Está en la página 1de 1

1 2 3 4 5 6 7 8 9 10 11 12 13

40.04
8.50 2.61 2.40 2.15 1.45 2.28 4.05 4.51
0.15 8.35 0.15 2.46 0.15 0.15 2.00 0.15 1.30 0.15 2.00 0.15 0.15 1.50 0.15 2.20 0.15 2.20 0.15 3.85 0.25 4.38

4.20

TER
PROPIE RENO POZA RICA
DAD P
3.77 RIVAD
40.50 A

BANQUETA 1.60 90 2.86


CUARTO DE SUCIOS
sube
2.76 COLIN
DANCI
B 1.50
2.17 CUARTO DE
RESIDUOS
A - MORTEROS PRA REPELLADOS CE-AR PROP1:5, PARA ASENTAR
TABIQUE DE BARRO ROJO RECOCIDO

H=4.50 M
PELIGROSOS
0.60 1.36
1.20 COCINETA. - MUROS DE TABIQUE DE BARRO ROJO RECOCIDO.
- VENTANERIA DE ALUMINIO
PREMIUM DIESEL 1.50
C
40,000 L 40,000 L
BAÑO - BANQUETAS PERIMETRALES CONCRETO F´C= 150 KG/CM2. ACABADO
0.50 2.00 ESCOBILLADO.
D ALMACEN
1.41 GDAROPA
- REGISTRO STANDART TABIQUE RECOCIDO APLANADO INTERIOR.
1.30 BAÑO 100
0.95 CUARTO DE 90 100 - PISOS Y RECUBRIMIENTOS EN BAÑOS VITRIFICADOS.
3.33 3.33 2.25 2.31 MAQUINAS GDAROPA

- CRISTALES EN VENTANAS EN 6 MM MIN.


E 100 60 - REGISTROS STANDART MARCO Y COTNRAMARCO ANGULO 2" MIN.
60
0.30 N.P.T. +0.50
E' 90 - PISOS Y RECUBRIMIENTOS ASENTADOS CEMENTO CREST O SIMILAR.
90 100 1.00
0.66 1.00 - PERALTE Y HUELLA DE ESCALERA COLADO CON RAMPA HOMOGENEO.
F BAÑO DE
60
BAÑO DE
HOMBRES
- MORTERO EN MUROS Y RECUBRIMIENTOS LIMITE DE PROP.
2.00 CTO. EMPLEADOS
AREA
MUJERES
IMPERMEABILIZANTE EN FABRICACION.
0.59 3.00 ADMINISTRACIÓN
G 9.76 0.60 - PENDIETES EN LOSA DE AZOTEA 2% MIN.
8.61 0.60 CUARTO DE
4.50 4.50
0.60 LIMPIOS N.P.T. +0.50 AREA TIENDA DE
- TODOS LOS MUROS INDICADOS EN PLANTA SERAN DE CARGA Y
2.10 CONVENIENCIA
BAÑO
90
(FUTURO)
DEBEN LEVANTARSE ANTES DEL COLADO DE LA LOSA DEL NIVEL
MAGNA 90
1.65 60,000 L SUPERIOR.
90
ACCESO ACCESO N.P.T. +0.50 - EL ESPESOR DE LAS JUNTAS ENTRE PIEZAS SERA UNIFORME NO
90 N.P.T. +0.50 MAYOR DE 1.5 CMS EN MUROS.
H 1.20
20.02 3.33 3.33 2.27 2.27

0
10
1.50 3.61

0
1.40

10
ACCESO 1.40
I
0.32
I'

0.94 7.15 0.60


J
1.97 ÁREA
BOMBAS DE
N.P.T. +0.00 N.P.T. +0.15 DESCARGA 1.00

BANQUETA
CALLE AMATLAN

N.P.T. +0.35
29.50
N.P.T. +0.15

L
CALLE CERRO AZU
N.P.T. +0.35

N.P.T. +0.35
5.00

CASETA
CTO. ELECTRICO
J 1.20 1.20 N.P.T. +0.50
1.20
P 2.28 P

10.21 3.50 11.51 3.50

N.P.T. +0.35

8.84
0.51
0.13 0.13
27.50
DISTINTIVO ELEVADO

N.P.T. +0.35
N.P.T. +0.35
ANUNCIO

3.64 N.P.T. +0.35

POSTE C.F.E.

N.P.T. +0.15

BANQUETA

11.74 1.80 13.17 1.84 N.P.T. +0.00


CALLE

3 4 CALLE ALAMO 9 10

40.00

PLANTA ARQUITECTONICA GENERAL DE CONJUNTO


REV DESCRIPCION : ELABORADO POR: RESPONSABLE: FECHA: FIRMA:

Mantenimiento y Asesoria Electromecanica S.A.de C.V.

DIAGONAL ZARAGOZA No. 4506-201 PUEBLA, PUE.


ING. GUSTAVO LOPEZ ALVARADO COL. 22 DE SEPTIEMBRE, C.P. 72560
TEL. 01 (222) 2445214 FAX. 01 (222) 2455535
CEDULA PROFESIONAL 1627377 maesa7@prodigy.net.mx
RESPONSABLE PROYECTO