Está en la página 1de 4

PARAMETROS PARA EL DISEÑO HIDRAULICO DE COLECTORES

PROYECTO: "MEJORAMIENTO DEL SERVICIO DE AGUA POTABLE Y ALCANTARILLADO SANITARIO EN LA CALLE LOS PESCADORES ,CALLE S/N 0031, CALLE LOS PINOS,
CALLE LAS FLORES Y CALLELAS PETUNIAS, EN EL AAHH TUPAC AMARU DISTRITO DE PIMENTEL -PROVINCIA DE CHICLAYO-DEPARTAMENTO DE LAMBAYEQUE"

UBICACIÓN : DISTRITO : PIMENTEL


PROVINCIA : CHICLAYO
DEPARTAMENTO : LAMBAYEQUE

POBLACIÓN ACTUAL ( Po ) 220 Hab.

TASA DE CRECIMIENTO ( r ) 2.64%

PERIODO DE DISEÑO ( t ) 20 Años

POBLACIÓN FUTURA ( Pf )

Pf = Po ( 1+ r )^t 370 Hab.

DOTACIÓN 220 Lts/hab/día


CAUDAL MEDIO ( Q med )

Q med = C * Pf * Dot. / 86400 0.754 Lts/Seg.

COEF. VARIAC. DIAR. ( K1 ) 1.3 Reglamento nacinal de Edificaciones


COEF. VARIAC. HOR. ( K2 ) 2.0 Reglamento nacinal de Edificaciones
CAUDAL MAX. HOR. ( Q mh )

Q mh = K2 . Q med. 1.51 Lts/Seg.


CAUDAL DE INFILTRACIÓN CAUDAL DE CONEXIONES ERRADAS
LONG. TOTAL DEL COLEC. 756.12 mts 0.0002 lst/seg/mts < Qi < 0.0008 Lts/mts/seg 5% -10% del Caudal Max. Horario ( Qmh )
CAUDAL DE INFILTRACIÓN ( Qi ) 0.38 Lts/Seg. Rango Qi : 0.0005 Lts/met/seg. Qe : Lts/seg.

CAUDAL DE DISEÑO ( Qd ) 1.89 Lts/Seg. Qd = Qmh + Qi

CAUDAL UNITARIO ( Qu ) 0.0025 Lts/seg./ml


COEF. RUGO. ( n ) 0.009
TIRANTE( h ) : ( 0.75 D Ó 0.50 D) 0.75
PROYECTO: "MEJORAMIENTO DEL SERVICIO DE AGUA POTABLE Y ALCANTARILLADO SANITARIO EN LA CALLE LOS
PESCADORES ,CALLE S/N 0031, CALLE LOS PINOS, CALLE LAS FLORES Y CALLELAS PETUNIAS, EN EL AAHH TUPAC AMARU
DISTRITO DE PIMENTEL -PROVINCIA DE CHICLAYO-DEPARTAMENTO DE LAMBAYEQUE"

BUZON ARRANQUE BZ. BUZON LLEGADA


BZ. SAL. LONGITUD PENDIENTE (o/oo)
COTA TAPA COTA FONDO TUBERIA PROF. LLEG. COTA TAPA COTA FONDO PROFUNDIDAD AA.HH
B01 8.48 7.48 01 1.00 75.76 7.13 B02 8.34 6.94 1.40 TUPAC AMARU
B02 8.34 6.94 03 1.40 60.72 5.76 B05 8.19 6.59 1.60 TUPAC AMARU
B03 8.19 7.34 02 0.85 32.43 12.33 B02 8.34 6.94 1.40 TUPAC AMARU
B04 8.46 7.26 10 1.20 75.12 8.92 B05 8.19 6.59 1.60 TUPAC AMARU
B05 8.19 6.59 04 1.60 49.15 6.71 B07 8.36 6.26 2.10 TUPAC AMARU
B06 8.67 7.17 11 1.50 76.30 11.93 B07 8.36 6.26 2.10 TUPAC AMARU
B07 8.36 6.26 05 2.10 52.89 6.81 B09 8.00 5.90 2.10 TUPAC AMARU
B08 8.80 7.20 12 1.60 73.84 17.61 B09 8.00 5.90 2.10 TUPAC AMARU
B09 8.00 5.90 06 2.10 55.70 5.39 B11 7.55 5.60 1.95 TUPAC AMARU
B10 8.42 6.82 13 1.60 74.17 16.45 B11 7.55 5.60 1.95 TUPAC AMARU
B11 7.55 5.60 07 1.95 61.32 6.03 B12 8.73 5.23 3.50 TUPAC AMARU
B12 8.73 5.23 08 3.50 59.50 5.71 B13 6.59 4.89 1.70 TUPAC AMARU
B13 6.59 4.89 9 1.70 9.22 15.18 B14 6.16 4.75 1.41 TUPAC AMARU

