.8 66.7 64.5 65.3 64.5 PROMEDIO
N50 63.50 66.48 64.48 65.48 64.47 64.882
Desv. Std. (σ) 0.21 0.21 0.22 0.21 0.22 0.215
N10 63.77 66.75 64.76 65.76 64.76 65.158
NEq 63.50 66.49 64.48 65.49 64.48 65.009

Calle 7 N° 233 Fraccionamiento El Caracol, Col. Enrique Cárdenas González, C.P. 89309 Tampico, Tamps.
Tels: 01 (833) 2 56 21 77 / 2 10 94 85 / 2 10 65 06 email: gerenciageneral@asesotam.com.mx
S.A. DE C.V.

RUIDO DE FUENTE (Nocturno) ZC4


dB
A B C D E
1 65.2 63.5 62.8 63.6 64.6
2 65.3 63.4 62.6 63.4 64.6
3 65.4 63.2 62.4 63.5 64.2
4 65.3 63.2 62.8 63.2 64.3
5 65.2 63.8 62.5 63.8 64.2
6 65.3 63.6 62.3 63.6 64.3
7 65.4 63.2 62.4 63.5 64.2
8 65.2 63.4 62.5 63.2 64.5
9 65.3 63.7 62.4 63.4 64.3
10 65.4 63.6 62.5 63.5 64.8
11 65.3 63.5 62.8 63.2 64.6
12 65.5 63.2 62.7 63.4 64.5
13 65.8 63.6 62.8 63.2 64.8
14 65.7 63.5 62.5 63.3 64.7
15 65.4 63.4 62.4 63.8 64.2
16 65.6 63.2 62.6 63.5 64.3
17 65.2 63.4 62.3 63.4 64.2
18 65.8 63.5 62.8 63.2 64.5
19 65.3 63.8 62.5 63.6 64.2
20 65.2 63.6 62.4 63.2 64.3
21 65.4 63.7 62.3 63.4 64.5
22 65.3 63.2 62.2 63.5 64.3
23 65.4 63.2 62.6 63.8 64.5
24 65.2 63.4 62.5 63.7 64.2
25 65.4 63.5 62.4 63.4 64.5
26 65.2 63.4 62.6 63.5 64.4
27 65.3 63.8 62.5 63.4 64.3
28 65.2 63.2 62.8 63.5 64.2
29 65.2 63.6 62.6 63.2 64.8
30 65.4 63.9 62.7 63.6 64.5
31 65.6 64.2 62.5 63.5 64.2
32 65.2 64.1 62.4 63.4 64.5
33 65.6 64.3 62.8 63.7 64.6
34 65.3 64.1 62.3 63.8 64.8
35 65.4 64.1 62.4 63.6 64.5
36 65.8 63.8 62.3 63.2 64.3
37 65.2 63.7 62.5 63.3 64.8
38 65.4 63.5 62.4 63.4 64.7
39 65.8 63.4 62.3 63.2 64.2
40 65.2 63.5 62.4 63.5 64.6
41 65.8 63.2 62.6 63.2 64.5
42 65.4 63.4 62.4 63.7 64.2
43 65.2 63.7 62.7 63.6 64.8
44 65.6 63.5 62.3 63.6 64.3
45 65.3 63.2 62.5 63.5 64.2
46 65.4 63.4 62.4 63.4 64.6
47 65.3 63.5 62.5 63.2 64.2
48 65.4 63.4 62.4 63.5 64.5
49 65.2 63.1 62.6 63.7 64.2
50 65.4 63.5 62.8 63.6 64.3 PROMEDIO
N50 65.39 63.54 62.51 63.46 64.43 63.866
Desv. Std. (σ) 0.19 0.29 0.17 0.19 0.21 0.207
N10 65.63 63.90 62.73 63.70 64.70 64.131
NEq 65.39 63.55 62.52 63.47 64.43 63.981

Calle 7 N° 233 Fraccionamiento El Caracol, Col. Enrique Cárdenas González, C.P. 89309 Tampico, Tamps.
Tels: 01 (833) 2 56 21 77 / 2 10 94 85 / 2 10 65 06 email: gerenciageneral@asesotam.com.mx
S.A. DE C.V.

