Está en la página 1de 2

Totally Integrated

Automation Portal

Main [OB1]
Main Propiedades
General
Nombre Main Número 1 Tipo OB Idioma KOP
Numeración Automático
Información
Título "Main Program Sweep (Cy‐ Autor Comentario Familia
cle)"
Versión 0.1 ID personaliza‐
do

Nombre Tipo de datos Valor predet. Comentario


Input
Initial_Call Bool Initial call of this OB
Remanence Bool =True, if remanent data are available
Temp
Constant

Segmento 1:

%I0.0 %I0.2 %I0.4 %M0.0


"P1" "FC1" "FC3" "M1"
S

%M0.0 %M0.1 %Q0.2


"M1" "M2" "MOTOR ARRIBA"

%M0.4 %M0.6
"M5" "M7"

Segmento 2:

%I0.3 %Q0.2 %I0.4 %M0.1


"FC2" "MOTOR ARRIBA" "FC3" "M2"
S

%Q0.1
%M0.1 %M0.2 "MOTOR
"M2" "M3" DERECHA"

Segmento 3:

%Q0.1
"MOTOR %I0.5 %I0.3 %M0.2
DERECHA" "FC4" "FC2" "M3"
S

%M0.2 %M0.3 %Q0.3


"M3" "M4" "MOTOR ABAJO"

%M0.7
"M8"

%I0.5 %I0.2 %Q0.3 %M0.3


"FC4" "FC1" "MOTOR ABAJO" "M4"
S

Segmento 4:

%I0.5 %I0.2 %M0.3 %I0.1 %M0.4


"FC4" "FC1" "M4" "P2" "M5"
S

%Q0.0
%M0.4 %M0.5 "MOTOR
"M5" "M6" IZQUIERDA"

Segmento 5:
Totally Integrated
Automation Portal

%I0.4 %M0.4 %M0.5


"FC3" "M5" "M6"
S

%I0.3 %M0.4 %M0.6


"FC2" "M5" "M7"
S

Segmento 6:

%M0.5 %M0.6 %I0.3 %I0.4 %M0.7


"M6" "M7" "FC2" "FC3" "M8"
S

Segmento 7:

%M0.7 %I0.2 %Q0.3 %M1.0


"M8" "FC1" "MOTOR ABAJO" "M9"

%M1.0 %M0.0
"M9" "M1"
R

%M0.1
"M2"
R

%M0.2
"M3"
R

%M0.3
"M4"
R

%M0.4
"M5"
R

%M0.5
"M6"
R

%M0.6
"M7"
R

%M0.7
"M8"
R