Long. Total= 756.12 m


PROYECTO: "MEJORAMIENTO DEL SERVICIO DE AGUA POTABLE Y ALCANTARILLADO SANITARIO EN LA CALLE LOS PESCADORES ,CALLE S/N 0031, CALLE LOS
PINOS, CALLE LAS FLORES Y CALLELAS PETUNIAS, EN EL AAHH TUPAC AMARU DISTRITO DE PIMENTEL -PROVINCIA DE CHICLAYO-DEPARTAMENTO DE
LAMBAYEQUE"

Cota de Buzones Qr
Tensió Profundidad
Buzón Gasto S Ø Qr (asum Qp fq fd d Vp fv Vr θ
Long. n t (m)
AA.HH Tapa Fondo Tapa Fondo tub imos)
(m)
Inic Final Inic.(m) Inic.(m) Fin.(m) Fin.(m) o/oo mm lps lps lps (cm) m/s (m/s) (rad) (pascal) Inicial Final
TUPAC AMARU B01 B02 75.76 0.189 8.48 7.48 8.34 6.94 01 7.13 190.2 0.19 1.500 34.98 0.043 0.14 2.645 1.231 0.49 0.61 1.53 1.15 1.00 1.40
TUPAC AMARU B02 B05 60.72 0.1515 8.34 6.94 8.19 6.59 03 5.76 190.2 0.42 1.500 31.46 0.048 0.15 2.808 1.107 0.52 0.58 1.58 1.02 1.40 1.60
TUPAC AMARU B03 B02 32.43 0.0809 8.19 7.34 8.34 6.94 02 12.33 190.2 0.08 1.500 46.02 0.033 0.12 2.296 1.620 0.45 0.73 1.42 1.75 0.85 1.40
TUPAC AMARU B04 B05 75.12 0.1874 8.46 7.26 8.19 6.59 10 8.92 190.2 0.19 1.500 39.13 0.038 0.13 2.491 1.377 0.47 0.65 1.48 1.36 1.20 1.60
TUPAC AMARU B05 B07 49.15 0.1226 8.19 6.59 8.36 6.26 04 6.71 190.2 0.73 1.500 33.95 0.044 0.14 2.689 1.195 0.50 0.60 1.54 1.10 1.60 2.10
TUPAC AMARU B06 B07 76.30 0.1903 8.67 7.17 8.36 6.26 11 11.93 190.2 0.19 1.500 45.25 0.033 0.12 2.315 1.593 0.45 0.72 1.43 1.70 1.50 2.10
TUPAC AMARU B07 B09 52.89 0.1319 8.36 6.26 8.00 5.90 05 6.81 190.2 1.05 1.500 34.18 0.044 0.14 2.679 1.203 0.50 0.60 1.54 1.11 2.10 2.10
TUPAC AMARU B08 B09 73.84 0.1842 8.80 7.20 8.00 5.90 12 17.61 190.2 0.18 1.500 54.98 0.027 0.11 2.115 1.935 0.43 0.83 1.36 2.31 1.60 2.10
TUPAC AMARU B09 B11 55.70 0.1389 8.00 5.90 7.55 5.60 06 5.39 190.2 1.38 1.500 30.41 0.049 0.15 2.861 1.070 0.55 0.59 1.59 1.02 2.10 1.95
TUPAC AMARU B10 B11 74.17 0.185 8.42 6.82 7.55 5.60 13 16.45 190.2 0.19 1.500 53.14 0.028 0.11 2.147 1.870 0.43 0.81 1.37 2.19 1.60 1.95
TUPAC AMARU B11 B12 61.32 0.153 7.55 5.60 8.73 5.23 07 6.03 190.2 1.71 1.715 32.19 0.053 0.16 2.957 1.133 0.53 0.60 1.62 1.08 1.95 3.50
TUPAC AMARU B12 B13 59.50 0.1484 8.73 5.23 6.59 4.89 08 5.71 190.2 1.86 1.863 31.32 0.059 0.16 3.109 1.102 0.55 0.60 1.66 1.07 3.50 1.70
TUPAC AMARU B13 B14 9.22 0.023 6.59 4.89 6.16 4.75 09 15.18 190.2 1.89 1.886 51.06 0.037 0.13 2.443 1.797 0.47 0.84 1.47 2.28 1.70 1.41

