Documentos de Académico
Documentos de Profesional
Documentos de Cultura
NORTE
RO
CED
D. F.
LE
O
ROB
IV
RESIDENCIAL
TECAMACHALCO
OL
BOSQUES DE CIDROS
EL
RESIDENCIAL A
LA COORDILLERA ALM
AP
EL
AD
LOM
Límite de terreno
TR-01
300 kVA
CO
h=1.08
V ER IG
AL
OU CH
IRAPUATO
L A
TR-500kVA AM
EC
.T
AV
planta de
CO
emergencia 10
L 6 7 8
9
HA
T1 T2
4
A C
AM acceso acceso planta
T EC T1
N +62.10
N +58.80
19
18PHPA
T2
AV
16 N +52.30 PHPB N +52.30 16 SKY
15 N +49.10 N +49.10 15
14 N +45.90 N +45.90 14
13 N +42.70 N +42.70 13
12 N +39.50 N +39.50 12
11 N +36.30 N +36.30 11
10 N +33.10 N +33.10 10
9 N +29.90 N +29.90 9
8 N +26.70 N +26.70 8
7 N +23.50 N +23.50 7
6 N +20.30 N +20.30 6
5 N +17.10 N +17.10 5
4 N +13.90 N +13.90 4
3 N + 10.70 N + 10.70 3
2 N + 7.50 N + 7.50 2
1 N + 4.30 N + 4.30 1
E1 N +0.70 N +0.70 E1
5 I
Ø75
I I I I I
G.P.C.I.Ø50 E2
E3
E4
N - 2.30
N - 5.30
N - 8.30
N - 2.30
N - 5.30
N - 8.30
E2
E3
E4
N - 11.50 N - 11.50
I
alzado
Ø75 Ø75 G.P.C.I.Ø50 S.C.P.C.I.Ø200
6
I I I I I I I I I I I I I I I I I I I I I I I I I I
I
I
I
REVISIONES EJECUTIVOS
I
I
I
S.C.P.C.I.Ø200
I
No. FECHA CONCEPTO REVISO
I
I
Límite de terreno
I
I
I
I
PROYECTOR
I
I
I
I
I
HUECO
I
HUECO ELEVADORES
I
Ø75 ESCALERAS
I
I
NOTAS GENERALES
I
I
I
I
1.-CONSULTESE ESTE PLANO SOLO PARA LA INSTALACION
I
8 ALIMENTACION SHUT
DE BASURA Ø25 Ø25 I
I
I
I
I
DE PCI
2.-LAS TUBERIAS SERAN DE ACERO DE ALTA RESISTENCIA,
Ø13 MARCA VILLACERO, LINEA CONTRA INCENDIO SPRINKLER.,
I
ALIMENTACION SHUT
I
EXTREMOS RANURADOS
I
DE BASURA Ø13mm
I
9
I
EXTREMOS BISELADOS.
I
I
I
I
Ø75
I
I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I
Límite de terreno
EMPOTRAR PARA UNA MANGUERA DE 30 MTS , MEDIDAS DE
Límite de terreno
SOPORTERÍA
DIÁMETRO SEPARACIÓN DE
NOMINAL SOPORTES
pulg mm metros
3/4" 19 1.70
1" 25 1.80
1 1/4" 32 2.00
1 1/2" 38 2.10
2" 50 2.40
2 1/2" 64 2.70
3" 10 3.00 Proyecto: NOVA LIFESTYLE BOSQUES
4" Edificio de departamentos
100 3.20
A LA LONGITUD CALCULADA
DEL SOPORTE AUMENTARLE Ubicación: Av. Antiguo camino a Tecamachalco No. 29
10 cm EN CADA EXTREMO col. el olivo C.P. 52789, municipio de Huixquilucan,
estado de México
SIMBOLOGIA
I I TUBERIA DE ACERO DE ALTA RESISTENCIA Plano: INSTALACION PCI
MARCA VILLACERO, LINEA CONTRA INCENDIO
SPRINKLER., EXTREMOS RANURADOS.
SOTANO 1
GPCI GABINETE DE PROTECCIÓN CONTRA
INCENDIOCON EXTINTORY VALVULA ANGULAR,
MANGUERA DE 30 M. Y CHIFLON DE 38 MM Acotación: 1:125 Clave:
METROS
BAJA COLUMNA DE PROTECCIÓN
BCPCI 2097_IPCI_T1_S01
CONTRA INCENDIO
SUBE COLUMNA DE PROTECCIÓN Dibujó: FORTA Fecha: JUNIO 2019
SCPCI
CONTRA INCENDIO
V.E.A. VALVULA ELIMINADORA DE AIRE MCA VAYREMEX
MOD. EAP
FORTA FORTA FORTA