RUIDO DE FONDO
dB
I II III IV V
1 59.2 58.6 68.7 70.5 71.8
2 59.3 58.5 68.4 70.4 71.8
3 59.6 58.3 68.5 70.2 71.4
4 59.8 58.2 68.2 70.4 71.5
5 59.7 58.5 68.5 70.5 71.2
6 59.6 58.3 68.4 70.3 71.6
7 59.5 58.6 68.3 70.6 71.4
8 59.2 58.5 68.5 70.5 71.8
9 59.8 58.3 68.2 70.6 71.3
10 59.7 58.4 68.4 70.4 71.6
11 59.6 58.2 68.5 70.2 71.4
12 59.5 58.5 68.4 70.8 71.5
13 59.6 58.7 68.3 70.5 71.4
14 59.7 58.3 68.7 70.4 71.1
15 59.4 58.4 68.6 70.3 71.3
16 59.3 58.6 68.6 70.2 71.4
17 59.2 58.5 68.5 70.6 71.5
18 59.6 58.3 68.4 70.4 71.3
19 59.5 58.4 68.3 70.5 71.2
20 59.4 58.6 68.2 70.3 71.8
21 59.3 58.7 68.3 70.2 71.5
22 59.6 58.6 68.4 70.4 71.2
23 59.4 58.5 68.5 70.6 71.8
24 59.7 58.4 68.4 70.4 71.5
25 59.3 58.6 68.2 70.3 71.4
26 59.2 58.7 68.3 70.8 71.3
27 59.8 58.6 68.4 70.6 71.5
28 59.6 58.7 68.3 70.4 71.8
29 59.7 58.3 68.4 70.8 71.2
30 59.6 58.4 68.5 70.5 71.4
31 59.5 58.2 68.3 70.4 71.3
32 60.3 58.6 68.5 70.6 71.2
33 60.4 58.3 68.2 70.8 71.6
34 60.2 58.4 68.7 70.3 71.4
35 60.4 58.7 68.6 70.5 71.8
36 60.8 58.6 68.4 70.8 71.6
37 60.5 58.7 68.7 70.5 71.5
38 60.4 58.3 68.5 70.3 71.4
39 60.6 58.6 68.6 70.8 71.4
40 60.8 58.7 68.4 70.6 71.3
41 60.3 58.2 68.7 70.5 71.2
42 60.2 58.8 68.5 70.3 71.6
43 60.5 58.4 68.4 70.2 71.8
44 60.2 58.2 68.6 70.2 71.6
45 60.8 58.6 68.5 70.5 71.5
46 60.7 58.7 68.4 70.4 71.4
47 60.8 58.4 68.7 70.2 71.6
48 60.5 58.5 68.4 70.8 71.5
49 60.3 58.5 68.6 70.5 71.2
50 60.6 58.6 68.3 70.2 71.8 PROMEDIO
N50 59.88 58.48 68.45 70.46 71.47 65.749
Desv. Std. (σ) 0.52 0.17 0.15 0.19 0.20 0.244
N10 60.55 58.70 68.63 70.70 71.73 66.062
Neq 59.91 58.49 68.45 70.46 71.48 68.307

Calle 7 N° 233 Fraccionamiento El Caracol, Col. Enrique Cárdenas González, C.P. 89309 Tampico, Tamps.
Tels: 01 (833) 2 56 21 77 / 2 10 94 85 / 2 10 65 06 email: gerenciageneral@asesotam.com.mx
S.A. DE C.V.

ANEXO 5 HOJAS DE CAMPO

EL PRESENTE INFORME SOLO AFECTA A LOS OBJETOS SOMETIDOS A PRUEBA


EL PRESENTE REPORTE NO DEBERÁ REPRODUCIRSE PARCIALMENTE SIN LA APROBACIÓN POR ESCRITO DE LA EMPRESA
Acred. ema N° FF-0142-021/11 vigente a partir del 2011-11-18 y AL-0137-012/11 vigente a partir del 2011-12-15 Aprob. PROFEPA N° PFPA-APR-LP-RUIDO-009/2022
Aprob. STPS N° LPSTPS-039/2021

Calle 7 N° 233 Fraccionamiento El Caracol, Col. Enrique Cárdenas González, C.P. 89309 Tampico, Tamaulipas
Tels: 01 (833) 2 56 21 77 / 2 10 94 85 / 2 10 65 06 email: gerenciageneral@asesotam.com.mx
S.A. DE C.V.