Longitud de Tuberia
q prop. = 0.0025 l/s q= 1.8861 l/s
Longitud total = 756.12 m
Ø 8" = #REF!
PROYECTO: "MEJORAMIENTO DEL SERVICIO DE AGUA POTABLE Y ALCANTARILLADO SANITARIO EN LA
CALLE LOS PESCADORES ,CALLE S/N 0031, CALLE LOS PINOS, CALLE LAS FLORES Y CALLELAS
PETUNIAS, EN EL AAHH TUPAC AMARU DISTRITO DE PIMENTEL -PROVINCIA DE CHICLAYO-
DEPARTAMENTO DE LAMBAYEQUE"

Cota de Buzones Qr
Tensió
Buzón Gasto S Ø Qr (asum Vr
Long. n t
AA.HH Tapa Fondo Tapa Fondo tub imos)
(m)
Inic Final Inic.(m) Inic.(m) Fin.(m) Fin.(m) o/oo mm lps lps (m/s) (pascal)
TUPAC AMARU B01 B02 75.76 0.189 8.48 7.48 8.34 6.94 01 7.03 190.2 0.19 1.500 0.61 1.15
TUPAC AMARU B02 B05 60.72 0.1515 8.34 6.94 8.19 6.59 03 5.67 190.2 0.42 1.500 0.58 1.02
TUPAC AMARU B03 B02 32.43 0.0809 8.19 7.34 8.34 6.94 02 11.88 190.2 0.08 1.500 0.73 1.73
TUPAC AMARU B04 B05 75.12 0.1874 8.46 7.26 8.19 6.59 10 8.80 190.2 0.19 1.500 0.66 1.37
TUPAC AMARU B05 B07 49.15 0.1226 8.19 6.59 8.36 6.26 04 6.55 190.2 0.73 1.500 0.59 1.10
TUPAC AMARU B06 B07 76.30 0.1903 8.67 7.17 8.36 6.26 11 11.90 190.2 0.19 1.500 0.73 1.74
TUPAC AMARU B07 B09 52.89 0.1319 8.36 6.26 8.00 5.90 05 6.66 190.2 1.05 1.500 0.60 1.10
TUPAC AMARU B08 B09 73.84 0.1842 8.80 7.20 8.00 5.90 12 17.37 190.2 0.18 1.500 0.84 2.33
TUPAC AMARU B09 B11 55.70 0.1389 8.00 5.90 7.55 5.60 06 5.27 190.2 1.38 1.500 0.59 1.02
TUPAC AMARU B10 B11 74.17 0.185 8.42 6.82 7.55 5.60 13 16.23 190.2 0.19 1.500 0.82 2.21
TUPAC AMARU B11 B12 61.32 0.153 7.55 5.60 8.73 5.23 07 5.92 190.2 1.71 1.715 0.60 1.07
TUPAC AMARU B12 B13 59.50 0.1484 8.73 5.23 6.59 4.89 08 5.61 190.2 1.86 1.863 0.60 1.07
TUPAC AMARU B13 B14 9.22 0.023 6.59 4.89 6.16 4.75 09 15.36 190.2 1.89 1.886 0.86 2.34