Está en la página 1de 4

1.

Metrado de Cargas

POR SER CATEGORIA "A" (Inf. Hospitalaria) P = CM +0.50CV

Piso Area(m2) CM(T/m2) CV(T/m2) Peso


1 240 0.8 0.3 228
2 240 0.8 0.3 228
3 240 0.8 0.3 228
4 240 0.8 0.3 228
5 240 0.8 0.3 228
6 240 0.8 0.3 228
7 240 0.8 0.3 228
8 240 0.8 0.3 228
9 240 0.8 0.3 228
10 240 0.8 0.3 228
11 240 0.8 0.3 228
12 240 0.8 0.3 228
13 240 0.8 0.3 228
14 240 0.8 0.3 228
15 240 0.8 0.1 204
3,396.00

2.Calculo de Cortante Basal


37.50
hn m
Zona Lima(Z4) 0.45 CT 60
Uso Inf.Hospitalaria 1.5
Suelo S2 1.05 T 0.63 s
TP 0.60 s TL 2.00 s

C TP <T<TL CUMPLE
Ro Portico 8
Ip 1 C 2.4
Ia 1
R Ro x Ip x Ia 8

V 722.07 Tn
3.Distribucion
por Altura

Piso Pi hi k Pi*hi^k α Fi Qi
1 228 2.50 1.06 603.59566 0.007 5.30 722.07
2 228 5.00 1.06 1260.6382 0.015 11.07 716.78
3 228 7.50 1.06 1939.4895 0.024 17.03 705.71
4 228 10.00 1.06 2632.9029 0.032 23.12 688.68
5 228 12.50 1.06 3337.3499 0.041 29.30 665.56
6 228 15.00 1.06 4050.7161 0.049 35.56 636.26
7 228 17.50 1.06 4771.5862 0.058 41.89 600.70
8 228 20.00 1.06 5498.943 0.067 48.28 558.80
9 228 22.50 1.06 6232.0191 0.076 54.72 510.52
10 228 25.00 1.06 6970.2139 0.085 61.20 455.81
11 228 27.50 1.06 7713.0445 0.094 67.72 394.61
12 228 30.00 1.06 8460.1133 0.103 74.28 326.89
13 228 32.50 1.06 9211.0877 0.112 80.87 252.61
14 228 35.00 1.06 9965.6847 0.121 87.50 171.74
15 204 37.50 1.06 9594.8544 0.117 84.24 84.24

82242.239 722.07
Este análisis no es válido ya que el método estático solo es para estructuras iguales o menores de 30
m y la presente estructura posee 37.5 m de altura.

Por lo tanto ya no se pueden hacer los demas


pasos