ra

do
va
La
CTO SERVICIO 2x16A
ALUMBRADO SALA Y DORMITORIO

THERMA
ELECT.
2-1x2.5mm2+1x2.5mm2 NH
PATIO
2x16A
ALUMBRADO
2-1x2.5mm2+1x2.5mm2 NH
2x20A
30mA

0.80 x 2.20
2x30 A 2x16A
S 2-1x6mm2 NH +(LT)1x4mm2 TOMACORRIENTES
PVC - P 25mm 2-1x4mm2+1x2.5mm2 NH
2x20A
30mA
0.80 x 2.20
2x16A
0.90 x 2.20 TOMACORRIENTES
2-1x4mm2+1x2.5mm2 NH
2x20A
30mA
S S 2x25A

S TV
S DOR3 2x20A 2-1x4mm2+1x2.5mm2 NH

1x6mm2 NH
0.80 x 2.20

DOR 2 DOR2
S
TV

0.90 x 2.20
0.80 x 2.20

DOR1
S
S
TV
C-6

2x16A
ALUMBRADO COCINA Y SALA
2-1x2.5mm2+1x2.5mm2 NH
0.70 x 1.90
BAÑO 2x16A
ALUMBRADO
DOR 1 2x20A
2-1x2.5mm2+1x2.5mm2 NH
30mA
S 2x16A
S C-2
TOMACORRIENTES

3x32 A 2-1x4mm2+1x2.5mm2 NH
2x20A
C-3 3-1x6mm2 NH +(LT)1x4mm2 30mA
TG102 PVC - P 25mm 2x16A
TOMACORRIENTES
0.90 x 2.20

C-4
2-1x4mm2+1x2.5mm2 NH
2x20A
S S 30mA
2x16A
TOMACORRIENTES
S C-5
C-1
2-1x4mm2+1x2.5mm2 NH
2x20A
30mA
2x25A

2-1x4mm2+1x2.5mm2 NH
TG101

1x6mm2 NH
COCINA
C-4
C-2
C-1
C-3

LEYENDA
ALTURA TIPO
SIMBOLO DESCRIPCION (m) CAJA(mm)

BANDEJA TIPO REJILLA 160x75, 400x75 METALICA


Techo

CAJA DE PASO COMUNICACIONES DE PVC o METALICA

CAJA DE PASO ELECTRICO DE PVC o METALICA OCT-400x70


DPTO 102 TUBERIA EMPOTRADA EN PISO Y/O PARED LINEA A TIERRA
SALA TUBERIA EMPOTRADA EN PISO,TECHO Y/O PARED TOMACORRIENTES

TUBERIA EMPOTRADA EN PISO,TECHO Y/O PARED ALIMENTADOR


DPTO 101
TUBERIA EMPOTRADA EN PISO,TECHO Y/O PARED TOMACORRIENTES

TUBERIA EMPOTRADA EN TECHO Y/O PARED ALUMBRADO

TV SALA
SALIDA PARA ALUMBRADO EN EL TECHO Techo OCT-100x40

SALIDA PARA ALUMBRADO EN LA PARED (BRAQUETE) 2.00 OCT-100x40


RECT.
S INTERRUPTOR UNIPOLAR SIMPLE (10A - 220V) 1.20 100x55x50mm

RECT.
2S INTERRUPTOR UNIPOLAR DOBLE (10A - 220V) 1.20 100x55x50mm
S
RECT.
3S INTERRUPTOR UNIPOLAR TRIPLE (10A - 220V) 1.20 100x55x50mm

RECT.
S3 INTERRUPTOR DE COMMUTACION DE 3 VIAS 1.20 100x55x50mm
0.90 x 2.20

SPOT LIGHT Techo

S 1.20
RECT.
TOMACORRIENTE A PRUEBA DE AGUA 100x55x50mm

S TOMACORRIENTE BIPOLAR DOBLE CON TOMA A TIERRA (15A - 220V) 0.30 / 1.10 RECT.
100x55x50mm

kWh . TOMACORRIENTE BIPOLAR DOBLE PARA LUCES DE EMERGENCIA +1.80


RECT.
kWh

100x55x50mm

. PULSADOR PARA TIMBRE EN CAJA 100 x 53 x 28 h=1.20 SNPT

LINEA A TIERRA

INTERRUPTOR AUTOMATICO TERMOMAGNETICO 220V-60HZ

POZO A TIERRA

F-1 kWh MEDIDOR DE ENERGIA

TABLEROS DE FUERZA, CONTROL, ESTABILIZADO, ALUMBRADO Y TOMACORRIENTES

INTERRUPTOR AUTOMATICO TERMOMAGNETICO CON CAJA MOLDEADA

INTERRUPTOR AUTOMATICO TERMOMAGNETICO NO FUSE

INTERRUPTOR DE PROTECCION DIFERENCIAL

PROYECTA: PROPIETARIO:
Nº FECHA OBSERVACION
& INGENIEROS CONSULTORES SAC
INGENIERIA + CONSULTORIA + SUPERVISION MAXIMO VALENTIN RUTTI
1 23/06/2022 Calle Rodin 134- San Borja Lima 41-Perú telefax: 2245838 EMAIL: iswingenieros@yahoo.es

PROFESIONAL : PLANO:
2 SEPARACION DE INSTALACIONES ELECTRICAS DPTO 101
LUIS ENRIQUE DAVILA CACERES
3 ING. ELECTRICISTA CIP 55245
DPTO 102 , ALUMBRADO,TOMACORRIENTES Y TABLEROS,
DIAGRAMA UNIFILAR
IE-01
PROYECTO:
4 ING.LDC/SCHV 1/6
VIVIENDA MULTIFAMILIAR DPTO 101-102
MZ "T" LOTE 16 COOPERATIVA VIVIENDA PACHACUTEC
5 1/50 JUNIO 2022
DISTRITO SANTA ANITA-LIMA