DOCUMENTOS DE
ANEXO 6 ACREDITACIÓN

EL PRESENTE INFORME SOLO AFECTA A LOS OBJETOS SOMETIDOS A PRUEBA


EL PRESENTE REPORTE NO DEBERÁ REPRODUCIRSE PARCIALMENTE SIN LA APROBACIÓN POR ESCRITO DE LA EMPRESA
Acred. ema N° FF-0142-021/11 vigente a partir del 2011-11-18 y AL-0137-012/11 vigente a partir del 2011-12-15 Aprob. PROFEPA N° PFPA-APR-LP-RUIDO-009/2022
Aprob. STPS N° LPSTPS-039/2021

Calle 7 N° 233 Fraccionamiento El Caracol, Col. Enrique Cárdenas González, C.P. 89309 Tampico, Tamaulipas
Tels: 01 (833) 2 56 21 77 / 2 10 94 85 / 2 10 65 06 email: gerenciageneral@asesotam.com.mx
S.A. DE C.V.

DOCUMENTOS DE
ANEXO 7 CALIBRACIÓN

EL PRESENTE INFORME SOLO AFECTA A LOS OBJETOS SOMETIDOS A PRUEBA


EL PRESENTE REPORTE NO DEBERÁ REPRODUCIRSE PARCIALMENTE SIN LA APROBACIÓN POR ESCRITO DE LA EMPRESA
Acred. ema N° FF-0142-021/11 vigente a partir del 2011-11-18 y AL-0137-012/11 vigente a partir del 2011-12-15 Aprob. PROFEPA N° PFPA-APR-LP-RUIDO-009/2022
Aprob. STPS N° LPSTPS-039/2021

Calle 7 N° 233 Fraccionamiento El Caracol, Col. Enrique Cárdenas González, C.P. 89309 Tampico, Tamaulipas
Tels: 01 (833) 2 56 21 77 / 2 10 94 85 / 2 10 65 06 email: gerenciageneral@asesotam.com.mx
MeyLab, S.A. de C.V.
Av. Peñuelas No. 5 Int. 18, Col. San Pedrito Peñuelas.
Santiago de Querétaro, Qro. C.P. 76148.
e-mail: servicio.clientes@meylab.com.mx
Tel: 442-804-9407 / 442-804-9408
442-804-9409 / 442-804-9410
www.meylab.com.mx

Certificado de Calibración Calibration Certificate

No. de certificado: ICA- 14577/2023 No. recepción: 13990 Hoja: 1 de 5


Certificate number Reception number Page

Solicitante: ASESORÍA AMBIENTAL, S. A. DE C. V.


Customer
Domicilio: Calle 7 No. 233, Col. Enrique Cárdenas González. Fracc. El Caracol Tampico, Tamaulipas. C.P. 89309
Address

Instrumento: Sonómetro Integrador Marca: Svantek Modelo: SV 973


Instrument Manufacturer Model
No. serie: 104833 Clase o tipo: 2 ID: AA-LAB-SON-05
Serial number Class or type Id number

Micrófono acoplado al sonómetro: Marca del micrófono: Svantek


Microphone attached to the sound level meter Microphone manufacturer
Modelo del micrófono: ST973 No. serie del micrófono: 101998
Microphone model: Microphone serial number:

Patrón de trabajo empleado: Calibrador Acústico Multifunciones Brüel & Kjær 4226.
Standard used
Procedimiento / Método de calibración: PT-SON-01 "Calibración de sonómetros" / Medición directa.
Procedure / Method of calibration
Incertidumbre estimada: Ver hojas 2 a 5.
Estimated uncertainty
Resultados de la calibración: Ver hojas 2 a 5.
Calibration results

Calibración realizada en: MeyLab, S.A. de C.V.


Calibrated performed in
Número de acreditación ante ema A-03: Vigencia a partir del 20 de octubre de 2010.
Accreditation number respect to ema
De acuerdo con las normas: IEC-61672.
In agreement with standard
Condiciones ambientales de medición:
Environmental conditions in measurement

Temperatura: 21.4 ºC Humedad relativa: 47.7 % Presión barométrica: 822.3 hPa


Temperature Relative humidity Barometric pressure

Fecha de Recepción: 2023-enero-25 Fecha de calibración: 2023-febrero-01 Fecha de emisión: 2023-febrero-01


Reception date Calibration date Date issued

T.S.U. Martha Maya Olvera Aprobó: Ing. Ramón Francisco Hernández Aragón
Calibró:
Approved
Calibrated by Metrólogo de Calibración by
Gestor Operativo

Este certificado de calibración cumple con los requisitos de la norma NMX-EC-17025-IMNC-2018


(ISO/IEC 17025:2017) "Requisitos generales para la competencia de los laboratorios de ensayo y
calibración".

