Agreg INGERSOLL RAND R55N-A UCV1009446 60 D780IN-A (15M- CSC SRL 1000L/12b PSG-30 (00192 FA800IG FA800IH
ar
CORREAS: ROD Hr Mnto: Rod-Motor Rod-Airend Aceite: ULTRACOOLAN
FA-IR 54672530 PDM(i+n): 23561319 FA-IR2:2359587
PDM (TAS): PDM(n):23564446 SEP-IR 23708423 F-ACEITE 23424922 55 LITROS
14-dic.-15 10.391 PV 2 PM PDTE: No tenemos cert. Cald y vlv seg.//PM comp+SEC. Recond purg sec. Mon
24-ene.-18 13.721 PP 2.853 I1 2 IR30-1S. PDM (23561319 + 23564446). Chequeo sec., rep. purga capacit. (pé
03-ene.-19 15.166 CR MA 3.571 IN PDTE: Mto + Sust. Transductores (49147127 - 2unid)//Parada "Alto vacío entr
07-ene.-19 15.169 CR MA 3.575 I2 5 PDTE: Vacuostato//INF:Se monta transduct con fuga oil. Por vacuostato roto//
16-ene.-20 16.219 PV 4.418 IN PDTE: Purga Zeo 20 drain (5487/15 24VAC) Pasar PR// Fuga de aceite en raco
20-ago.-20 17.915 CR AM 4.932 I3 10 PDTE: Purga Zeo 20 drain (5487/15 24VAC) Pasar PR// Sust. PDM -2 (235644
21-ago.-20 0 LAB ROJA (09/09/20). Presen desechos visibles (part metál) Recuento part alto. Ve
04-ene.-22 0 INF INF: Tras varias llamadas, Lourdes nos dice que nos llama ella cuando sepan q
28-jun.-22 220.750 PP 6.690 IN Aviso agua detect en red. SEC: parado y tubo salid condens fuera colector de c
23-ago.-22 23-ago.-23 220.993 CR 6.884 I4 55 PDTE: Vlv seg + Fallo secador//PDM (2) + F. lín FA800IG + FA800IH. Secador
29-ago.-22 221.122 PP 0 SEC Sec parado x alarma HTA. Diagnos: fallo presost cntrl mot vent, se sust (0401