Tuberia 1 Tuberia 2 Tuberia 3 R


Z1 208.35 Z2 141.25 Z3 112.15 1
2
L1 6.575 L2 3.525 L3 4.555
D1 20 D2 14 D3 16
f1 0.0185 f2 0.0205 f3 0.0235 3
k1 35.7 k2 39.6 k3 32.4
8
𝐷5 1/2 𝑓𝑖 ∗ 𝐿𝑖 𝑘2
𝑄 = 3.477 ∗ℎ ℎ𝑓𝑖 = 0.0827 ∗ ∗ 𝑄2 ℎ𝐿𝑂𝐶 = 0.0827 ∗ 4 ∗ 𝑄2
𝑓∗𝐿 𝑓 𝐷𝑖5 𝐷𝑖
Q1 = 0.057987 Q2 = 0.030843 Q3 = 0.035384 Zp= 162.4397 0.00
3er Tanteo
Con Darcy sin carga local
Tub. hf+hloc (m) Q (l/s) Q1-(Q2+Q3) =l/s
Vmin = 0.6 1 45.9103 392.9035
ℎ𝑓𝑖 + ℎ𝑙𝑜𝑐 Vmax = 3 2 21.1897 141.9772 0.0000
𝑄 = 3.477 ×
𝑓𝑖 𝑥𝐿𝑖 𝑘𝑖 3 50.2897 250.9263
+ 4
𝐷𝑖5 𝐷𝑖 Tub. V (m/s)
1 1.9385
Zp= 185 2 1.4296
1er Tanteo
Con Darcy sin carga local Con Darcy con carga local 3 1.9344
Tub. hf+hloc (m) Q (l/s) Q1-(Q2+Q3) =l/s Q (l/s) Q1-(Q2+Q3) =l/s Zp= 162.4245 0.0000
4to Tanteo
1 23.350 280.2038 261.3940 Con Darcy con caudal local
2 43.750 204.0073 -225.814 186.6300 -210.229 Tub. hf+hloc (m) Q (l/s) Q1-(Q2+Q3) =l/s
3 72.850 302.0103 284.9927 1 45.9255 366.5887
Zp= 130 2 21.1745 129.8372 0.0000
2do Tanteo
Con Darcy sin carga local Con Darcy con carga local 3 50.2745 236.7515
Tub. hf+hloc (m) Q (l/s) Q1-(Q2+Q3) =l/s Q (l/s) Q1-(Q2+Q3) =l/s Tub. V (m/s)
1 78.350 513.2750 478.8193 1 1.8087
2 11.250 103.4506 260.330 94.6387 243.110 2 1.3073
3 17.850 149.4948 141.0711 3 1.8251