Trazabilidad
Traceability
El patrón de referencia es trazable al S. I. a través del CENAM y la trazabilidad del patrón de trabajo se logra a través de los procedimientos
internos del laboratorio sustentados por un sistema de aseguramiento de la calidad implementado en las mediciones.
Este certificado de calibración no puede ser modificado en forma parcial o total sin la autorización del laboratorio. Los resultados declarados son válidos para las
condiciones prevalecientes durante la calibración.
No. de certificado: ICA- 14577/2023 Hoja 2 de 5

I) INDICACIÓN AL NIVEL DE PRESIÓN ACÚSTICA DE REFERENCIA


Se verifica el Nivel de Presión Acústica de referencia con un calibrador acústico patrón. El valor obtenido se presenta en el inciso I-
A. El inciso I-B muestra el valor del sonómetro, en caso de haber realizado algún ajuste. Se toma también el valor de NPA con el
calibrador asociado al sonómetro bajo calibración, en caso de contar con éste.

I-A) VERIFICACIÓN DE LA SENSIBILIDAD: 113.7 dB

I-B) AJUSTE DE LA SENSIBILIDAD: 114.0 dB

I-C) CALIBRADOR ASOCIADO -- dB

II) RUIDO AUTOGENERADO


El micrófono del sonómetro es sustituido por una impedancia eléctrica equivalente y la entrada cortocircuitada. Se toman lecturas
de instrumento en ponderación A, C y Lineal. Se informa el promedio de las lecturas obtenidas.

Ruido ponderación "A" = 14.2 dB(A) Ruido modo lineal = 15.5 dB

Ruido ponderación "C": 13.5 dB(C )

III) LINEALIDAD
a) Linealidad en el intervalo de referencia. La linealidad del instrumento es determinada relativa a un Nivel de Presión Acústica
(NPA) de referencia, ajustada a 94 dB @ 8 kHz. A partir del valor de referencia, se calcula el error en distintos niveles. La
incertidumbre informada es del valor de NPA más bajo.

NPA NPA Leq


Error, Error,
esperado, obtenido, obtenido,
(dB) (dB)
(dB) (dB) (dB)

60 60.0 0.0 60.0 0.0


61 61.0 0.0 61.0 0.0
62 62.0 0.0 62.0 0.0
63 63.0 0.0 63.0 0.0
64 64.0 0.0 64.0 0.0
65 65.0 0.0 65.0 0.0
70 70.0 0.0 70.0 0.0
75 75.0 0.0 75.0 0.0
80 80.0 0.0 80.0 0.0
85 85.0 0.0 85.0 0.0
90 90.0 0.0 90.0 0.0
95 95.0 0.0 95.0 0.0
100 100.0 0.0 100.0 0.0
105 105.0 0.0 105.0 0.0
110 110.0 0.0 110.0 0.0
115 115.0 0.0 115.0 0.0
120 120.0 0.0 120.0 0.0
121 121.0 0.0 121.0 0.0
122 122.0 0.0 122.0 0.0
123 123.0 0.0 123.0 0.0
124 124.0 0.0 124.0 0.0
125 125.0 0.0 125.0 0.0

IEC 61672-1 Tipo 2, (dB) Incertidumbre, k=2, (dB): ± 0.06


Tolerancia (5.5.5) ±1.4

Este certificado de calibración no puede ser modificado en forma parcial o total sin la autorización del laboratorio. Los resultados declarados son válidos para las
condiciones prevalecientes durante la calibración.
No. de certificado: ICA- 14577/2023 Hoja 3 de 5

b) Nivel de linealidad y selector de intervalo. Se inserta una señal de 94 dB @ 1 kHz, ajustando el instrumento en ponderación
A, en el intervalo de referencia y se toman 5 lecturas. La misma operación se realiza en todos los intervalos. Posteriormente, se
repite lo anterior, pero con una señal de referencia con un NPA de 5 dB debajo del límite superior del intervalo bajo calibración.
IEC 61672-1
Referencia: 94 dB @ 1 000 Hz
Punto 5.5.5
NPA NPA Incer., Tolerancia,
Intervalo, Error,
esperado, obtenido, k=2, Tipo 2, (dB)
(dB) (dB)
(dB) (dB) (dB)

