TABLERO DE DISTRIBUCIÓN - TD AA

C-1 3x20A RESERVA

C-2 2x20A 2 - 1 x 2.5 mm² NH-80 + 1 x 2.5 mm² (T) Ø 15 mm PVC - SEL EXTRACTORES ESTERILIZACION

C-3 2x20A 2 - 1 x 2.5 mm² NH-80 + 1 x 2.5 mm² (T) Ø 15 mm PVC - SEL AA. 02

C-4 2x20A 2 - 1 x 2.5 mm² NH-80 + 1 x 2.5 mm² (T) Ø 15 mm PVC - SEL AA. 03

C-5 2x32A 2 - 1 x 2.5 mm² NH-80 + 1 x 2.5 mm² (T) Ø 15 mm PVC - SEL AA. SALA REUNIONES

C-6 2x32A 2 - 1 x 2.5 mm² NH-80 + 1 x 2.5 mm² (T) Ø 15 mm PVC - SEL AA. LOGISTICA
IG
3 - 1 x 6 mm² + 1 x 6 mm² (N) + 1 x 4 mm² (T) NH-80 3x40 A
Ø 40 mm PVC - SAP C-7 2x20A 2 - 1 x 4 mm² NH-80 + 1 x 4 mm² (T) Ø 15 mm PVC - SEL AA.INFORMATICA
DEL CN - 14 DE TD - 8N
C-8 2x20A 2 - 1 x 2.5 mm² NH-80 + 1 x 2.5 mm² (T) Ø 15 mm PVC - SEL AA. ESTERILIZACION

C-9 2x20A 2 - 1 x 2.5 mm² NH-80 + 1 x 2.5 mm² (T) Ø 15 mm PVC - SEL AA. ALMACEN FARMACIA

C-10 2x20A 2 - 1 x 2.5 mm² NH-80 + 1 x 2.5 mm² (T) Ø 15 mm PVC - SEL AA. CONTABILIDAD

C-11 2x16A 2 - 1 x 2.5 mm² NH-80 + 1 x 2.5 mm² (T) Ø 15 mm PVC - SEL AA. ADMINISTRACION
1x6 mm2 NH-80 Ø 20 MM PVC - P
C-12 2x16A 2 - 1 x 2.5 mm² NH-80 + 1 x 2.5 mm² (T) Ø 15 mm PVC - SEL AA. RECURSOS HUMANOS

TABLERO METALICO CON INTERRUPTORES AUTOMATICOS


Pozo a Tierra N°01: TERMOMAGNETICOS CON FRENTE MUERTO Y TAPA
< a 10 Ohmios
(Z.U.)

LEYENDA
SIMBOLO DESCRIPCION
CONDUCTO DE CABLES TUBERIA PVC SAP

TABLERO DE DISTRIBUCION 380 / 220 V


TABLERO DE DISTRIBUCIÓN - TD ASC
KW-H BANCO DE MEDIDORES MONOFASICOS

CAJA DE PASE F.G CON TAPA


C-1 3x80A 3 - 1 x 16 mm² + 1 x 10 mm² (N) NH-80 + 1 x 16 mm² (T) Ø 25 mm PVC - SEL ASCENSOR 01
POZO DE PUESTA A TIERRA
C-2 3x63A 3 - 1 x 16 mm² + 1 x 10 mm² (N) NH-80 + 1 x 16 mm² (T) Ø 25 mm PVC - SEL ASCENSOR 02
IG TRANSFORMADOR DISTRIB SECO 200 KVA
3 - 1 x 35 mm² + 1 x 16 mm² + 1 x 16 mm² (T) NH-80 3x40 A
Ø 40 mm PVC - SAP C-3 2x20A 2 - 1 x 4 mm² NH-80 + 1 x 4 mm² (T) Ø 15 mm PVC - SEL ILUMINACION CABINA ASC.01
DEL CN - 2 DE T - G GE GRUPO ELECTROGENO
1x6 mm2 NH-80 Ø 20 MM PVC - P
C-4 2x20A RESERVA
2x32A
INTERRUPTOR TERMOMAGNETICO

TABLERO METALICO CON INTERRUPTORES AUTOMATICOS ID


2x40 A
Pozo a Tierra N°01: TERMOMAGNETICOS CON FRENTE MUERTO Y TAPA
< a 10 Ohmios INTERRUPTOR DIFERENCIAL
(Z.U.) 30 mA

DERIVACION DE TIERRA

CUADRO DE CARGAS GENERALES


P.I. P.C
DESCRIPCION N° (kW) F. Demanda F. Sim (kW)

ALUMBRADO GENERAL 18.00 0.30 1.00 5.40

TOMACORRIENTES 31.80 0.30 1.00 9.54

PEQUEÑAS UTILIZACIONES 4 1.50 1.00 0.70 4.20

MOTORES Y AIRE ACONDICIONADO 18.00 1.00 0.70 13.00

ASCENSOR 2 7.00 0.80 1.00 10.20

EQUIPOS IMAGENELOGIA 54.00 0.90 0.65 31.60

ESTERILIZACION Y LAVANDERIA 18.00 1.00 0.60 10.80

PROFESIONAL:
FACTOR DE SIMULTANIEDAD 0.6 0.60
ING. MEC. ELECT. MERLY HUAMAN BOCANEGRA Reg. CIP Nº 291415

MAXIMA DEMANDA EDIFICIO EXIST. 151.80 51.00 ESPECIALIDAD / PLANO LAMBAYEQUE


Departamento:
AUMENTO DEMANDA EDIFICION INSTALACIONES ELECTRICAS Provincia: CHICLAYO
10.00 0.90 0.80 7.20 Distrito: CHICLAYO
EXIST.
HOSPITAL METROPOLITANO S.A Ca. Manuel María Izaga Nº154
DEMANDA TOTAL PROYECTADA 162.00 0.70 0.60 58.00
REPRESENTANTE: LAMINA:
JESSICA RODRIGUEZ BECERRA
PLANO :

DIAGRAMAS UNIFILARES DU-05


ESCALA : SIN ESCALA FECHA: JUNIO 2023