-- -- -- -- -- ±1.4
-- -- -- -- --
30-125 94.0 94.0 0.0 ±0.06
-- -- -- -- --
-- -- -- -- --
-- -- -- -- --
-- -- -- -- --

Referencia: (LS-5) dB @ 1 000 Hz

NPA NPA Incer.,


Intervalo, Error,
esperado, obtenido, k=2,
(dB) (dB)
(dB) (dB) (dB)

-- -- -- -- --
-- -- -- -- --
30-125 120.0 120.0 0.0 ±0.06
-- -- -- -- --
-- -- -- -- --
-- -- -- -- --
-- -- -- -- --

IV) VERIFICACIÓN ELÉCTRICA DE LAS MALLAS PONDERADAS


Las mallas ponderadas (A, C y modo Lineal) se calibran empleando una señal eléctrica de referencia de 1 kHz, con un nivel de 45
dB debajo del límite superior en el intervalo de referencia. El instrumento se ajusta en respuesta rápida. Se toma la lectura a 1 kHz y
se cambia la señal de entrada de cada una de las frecuencias de ensayo, ajustando el nivel para obtener el mismo NPA que la señal
de referencia. Se obtiene el error en el valor de la ponderación de la señal medida y la de referencia.

PONDERACIÓN A PONDERACIÓN LINEAL


Atenuación Atenuación Incer., Atenuación Atenuación Incer.,
Frecuencia, Error, Frecuencia, Error,
esperada, obtenida, k=2, esperada, obtenida, k=2,
(Hz) (dB) (Hz) (dB)
(dB) (dB) (dB) (dB) (dB) (dB)

63 -26.2 -26.3 -0.1 ±0.06 63 0.0 0.0 0.0 ±0.06


125 -16.1 -16.2 -0.1 ±0.06 125 0.0 0.0 0.0 ±0.06
250 -8.6 -8.7 -0.1 ±0.06 250 0.0 0.0 0.0 ±0.06
500 -3.2 -3.3 -0.1 ±0.06 500 0.0 0.0 0.0 ±0.06
1 000 0.0 0.0 0.0 ±0.06 1 000 0.0 0.0 0.0 ±0.06
2 000 1.2 1.2 0.0 ±0.06 2 000 0.0 0.0 0.0 ±0.06
4 000 1.0 1.0 0.0 ±0.06 4 000 0.0 0.0 0.0 ±0.06
8 000 -1.1 -1.3 -0.2 ±0.06 8 000 0.0 0.0 0.0 ±0.06
-- -- -- -- -- -- -- -- -- --

Este certificado de calibración no puede ser modificado en forma parcial o total sin la autorización del laboratorio. Los resultados declarados son válidos para las
condiciones prevalecientes durante la calibración.
No. de certificado: ICA- 14577/2023 Hoja 4 de 5

Tolerancia IEC 61672-1


PONDERACIÓN C
Tabla 2 Tipo 2
Error
Atenuación Atenuación Incer.,
Frecuencia, Error, Frecuencia, máximo
esperada, obtenida, k=2,
(Hz) (dB) (Hz) permitido,
(dB) (dB) (dB)
(dB)
63 -0.8 -0.9 -0.1 ±0.06 63 ±2.5
125 -0.2 -0.2 0.0 ±0.06 125 ±2.0
250 0.0 0.0 0.0 ±0.06 250 ±1.9
500 0.0 0.0 0.0 ±0.06 500 ±1.9
1 000 0.0 0.0 0.0 ±0.06 1,000 ±1.4
2 000 -0.2 -0.2 0.0 ±0.06 2,000 ±2.6
4 000 -0.8 -0.8 0.0 ±0.06 4,000 ±3.6
8 000 -3.0 -3.2 -0.2 ±0.06 8,000 ±5.6
-- -- -- -- -- 16,000 +6.0;-∞

V) PONDERACIONES EN TIEMPO Y FRECUENCIA A 1 kHz.

Se inserta una señal de referencia con un nivel de 94 dB @ 1 kHz, ajustando el instrumento en ponderación A y respuesta rápida. Se
registran los resultados para esa combinación. Se cambia la malla de ponderación a C y se toman 5 lecturas. Lo mismo se realiza
cambiando el sonómetro a modo lineal. De igual forma, con el sonómetro ajustado en ponderación A, se toman lecturas en tiempo
de respuesta lenta, así como en impulso. Se informa el error respecto a la referencia (ponderación A y respuesta rápida).

Ajuste (ponderación- Tolerancia


A-F C-F Lin-F A-S A-I
respuesta temp.) IEC 61672-1
Punto 5.4.14
Valor esperado, (dB) 94.00 94.00 94.00 94.00 94.00
Valor obtenido, (dB) 94.00 94.00 94.00 94.00 94.00 Tipo 2, (dB)
Error, (dB) 0.00 0.00 0.00 0.00 0.00 ±0.4
Incer., k=2, (dB) ±0.06 ±0.06 ±0.06 ±0.06 ±0.06

VI) RESPUESTA A TONOS RÁFAGA

La calibración de las respuestas temporales se lleva a cabo con una señal de referencia de 4 000 Hz, con un NPA de 3 dB debajo del
límite superior del intervalo de referencia. La señal debe tener una duración de 200 ms, 2 ms y 0.25 ms, para respuesta rápida y
tiempo de promediación; 200 ms y 2 ms para respuesta lenta.

Duración Tolerancia
NPA NPA Incer.,
Respuesta tono Error, IEC 61672-1
esperado, obtenido, k=2,
tipo: ráfaga, (dB) Tabla 3.
(dB) (dB) (dB)
(ms) Tipo 2, (dB)

200 121.0 121.1 +0.1 ±0.06 ±1.3


FAST 2 104.0 104.0 0.0 ±0.06 +1.3,-2.3
0.25 95.0 94.9 -0.1 ±0.06 +1.8,-5.3
200 114.6 114.5 -0.1 ±0.06 ±1.3
SLOW
2 95.0 94.9 -0.1 ±0.06 +1.3,-5.3

Este certificado de calibración no puede ser modificado en forma parcial o total sin la autorización del laboratorio. Los resultados declarados son válidos para las
condiciones prevalecientes durante la calibración.
No. de certificado: ICA- 14577/2023 Hoja 5 de 5

VII) RESPUESTA ACÚSTICA A LA FRECUENCIA DE LAS MALLAS PONDERADAS A Y C

Se ajusta el sonómetro en respuesta rápida, en la ponderación (A o C) que se va a verificar. Se inserta una señal de referencia de 94
dB @ 1000 Hz del calibrador acústico multifunciones Brüel & Kjær 4226 y se toma la lectura correspondiente. Se cambia la
frecuencia del calibrador acústico multifunciones Brüel & Kjær 4226 a 125 Hz y se toman las lecturas correspondientes, repitiendo
el proceso en cada frecuencia.

Ponderación A
Valor Valor Incertidumbre,
Frecuencia, Error,
esperado, obtenido, k=2,
(Hz) (dB) Tolerancia IEC 61672-1
(dB A) (dB A) (dB)
Tabla 2 Tipo 2
125 78.0 78.2 +0.3 ±0.20
250 85.4 85.5 +0.1 ±0.20 Error
Frecuencia, máximo
500 90.8 90.9 +0.1 ±0.20 (Hz) permitido,
1 000 94.1 94.0 -0.1 ±0.20 (dB)
2 000 95.3 94.4 -0.9 ±0.20 125 ±2.0
4 000 95.1 92.6 -2.4 ±0.20 250 ±1.9
500 ±1.9
Ponderación C 1 000 ±1.4
Valor Valor Incertidumbre, 2 000 ±2.6
Frecuencia, Error,
esperado, obtenido, k=2, 4 000 ±3.6
(Hz) (dB)
(dB C) (dB C) (dB)
125 93.9 94.1 +0.2 ±0.20
250 94.0 94.2 +0.2 ±0.20
500 94.0 94.2 +0.2 ±0.20
1 000 94.1 94.0 -0.1 ±0.20
2 000 93.9 93.1 -0.8 ±0.20
4 000 93.3 90.9 -2.4 ±0.20

INCERTIDUMBRE: La incertidumbre se obtiene multiplicando la incertidumbre estándar combinada por un factor de k=2
correspondiente a un nivel de confianza del 95.45 % aproximadamente. La incertidumbre estándar fue estimada de acuerdo a NMX-
CH-140-IMNC-2002. Para la evaluación de la conformidad con la Norma Internacional CEI/IEC 61672-1, se toma en
cuenta el error más la incertidumbre.
Nota: Los resultados expresados en este certificado de calibración son el promedio de 5 lecturas tomadas para cada una de las
pruebas.

OBSERVACIONES: Este documento “Certificado de Calibración” es propiedad del cliente, su reproducción parcial o total es
responsabilidad del mismo. Tiene validez en su forma original (íntegro en su número total de páginas), con las firmas del personal
responsable por la calibración. Los periodos de calibración son responsabilidad del cliente.

INSTRUMENTACIÓN EMPLEADA
Generador de forma de onda Calibrador acústico multifunciones Atenuador
Marca: Hewlett-Packard Marca: Brüel & Kjaer Marca: Hewlett-Packard
Modelo: 33120A Modelo: 4226 Modelo: 355D
Nº Serie: US34015044 Nº Serie: 2902876 Nº Serie: 1204A26748

Calibrador acústico
Marca: 3M
Modelo: AC-300
Nº Serie: AC300008997
La trazabilidad se mantiene a través del patrón de referencia Calibrador Acústico Multifunciones Marca: Brüel & Kjær Modelo:
4226 calibrado por el CENAM con No. de certificado CNM-CC-510-208/2022 incertidumbre ±0.09 dB y el Generador Marca:
HP Modelo: 33120A calibrado por CANHEFERN con No. de Certificados: CA-CE-35702-11 y CA-CE-35702-21.

Fin del certificado


Este certificado de calibración no puede ser modificado en forma parcial o total sin la autorización del laboratorio. Los resultados declarados son válidos para las
condiciones prevalecientes durante la calibración.
MeyLab, S.A. de C.V.
Av. Peñuelas No. 5 Int. 18, Col. San Pedrito Peñuelas.
Santiago de Querétaro, Qro. C.P. 76148.
e-mail: servicio.clientes@meylab.com.mx
Tel: 442-804-9407 / 442-804-9408
442-804-9409 / 442-804-9410
www.meylab.com.mx

Certificado de Calibración Calibration Certificate

No. de certificado: ICA- 14926/2023 No. recepción: 14241 Hoja: 1 de 2


Certificate number Reception number page
Solicitante: ASESORIA AMBIENTAL, S. A. DE C. V.
Customer

Domicilio: Calle 7 No. 233. Col. Enrique Cárdenas González, Fracc. El Caracol. Tampico, Tamaulipas. C.P. 89309
Address

Instrumento: Calibrador Acústico Marca: Metrosonics Modelo: QC-10M


Instrument Manufacturer Model

No. Serie: PEE020010 Clase o tipo: 1 ID: AA-LAB-CAL-02


Serial number Class or type Id number

Patrón de trabajo empleado: Pistófono Brüel & Kjær 4228.


Standard used
Procedimiento / Método de calibración: PT-CAL-01: "Calibración de calibradores acústicos" / medición por comparación.
Procedure / Method of calibration
Incertidumbre estimada: Ver hoja 2 de 2.
Calibration results
Resultados de la calibración: Ver hoja 2 de 2.
Estimated uncertainty

Calibración realizada en: MeyLab, S.A. de C.V.


Calibrated performed in

Número de acreditación ante ema A-03: Vigencia a partir del 20 de Octubre del 2010.
Acreditation number respect to ema

De acuerdo con la norma: IEC-60942.


In agreement with standard

Condiciones ambientales de medición:


Environmental conditions in measurement
Temperatura: 21.7 °C Humedad relativa: 44.0 % Presión barométrica: 817.9 hPa
Temperature Relative humidity Barometric pressure

Fecha de Recepción: 2023-abril-18 Fecha de calibración: 2023-mayo-09 Fecha de emisión: 2023-mayo-09


Reception date Calibration date Date issued

Calibró: Ing. Wendy Montserrat Romero Ruiz Aprobó: Ing. Ramón Francisco Hernández Aragón
Calibrate by Metrólogo de Calibración Approved by Gestor Operativo

Este certificado de calibración cumple con los requisitos de la norma NMX-EC-17025-IMNC-2018 (ISO/IEC
17025:2017) "Requisitos generales para la competencia de los laboratorios de ensayo y calibración".

Trazabilidad
Traceability
El patrón de referencia es trazable al SI a través del CENAM, y la trazabilidad del patrón se logra a través de los procedimientos internos del laboratorio sustentados
por un sistema de gestión de la calidad implementado en las mediciones.
Este certificado de calibración no puede ser modificado en forma parcial o total sin la autorización del laboratorio. Los resultados declarados son válidos para las
condiciones prevalecientes durante la calibración.
No. de certificado: ICA- 14926/2023 Hoja 2 de 2
I) NIVEL DE PRESIÓN ACÚSTICA (NPA) EMITIDO
Se acopla un pistófono Brüel & Kjær 4228 a un micrófono patrón Brüel & Kjær 4192 para obtener la señal de referencia.
Después, el pistófono se sustituye por el calibrador acústico bajo calibración en el micrófono. Posteriormente, se calcula el
NPA emitido por el calibrador acústico con las señales registradas en cada medición.
NPA Nominal: 102 dB

NPA 101.90 dB Ue (k=2) = 0.12 dB Clase de calib. LS 1 2


referido a 1013 hPa:
Tolerancia NPA, (dB) ±0.1 ± 0.25 ± 0.40
II) FRECUENCIA Ue Máxima Permitida, (dB) 0.1 0.15 0.35
Es obtenida empleando un contador de frecuencia el cual proporciona el valor del tono generado.

Frecuencia Frecuencia
Instrumento
mínima, máxima,
Clase
Frecuencia: 1 002.7 Hz Ue (k=2) = 0.20% (Hz) (Hz)
LS 993 1 007
1 993 1 007
2 983 1 017

III) DISTORSIÓN AL TERCER ARMÓNICO


Es obtenida empleando una relación de presiones respecto a la frecuencia central, la segunda y tercera armónica del tono
generado por el calibrador.
DA(3º ARMÓNICO): 0.32 % Ue (k=2) = 0.35% Instrumento Tolerancia,
Clase (%)
LS 2.0
1 2.5
2 3.0

NOTA: El Nivel de Presión Acústica emitido por el calibrador reportado en éste certificado de calibración, debe ser corregido
para el valor de presión barométrica del lugar donde es empleado (ver instrucciones del fabricante).

INCERTIDUMBRE: La incertidumbre se obtuvo multiplicando la incertidumbre estándar combinada por un factor de k=2
correspondiente a un nivel de confianza del 95.45 % aproximadamente. La incertidumbre estándar fue estimada de acuerdo a
NMX-CH-140-IMNC-2002. Para la evaluación de la conformidad con la Norma Internacional CEI/IEC 60942, se toma
en cuenta el error más la incertidumbre.
Nota: Los resultados expresados en este certificado de calibración son el promedio de 5 lecturas tomadas para cada una de las
pruebas

OBSERVACIONES:
Este documento “Certificado de Calibración” es propiedad del cliente, su reproducción parcial o total es responsabilidad del
mismo. Tiene validez en su forma original (íntegro en su número total de páginas), con las firmas del personal responsable por la
calibración. Los periodos de calibración son responsabilidad del cliente.

INSTRUMENTACIÓN EMPLEADA
Pistófono Multímetro Sonómetro
Marca: Brüel & Kjær Marca: Hewlett Packard Marca: Quest
Modelo: 4228 Modelo: 34401A Modelo: Sound Pro
Nº Serie: 2836196 Nº Serie: US36097094 Nº Serie: BLL010009
Tipo: 1
Micrófono Filtro con bandas de 1/3 de octava
Marca: Brüel & Kjær Marca: Quest
Modelo: 4192 Modelo: Int. a sonómetro Sound Pro
Nº Serie: 2802752

La trazabilidad se mantiene a través del patrón de referencia Pistófono marca: Brüel & Kjær, modelo: 4228, calibrado por el CENAM con
No. de Certificado: CNM-CC-510-125/2023, incertidumbre ±0.05 dB (k=2); y el micrófono marca: Brüel & Kjaer, modelo: 4192, calibrado
por el CENAM con No. de Certificado: CNM-CC-510-127/2023, incertidumbre ±0.08 dB (k=2).

Fin del certificado


Este certificado de calibración no puede ser modificado en forma parcial o total sin la autorización del laboratorio. Los resultados declarados son válidos para las
condiciones prevalecientes durante la calibración.

También podría gustarte